Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “validation method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

NDMAS Portal Updates

Overview of current ART-GCR Data, including fuel fabrication, irradiation monitoring, fuel and graphite, post-irradiation examination, graphite characterization, high temperature metals mechanical tests, methods validation data (including: HTTR, NSTF, and HTTF), addition of AGR fuel data, other GCR and related data, updated high temperature metals, ongoing and upcoming work, users guide, and the link to those interested in access to NDMAS.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Quantitative Method Development and Validation of Naloxone and 6α‐naloxol from Male African Green Monkey Plasma.

Theopioid epidemic is a rapidly growing crisis around the world. Current models forpharmacokinetic assessment of countermeasures use African green monkeys (AGM). Arapid, sensitive and selective method was developed and validated usingLC‐MS/MS for the determination of naloxone and 6α‐naloxol in AGM plasma. Samplepreparation involved a simple solid phase extraction (SPE) using ahydrophilic‐lipophilic‐balanced reversed‐phase cartridge. Separation of naloxoneand 6α‐naloxol was achieved on a Halo C18, 2.1 × 50 mm, 2.7μ analytical columnusing an Agilent 1290 Infinity HPLC. A solvent system of methanol‐water‐formicacid was used for the elution of analytes. The analytes were detected and monitoredby a SCIEX QTRAP 6500 + triple quadrupole tandem mass spectrometer operatedin electrospray ionization (ESI) positive mode and multiple reaction monitoring(MRM). Molecular ion transitions for naloxone, 6α‐naloxol and naloxone‐D5 were 328.0/212.0,330.0/185.0, and 333.1/212.0 m/z, respectively. The method was validated usingcalibration and recovery assays with spiked samples. Linear calibration curveswere generated over the range of 1.5–100 ng/ml with values for the coefficientof determination (R 2 ) of >0.9950. The values for both inter‐dayand intra‐day precision and accuracy were well within the generally acceptedcriteria for analytical methods (≤15%). This method was subsequentlyused to measure plasma concentrations of naloxone and 6α‐naloxol in male AGMs administerednaloxone subcutaneously and intravenously. The developed method demonstratedexcellent recovery, repeatability, accuracy and sensitivity. Support or Funding Information DISCLAIMERS. The views expressed in this abstractare those of the authors (s) and do not reflect the official policy of theDepartment of Army, Department of Defense, or U. S. Government. This researchwas supported by the Defense Threat Reduction Agency – Joint Science andTechnology office, Medical S&T Division. Thisproject was supported in part by an appointment to the Research ParticipationProgram for the U.S. Army Medical Research and Materiel Command administratedby the Oak Ridge Institute for Science and Education through an agreementbetween the U.S. Army Medical Research and Materiel Command. This abstract is from the Experimental Biology 2018 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .

Bandaru, Veera Venkata Ratnam↗

Extension and validation of a method for locating damaged members in large space trusses

The damage location approach employs the control system capabilities for the structure to test the structure and measure the dynamic response. The measurements are then used in a system identification algorithm to produce a model of the damaged structure. The model is compared to one for the undamaged structure to find regions of reduced stiffness which indicate the location of damage. Kabe's 3,4 stiffness matrix adjustment method was the central identification algorithm. The strength of his method is that, with minimal data, it preserves the representation of the physical connectivity of the structure in the resulting model of the damaged truss. However, extensive storage and computational effort were required as a result. Extension of the damage location method to overcome these problems is the first part of the current work. The central system identification algorithm is replaced with the MSMT method of stiffness matrix adjustment which was previously derived by generalizing an optimal-update secant method form quasi-Newton approaches for nonlinear optimization. Validation of the extended damage location method is the second goal.

Smith, Suzanne Weaver↗

Model-Based Method for Sensor Validation

Fault detection, diagnosis, and prognosis are essential tasks in the operation of autonomous spacecraft, instruments, and in situ platforms. One of NASA s key mission requirements is robust state estimation. Sensing, using a wide range of sensors and sensor fusion approaches, plays a central role in robust state estimation, and there is a need to diagnose sensor failure as well as component failure. Sensor validation can be considered to be part of the larger effort of improving reliability and safety. The standard methods for solving the sensor validation problem are based on probabilistic analysis of the system, from which the method based on Bayesian networks is most popular. Therefore, these methods can only predict the most probable faulty sensors, which are subject to the initial probabilities defined for the failures. The method developed in this work is based on a model-based approach and provides the faulty sensors (if any), which can be logically inferred from the model of the system and the sensor readings (observations). The method is also more suitable for the systems when it is hard, or even impossible, to find the probability functions of the system. The method starts by a new mathematical description of the problem and develops a very efficient and systematic algorithm for its solution. The method builds on the concepts of analytical redundant relations (ARRs).

Vatan, Farrokh↗

Comparative Study in Laboratory Rats to Validate Sperm Quality Methods and Endpoints

Abstract The Naval Health Research Center, Detachment (Toxicology) performs toxicity studies in laboratory animals to characterize the risk of exposure to chemicals of Navy interest. Research was conducted at the Toxicology Detachment at WPAFB, OH in collaboration with Wright State University, Department of Biological Sciences for the validation of new bioassay methods for evaluating reproductive toxicity. The Hamilton Thorne sperm analyzer was used to evaluate sperm damage produced by exposure to a known testicular toxic agent, methoxyacetic acid and by inhalation exposure to JP-8 and JP-5 in laboratory rats. Sperm quality parameters were evaluated (sperm concentration, motility, and morphology) to provide evidence of sperm damage. The Hamilton Thorne sperm analyzer utilizes a DNA specific fluorescent stain (similar to flow cytometry) and digitized optical computer analysis to detect sperm cell damage. The computer assisted sperm analysis (CASA) is a more rapid, robust, predictive and sensitive method for characterizing reproductive toxicity. The results presented in this poster report validation information showing exposure to methoxyacetic acid causes reproductive toxicity and inhalation exposure to JP-8 and JP-5 had no significant effects. The CASA method detects early changes that result in reproductive deficits and these data will be used in a continuing program to characterize the toxicity of chemicals, and combinations of chemicals, of military interest to formulate permissible exposure limits.

Price, W. A.↗

On the validity of the modified equation approach to the stability analysis of finite-difference methods

The validity of the modified equation stability analysis introduced by Warming and Hyett was investigated. It is shown that the procedure used in the derivation of the modified equation is flawed and generally leads to invalid results. Moreover, the interpretation of the modified equation as the exact partial differential equation solved by a finite-difference method generally cannot be justified even if spatial periodicity is assumed. For a two-level scheme, due to a series of mathematical quirks, the connection between the modified equation approach and the von Neuman method established by Warming and Hyett turns out to be correct despite its questionable original derivation. However, this connection is only partially valid for a scheme involving more than two time levels. In the von Neumann analysis, the complex error multiplication factor associated with a wave number generally has (L-1) roots for an L-level scheme. It is shown that the modified equation provides information about only one of these roots.

Chang, Sin-Chung↗

The Second SeaWiFS HPLC Analysis Round-Robin Experiment (SeaHARRE-2)

Eight international laboratories specializing in the determination of marine pigment concentrations using high performance liquid chromatography (HPLC) were intercompared using in situ samples and a variety of laboratory standards. The field samples were collected primarily from eutrophic waters, although mesotrophic waters were also sampled to create a dynamic range in chlorophyll concentration spanning approximately two orders of magnitude (0.3 25.8 mg m-3). The intercomparisons were used to establish the following: a) the uncertainties in quantitating individual pigments and higher-order variables (sums, ratios, and indices); b) an evaluation of spectrophotometric versus HPLC uncertainties in the determination of total chlorophyll a; and c) the reduction in uncertainties as a result of applying quality assurance (QA) procedures associated with extraction, separation, injection, degradation, detection, calibration, and reporting (particularly limits of detection and quantitation). In addition, the remote sensing requirements for the in situ determination of total chlorophyll a were investigated to determine whether or not the average uncertainty for this measurement is being satisfied. The culmination of the activity was a validation of the round-robin methodology plus the development of the requirements for validating an individual HPLC method. The validation process includes the measurements required to initially demonstrate a pigment is validated, and the measurements that must be made during sample analysis to confirm a method remains validated. The so-called performance-based metrics developed here describe a set of thresholds for a variety of easily-measured parameters with a corresponding set of performance categories. The aggregate set of performance parameters and categories establish a) the overall performance capability of the method, and b) whether or not the capability is consistent with the required accuracy objectives.

Source record↗

Validation of Test Methods for Air Leak Rate Verification of Spaceflight Hardware

As deep space exploration continues to be the goal of NASAs human spaceflight program, verification of the performance of spaceflight hardware becomes increasingly critical. Suitable test methods for verifying the leak rate of sealing systems are identified in program qualification testing requirements. One acceptable method for verifying the air leak rate of gas pressure seals is the tracer gas leak detector method. In this method, a tracer gas (commonly helium) leaks past the test seal and is transported to the leak detector where the leak rate is quantified. To predict the air leak rate, a conversion factor of helium-to-air is applied depending on the magnitude of the helium flow rate. The conversion factor is based on either the molecular mass ratio or the ratio of the dynamic viscosities. The current work was aimed at validating this approach for permeation-level leak rates using a series of tests with a silicone elastomer O-ring. An established pressure decay method with constant differential pressure was used to evaluate both the air and helium leak rates of the O-ring under similar temperature and pressure conditions. The results from the pressure decay tests showed, for the elastomer O-ring, that neither the molecular flow nor the viscous flow helium-to-air conversion factors were applicable. Leak rate tests were also performed using nitrogen and argon as the test gas. Molecular mass and viscosity based helium-to-test gas conversion factors were applied, but did not correctly predict the measured leak rates of either gas. To further this study, the effect of pressure boundary conditions was investigated. Often, pressure decay leak rate tests are performed at a differential pressure of 101.3 kPa with atmospheric pressure on the downstream side of the test seal. In space applications, the differential pressure is similar, but with vacuum as the downstream pressure. The same O-ring was tested at four unique differential pressures ranging from 34.5 to 137.9 kPa. Up to six combinations of upstream and downstream pressures for each differential pressure were compared. For a given differential pressure, the various combinations of upstream and downstream dry air pressures did not significantly affect the leak rate. As expected, the leak rate of the O-ring increased with increasing differential pressure. The results suggested that the current leak test pressure conditions, used to verify spacecraft sealing systems with elastomer seals, produce accurate values even though the boundary conditions do not model the space application.

helium leak detector↗

Numerical study of boundary layer interaction with shocks: Method and code validation

A major problem in modeling of turbulent supersonic flows is the correct assessment of viscous-inviscid interaction problems. Of particular interest is the interaction of boundary layers with shocks. Present turbulence models give in most cases unsatisfactory results in the region of rapid distortion and in the separation region (if one is present) in particular with regard to mean flow profiles and turbulence quantities. The objective of the present work is the direct numerical simulation of shock boundary layer interaction. This report summarizes the first phase during which a numerical method suitable for this problem has been developed and a computer code has been written and tested.

Adams, Nikolaus A.↗

Development and Validation of Segmentation Method for Lung Cancer Volumetry on Chest CT

The set of criteria called Response Evaluation Criteria In Solid Tumors (RECIST) is used to evaluate the remedial effects of lung cancer, whereby the size of a lesion can be measured in one dimension (diameter). Volumetric evaluation is desirable for estimating the size of a lesion accurately, but there are several constraints and limitations to calculating the volume in clinical trials. In this study, we developed a method to detect lesions automatically, with minimal intervention by the user, and calculate their volume. Our proposed method, called a spherical region-growing method (SPRG), uses segmentation that starts from a seed point set by the user. SPRG is a modification of an existing region-growing method that is based on a sphere instead of pixels. The SPRG method detects lesions while preventing leakage to neighboring tissues, because the sphere is grown, i.e., neighboring voxels are added, only when all the voxels meet the required conditions. In this study, two radiologists segmented lung tumors using a manual method and the proposed method, and the results of both methods were compared. The proposed method showed a high sensitivity of 81.68–84.81% and a high dice similarity coefficient (DSC) of 0.86–0.88 compared with the manual method. In addition, the SPRG intraclass correlation coefficient (ICC) was 0.998 (CI 0.997–0.999, p < 0.01), showing that the SPRG method is highly reliable. If our proposed method is used for segmentation and volumetric measurement of lesions, then objective and accurate results and shorter data analysis time are possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gaussian kernel density functions for compositional quantification in atom probe tomography

Highlights: • A methodology for compositional quantification from atom probe tomography is proposed. • A probability density function p(x) given discrete data points is constructed. • Each atom approximated by a Gaussian function with a particular smoothing parameter. • Density Kernel functions are used to find the optimum smoothing parameter. • The method is validated by using simulated data of semiconductor materials. - Abstract: Atom probe tomography (APT) has the ability to identify the nature and position of single atoms in a material with an almost 3D atomic resolution. However, the quantification of the material composition requires an appropriate treatment of the discrete APT data. When the amount of atoms selected to quantify the composition is relatively small, the spatial resolution is enhanced but the statistical error worsens. Conversely, the increase in the number of atoms considered reduces the spatial resolution, but improving the statistics. We have developed a methodology to reach an optimum equilibrium between the positional and the statistical error in an unsupervised form using Gaussian Kernel density functions. The validity of the method has been tested using APT simulated data of semiconductor materials. It has been proved that the chemical quantification in these materials requires the appropriate selection of the smoothing parameter, obtained without user intervention. In addition, the results have been compared to the usual techniques for composition measurement from APT data (voxelization and proximity histograms), showing better precision for high spatial resolution. This work supplies a data driven methodology based in Gaussian Kernel density functions for the accurate quantification of the composition from APT data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Production of alternate realizations of DESI fiber assignment for unbiased clustering measurement in data and simulations

A critical requirement of spectroscopic large scale structure analyses is correcting for selection of which galaxies to observe from an isotropic target list. This selection is often limited by the hardware used to perform the survey which will impose angular constraints of simultaneously observable targets, requiring multiple passes to observe all of them. In SDSS this manifested solely as the collision of physical fibers and plugs placed in plates. In DESI, there is the additional constraint of the robotic positioner which controls each fiber being limited to a finite patrol radius. A number of approximate methods have previously been proposed to correct the galaxy clustering statistics for these effects, but these generally fail on small scales. To accurately correct the clustering we need to upweight pairs of galaxies based on the inverse probability that those pairs would be observed (Bianchi & Percival 2017). This paper details an implementation of that method to correct the Dark Energy Spectroscopic Instrument (DESI) survey for incompleteness. To calculate the required probabilities, we need a set of alternate realizations of DESI where we vary the relative priority of otherwise identical targets. These realizations take the form of alternate Merged Target Ledgers (AMTL), the files that link DESI observations and targets. We present the method used to generate these alternate realizations and how they are tracked forward in time using the real observational record and hardware status, propagating the survey as though the alternate orderings had been adopted. We detail the first applications of this method to the DESI One-Percent Survey (SV3) and the DESI year 1 data. We include evaluations of the pipeline outputs, estimation of survey completeness from this and other methods, and validation of the method using mock galaxy catalogs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗