Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Limits on the Low-energy Electron Antineutrino Flux from the Brightest Gamma-Ray Burst of All Time

The electron antineutrino flux limits are presented for the brightest gamma-ray burst (GRB) of all time, GRB221009A, over a range of 1.8–200 MeV using the Kamioka Liquid Scintillator Antineutrino Detector. Using multiple time windows ranging from minutes to days surrounding the event to search for electron antineutrinos coincident with the GRB, we set an upper limit on the flux under the assumption of several power-law neutrino source spectra, with power-law indices ranging from 1.5 to 3 in steps of 0.5. No excess was observed in any time windows ranging from seconds to days around the event trigger time T 0 . For a power-law index of 2 and a time window of T 0 ± 500 s, a flux upper limit of 2.34 × 10 9 cm −2 was calculated. The limits are compared to the results presented by IceCube.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of limited coverage effects on areal density measurements in inertial confinement fusion implosions

Accurate diagnosis of areal density ($\textit{ρR}$) is critical for the inference of performance metrics in inertial confinement fusion implosions. One potential source of error in this diagnosis is the existence of low mode perturbations in the imploding target, which lead to asymmetries in the inference of the $\textit{ρR}$ from different lines of sight. Here, the error accrued as a result of limited coverage of the sphere due to a finite number of detectors is quantified, and the development of a forward scatter measurement from the OMEGA neutron time-of-flight detectors is motivated. In this work, a method by which the 1D-equivalent 4 π-averaged $\langleρR\rangle$ can be reconstructed, if accurate mode information can be diagnosed by other means, is validated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved Limits on Millicharged Particles Using the ArgoNeuT Experiment at Fermilab

A search for millicharged particles, a simple extension of the standard model, has been performed with the ArgoNeuT detector exposed to the Neutrinos at the Main Injector beam at Fermilab. The ArgoNeuT liquid argon time projection chamber detector enables a search for millicharged particles through the detection of visible electron recoils. We search for an event signature with two soft hits (MeV-scale energy depositions) aligned with the upstream target. For an exposure of the detector of 1.0×10 20 protons on target, one candidate event has been observed, compatible with the expected background. This search is sensitive to millicharged particles with charges between 10 -3 $e$ and 10 -1 $e$ and with masses in the range from 0.1 to 3 GeV. This measurement provides leading constraints on millicharged particles in this large unexplored parameter space region.

43 PARTICLE ACCELERATORS↗

Timing and synchronization of the DUNE neutrino detector

The DUNE neutrino experiment far detector has a fiducial mass of 40 kt. The O(1 M) readout channels are distributed over the 4 x 10kt modules and need to be synchronized to O(10 ns) with a reliable, simple, affordable system. For the majority of channels a simple DC-balanced protocol is used, with clock and synchronization information encoded on the same fibre. The remaining channels use “White Rabbit” (IEEE-1588). Small scale tests show a timing jitter of <100 ps. The DUNE timing system has been successfully prototyped at the ProtoDUNE-SP detector at CERN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FCC-ee interaction region backgrounds

The FCC-ee machine induced backgrounds on the two proposed detectors (CLD and IDEA) have been studied in detail. Synchrotron Radiation (SR) considerations dictate the Interaction Region (IR) optimization. An asymmetric IR design limits the final bend critical energy to 100 keV. Masks placed before the final focus quadrupole protect the detector from direct hits, and a shield placed around the beam pipe from secondary particles, keeping the effect of SR on the detector to negligible levels. The most important source of background is expected to be the Incoherent Pair Creation (IPC). Its effect has been studied in full simulation and reconstruction, and it was shown that it will not pose a problem for the detector, even if conservative estimations for the time resolution of the detector sensors are assumed. Moreover, the γγ → hadrons, radiative Bhabhas and beam-gas interaction induced backgrounds were studied. All were found to have small to negligible effect on the detector. Finally overall, the FCC–ee interaction region backgrounds are not expected to compromise the detector performance.

47 OTHER INSTRUMENTATION↗

Separating beam-induced and cosmogenic muon backgrounds in the ICARUS detector

Due to high cosmic ray flux near the earth's surface, the rejection of cosmogenic muon backgrounds is a preeminent concern for particle detectors using Liquid Argon Time Projection Chamber (LArTPC) technology. One such detector, ICARUS of the short baseline neutrino experiment, also observes muons generated from neutrino interactions with nuclei in the surrounding rock. Our analysis exploits the differences between cosmogenic and rock-generated muons to separate rock-generated muons from the background. We develop a selection with 96.5\% efficiency and 81\% accuracy. Use of this selection on data and Monte-Carlo indicates monte-carlo may underestimate the true rock muon flux. These results have implications for calibration of the ICARUS detector and tuning of simulation.

Wells, David↗

Using quantum noise correlation analysis to measure ion temperature

Quantum noise correlation analysis was tested at the proof-of-concept level as a technique to measure ion temperature in a plasma. If eventually successful, this technique could enable a compact, inexpensive, and robust ion temperature diagnostic suitable for a burning plasma environment. Ion temperature is a key parameter determining the fusion performance of a burning plasma, as the fusion cross-section has a strong dependence on ion temperature. This ion temperature diagnostic would require only a small optical view of the plasma through a port to passively record impurity line emission. The instrumentation would be remote from the reactor behind the neutron and bio-shielding. The technique relies solely on quantum correlations of the photons emitted by a plasma impurity to measure ion temperature; there is no grating dispersion of an emission line-width or pulse-height analysis of photon energy. This measurement innovation was tested with instrumentation consisting of two single-photon detectors with high timing resolution, a time-tagging unit, and simple light collection optics. This instrumentation measures the second-order correlation between the light intensity falling on the two detectors. The next steps beyond the proof-of-concept level will be development of diagnostic designs for application of this technique to high-temperature and burning plasmas. Arrays of single-photon avalanche detectors to multiplex measurements of photon correlation will be required to reduce signal integration time to an acceptable duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-performance Generic Neutrino Detection in a LArTPC near the Earth&#x27;s Surface with the MicroBooNE Detector

Large Liquid Argon Time Projection Chambers (LArTPCs) are being increasingly adopted in neutrino oscillation experiments because of their superb imaging capabilities through the combination of both tracking and calorimetry in a fully active volume. Active LArTPC neutrino detectors at or near the Earth's surface, such as the MicroBooNE experiment, present a unique analysis challenge because of the large flux of cosmic-ray muons and the slow drift of ionization electrons. We present a novel Wire-Cell-based high-performance generic neutrino-detection technique implemented in MicroBooNE. The cosmic-ray background is reduced by a factor of 1.4$\times10^{5}$ resulting in a 9.7% cosmic contamination in the selected neutrino candidate events, for visible energies greater than 200~MeV, while the neutrino signal efficiency is retained at 88.4% for $\nu_{\mu}$ charged-current interactions in the fiducial volume in the same energy region. This significantly improved performance compared to existing reconstruction algorithms, marks a major milestone toward reaching the scientific goals of LArTPC neutrino oscillation experiments operating near the Earth's surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time mixed reality display of dual particle radiation detector data

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated ’hot spots’ are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user’s 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source’s angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real Time implementation of Artificial Intelligence compression algorithm for High-Speed Streaming Readout signals

The new generation of high-energy physics experiments plans to acquire data in streaming mode. With this approach, it is possible to access the information of the whole detector (organized in time slices) for optimal and lossless triggering of data acquisitions. With this approach, data rates, especially in large detectors, are often very high, and the network is likely to be the bottleneck for the entire Streaming Read Out system. The aim of this work is to study the implementation of a lossy compression algorithm based on Artificial Intelligence: an Autoencoder. With Machine Learning it is possible to achieve a high compression ratio and fast inference time with only a small degradation of the signals, almost negligible for the specific application. This work explores different configurations of the Autoencoder and the implementation on different hardware. Different Autoencoder configurations are explored to find the best trade-off between compression ratio and reconstruction loss, both for signals and energy spectrum. Different hardware implementations are also explored to find the best platform to achieve real-time performance for the specific application.

Rossi, Fabio (ORCID:0009000385713885)↗

A New Scheme of Redundant Timing Crosschecking for Frontend Systems

In high energy physics experiments, frontend digitization modules are usually driven by a common clock. At the frontend electronics and digitization modules of the detector, a precise timing reference must establish in order to make a useful timing measurement. It would be very useful for the frontend digitization system to include a feature of redundant timing crosschecking. The inspiration for the timing crosschecking scheme came from the long-abandoned analog mean-timer schemes. In this scheme, several Front-end modules are connected together through a cable set with taps connected to the digitization modules. Pulses are driven from every FE modules alternately without overlapping. The arrival times of pulses sent from FE modules are digitized at the timing crosschecking module. The mean times will change as temperature changes, but their difference between two FE modules are cancelled mathematically. This feature enables easy achievement of good timing precision without the need for complex hardware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-of-flight methodologies with large-area diamond detectors for the effectively characterization of tens MeV protons

A novel detector based on a polycrystalline diamond sensor is here employed in an advanced time-of-flight scheme for the characterization of energetic ions accelerated during laser-matter interactions. The optimization of the detector and of the advanced TOF methodology allow to obtain signals characterized by high signal-to-noise ratio and high dynamic range even in the most challenging experimental environments, where the interaction of high-intensity laser pulses with matter leads to effective ion acceleration, but also to the generation of strong Electromagnetic Pulses (EMPs) with intensities up to the MV/m order. These are known to be a serious threat for the fielded diagnostic systems. Here we report on the measurement performed with the PW-class laser system Vega 3 at CLPU (~30 J energy, ~10 21 W/cm 2 intensity, ~30 fs pulses) irradiating solid targets, where both tens of MeV ions and intense EMP fields were generated. The data were analyzed to retrieve a calibrated proton spectrum and in particular we focus on the analysis of the most energetic portion (E > 5.8 MeV) of the spectrum showing a procedure to deal with the intrinsic lower sensitivity of the detector in the mentioned spectral-range.

47 OTHER INSTRUMENTATION↗

Charged Current Coherent Pion Production Cross-Section Measurement at MicroBooNE

Coherent pion production, characterized by a neutrino interacting with an entire nucleus without breaking it apart, results in a forward-going muon, pion, and a low-momentum recoil nucleus. By leveraging an improved understanding of particle identification and background parameterization, we aim to achieve a new level of sensitivity to coherent interactions at low neutrino energy. The outcome of this analysis will contribute to ongoing efforts to model neutrino nucleus interactions accurately in neutrino oscillation studies and beyond Standard Model searches in MicroBooNE and future experiments, such as DUNE. We present progress towards a measurement of charged current coherent pion production cross-section on argon with the MicroBooNE liquid argon time projection chamber detector. This measurement will use MicroBooNE's full dataset collected from the Booster Neutrino Beam with a total exposure of \( 1.3 \times 10^{21} \) protons-on-target and average neutrino energy of 0.8 GeV.

Hussain, Adil [Kansas State U.]↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Probing BSM Oscillatory Signals with the DUNE Detectors and the LBNF Neutrino Beam: NSI and Sterile Neutrino Sensitivities

The Deep Underground Neutrino Experiment (DUNE) is a flagship long-baseline accelerator neutrino experiment under construction in the U.S. With a 1,300 km distance between its Near Detector (ND) and Far Detector (FD), the world’s most intense LBNF (Long-Baseline Neutrino Facility) neutrino beam, and high-resolution LArTPC (Liquid Argon Time Projection Chamber) detectors, DUNE will measure the neutrino oscillation parameters with unprecedented precision. In addition to the determination of the neutrino mass ordering and the potential discovery of Charge-Parity violation in the leptonic sector, DUNE's capabilities present a unique opportunity for probing Beyond the Standard Model (BSM) physics signals with neutrinos. Examples of BSM physics manifestations include the presence of Non-Standard Interactions (NSI) of neutrinos with matter, or the existence of sterile neutrinos that mix with 3-Flavor neutrinos. In this study, we present a joint ND+FD fit to simulated data assessing DUNE's sensitivity to probing neutrino NSI, as well as scenarios including sterile neutrino mixing.

Prais, Luiz [Cincinnati U.] (ORCID:000000018224947↗

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mass reconstruction of heavy neutral leptons from stopped mesons

Heavy neutral leptons (HNLs), depending on their mass and mixing, can be efficiently produced in meson decays from the target or absorber in short- to medium-baseline accelerator neutrino experiments, leaving detectable signals through their decays inside the neutrino detectors. We show that the currently running ICARUS experiment at Fermilab can reconstruct the HNL mass and explore new HNL parameter space in the mass range of 70–190 MeV. The mass reconstruction is enabled by two ingredients: (i) simple two-body kinematics of HNL production from stopped kaon decays at the NuMI absorber, followed by HNL decay into a charged-lepton pair and neutrino at the detector, and (ii) high resolution of Liquid Argon Time Projection Chamber (LArTPC) detectors in reconstructing final state particles. Our mass reconstruction method is robust under realistic energy resolution and angular smearing of the charged leptons, and is applicable to any LArTPC detector. We also discuss the synergy between ICARUS and future facilities like DUNE near detector and PIP-II beam dump in probing the HNL parameter space. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗