Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ventilation rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Assessing the use of portable air cleaners for reducing exposure to airborne diseases in a conference room with thermal stratification

The COVID-19 pandemic has highlighted the need for strategies that mitigate the risk of aerosol disease transmission in indoor environments with different ventilation strategies. It is necessary for building operators to be able to estimate and compare the relative impacts of different mitigation strategies to determine suitable strategies for a particular situation. Using a validated CFD model, this study simulates the dispersion of exhaled contaminants in a thermally stratified conference room with overhead heating. The impacts of portable air-cleaners (PACs) on the room airflow and contaminant distribution were evaluated for different PAC locations and flow rates, as well as for different room setups (socially distanced or fully occupied). To obtain a holistic view of a strategy's impacts under different release scenarios, we simultaneously model the steady-state distribution of aerosolized virus contaminants from eight distinct sources in 18 cases for a total of 144 release scenarios. The simulations show that the location of the source, the PAC settings, and the room set-up can impact the average exposure and PAC effectiveness. For this studied case, the PACs reduced the room average exposure by 31%-66% relative to the baseline case. Some occupant locations were shown to have a higher-than-average exposure, particularly those seated near the airflow outlet, and occupants closest to sources tended to see the highest exposure from said source. We found that these PACs were effective at reducing the stratification caused by overhead heating, and also identified at least one sub-optimal location for placing a PAC in this space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Machine Learning-based Approach to Predict the Aggregate Flexibility of HVAC Systems

Use of renewable energy resources can play a significant role in mitigation of climate change since they reduce the dependency on fossil fuels. However, high penetration of renewable energy resources into the power grid may cause some reliability problems. Ancillary services are key to realize the potential of renewable resources without disturbing the grid reliability. In recent years, many control approaches focused on exploiting the aggregate flexible heating, ventilation, and air-conditioning (HVAC) loads of buildings. However, there are still research gaps in assessing in advance the resulting indoor temperature responses for given total power and weather profiles before implementing the controls in the buildings. Such an assessment is critical to guarantee satisfying both the grid related objective (reliability) and the building related objective (occupants' comfort). Towards addressing this research gap, this paper presents a machine-learning approach for predicting the ratings of indoor temperature responses. In this approach, a prediction model was developed using a dataset generated by a set of model-free control simulations. The developed model achieved high prediction accuracy and showed the potential of the proposed approach.

Amasyali, Kadir↗

Effects of diffusion impairment on O2 and CO2 time courses in pulmonary capillaries.

Simultaneous time courses for O2 and CO2 exchange along the capillary have been calculated for homogeneous lungs, allowing for O2-CO2 interactions, dissolved O2, and chemical reaction rates. As diffusing capacity (Dl) was reduced, the transfer of CO2 and O2 was impaired by similar amounts, in spite of the 20-fold greater diffusing capacity for CO2. The reason why CO2 is affected so much is that the slope of the content against partial pressure is so much greater in blood than tissue for this gas. Because of the shapes of their respective dissociation curves, O2 transfer was most affected at normal ventilation-perfusion ratios, whereas CO2 was most affected at high ratios. Exercise exaggerated the impairment of transfer of both gases.

Wagner, P. D.↗

Glovebox CFD Analysis: Low-Flow, Laminar CFD Analysis of Glovebox Ventilation and Humidity Transport in Ansys Fluent 2025 R1

There are gloveboxes that frequently exceed the 30% relative humidity level required for operations. These exceedances result in alternative operations needing to be utilized. This report documents a computational fluid dynamics (CFD) analysis performed to characterize airflow and humidity transport within a representative glovebox under nominal, low-flow conditions. The analysis focuses on establishing the flow regime, identifying transport-limited regions, and evaluating the implications of laminar flow on humidity removal. A single-phase, laminar flow model with a species transport model was used to represent air and water vapor mixing. Results demonstrate that, at the nominal flow rates, airflow is laminar with weak mixing, which will result in long residence times, tens of minutes long or more, in low-velocity regions. These conclusions suggests that humidity reduction is transport-limited. This analysis provides qualitative insight into airflow structure and humidity transport trends. In addition to characterization of glovebox airflow and humidity transport, results are intended to inform experimental validation and future transient modeling efforts.

42 ENGINEERING↗

Space Suit Portable Life Support System Test Bed (PLSS 1.0) Development and Testing

A multi-year effort has been carried out at NASA-JSC to develop an advanced extra-vehicular activity Portable Life Support System (PLSS) design intended to further the current state of the art by increasing operational flexibility, reducing consumables, and increasing robustness. Previous efforts have focused on modeling and analyzing the advanced PLSS architecture, as well as developing key enabling technologies. Like the current International Space Station Extra-vehicular Mobility Unit PLSS, the advanced PLSS comprises three subsystems required to sustain the crew during extra-vehicular activity including the Thermal, Ventilation, and Oxygen Subsystems. This multi-year effort has culminated in the construction and operation of PLSS 1.0, a test bed that simulates full functionality of the advanced PLSS design. PLSS 1.0 integrates commercial off the shelf hardware with prototype technology development components, including the primary and secondary oxygen regulators, Ventilation Subsystem fan, Rapid Cycle Amine swingbed carbon dioxide and water vapor removal device, and Spacesuit Water Membrane Evaporator heat rejection device. The overall PLSS 1.0 test objective was to demonstrate the capability of the Advanced PLSS to provide key life support functions including suit pressure regulation, carbon dioxide and water vapor removal, thermal control and contingency purge operations. Supplying oxygen was not one of the specific life support functions because the PLSS 1.0 test was not oxygen rated. Nitrogen was used for the working gas. Additional test objectives were to confirm PLSS technology development components performance within an integrated test bed, identify unexpected system level interactions, and map the PLSS 1.0 performance with respect to key variables such as crewmember metabolic rate and suit pressure. Successful PLSS 1.0 testing completed 168 test points over 44 days of testing and produced a large database of test results that characterize system level and component performance. With the exception of several minor anomalies, the PLSS 1.0 test rig performed as expected; furthermore, many system responses trended in accordance with pre-test predictions.

Watts, Carly↗

Voluntary control of breathing does not alter vagal modulation of heart rate

Variations in respiratory pattern influence the heart rate spectrum. It has been suggested, hence, that metronomic respiration should be used to correctly assess vagal modulation of heart rate by using spectral analysis. On the other hand, breathing to a metronome has been reported to increase heart rate spectral power in the high- or respiratory frequency region; this finding has led to the suggestion that metronomic respiration enhances vagal tone or alters vagal modulation of heart rate. To investigate whether metronomic breathing complicates the interpretation of heart rate spectra by altering vagal modulation, we recorded the electrocardiogram and respiration from eight volunteers during three breathing trials of 10 min each: 1) spontaneous breathing (mean rate of 14.4 breaths/min); 2) breathing to a metronome at the rate of 15, 18, and 21 breaths/min for 2, 6, and 2 min, respectively; and 3) breathing to a metronome at the rate of 18 breaths/min for 10 min. Data were also collected from eight volunteers who breathed spontaneously for 20 min and breathed metronomically at each subject's mean spontaneous breathing frequency for 20 min. Results from the three 10-min breathing trials showed that heart rate power in the respiratory frequency region was smaller during metronomic breathing than during spontaneous breathing. This decrease could be explained fully by the higher breathing frequencies used during trials 2 and 3 of metronomic breathing. When the subjects breathed metronomically at each subject's mean breathing frequency, the heart rate powers during metronomic breathing were similar to those during spontaneous breathing. Our results suggest that vagal modulation of heart rate is not altered and vagal tone is not enhanced during metronomic breathing.

Non-NASA Center↗

Investigation of Sooting in Microgravity Droplet Combustion: Fuel-Dependent Effects

Kumagai and coworkers first performed microgravity droplet combustion experiments [Kumagai, 1957]. The primary goal of these early experiments were to validate simple 'd(sup 2)-law models [Spalding, 1954, Godsave, 1954] Inherent in the 'd(sup 2) -law' formulation and in the scope of the experimental observation is the neglect of sooting behavior. In fact, the influence of sooting has not received much attention until more recent works [Choi et al., 1990; Jackson et al., 1991; Jackson and Avedisian, 1994; Choi and Lee, 1996; Jackson and Avedisian, 1996; Lee et al., 1998]:. Choi and Lee measured soot volume fraction for microgravity droplet flames using full-field light extinction and subsequent tomographic inversion [Choi and Lee, 1996]. In this investigation, soot concentrations were measured for heptane droplets and it was reported that soot concentrations were considerably higher in microgravity compared to the normal gravity flame. It was reasoned that the absence of buoyancy and the effects of thermophoresis resulted in the higher soot concentrations. Lee et al. [1998] performed soot measurement experiments by varying the initial droplet diameter and found marked influence of sooting on the droplet burning behavior. There is growing sentiment that sooting in droplet combustion must no longer be neglected and that "perhaps one of the most important outstanding contributions of (micro)g droplet combustion is the observation that in the absence of asymmetrical forced and natural convection, a soot shell is formed between the droplet surface and the flame, exerting an influence on the droplet combustion response far greater than previously recognized." [Law and Faeth, 1994]. One of the methods that we are exploring to control the degree of sooting in microgravity is to use different fuels. The effect of fuel structure on sooting propensity has been investigated for over-ventilated concentric coflowing buoyant diffusion flames. (Glassman, 1996]. In these investigations, the fuel flowrate was increased until smoke was observed to escape from the "luminous visible flame" [Glassman, 1996]. A total of 29 fuels were used in order to characterize relative sooting propensity. The sooting propensity of a particular fuel was assessed by comparing the flowrates for soot emission from the tip of the flame. It was reported that the sooting tendency for diffusion flames increased for fuels with higher rates of pyrolysis. Randolph and Law [1986 and not 1994] also examined the effect of fuel structure on droplet sooting behavior. In their experiments the droplets were separated from the bulk gas stream and quenched with nitrogen prior to gravimetric measurements. A variety of fuels were studied, namely aromatics, phenyl-alkanes and alkanes. The results were in qualitative agreement with the work of Glassman [1986]. Vander Wal et al. [1994] performed relative soot concentration measurements using laser-induced incandescence for heptane and decane fuel droplets burning under normal-gravity conditions. It was found that soot volume fractions for decane was more than a factor of two larger than that for heptane. Although the normal-gravity investigations have provided some important insights regarding the influence of fuel structure on the sooting behavior of droplet flames, results cannot be easily extrapolated for microgravity studies since increased residence times and thermophoretic effects must be considered in greater detail. Several studies have compared sooting behavior of different fuel droplets burning under microgravity conditions [Card and Choi, 1990; Jackson et al., 1991; Jackson and Avedisian, 1994], however, detailed quantitative results were not provided. In all of these previous studies, the degree of sooting was only visually assessed from an incandescent backlighted image of the soot containing region. Such techniques can provide misleading results regarding sooting behavior [Choi, 1996].

Manzello, Samuel L.↗

Localized Ignition And Subsequent Flame Spread Over Solid Fuels In Microgravity

Localized ignition is initiated by an external radiant source at the middle of a thin solid sheet under external slow flow, simulating fire initiation in a spacecraft with a slow ventilation flow. Ignition behavior, subsequent transition simultaneously to upstream and downstream flame spread, and flame growth behavior are studied theoretically and experimentally. There are two transition stages in this study; one is the first transition from the onset of the ignition to form an initial anchored flame close to the sample surface, near the ignited area. The second transition is the flame growth stage from the anchored flame to a steady fire spread state (i.e. no change in flame size or in heat release rate) or a quasi-steady state, if either exists. Observations of experimental spot ignition characteristics and of the second transition over a thermally thin paper were made to determine the effects of external flow velocity. Both transitions have been studied theoretically to determine the effects of the confinement by a relatively small test chamber, of the ignition configuration (ignition across the sample width vs spot ignition), and of the external flow velocity on the two transitions over a thermally thin paper. This study is currently extending to two new areas; one is to include a thermoplastic sample such poly(methymethacrylate), PMMA, and the other is to determine the effects of sample thickness on the transitions. The recent results of these new studies on the first transition are briefly reported.

Kashiwagi, T.↗

Thermal Performance Testing of EMU and OSS Liquid Cooling Garments

A test was conducted to evaluate three factors influencing the thermal performance of liquid cooling garments (LCG): (1) the comparable thermal performance of an Oceaneering developed engineering evaluation unit (EEU) prototype LDG, (2) the effect of the thermal comfort undergarment (TCU), and (3) the performance of a torso or upper body only LCG configuration. To evaluate the thermal performance of each configuration a metabolic test was conducted, utilizing suited subjects to generate the metabolic heat. For this study three (3) test subjects of similar health and weight produced a metabolic load on the LDG configuration by either resting (300-600 BTU/hr), walking at a slow pace (1200 BRU/hr), and walking at a brisk pace (2200 BTU/hr), as outlined in Figure 1, the metabolic profile. During the test, oxygen consumption, heart rate, relative humidity, air flow, inlet and outlet air pressure, inlet and outlet air temperature, delta air temperature, water flow (100 lb/hr), inlet water temperature (64 F), delta water temperature, water pressure, core body temperature, skin temperature, and sweat loss data was recorded. Four different test configurations were tested, with one configuration tested twice, as outlined in Table 1. The test was conducted with the suit subjects wearing the Demonstrator Suit, pressurized to vent pressure (approximately 0.5 psig). The demonstrator suit has an integrated ventilation duct system and was used to create a relevant environment with a captured ventilation return, an integrated vent tree, and thermal insulation from the environment.

Rhodes, Richard↗

Physiologically based modeling reveals different risk of respiratory depression after fentanyl overdose between adults and children

Despite a rapid increase in pediatric mortality rate from prescription and illicit opioids, there is limited research on the dose-dependent impact of opioids on respiratory depression in children, the leading cause of opioid-associated death. In this article, we extend a previously developed translational model to cover pediatric populations by incorporating age-dependent pharmacokinetic, pharmacodynamic, and physiological changes compared to adults. Our model reproduced previous perioperative clinical findings that adults and children have similar risk of respiratory depression at the same plasma fentanyl concentration when specific endpoints (minute ventilation, CO 2 tension in the blood) were used. However, our model points to a potential caveat that, in a perioperative setting, routine use of mechanical ventilation and supplemental oxygen maintained the blood and tissue oxygen partial pressures in patients and prevented the use of oxygen-related endpoints to evaluate the consequences of respiratory depression. In a community setting when such oxygenation procedures are not immediately available, our model suggests that the higher oxygen demand and reduced cerebrovascular reactivity could make children more susceptible to severe hypoxemia and brain hypoxia, even with the same plasma fentanyl concentration as adults. Our work indicates that when developing intervention strategies to protect children from opioid overdose in a community setting, these pediatric-specific factors may need to be considered.

60 APPLIED LIFE SCIENCES↗

Empirical Validation of Multi-Zone HVAC System Model: Evaluation of Existing Infiltration Models used in Building Energy Simulation

Infiltration can have a significant impact on building loads. Studies have shown that infiltration can account for 15-40% of annual space conditioning needs in commercial buildings (Emmerich et al. 2019; Younes et al. 2012). The driving force of infiltration is the pressure difference across the building envelope caused by wind, the stack effect (known as buoyancy effect), and the operation of ventilation equipment. Wind pressure is governed by wind direction, speed, building shape, and other structures around the building. The stack effect is a function of the building height and air density differences of ambient air (Han, 2015). The effect of wind is dominant in low-rise residential buildings, and the stack effect is dominant in highrise buildings (ASHRAE 2017). In building energy simulation programs (e.g., EnergyPlus), various empirical infiltration models (e.g., the effective leakage area model, the flow coefficient model) are available to simulate infiltration rates. To help users in selecting a proper infiltration model for modeling of the two-story Flexible Research Platform (FRP), the team evaluates the existing infiltration models in EnergyPlus based on field measurements from the FRP. The blower door and tracer gas decay tests were performed in the FRP. The blower door test result was used to estimate input parameters required in the infiltration models. The actual infiltration rates were estimated with the tracer gas decay test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of gravitational sedimentation on simulated aerosol dispersion in the human acinus

We studied the effect of gravitational sedimentation on the dispersion of 0.5 and 1 micrometer-diameter particle boluses within a two-dimensional symmetric six-generation model of the human acinus. Boluses were introduced at the beginning of a 2-s inspiration immediately followed by a 4-s expiration, in normal gravity (1 G) and in the absence of gravity (0 G). The flow corresponded to a flow rate at the mouth of 500 ml/s. In 0 G, simulated dispersion (Hsim) was 16 ml for both particle sizes. In 1 G, Hsim was 71 and 242 ml for 0.5 and 1 micrometer-diameter particles, respectively, showing the effect of gravitational sedimentation. The difference between experimental data (J. Appl. Physiol. 86 (1999) 1402) and simulations was independent of particle size. This suggests that the residual dispersion was independent of the intrinsic properties of the particles and was more likely due to other mechanisms such as ventilation inhomogeneities, cardiogenic oscillations and alveolar wall motion. c2003 Elsevier Science Ltd. All rights reserved.

short duration↗

Characterization of the indoor near-field aerosol transmission in a model commercial office building

To evaluate the exposure potential of infectious aerosols containing SARS-CoV-2 in an office building setting, synthetic test aerosols were used to experimental study airborne particle transmission in a multizone small office test building at the Oak Ridge National Laboratory. Nine measurement points in a single zone using active aerosol impactors report that the coefficient of variation of the time-averaged concentration is <10% in two campaigns and < 15% in one campaign, so a nearly well-mixed condition was noted. To understand the effect of HVAC system operation on the dynamic concentration of aerosols in office spaces, an aerosol transport model that includes factors such as outside air (OA) ratio, filtration, return air fraction, transport loss in air ducts, and particle deposition has been developed. The results of model fitting demonstrate strong agreement with experimental data. Overall, our investigation finds the return air fraction effects outweigh other mechanisms for the aerosol recirculation in this study, and the impact of air change rate (ACR) is more important than the small particle deposition for aerosol removal. Because ACR dominates the aerosol transport, the full model can be simplified to just one factor, the ACR, while maintaining an acceptable representation of the experimental data.

60 APPLIED LIFE SCIENCES↗

Important influence of respiration on human R-R interval power spectra is largely ignored

Frequency-domain analyses of R-R intervals are used widely to estimate levels of autonomic neural traffic to the human heart. Because respiration modulates autonomic activity, we determined for nine healthy subjects the influence of breathing frequency and tidal volume on R-R interval power spectra (fast-Fourier transform method). We also surveyed published literature to determine current practices in this burgeoning field of scientific inquiry. Supine subjects breathed at rates of 6, 7.5, 10, 15, 17.1, 20, and 24 breaths/min and with nominal tidal volumes of 1,000 and 1,500 ml. R-R interval power at respiratory and low (0.06-0.14 Hz) frequencies declined significantly as breathing frequency increased. R-R interval power at respiratory frequencies was significantly greater at a tidal volume of 1,500 than 1,000 ml. Neither breathing frequency nor tidal volume influenced average R-R intervals significantly. Our review of studies reporting human R-R interval power spectra showed that 51% of the studies controlled respiratory rate, 11% controlled tidal volume, and 11% controlled both respiratory rate and tidal volume. The major implications of our analyses are that breathing parameters strongly influence low-frequency as well as respiratory frequency R-R interval power spectra and that this influence is largely ignored in published research.

NASA Discipline Cardiopulmonary↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Experimental analysis of convective drying of paper and board

Conventional multi-cylinder drying of paper and board involves a mixture of conductive drying from steam-heated dryer cylinders and convective drying by the flow of heated air over the surface of the paper web in the pockets. Pocket ventilation is a critical component in assisting heat and mass transfer during the drying process but is the primary contributor towards removing evaporated water from the web. Air temperature, velocity, and humidity are critical parameters involved in the convective drying process. This paper covers an experimental study involving the design and development of a small lab-scale setup for convective drying of various grades of paper and board, monitoring multiple parameters like paper temperature, moisture content, air humidity, temperature, and velocity measured in situ as the drying proceeds with continuous and accurate sampling capabilities for all parameters in the sample and the system. Instantaneous drying rates, heat, and mass transfer coefficients were also deduced for every time step till the paper completely dried. Furthermore, the coefficients obtained were also reported in the form of dimensionless correlations, and the results were compared against traditional correlations used in the modelling of paper drying. Furthermore, this data will be useful in process development, modelling, design, and the paper drying process simulation.

42 ENGINEERING↗

The Sensitivity of the Equatorial Pacific ODZ to Particulate Organic Matter Remineralization in A Climate Model Under Pre-Industrial Conditions

Marine oxygen plays a fundamental role in regulating the transfer of organic carbon and nutrients to their dissolved inorganic forms, serving as the terminal electron acceptor for heterotrophic respiration. Oxygen can become limiting to these processes in coastal and open-ocean oxygen deficient zones (ODZs). The maintenance of ODZs depends on the balance between physical processes such as ventilation and biogeochemical processes such as remineralization. These two processes act in opposing directions on ODZs, with ventilation responsible for transporting oxygen from the surface, where it is near saturation with the partial pressure of O2 in the atmosphere, to deeper oxygen-depleted layers, and remineralization acting to consume oxygen through biogeochemical processes such as microbial degradation throughout the water column. Remineralization is represented in all CMIP6 models, but the actual parameterizations, as well as their magnitude, are widely varying. In this study, we examine the sensitivity to remineralization of the equatorial Pacific ODZ O2 ol/kg) in a model; the NASA GISS Ocean Biogeochemical Model (NOBM-G) embedded in the NASA-GISS coupled atmosphere-ocean model. We find that increasing the remineralization rate shoals the ODZ onset depth (i.e. the regionally averaged upper bound of the ODZ), and decreases ODZ volume and regional-averaged thickness. Changes in biological consumption and vertical convergence of oxygen are identified as the primary contributors to changes in ODZ onset depth. ODZ thickness is mainly influenced by the shoaling of the bottom boundary of the ODZ, which decreases with maximum remineralization rate due to decreasing oxygen consumption and increasing horizontal oxygen convergence in deep waters. On the other hand, vertically-averaged ODZ area has a more complex, non-monotonic relationship with maximum remineralization rate. While these findings suggest an important role for remineralization in determining the shape of the ODZ in our model, the relative importance of remineralization vs. other physical parameterizations remains to be established. While our results reflect the structure of our ocean biogeochemical model, the relationship of remineralization to ODZ characteristics in other models should be examined to better inform model inter-comparisons.

Oxygen-deficient zone↗

Recovery of Natural Gas Equipment Emissions into Gas Compression Engines for the Reduction of Potential Greenhouse Gas Emissions

Since the turn of the millennium, the United States (U.S.) oil and natural gas (ONG) industry has nearly doubled its natural gas production rate. As a result, the ONG industry has recently come under increasing scrutiny for its contributions to greenhouse gas (GHG) emissions. Consequently, various solutions to this problem have been proposed and formulated to reduce the impacts of GHG emissions on the environment. West Virginia University (WVU) have found it important to research the impacts of recovering vented gas streams into prime-mover engines. The U.S. Department of Energy (DOE) and National Energy Technology Laboratory (NETL) have granted WVU funding to research and develop a “Methane Mitigator” (M2) - a “Scalable Vent Mitigation Strategy to Simultaneously Reduce Methane Emissions and Fuel Consumption from the Compression Industry.” One of the main areas of interest for this research was the collection of emissions from natural gas equipment into a Caterpillar G3508J natural gas compression engine. The parameters being analyzed from the engine were brake-specific emissions and power output. The emissions sources considered for this research were pneumatic controllers (PCs), reciprocating compressor vents, and the engine’s open crankcase breather. The compressor vent and PC emissions were simulated using a mass flow controller (MFC) and flowed into the engine using two separate methods: (1) directly into the air intake, and (2) through a retrofitted closed crankcase ventilation system (CCV), serving as a buffer volume. The crankcase emissions were quantified without the CCV, and the impact on exhaust emissions from circulating the crankcase gases into the intake was measured. The simulated compressor vent and PC flows from the MFC had limited effect on the steady state operation of the engine and resulting performance. When the simulated flows were fed directly into the engine’s air intake, the changes within the engine’s continuous performance and emission parameters were larger but lasted for shorter durations. Conversely, when the simulated flows were fed into the CCV before entering the air intake, the changes in the engine’s performance and emission parameters were less pronounced for continuous analysis but lasted for longer durations. In either case, the continuous emission changes in both emissions and performance varied in size depending on the test scenario being run, but the cycle average changes in emissions and performance showed little impact overall compared to the engine’s baseline operation. As a result, the inclusion of a CCV shows a decrease in baseline carbon dioxide equivalent (CO2-eq.) engine emissions (from combined exhaust and open crankcase) of almost 4%. Likewise, the CCV inclusion reduced baseline total methane (CH4) from combined exhaust and open crankcase by upwards of 16%. These atmospheric emissions only decreased further with the inclusions of collected PC and compressor vent flows. The resulting changes in time-averaged rated exhaust behavior (or lack thereof) prove that the proposed M2 system could likely be deployed at sites with modern lean-burn natural gas engines as a viable option for reducing and eliminating potential GHG sources that would have otherwise been unutilized as energy sources.

03 NATURAL GAS↗