Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient behavior”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Peculiar Behaviors of Faint Galactic Bulge Transients

The Rossi X-ray Timing Explorer PCA scans of the Galactic bulge (galactic longitude plus or minus 11 degrees) have detected 8 recent transients which have peak intensities of 10 to 400 mCrab. Some of the transient events have a fast rise and slow decay typical of accretion disk instabilities. It is common for these decays to be oscillatory, rather than steady, as if there are waves within the disk. There are also outbursts with symmetric light curves. In particular, the source in Terzan 2 which had a very long (decade) doubling of intensity peaking near the beginning of 1997, in 2004 has had two 30 day brightenings by a factor of 5 only 100 days apart. During each of these a burst was observed in snapshot observations near the peak. The source SLX 1735-269, also a burster, though not in our observations, has had irregularly repeated occurrences of fast swings between close to zero and 2-4 times normal. Some examples, such as the increase, drop, and slow recovery of GS 1826-238 suggest a change in the accretion disk such as emptying and refilling or a peculiar alignment. Follow up observations have provided deeper information about these transient sources and possible explanations for their behavior will be addressed.

Swank, J. H.↗

The Solsticial Pause on Mars: A Planetary Wave Reanalysis - Part 1

Large-scale planetary waves are diagnosed from an analysis of profiles retrieved from the Thermal Emission Spectrometer aboard the Mars Global Surveyor spacecraft during its scientific mapping phase. The analysis is conducted by assimilating thermal profiles and total dust opacity retrievals into a Mars global circulation model. Transient waves are largest throughout the northern hemisphere autumn, winter and spring period and almost absent during the summer. The southern hemisphere exhibits generally weaker transient wave behavior. A striking feature of the low-altitude transient waves in the analysis is that they show a broad subsidiary minimum in amplitude centred on the winter solstice, a period when the thermal contrast between the summer hemisphere and the winter pole is strongest and baroclinic wave activity might be expected to be strong. This behavior, here called the 'solsticial pause,' is present in every year of the analysis. This strong pause is under-represented in many independent model experiments, which tend to produce relatively uniform baroclinic wave activity throughout the winter. This paper documents and diagnoses the transient wave solsticial pause found in the analysis; a companion paper investigates the origin of the phenomenon in a series of model experiments.

Lewis, Stephen R.↗

Magnetohydrodynamics of atmospheric transients. I - Basic results of two-dimensional plane analyses

The dynamic behavior of transients in a stratified atmosphere in the presence of a magnetic field is investigated with the two-dimensional plane formulation, i.e., the formulation in which variations of the flow and magnetic field are confined within a plane. It is pointed out that, in the plane formulation, the noncompressible transverse waves (often called the Alfven waves) are excluded. The compressible responses of the atmosphere are then examined with a temperature perturbation (simulating a sudden local release of energy by a flare) as functions of the configuration of magnetic field and field strength. It is shown that (1) in the open (mostly radial) magnetic field, the propagation of 'bubble-like' density enhancements, the coronal transients, result; while (2) in the closed (mostly azimuthal) field, the density enhancement forms a pair of 'horns' near the foot points of field lines similar to that often observed by coronagraphs after flares. Discussions in interpreting the results in terms of the anisotropic propagation of the fast and slow waves (or shocks) are presented together with consideration of possible consequences with the inclusion of the transverse waves.

Nakagawa, Y.↗

Behavior of 2-Cell CPV Ni-H2 Battery During Pulse Discharge

A study was carried out to determine the transient voltage behavior of the 2-cell CPV nickel-hydrogen battery with the objective of using the results as a basis for mathematical modeling. The 2-cell CPV battery which is manufactured by Eagle Picher, Inc. for the GOES program yields 18.5 Ah at C/2 rate of discharge at 10 C with a mid-discharge voltage of 2.514 V. The capacity increased with decrease of temperature and a maximum capacity of 22 Ah was obtained at -5 C. The pulse tests consisted of obtaining the voltage profile in the first 20 milliseconds of the one minute pulse discharge at 37 A and pulse discharge was repeated as a function of state- of- charge. The pulse test at 10 C and 20 C provided voltage profiles with the expected decrease in voltage as the pulse was applied. The end of pulse voltage decreased with the state-of-charge. The battery voltage was above 2V at the end of the one-minute pulse at 8 % state-of-charge at 10 C. The voltage profile during the 37 A pulse discharge consists of an initial drop in voltage which was independent of the state of charge. The invariability in the value for the initial drop in voltage with state of charge is a very important observation. The results show that towards the end of discharge the dominant resistance is not ohmic in nature. It could be hypothesized from the nature of the voltage transients that the dominant mechanism towards the end of discharge is proton diffusion. The study also shows that the dominant resistance in the voltage plateau during discharge is activation polarization.

Vaidyanathan, Hari↗

Behavior of 2 Cell CPV NI-H2 Battery During Pulse Discharge

A study was carried out to determine the transient voltage behavior of the 2-cell CPV nickel-hydrogen battery with the objective of using the results as a basis for mathematical modeling. The 2-cell CPV battery which is manufactured by Eagle Picher, Inc. for the GOES program yields 18.5 Ah at C/2 rate of discharge at 10 C with a mid-discharge voltage of 2.514 V. The capacity increased with decrease of temperature and a maximum capacity of 22 Ah was obtained at - 5 C. The pulse test consisted of obtaining the voltage profile in the first 20 milliseconds of the one minute pulse discharge at 37 A and pulse discharge was repeated as a function of state-of-charge. The pulse test at 10 C and 20 C provided voltage profiles with the expected decrease in voltage as the pulse was applied. The end of pulse voltage decreased with the state-of-charge. The battery voltage was above 2V at the end of the one-minute pulse at 12% state-of-charge at 10 C. The voltage profile during the 37 A pulse discharge consists of an initial drop in voltage which was independent of the state of charge. The invariability in the value for the initial drop in voltage with state of charge is a very important observation and indicates that towards the end of discharge the dominant resistance is not ohmic in nature. It could be hypothesized from the nature of the voltage transients that the dominant mechanism towards the end of discharge is proton diffusion. The study also shows that the dominant resistance in the voltage plateau during discharge is activation polarization.

Gopalakrishna, M. Rao↗

Behavior of 2-Cell CPV Ni-H2 Battery During Pulse Discharge

A study was carried out to determine the transient voltage behavior of the 2-cell CPV nickel-hydrogen battery with the objective of using the results as a basis for mathematical modeling. The 2-cell CPV battery which is manufactured by Eagle Picher, Inc. for the GOES program yields 18.5 Ah at C/2 rate of discharge at 10 C with a mid-discharge voltage of 2.514 V. The capacity increased with decrease of temperature and a maximum capacity of 22 Ah was obtained at -5 C. The pulse tests consisted of obtaining the voltage profile in the first 20 milliseconds of the one minute pulse discharge at 37 A and pulse discharge was repeated as a function of state-of-charge. The pulse test at 10 C and 20 C provided voltage profiles with the expected decrease in voltage as the pulse was applied. The end of pulse voltage decreased with the state-of-charge. The battery voltage was above 2V at the end of the one-minute pulse at 8 % state-of-charge at 10 C. The voltage profile during the 37 A pulse discharge consists of an initial drop in voltage which was independent of the state of charge. The invariability in the value for the initial drop in voltage with state of charge is a very important observation. The results show that towards the end of discharge the dominant resistance is not ohmic in nature. It could be hypothesized from the nature of the voltage transients that the dominant mechanism towards the end of discharge is proton diffusion. The study also shows that the dominant resistance in the voltage plateau during discharge is activation polarization.

Vaidyanathan, Hari↗

Transient modeling of the thermohydraulic behavior of high temperature heat pipes for space reactor applications

Many proposed space reactor designs employ heat pipes as a means of conveying heat. Previous researchers have been concerned with steady state operation, but the transient operation is of interest in space reactor applications due to the necessity of remote startup and shutdown. A model is being developed to study the dynamic behavior of high temperature heat pipes during startup, shutdown and normal operation under space environments. Model development and preliminary results for a hypothetical design of the system are presented.

Hall, Michael L.↗

Modeling of environmentally induced transients within satellites

A technique is described that allows an estimation of possible spacecraft charging hazards. This technique, called SCREENS (spacecraft response to environments of space), utilizes the NASA charging analyzer program (NASCAP) to estimate the electrical stress locations and the charge stored in the dielectric coatings due to spacecraft encounter with a geomagnetic substorm environment. This information can then be used to determine the response of the spacecraft electrical system to a surface discharge by means of lumped element models. The coupling into the electronics is assumed to be due to magnetic linkage from the transient currents flowing as a result of the discharge transient. The behavior of a spinning spacecraft encountering a severe substorm is predicted using this technique. It is found that systems are potentially vulnerable to upset if transient signals enter through the ground lines.

Stevens, N. John↗

Laminar diffusion flames under micro-gravity conditions

Laminar methane and propane gas-jet diffusion flames have been theoretically and experimentally studied at NASA-Lewis under microgravity conditions. It is noted that laminar diffusion flames are strongly affected by the combined effects of kinetics, radiation, and such transient phenomena as flame ignition, stabilization, and extinction. Observations on the distinctive nature of the flame color and luminosity parameters in microgravity are presented, and flame behavior under transient, high-deceleration rates is discussed. Test hardware and instrumentation design are described.

Edelman, Raymond B.↗

Dynamic Simulation of a Wave Rotor Topped Turboshaft Engine

The dynamic behavior of a wave rotor topped turboshaft engine is examined using a numerical simulation. The simulation utilizes an explicit, one-dimensional, multi-passage, CFD based wave rotor code in combination with an implicit, one-dimensional, component level dynamic engine simulation code. Transient responses to rapid fuel flow rate changes and compressor inlet pressure changes are simulated and compared with those of a similarly sized, untopped, turboshaft engine. Results indicate that the wave rotor topped engine responds in a stable, and rapid manner. Furthermore, during certain transient operations, the wave rotor actually tends to enhance engine stability. In particular, there is no tendency toward surge in the compressor of the wave rotor topped engine during rapid acceleration. In fact, the compressor actually moves slightly away from the surge line during this transient. This behavior is precisely the opposite to that of an untopped engine. The simulation is described. Issues associated with integrating CFD and component level codes are discussed. Results from several transient simulations are presented and discussed.

Greendyke, R. B.↗

A fine-wire thermocouple probe for measurement of stagnation temperatures in real gas hypersonic flows of nitrogen

A fine-wire thermocouple probe was used to determine freestream stagnation temperatures in hypersonic flows. Data were gathered in a N2 blowdown wind tunnel with runtimes of 1-5 s. Tests were made at supply pressures between 30 and 1400 atm and supply temperatures between 700 and 1900 K, with Mach numbers of 14 to 16. An iterative procedure requiring thermocouple data, pilot pressure measurements, and supply conditions was used to determine test cell stagnation temperatures. Probe conduction and radiation losses, as well as real gas behavior of N2, were accounted for during analysis. Temperature measurement error was found to be 5 to 10 percent. A correlation was drawn between thermocouple diameter Reynolds number and temperature recovery ratio. Transient probe behavior was studied and was found to be adequate in temperature gradients up to 1000 K/s.

Hollis, Brian R.↗

Testing of Two-Speed Transmission Configurations for Use in Rotorcraft

Large civil tiltrotors have been identified to replace regional airliners over medium ranges to alleviate next-generation air traffic. Variable rotor speed for these vehicles is required for efficient high-speed operation. Two-speed drive system research has been performed to support these advanced rotorcraft applications. Experimental tests were performed on two promising two-speed transmission configurations. The offset compound gear (OCG) transmission and the dual star/idler (DSI) planetary transmission were tested in the NASA Glenn Research Center variable-speed transmission test facility. Both configurations were inline devices with concentric input and output shafts and designed to provide 1:1 and 2:1 output speed reduction ratios. Both were designed for 200 hp and 15,000 rpm input speed and had a dry shift clutch configuration. Shift tests were performed on the transmissions at input speeds of 5,000, 8,000, 10,000, 12,500, and 15,000 rpm. Both the OCG and DSI configurations successfully perform speed shifts at full rated 15,000 rpm input speed. The transient shifting behavior of the OCG and DSI configurations were very similar. The shift clutch had more of an effect on shifting dynamics than the reduction gearing configuration itself since the same shift clutch was used in both configurations. For both OCG and DSI configurations, low-to-high speed shifts were limited in applied torque levels in order to prevent overloads on the transmission due to transient torque spikes. It is believed that the relative lack of appreciable slippage of the dry shifting clutch at operating conditions and pressure profiles tested was a major cause of the transient torque spikes. For the low-to-high speed shifts, the output speed ramp-up time slightly decreased and the peak out torque slightly increased as the clutch pressure ramp-down rate increased. This was caused by slightly less clutch slippage as the clutch pressure ramp-down rate increased.

Lewicki, David G.↗

Transient Response to Rapid Cooling of a Stainless Steel Sodium Heat Pipe

Compact fission power systems are under consideration for use in long duration space exploration missions. Power demands on the order of 500 W, to 5 kW, will be required for up to 15 years of continuous service. One such small reactor design consists of a fast spectrum reactor cooled with an array of in-core alkali metal heat pipes coupled to thermoelectric or Stirling power conversion systems. Heat pipes advantageous attributes include a simplistic design, lack of moving parts, and well understood behavior. Concerns over reactor transients induced by heat pipe instability as a function of extreme thermal transients require experimental investigations. One particular concern is rapid cooling of the heat pipe condenser that would propagate to cool the evaporator. Rapid cooling of the reactor core beyond acceptable design limits could possibly induce unintended reactor control issues. This paper discusses a series of experimental demonstrations where a heat pipe operating at near prototypic conditions experienced rapid cooling of the condenser. The condenser section of a stainless steel sodium heat pipe was enclosed within a heat exchanger. The heat pipe - heat exchanger assembly was housed within a vacuum chamber held at a pressure of 50 Torr of helium. The heat pipe was brought to steady state operating conditions using graphite resistance heaters then cooled by a high flow of gaseous nitrogen through the heat exchanger. Subsequent thermal transient behavior was characterized by performing an energy balance using temperature, pressure and flow rate data obtained throughout the tests. Results indicate the degree of temperature change that results from a rapid cooling scenario will not significantly influence thermal stability of an operating heat pipe, even under extreme condenser cooling conditions.

Mireles, Omar R.↗

Alkali metal pool boiler life tests for a 25 kWe advanced Stirling conversion system

The overall operating temperature and efficiency of solar-powered Stirling engines can be improved by adding an alkali metal pool boiler heat transport system to supply heat more uniformly to the heater head tubes. One issue with liquid metal pool boilers is unstable boiling. Stable boiling is obtained with an enhanced boiling surface containing nucleation sites that promote continuous boiling. Over longer time periods, it is possible that the boiling behavior of the system will change. An 800-h life test was conducted to verify that pool boiling with the chosen fluid/surface combination remains stable as the system ages. The apparatus uses NaK boiling on a - 100 + 140 stainless steel sintered porous layer, with the addition of a small amount of xenon. Pool boiling remained stable to the end of life test. The pool boiler life test included a total of 82 cold starts, to simulate startup each morning, and 60 warm restarts, to simulate cloud cover transients. The behavior of the cold and warm starts showed no significant changes during the life test. In the experiments, the fluid/surface combination provided stable, high-performance boiling at the operating temperature of 700 C. Based on these experiments, a pool boiler was designed for a full-scale 25-kWe Stirling system.

Anderson, W. G.↗

A Performance Prediction Model for a Fault-Tolerant Computer During Recovery and Restoration

The modeling and design of a fault-tolerant multiprocessor system is addressed. In particular, the behavior of the system during recovery and restoration after a fault has occurred is investigated. Given that a multicomputer system is designed using the Algorithm to Architecture to Mapping Model (ATAMM), and that a fault (death of a computing resource) occurs during its normal steady-state operation, a model is presented as a viable research tool for predicting the performance bounds of the system during its recovery and restoration phases. Furthermore, the bounds of the performance behavior of the system during this transient mode can be assessed. These bounds include: time to recover from the fault (t(sub rec)), time to restore the system (t(sub rec)) and whether there is a permanent delay in the system's Time Between Input and Output (TBIO) after the system has reached a steady state. An implementation of an ATAMM based computer was developed with the Generic VHSIC Spaceborne Computer (GVSC) as the target system. A simulation of the GVSC was also written based on the code used in ATAMM Multicomputer Operating System (AMOS). The simulation is in turn used to validate the new model in the usefulness and accuracy in tracking the propagation of the delay through the system and predicting the behavior in the transient state of recovery and restoration. The model is validated as an accurate method to predict the transient behavior of an ATAMM based multicomputer during recovery and restoration.

Stoughton, John W.↗

Hybrid-Electric Aero-Propulsion Controls Testbed Results

NASA is supporting the development of Electrified Aircraft Propulsion (EAP) technology due to its potential to reduce aircraft fuel burn, emissions, and noise as well as improving safety and performance. One focus of this research is the electrification of conventional turbomachinery propulsion systems, which offers ways to improve the performance and operability of turbine-engine powered aircraft through the addition of electro-mechanical systems. These hybrid-electric turbine engines provide additional actuation and energy management control opportunities for improving stability and transient response behavior. This paper summarizes the results of a Hardware-in-the-Loop (HIL) test performed at the NASA Electric Aircraft Testbed (NEAT) during the summer of 2022. The test demonstrates the feasibility and performance of an advanced energy management control strategy by integrating a simulated turbofan engine with scaled electro-mechanical hardware. A full-scale real-time reference model of a geared turbofan was run alongside a scaled electro-mechanical system representing the electrified turbofan components operating at a megawatt-scale power level. The model was interfaced with the hardware through a novel closed-loop control and scaling algorithm that emulated the dynamic speed and torque response of the turbofan shafts. The control strategy was implemented on the electrical machines connected to the emulated turbomachinery shafts. The results from the testbed are compared against simulations that predict the testbed and geared turbofan model operation. The energy management control strategy successfully changed the operating point of the engine model and improved its stability during throttle transients. These results also demonstrate the success of the novel closed loop control and scaling approach for emulating turbomachinery and elevate the Technology Readiness Level (TRL) of the energy management control strategy.

Aeronautics↗