Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Digital Filter Design for Point-on-Wave Sensors: Highlighting Frequency Response Limitations and Enhancing Grid Simulation Accuracy

Data is proving to be the backbone of today's and, more importantly, tomorrow's grid. As the system changes and introduces fast-acting devices like power electronics, overall observability tends to decrease from the utility point-of-view. This can be mitigated by adding more high-fidelity sensors onto the grid, although this incurs a cost. These sensors are never ideal, and each have unique frequency responses that may influence the data produced. This may, in turn, impact the protection and control of the power grid. This paper presents a methodology of representing these point-on-wave sensors digitally by estimating digital-filter representations of them, thereby introducing means of improving the sensor models used in electromagnetic-transient (EMT) simulations. This may help with identifying potential high-frequency, sensor-induced distortions, and system resonance compensation. Three commercial-grade medium-voltage point-on-wave sensors are utilized in a lab environment to obtain experimental frequency responses with a frequency sweep, and it is shown that both Infinite Impulse Response (IIR) and Finite Impulse Response (FIR) filter representations may approximate these responses with varying degrees of accuracy, though each has their own strengths and weaknesses. It is found that, in general, FIR estimation better approximates these sensors than IIR estimation does.

Wilson, Aaron [ORNL] (ORCID:0000000327331697)↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline-based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive-sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

current measurement↗

Surprising Relationship between Silicon Anode Calendar Aging and Electrolyte Components in a Localized High-Concentration Electrolyte System

Although localized high-concentration electrolytes (LHCEs) have been shown to improve the calendar lifetime of silicon anodes, the roles of the electrolyte constituents in calendar aging are not well understood. Here, in this work, we utilize a voltage hold protocol and an LHCE with varying molar ratios of lithium bis(fluorosulfonyl)imide (LiFSI), tetramethylene sulfone (TMS), and 1,1,2,2-tetrafluoroethyl-2,2,3,3-tetrafluoropropyl ether (TTE) to probe the component roles during aging. Interestingly, the estimated calendar lifetime and irreversible lithium losses from the V-hold experiments are independent of the electrolyte formulations. Contrarily, the solid electrolyte interphase (SEI) composition depends on the electrolyte formulation. X-ray photoelectron spectroscopy shows that TMS-coordinated species decompose to form insoluble alkanes and lithium hydroxide (LiOH), while lithium fluoride (LiF) originates from the anion-coordination complex. The SEI composition does not appear to play a significant role in the silicon anode passivity, as measured by parasitic current, suggesting that the SEI-electrolyte interactions dictate the calendar aging mechanisms.

Si anode↗

In-Situ Measurement of Power Loss for Crystalline Silicon Modules Undergoing Thermal Cycling and Mechanical Loading Stress Testing

An in-situ method is proposed for monitoring and estimating the power degradation of mc-Si photovoltaic (PV) modules undergoing thermo-mechanical degradation tests that primarily manifest through cell cracking, such as mechanical load tests, thermal cycling and humidity freeze tests. The method is based on in-situ measurement of the module’s dark current-voltage (I-V) characteristic curve during the stress test, as well as initial and final module flash testing on a Sun simulator. The method uses superposition of the dark I-V curve with final flash test module short-circuit current to account for shunt and junction recombination losses, as well as series resistance estimation from the in-situ measured dark I-Vs and final flash test measurements. The method is developed based on mc-Si standard modules undergoing several stages of thermo-mechanical stress testing and degradation, for which we investigate the impact of the degradation on the modules light I-V curve parameters, and equivalent solar cell model parameters. Experimental validation of the method on the modules tested shows good agreement between the in-situ estimated power degradation and the flash test measured power loss of the modules, of up to 4.31 % error (RMSE), as the modules experience primarily junction defect recombination and increased series resistance losses. However, the application of the method will be limited for modules experiencing extensive photo-current degradation or delamination, which are not well reflected in the dark I-V characteristic of the PV module.

14 SOLAR ENERGY↗

Spray-Coated Silver as Backside Metal for III–V Photovoltaic Devices on GaAs and Ge Substrates

The accelerated increase in demand for III-V space photovoltaics on GaAs and Ge substrates, as well as growing interests in terrestrial applications, motivate the development of cost-effective, high-throughput processing routes of these materials. Here, in this study, we assess spray-coated silver (Ag) back contact metallization as a substitute for electron-beam-evaporated metals currently used in industry. We find that the spray-coated Ag films are dense and continuous. By means of quantum efficiency, dark current-voltage, and illuminated current-voltage characterizations, we show that spray-coated GaAs and Ge solar cells perform similarly to baseline devices with electroplated Au, including under high current densities. We estimate that the thresholds for specific contact resistance below which back contacts do not significantly contribute to resistive loss are 2.1 x 10 -1 Ω•cm 2 for GaAs and 4.7 x 10 -2 Ω•cm 2 for Ge. We experimentally confirm that our spray-coated samples meet these requirements. Peel tests show that the adhesion of plain spray-coated Ag films to the back of p-type Ge substrates used in III-V solar cells is currently insufficient, whereas adhesion to p-type GaAs substrates is outstanding and requires no further optimization.

14 SOLAR ENERGY↗

Data-Driven State of Health Estimation for Second-Life Batteries Using Interpolated Synthetic Data and Feature Selection

Accurate estimation of the State of Health (SOH) for second-life batteries (SLBs) is crucial given their increasing use in energy storage applications. Precise SOH prediction is essential for safe operation and robust battery management systems. A major challenge is the limited availability of datasets for building reliable degradation models. To address this, synthetic data generation through linear interpolation is performed to extend the available data, making it more representative of real-world battery operating conditions. By analyzing feature correlation with SOH, the most relevant features are selected for the model. The proposed approach employs a convolutional neural network (CNN) model trained on this interpolated, feature-selected dataset, using time series data of voltage, temperature, and current over a cycle. By focusing on highly correlated features, the model achieves over 95% accuracy, with mean absolute error and root mean squared error up to 2.27% and 2.64%, respectively, in SOH estimation for two battery datasets tested. These results highlight the potential of combining synthetic data generation and feature selection to enhance SOH predictions, showcasing the superior performance of the proposed CNN model for both new batteries and SLBs.

feature selection↗

Magnetically tuned metal-insulator transition in LaAlO 3 /SrTiO 3 nanowire arrays

A wide family of two-dimensional (2D) systems, including stripe-phase superconductors, sliding Luttinger liquids, and anisotropic 2D materials, can be modeled by an array of coupled one-dimensional (1D) electron channels or nanowire arrays. Here we report experiments in arrays of conducting nanowires with gate and field tunable interwire coupling, that are programmed at the LaAlO 3 /SrTiO 3 interface. We find a magnetically tuned metal-to-insulator transition in which the transverse resistance of the nanowire array increases by up to four orders of magnitude, which can be further tuned with a gate voltage. To explain this behavior, we develop a minimal model of a coupled two-wire system where a Wenzel-Kramers-Brillouin-based approach is used to estimate the transverse tunneling conductance. We demonstrate the existence of distinct conductance features and highlight the crucial role played by the field dependence of the interwire potential barrier on transport properties. Since our model makes minimal assumptions, we expect our predictions to hold for a wide class of coupled 1D systems. The nanowire arrays can serve as model systems to understand the origin of exotic behavior in correlated materials via analog quantum simulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING↗

Benchmarking optimization methods for materials research: Gradient descent and Bayesian optimization for lithium-ion battery aging diagnostics

Accurate and efficient parameter estimation is essential for battery diagnostics and aging analysis. Here, in this study, we compare two optimization-based approaches—gradient descent and Bayesian optimization—for extracting parameters from differential voltage analysis in lithium-ion batteries. While these techniques are widely used, their relative strengths and limitations for this application are not well understood. The study evaluates the trade-offs between these methods in terms of result quality, computational cost, and reliability within this specific application. The diagnostic results from our battery data suggest adopting gradient descent as an initial method for rapid and efficient analysis, while employing more stable optimization techniques, such as Bayesian optimization, as a verification step to mitigate potential instability. Comparing the two methods provides information on algorithmic choice, while inspiring further discussions on selecting appropriate techniques for specific research tasks.

Zhao, Ziqing [Boston Univ., MA (United States)] (O↗

Multiscale Electrothermal Design of a Modular Multilevel Converter for Medium-Voltage Grid-Tied Applications

As a key feature of modular multilevel converters (MMCs), a large number of semiconductor devices are employed in the converter and distributed over a stack of submodules. Each submodule has a strict temperature limit that imposes constraints on the operating range of the converter. Different loading conditions/losses in the submodules lead to unavoidable temperature variations inside the MMC, which consequently affect the system-level performance and reliability. This paper is focused on the electrothermal analysis and design of a medium-voltage silicon carbide (SiC)-based MMC system, from submodule power semiconductors to the overall MMC system integration of multiple submodules, for grid-connected applications. Loss calculations are performed to estimate the cooling requirements and aid thermal design at different levels. The performance of a forced-air cooling approach is analyzed within a numerical modeling framework. Maximum temperature of the SiC power modules is predicted using numerical tools. Thermal design of the MMC cabinet with various arrangements of air inlet(s) and outlet(s) is investigated and compared from a cooling performance perspective. A fully resolved model of the arrangement that yields optimal results is developed to accurately predict the temperature profile of the essential components in the submodules.

computational fluid dynamics↗

Evaluation of Amorphous Oxide Coatings for High-Voltage Li-Ion Battery Applications Using a First-Principles Framework

Cathode surface coatings are widely used industrially as a means to suppress degradation and improve electrochemical performance of lithium-ion batteries. However, developing an optimal coating is challenging, as different coating materials may enhance one aspect of performance while hindering another. Furthermore, to elucidate the fundamental thermodynamic and transport properties of amorphous cathode coating materials, here, we present a framework for calculating and analyzing the Li + and O 2- transport and the stability against delithiation in such materials. Our framework includes systematic workflows of ab-initio molecular dynamics calculations to obtain amorphous structures and diffusion trajectories coupled with an analysis of critical changes of the active-ion local environment during diffusion. Based on these data, we provide an estimate of room-temperature diffusivities, including statistical error bars, and the evaluation of the coating suitability in terms of its ability to facilitate Li + transport while blocking O 2- transport. Finally, we add the thermodynamic stability analysis of the coating chemistry within the operating voltage of common Li-ion cathodes. We apply this framework to two commonly used amorphous coating materials, Al 2 O 3 and ZnO. We find that (1) in general, a higher Li + content increases both Li + and O 2- diffusivities in both Al 2 O 3 and ZnO. Also, Li + and O 2- diffuse much faster in ZnO than in Al 2 O 3 . (2) However, neither Al 2 O 3 nor ZnO is expected to retain a significant concentration of Li + at high charge. (3) ZnO performs much more poorly in terms of O 2- blocking, and hence, Al 2 O 3 is preferred for high-voltage cathode applications. These results will help to quantitatively evaluate amorphous materials, such as metal oxides and fluorides, for different performance metrics and facilitate the development of optimal cathode coatings.

25 ENERGY STORAGE↗

Power Grid Reliability Estimation via Adaptive Importance Sampling

Electricity production currently generates approximately 25% of greenhouse gas emissions in the USA. Thus, increasing the amount of renewable energy is a key step to carbon neutrality. However, integrating a large amount of fluctuating renewable generation is a significant challenge for power grid operating and planning. Grid reliability, i.e., an ability to meet operational constraints under power fluctuations, is probably the most important of them. In this letter, we propose computationally efficient and accurate methods to estimate the probability of line overflow, i.e., reliability constraints violation, under a known distribution of renewable energy generation. To this end, we investigate an importance sampling approach, a flexible extension of Monte-Carlo methods, which adaptively changes the sampling distribution to generate more samples near the reliability boundary. The approach allows to estimate overload probability in real-time based only on a few dozens of random samples, compared to thousands required by the plain Monte-Carlo. Our study focuses on high voltage direct current power transmission grids with linear reliability constraints on power injections and line currents. Herein, we propose a novel theoretically justified physics-informed adaptive importance sampling algorithm and compare its performance to state-of-the-art methods on multiple IEEE power grid test cases.

power system faults↗

Sources of error and methods to improve accuracy in interface state density analysis using quasi-static capacitance–voltage measurements in wide bandgap semiconductors

Characterizing interface trap states in commercial wide bandgap devices using frequency-based measurements requires unconventionally high probing frequencies to account for both fast and slow traps associated with wide bandgap materials. The C - ψs technique has been suggested as a viable quasi-static method for determining the interface trap state densities in wide bandgap systems, but the results are shown to be susceptible to errors in the analysis procedure. Here this work explores the primary sources of errors present in the C - ψs technique using an analytical model that describes the apparent response for wide bandgap MOS capacitor devices. Measurement noise is shown to greatly impact the linear fitting routine of the 1/C$^{*2}_s$ vs Ψ s plot to calibrate the additive constant in the surface potential/gate voltage relationship, and an inexact knowledge of the oxide capacitance is also shown to impede interface trap state analysis near the band edge. In addition, a slight nonlinearity that is typically present throughout the 1/C$^{*2}_s$ vs Ψ s plot hinders the accurate estimation of interface trap densities, which is demonstrated for a fabricated n-SiC MOS capacitor device. Methods are suggested to improve quasi-static analysis, including a novel method to determine an approximate integration constant without relying on a linear fitting routine.

42 ENGINEERING↗

Assessing Electrolyte Fluorination Impact on Calendar Aging of Blended Silicon-Graphite Lithium-Ion Cells Using Potentiostatic Holds

Silicon-based lithium-ion batteries have started to meet cycle life metrics, but they exhibit poor calendar life. Here, electrolyte fluorination impact on calendar fade of blended silicon-graphite anodes is explored using a LiPF 6 in EC:EMC:FEC electrolyte vs LiBOB in EC:EMC electrolyte. We utilize a combined experimental-modeling approach applying potentiostatic voltage holds (V-hold) to evaluate electrolyte suitability for calendar life in a shortened testing timeframe (~2 months). Our theoretical framework deconvolutes the irreversible parasitic capacity losses (lithium lost to the solid electrolyte interphase) from the V-hold electrochemical data. Unfluorinated electrolyte (dominant LiBOB reduction) exhibits higher cell resistance as compared to fluorinated electrolyte (dominant FEC reduction). Both systems have similar irreversible capacities during the voltage hold duration with slower rate of parasitic capacity loss for the LiBOB system. Extrapolation of the parasitic losses to end of life capacity fade of 20% shows LiBOB electrolyte outperforming LiPF 6 electrolyte in calendar life. The results demonstrate the applicability of the V-hold protocol as a rapid material screening tool providing semi-quantitative calendar lifetime estimates.

25 ENERGY STORAGE↗

Multi-Area Distribution System State Estimation Using Decentralized Physics-Aware Neural Networks

The development of active distribution grids requires more accurate and lower computational cost state estimation. In this paper, the authors investigate a decentralized learning-based distribution system state estimation (DSSE) approach for large distribution grids. The proposed approach decomposes the feeder-level DSSE into subarea-level estimation problems that can be solved independently. The proposed method is decentralized pruned physics-aware neural network (D-P2N2). The physical grid topology is used to parsimoniously design the connections between different hidden layers of the D-P2N2. Monte Carlo simulations based on one-year of load consumption data collected from smart meters for a three-phase distribution system power flow are developed to generate the measurement and voltage state data. The IEEE 123-node system is selected as the test network to benchmark the proposed algorithm against the classic weighted least squares and state-of-the-art learning-based DSSE approaches. Numerical results show that the D-P2N2 outperforms the state-of-the-art methods in terms of estimation accuracy and computational efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Resilient Flexible Alternating Current Transmission Systems (XFACTS)

This report summarizes the activities conducted under the DOE-OE funded project DEOE0000897, Cyber Attack Resilient Flexible AC Systems – XFACTS. Hitachi Energy (HE), in collaboration with ABB Inc. (ABB), Bonneville Power Administration (BPA), University of Illinois at Urbana-Champaign (UIUC), Iowa State University (ISU), and University of Idaho (UI) pursued the development of a system of defense for Flexible Alternating current Transmission Systems against cyber-attacks (XFACTS). A FACTS substation enhanced with XFACTS defense mechanisms will be capable of mitigating cyberattacks especially those that seek to control electrical parameters like voltage or current and interrupt the power flow in AC lines. It empowers existing FACTS controllers and associated intelligent electronic devices to detect and mitigate malicious intents to depress system voltages, destabilize power flows, trip AC circuit breakers, corrupt currents, and voltages, even if the malicious commands and the measurements have correct syntax. The XFACTS functions utilize the physics of active power electronic systems, control and protection, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected FACTS substation devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Endpoint Use Efficiency Comparison for AC and DC Power Distribution in Commercial Buildings

Advances in power electronics and their use in Miscellaneous Electric Loads (MELs) in buildings have resulted in increased interest in using low-voltage direct current (DC) power distribution as a replacement for the standard alternating current (AC) power distribution in buildings. Both systems require an endpoint converter to convert the distribution system voltage to the MELs voltage requirements. This study focused on the efficiency of these endpoint converters by testing pairs of AC/DC and DC/DC power converters powering the same load profile. In contrast to prior studies, which estimated losses based on data sheet efficiency and rated loads, in this study, we used part load data derived from real-world time-series load measurements of MELs and experimentally characterized efficiency curves for all converters. The measurements performed for this study showed no systematic efficiency advantage for commercially available DC/DC endpoint converters relative to comparable, commercially available AC/DC endpoint converters. For the eight appliances analyzed with the pair of converters tested, in 50%, the weighted energy efficiency of the DC/DC converter was higher, while, for the other 50%, the AC/DC converter was. Additionally, the measurements indicated that the common assumption of using either data sheet efficiency values or efficiency at full load may result in substantial mis-estimates of the system efficiency.

AC/DC converters↗