Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “unbalanced system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Deep Learning-enhanced Block-Diagram Modeling of Solar Power Systems

Data-driven models of power system inverter-based resources are desired to run simulations faster than with detailed electromagnetic transient models, to hide proprietary design details, to support control system design applications, and to aggregate the effects of distributed energy resources. This paper applies a customized Hammerstein Wiener framework to train block diagram models from thousands of electromagnetic transient simulations or experimental test records. The block diagram models integrate with larger grid simulations as voltagecontrolled current sources or current-controlled voltage sources for several simulators. Guidelines for block architecture and training are presented. Three-phase balanced, three-phase unbalanced, and single-phase examples all achieve an acceptable root mean square error of no more than 0.05 per-unit.

Mcdermott, Thomas E. [Private consulting company]↗

Integrated receiver for NASA tracking and data relay satellite system

The tracking and data relay satellite system (TDRSS) provides a flexible communications system for low-earth-orbit spacecraft and a source of tracking data to permit the location of the many orbital platforms to be accessed. Central to the TDRSS ground terminal is the integrated receiver which provides data demodulation, decoding, and deinterleaving over the range of 100 sps to 12 Msps, and all the tracking services in a single high-performance design. The requirements and design of the integrated receiver (IR), as well as an unbalanced quadriphase shift keying (UQPSK) receiver/demodulator under development for use in the TDRSS are discussed. The top level architecture of the IR is presented, and the implementation of the primary functions in the receiver is described. A single IR replaces the 12 different chassis currently required to support a single S-band single-access service. This approach has proven to be successful.

Bricker, P.↗

Carrier phase recovery performance for PN-spread TDRSS link with radio-frequency interference

The carrier-phase recovery performance of a Costas loop for a nonlinear satellite channel with uplink and downlink noise is analyzed, and the extension of these results to the case where uplink radio-frequency interference (RFI) is present is considered. The signal format here is binary phase-shift-keyed (BPSK) or unbalanced quaternary phase-shift-keyed (UQPSK), the signals being either the non-return-to-zero (NRZ) or biphase (Manchester) type. With UQPSK, at least one data stream must be PN-spread. The channel comprises additive white Gaussian noise (WGN), a wideband filter, a bandpass nonlinearity and more additive WGN. The RFI being considered is pulsed continuous-wave, pulsed WGN, or a combination of the two. It is noted that the Tracking and Data Relay Satellite System (TDRSS) will be subjected to RFI from certain locations, especially in the S-band of frequencies. The characteristics of this link are generalized to form the assumptions underlying this analysis. The analytical results given include the S-curve of the equivalent loop and the phase-error variance of the linearized loop.

Mckenzie, T. M.↗

Novel Real- Time EMT- TS Modeling Architecture for Feeder Blackstart Simulations

This paper presents the development and benchmarking of a novel real-time electromagnetic-transient and transient-stability (EMT-TS) modeling architecture for distribution feeder restoration studies. The work presents for the first time in the literature a real-time EMT-TS testbed in which the grid-forming unit is simulated in EMT domain, operating as the slack bus of the phasor domain while including unbalanced voltage conditions. To evaluate the performance and limitations of the proposed model, an equivalent EMT testbed is developed to serve as a benchmark. First, the co-simulation framework and the domain coupling methodology are introduced. Next, the steady state operation of the EMT-TS and EMT models are matched. Then, tests are conducted to analyze the transient performance of the proposed EMT-TS model when compared to its EMT benchmark. Results reveal that when utilizing a battery energy storage system (BESS) as the grid-forming unit, the EMT-TS testbed can maintain high accuracy for typical load steps.

Paduani, Victor↗

Transcriptome Dynamics of the Inflorescence in Reciprocally Formed Allopolyploid Tragopogon miscellus (Asteraceae)

Polyploidy is an important evolutionary mechanism and is prevalent among land plants. Most polyploid species examined have multiple origins, which provide genetic diversity and may enhance the success of polyploids. In some polyploids, recurrent origins can result from reciprocal crosses between the same diploid progenitors. Although great progress has been made in understanding the genetic consequences of polyploidy, the genetic implications of reciprocal polyploidization remain poorly understood, especially in natural polyploids. Tragopogon (Asteraceae) has become an evolutionary model system for studies of recent and recurrent polyploidy. Allotetraploid T. miscellus has formed reciprocally in nature with resultant distinctive floral and inflorescence morphologies (i.e., short- vs. long-liguled forms). In this study, we performed comparative inflorescence transcriptome analyses of reciprocally formed T. miscellus and its diploid parents, T. dubius and T. pratensis. In both forms of T. miscellus, homeolog expression of ~70% of the loci showed vertical transmission of the parental expression patterns (i.e., parental legacy), and ~20% of the loci showed biased homeolog expression, which was unbalanced toward T. pratensis. However, 17.9% of orthologous pairs showed different homeolog expression patterns between the two forms of T. miscellus. No clear effect of cytonuclear interaction on biased expression of the maternal homeolog was found. In terms of the total expression level of the homeologs studied, 22.6% and 16.2% of the loci displayed non-additive expression in short- and long-liguled T. miscellus, respectively. Unbalanced expression level dominance toward T. pratensis was observed in both forms of T. miscellus. Significantly, genes annotated as being involved in pectin catabolic processes were highly expressed in long-liguled T. miscellus relative to the short-liguled form, and the majority of these differentially expressed genes were transgressively down-regulated in short-liguled T. miscellus. Given the known role of these genes in cell expansion, they may play a role in the differing floral and inflorescence morphologies of the two forms. In summary, the overall inflorescence transcriptome profiles are highly similar between reciprocal origins of T. miscellus. However, the dynamic homeolog-specific expression and non-additive expression patterns observed in T. miscellus emphasize the importance of reciprocal origins in promoting the genetic diversity of polyploids.

54 ENVIRONMENTAL SCIENCES↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of Accurate Modeling of Converter Interfaced Generation (CIG) on a Practical Bulk Power System

With increased penetration of converter interfaced generation (CIG) in power systems, it becomes imperative to adequately model them in both steady-state and dynamic simulations. There are several modeling approaches and simulation platforms for CIG. In addition, it is noted that suitability of modeling approaches and models is also dependent on the system conditions. However, their suitability has yet to be systematically analyzed, and this becomes a challenge in the industry without a systemic method. To tackle these challenges, in this paper, we first develop a methodology for identifying the maximum penetration of aggregated rooftop sources that can be represented as negative loads in both the steady state and dynamic analysis. Then we verify the suitability of positive-sequence performance-based model and detailed electromagnetic transient (EMT) model for utility-scale PV plants under different fault conditions. Based on the results, we perform dynamic simulations on a large practical system with both positive-sequence transient stability(TS) and EMT-TS hybrid simulation. Our study shows that positive-sequence performance based PV plant model is more suitable for study cases with faults relatively far away from the point of connection, and that positive-sequence models and TS simulation approach can produce comparable results with reference to EMT-TS hybrid simulation for normally-cleared single-line-to-ground faults, but the inadequacy of positive-sequence based model and simulation approach becomes obvious for prolonged-tripping of unbalanced faults in proximity of the PV plants.

Huang, Qiuhua↗

A Medium Voltage Testbed for the Performance and Function Tests of a 13.8 kV Power Conditioning System Converter

Medium voltage SiC devices facilitate the development of medium voltage grid-connected power electronics converters. However, it is difficult to test these converters directly on the real medium voltage grid, especially considering abnormal grid conditions, such as grid voltage and frequency variation, and different converter operation modes, such as grid-connected mode and islanded mode. This paper introduces the design and implementation of a medium voltage testbed, which supports tests of medium voltage converters in both grid-connected and islanded mode tests. In the grid-connected mode, the testbed can provide up to 13.8 kV grid voltage, can support the four-quadrant operation, and can emulate different grid conditions, such as voltage and frequency variation. In the islanded mode, the converter under test works as a voltage source and the testbed emulates a three-phase balanced or unbalanced load. Experiment test results are provided to validate the design and capability of the testbed.

Li, Haiguo↗

OPER: Optimality-Guided Embedding Table Parallelization for Large-scale Recommendation Model

With the sharp increasing volume of user data, Deep Learning Recommendation Model (DLRM) becomes an indispensable infrastructure in large technology companies. However, large-scale DLRM on the multi-GPU platform is still inefficient due to unbalanced workload partitioning and intensive inter-GPU communication. To this end, we propose OPER, an OPtimality guided Embedding table placement for large-scale Recommendation model training and inference. OPER explores the potential of mitigating remote memory access latency in DLRM through fine-grained embedding table placement. Specifically, OPER proposes a theoretical modeling that builds up the relationship between EMT placement and the embedding communication latency in both training and inference. OPER proves the NP hardness of finding the optimal embedding table placement and proposes a heuristic algorithm that yields near optimal placement. OPER implements a SHMEM-based embedding table training system and a unified embedding index mapping to support fine-grained embedding table sharding and placement. Comprehensive experiments reveal that OPER achieves on average 3.4× and 5.1× speedup on training and inference respectively over state-of-the-art DLRM frameworks.

Wang, Zheng↗

Pointing and Scanning Control of Optical Instruments using Rotating Unbalanced Masses

Correct pointing direction and scanning motions are essential in the operation of many flight payloads, such as balloon-borne telescopes and space-based X- ray and gamma-ray telescopes. Rotating unbalanced mass (RUM) devices have been recently proposed, implemented and successfully tested to produce a variety of scanning motions. Linear scans, raster scans, and circular scans have been successfully generated on a gimbaled payload using pairs of RUM devices. Theoretical analysis, computer simulations, and experiments have also been used to study the feasibility of using RUM devices to control instrument pointing direction, in addition to generating scanning motion. Dynamic modeling of a gimbaled payload equipped with a pair of RUM devices has been studied, and preliminary testing indicates that the pointing control is indeed feasible. However, there is also great potential for significant performance improvements through more advanced control system analysis, modeling and design. In this paper, modeling and control methods are described to achieve simultaneous scanning and pointing control of a gimbaled payload using rotating unbalance mass (RUM) devices. The model development work builds upon the results of Polites et al. and also some modeling approaches from robotics research. Results of some preliminary experiments are discussed and some nonlinear control methods will be proposed.

Bishop, Carlee A.↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop and instability if the VI is not adaptive. Simulation results of various unbalanced faults with high- and low-fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high- and low-fault impedances.

adaptive virtual impedance control↗

Particle Velocity Measuring System

Method and apparatus are provided for determining the velocity of individual food particles within a liquid/solid food mixture that is cooked by an aseptic cooking method whereby the food mixture is heated as it flows through a flowline. At least one upstream and at least one downstream microwave transducer are provided to determine the minimum possible travel time of the fastest food particle through the flowline. In one embodiment, the upstream detector is not required. In another embodiment, a plurality of small dipole antenna markers are secured to a plurality of food particles to provide a plurality of signals as the markers pass the upstream and downstream transducers. The dipole antenna markers may also include a non-linear element to reradiate a harmonic frequency of a transmitter frequency. Upstream and downstream transducers include dipole antennas that are matched to the impedance of the food slurry and a signal transmission cable by various impedance matching means including unbalanced feed to the antennas.

Arndt, G. Dickey↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through (FRT) capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop, and the instability if the VI is not adaptive. Simulation results of various unbalanced faults with high and low fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high and low fault impedances.

adaptive virtual impedance control↗

Buckling Behavior of Long Anisotropic Plates Subjected to Elastically Restrained Thermal Expansion and Contraction

An approach for synthesizing buckling results for thin balanced and unbalanced symmetric laminates that are subjected to uniform heating or cooling and elastically restrained against thermal expansion or contraction is presented. This approach uses a nondimensional analysis for infinitely long, flexural anisotropic plates that are subjected to combined mechanical loads. In addition, stiffness-weighted laminate thermal-expansion parameters and compliance coefficients are derived that are used to determine critical temperatures in terms of physically intuitive mechanical-buckling coefficients. Many results are presented for some common laminates that are intended to facilitate a structural designer s transition to the use of the generic buckling design curves. Several curves that illustrate the fundamental parameters used in the analysis are presented, for nine contemporary material systems, that provide physical insight into the buckling response in addition to providing useful design data. Examples are presented that demonstrate the use of the generic design curves.

Nemeth, Michael P.↗

Impact of Inverter-Based Resources on Grid Protection: A Review of Negative-Sequence Current Generation

The increasing integration of inverter-based resources (IBRs) in power grids poses challenges to traditional protection systems, primarily due to their different fault current signatures compared to conventional synchronous generators. Unlike synchronous generators whose fault response is dictated by their physical design, IBRs exhibit a wide range of fault characteristics due to manufacturer-specific control algorithms and settings. This dependence on proprietary control schemes makes modeling IBR behavior during faults significantly more complex, especially considering the rapid evolution of inverter technology and the diverse control strategies employed. While much research has focused on the positive-sequence current injections of IBRs during symmetrical faults, the understanding of negative-sequence current generation during non-symmetrical faults remains limited. This report provides an overview of current research on IBRs' negative-sequence current generation during unbalanced faults and its impact on protection schemes based on negative-sequence components. It covers both type III wind turbines and full-size converter-based IBRs. Additionally, this report reviews strategies for grid-forming controlled inverters to generate negative-sequence current during unbalanced faults, in addition to grid-following controlled ones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fiber-Optic Pressure Sensor With Dynamic Demodulation Developed

Researchers at the NASA Glenn Research Center developed in-house a method to detect pressure fluctuations using a fiber-optic sensor and dynamic signal processing. This work was in support of the Intelligent Systems Controls and Operations project under NASA's Information Technology Base Research Program. We constructed an optical pressure sensor by attaching a fiber-optic Bragg grating to a flexible membrane and then adhering the membrane to one end of a small cylinder. The other end of the cylinder was left open and exposed to pressure variations from a pulsed air jet. These pressure variations flexed the membrane, inducing a strain in the fiber-optic grating. This strain was read out optically with a dynamic spectrometer to record changes in the wavelength of light reflected from the grating. The dynamic spectrometer was built in-house to detect very small wavelength shifts induced by the pressure fluctuations. The spectrometer is an unbalanced interferometer specifically designed for maximum sensitivity to wavelength shifts. An optimum pathlength difference, which was determined empirically, resulted in a 14-percent sensitivity improvement over theoretically predicted path-length differences. This difference is suspected to be from uncertainty about the spectral power difference of the signal reflected from the Bragg grating. The figure shows the output of the dynamic spectrometer as the sensor was exposed to a nominally 2-kPa peak-to-peak square-wave pressure fluctuation. Good tracking, sensitivity, and signal-to-noise ratios are evident even though the sensor was constructed as a proof-of-concept and was not optimized in any way. Therefore the fiber-optic Bragg grating, which is normally considered a good candidate as a strain or temperature sensor, also has been shown to be a good candidate for a dynamic pressure sensor.

Lekki, John D.↗

Monitoring techniques for the X-29A aircraft's high-speed rotating power takeoff shaft

The experimental X-29A forward swept-wing aircraft has many unique and critical systems that require constant monitoring during ground or flight operation. One such system is the power takeoff shaft, which is the mechanical link between the engine and the aircraft-mounted accessory drive. The X-29A power takeoff shaft opertes in a range between 0 and 16,810 rpm, is longer than most jet engine power takeoff shafts, and is made of graphite epoxy material. Since the X-29A aircraft operates on a single engine, failure of the shaft during flight could lead to loss of the aircraft. The monitoring techniques and test methods used during power takeoff shaft ground and flight operations are discussed. Test data are presented in two case studies where monitoring and testing of the shaft dynamics proved instrumental in discovering and isolating X-29A power takeoff shaft problems. The first study concerns the installation of an unbalanced shaft. The effect of the unbalance on the shaft vibration data and the procedure used to correct the problem are discussed. The second study deals with the shaft exceeding the established vibration limits during flight. This case study found that the vibration of connected rotating machinery unbalances contributed to the excessive vibration level of the shaft. The procedures used to identify the contributions of other rotating machinery unbalances to the power takeoff shaft unbalance are discussed.

Voracek, David F.↗

Buckling Behavior of Long Anisotropic Plates Subjected to Elastically Restrained Thermal Expansion

An approach for synthesizing buckling results for, and behavior of, thin balanced and unbalanced symmetric laminates that are subjected to uniform heating or cooling and elastically restrained against thermal expansion or contraction is presented. This approach uses a nondimensional analysis for infinitely long, flexurally anisotropic plates that are subjected to combined mechanical loads and is based on useful nondimensional parameters. In addition, stiffness-weighted laminate thermal-expansion parameters and compliance coefficients are derived that are used to determine critical temperatures in terms of physically intuitive mechanical-buckling coefficients. The effects of membrane orthotropy and membrane anisotropy are included in the general formulation. Many results are presented for some common laminates that are intended to facilitate a structural designer's transition to the use of generic buckling design curves. Several curves that illustrate the fundamental parameters used in the analysis are presented, for nine contemporary material systems, that provide physical insight into the buckling response in addition to providing useful design data. Examples are presented that demonstrate the use of generic design curves. The analysis approach and generic results indicate the effects and characteristics of elastically restrained laminate thermal expansion or contraction, membrane orthotropy and anisotropy, and flexural orthotropy and anisotropy in a very general and unifying manner.

Nemeth, Michael P.↗