Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Formulation of Three-Phase State Estimation Problem Using a Virtual Reference

State Estimation (SE) is the backbone of modern Energy Management System (EMS) due its capability of processing real time measurements and provide reliable information to system operators. Since its introduction to power systems in the 70’s, SE has been widely used in transmission networks. Distribution grids on the other hand lack sufficient number of real time measurements, and for that reason SE has not been widely implemented on these systems. The recent increase in the number of renewable energy sources connected to the grid at lower voltage levels, the advent of Distribution Automation (DA) and Smart Grids necessitate closer monitoring of distribution networks and thus forcing utilities to upgrade their operations and deploy Advanced Distribution Management Sytems (ADMS). Therefore, Distribution System State Estimation (DSE) is paramount to provide real time monitoring of active distribution grids. This papers investigates the formulation of the three-phase distribution state estimation where in the most general case, none of the system buses may have balanced three phase voltages. In such a case, the choice and definition of the slack bus need to be revisited. Most of the existing work arbitrarily assign the root bus of the distribution feeder as the balanced three-phase reference which may not be realistic for today’s active distribution systems. This paper addresses this shortcoming of the existing SE formulations by introducing a virtual reference bus. Here, the proposed approach is effectively validated by simulations carried out on distribution test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Attosecond Time-Domain Measurement of Core-Level-Exciton Decay in Magnesium Oxide

Excitation of ionic solids with extreme ultraviolet pulses creates localized core-level excitons, which in some cases couple strongly to the lattice. In this paper, core-level-exciton states of magnesium oxide are studied in the time domain at the Mg L 2 , 3 edge with attosecond transient reflectivity spectroscopy. Attosecond pulses trigger the excitation of these short-lived quasiparticles, whose decay is perturbed by time-delayed near-infrared pulses. Combined with a few-state theoretical model, this reveals that the infrared pulse shifts the energy of bright (dipole-allowed) core-level-exciton states as well as induces features arising from dark core-level excitons. We report coherence lifetimes for the two lowest core-level excitons of 2.3 ± 0.2 and 1.6 ± 0.5 fs and show that these are primarily a consequence of strong exciton-phonon coupling, disclosing the drastic influence of structural effects in this ultrafast relaxation process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Depth-Penetrating Measurements Developed for Thermal Barrier Coatings Incorporating Thermographic Phosphors

The insulating properties of thermal barrier coatings (TBCs) provide highly beneficial thermal protection to turbine engine components by reducing the temperature sustained by those components. Therefore, measuring the temperature beneath the TBC is critical for determining whether the TBC is performing its insulating function. Currently, noncontact temperature measurements are performed by infrared pyrometry, which unfortunately measures the TBC surface temperature rather than the temperature of the underlying component. To remedy this problem, the NASA Glenn Research Center, under the Information Rich Test Instrumentation Project, developed a technique to measure the temperature beneath the TBC by incorporating a thin phosphor layer beneath the TBC. By performing fluorescence decay-time measurements on light emission from this phosphor layer, Glenn successfully measured temperatures from the phosphor layer up to 1100 C. This is the first successful demonstration of temperature measurements that penetrate beneath the TBC. Thermographic phosphors have a history of providing noncontact surface temperature measurements. Conventionally, a thermographic phosphor is applied to the material surface and temperature measurements are performed by exciting the phosphor with ultraviolet light and then measuring the temperature-dependent decay time of the phosphor emission at a longer wavelength. The innovative feature of the new approach is to take advantage of the relative transparency of the TBC (composed of yttria-stabilized zirconia) in order to excite and measure the phosphor emission beneath the TBC. The primary obstacle to achieving depth-penetrating temperature measurements is that the TBCs are completely opaque to the ultraviolet light usually employed to excite the phosphor. The strategy that Glenn pursued was to select a thermographic phosphor that could be excited and emit at wavelengths that could be transmitted through the TBC. The phosphor that was selected was yttria doped with europia (Y2O3:Eu), which has a minor excitation peak at 532 nm (green) and an emission peak at 611 nm (red)--both are wavelengths that exhibit significant transmission through the TBC. The measurements were performed on specimens consisting of a 25- m-thick phosphor layer beneath a 100- m-thick TBC. The 532-nm (green) excitation light was provided by a frequency-doubled YAG:Nd (yttrium-aluminum-garnet:neodymium) laser, and the fluorescence decay time measurements were acquired with a modified Raman microscope. The preceding graph compares the intensity of the phosphor emission of the phosphor layer above the TBC versus that of the phosphor layer beneath the TBC. Although there was considerable attenuation of the phosphor signal (a factor of 30), the phosphor emission at the reduced intensity was more than sufficient to perform fluorescence decay time measurements. The following graph shows the fluorescence lifetime temperature dependency for the Y2O3:Eu phosphor layers both above and below the TBC. These curves show an excellent match and indicate that, despite the attenuation due to the overlying TBC, the phosphor layer beneath the TBC still functions as an effective temperature indicator.

Eldridge, Jeffrey I.↗

Element- and Time-Resolved Measurements of Spin Dynamics Using X-ray Detected Ferromagnetic Resonance

Although XFMR experiments have been carried out at a number of synchrotron radiation facilities since 2004, only a few facilities currently have XFMR setups available for user operation. Here in this review, we mainly focus on recent developments and work that has been carried out using time-resolved XFMR at beamline 4.0.2 of the Advanced Light Source and at beamline I10 of the Diamond Light Source. The experimental setup and the sample holder used at beamline I10 and beamline 4.0.2, respectively, are shown in Figure 1. We will first introduce the working principle of XFMR and then provide examples of the capabilities of this technique. Finally, we will briefly describe an outlook for the future development of and new opportunities for XFMR.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CACTUS: A depleted monolithic active timing sensor using a CMOS radiation hard technology

The planned luminosity increase at the Large Hadron Collider in the coming years has triggered interest in the use of the particles' time of arrival as additional information in specialized detectors to mitigate the impact of pile-up. The required time resolution is of the order of tens of picoseconds, with a spatial granularity of the order of 1 mm. A time measurement at this precision level will also be of interest beyond the LHC and beyond high energy particle physics. We present in this paper the first developments towards a radiation hard Depleted Monolithic Active Pixel Sensor (DMAPS), with high-resolution time measurement capability. The technology chosen is a standard high voltage CMOS process, in conjunction with a high resistivity detector material, which has already proven to efficiently detect particles in tracking applications after several hundred of Mrad of irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Super-resolved time–frequency measurements of coupled phonon dynamics in a 2D quantum material

Abstract Methods to probe and understand the dynamic response of materials following impulsive excitation are important for many fields, from materials and energy sciences to chemical and neuroscience. To design more efficient nano, energy, and quantum devices, new methods are needed to uncover the dominant excitations and reaction pathways. In this work, we implement a newly-developed superlet transform—a super-resolution time-frequency analytical method—to analyze and extract phonon dynamics in a laser-excited two-dimensional (2D) quantum material. This quasi-2D system, 1 T -TaSe 2 , supports both equilibrium and metastable light-induced charge density wave (CDW) phases mediated by strongly coupled phonons. We compare the effectiveness of the superlet transform to standard time-frequency techniques. We find that the superlet transform is superior in both time and frequency resolution, and use it to observe and validate novel physics. In particular, we show fluence-dependent changes in the coupled dynamics of three phonon modes that are similar in frequency, including the CDW amplitude mode, that clearly demonstrate a change in the dominant charge-phonon couplings. More interestingly, the frequencies of the three phonon modes, including the strongly-coupled CDW amplitude mode, remain time- and fluence-independent, which is unusual compared to previously investigated materials. Our study opens a new avenue for capturing the coherent evolution and couplings of strongly-coupled materials and quantum systems.

36 MATERIALS SCIENCE↗

Robust Medium-Voltage Distribution System State Estimation using Multi-Source Data

Due to the lack of sufficient online measurements for distribution system observability, pseudo-measurements from short-term load or distributed renewable energy resources (DERs) forecasting are used. However, the accuracy of them is low and thus significantly limits the performance of distribution system state estimation (DSSE). In this paper, a robust DSSE that integrates multi-source measurement data is proposed. Specifically, the historical low-voltage (LV) side smart meters are used to forecast load and DERs injections via the support vector machine (SVM) with optimally tuned parameters. By contrast, the online smart meters at LV side are utilized to derive equivalent power injections at the MV/LV transformers, yielding more accurate pseudo-measurements compared to the forecasted injections. Furthermore, to deal with bad data caused by communication loss, instrumental errors and cyber attacks, robust DSSE that relies on generalized maximum-likelihood (GM)-estimation criterion is developed. The projection statistics are developed to adjust the weights of each measurement, leading to better balance between pseudo- and real-time measurements. Numerical results conducted on modified IEEE 33-bus system with DG integration demonstrate the effectiveness and robustness of the proposed method.

distribution system state estimation↗

Hydromagnetic wavelike phenomena from Helios time delay measurements by remote sensing

A survey of the electron content measurements during solar occultations of the Helios A and B spacecraft is presented, and a spectral analysis using the method of maximum entropy is discussed. Typical variations measured are on the order of 0.1-1.8 x 10 to the 18th/sq m, while typical values for the rate of change are 0.7-50 x 10 to the 13th per sq m per sec. Numerical results in agreement with findings from Helios radio science, reveal a fundamental period of about 70 minutes superimposed by minor spectral peaks corresponding to shorter time periods such as 35 and 25 minutes. In addition, the periodicities observed in electron content are discussed in terms of fast hydromagnetic waves excited by nonlinear Alfven waves via coupling terms before crossing the Helios ray path. It is noted that for the first time experimental evidence is presented that hydromagnetic waves may actually be propagating from the solar corona into the interplanetary medium.

Edenhofer, P.↗

Time-resolved measurements of nonthermal X-ray emission of Ti XXI lines in electron-cyclotron-heated tokamak plasmas

The observation of heliumlike titanium spectra with 20 ms temporal resolution during high-power injection of electron cyclotron heating (ECH) of up to 250 ms pulse length into the Doublet III tokamak is reported. The prominent lines in the spectra and the observed dielectronic satellite lines from the autoionizing lithiumlike ionization states are given. The intensity of the resonance line 1s2 1S0 - 1s 2p 1P1 is found to be extremely sensitive to the ECH power. Time-resolved line ratios are also presented. It is concluded that a significant departure from a Maxwellian distribution of electrons exists in the present ECH plasmas.

Lee, P.↗

Zonal-Mean Temperature Variations Inferred from SABER Measurements on TIMED Compared with UARS Observations

In the Numerical Spectral Model (NSM, Mayr et al., 2003), small-scale gravity waves propagating in the north/south direction can generate zonal mean (m = 0) meridional wind oscillations with periods between 2 and 4 months. These oscillations tend to be confined to low latitudes and have been interpreted to be the meridional counterpart of the wave-driven Quasi Biennial Oscillation in the zonal circulation. Wave driven meridional winds across the equator should generate, due to dynamical heating and cooling, temperature oscillations with opposite phase in the two hemispheres. We have analyzed SABER temperature measurements in the altitude range between 55 and 95 km to investigate the existence such variations. Because there are also strong tidal signatures (up to approximately 20 K) in the data, our algorithm estimates both mean values and tides together from the data. Based on SABER temperature data, the intra-annual variations with periods between 2 and 4 months can have amplitudes up to 5 K or more, depending on the altitude. Their amplitudes are in qualitative agreement with those inferred Erom UARS data (from different years). The SABER temperature variations also reveal pronounced hemispherical asymmetries, which are qualitatively consistent with wave driven meridional wind oscillations across the equator. Oscillations with similar periods have been seen in the meridional winds based on UARS data (Huang and Reber, 2003).

Huang, Frank T.↗

Nanoscale solid-state nuclear quadrupole resonance spectroscopy using depth-optimized nitrogen-vacancy ensembles in diamond

Nuclear magnetic resonance (NMR) and nuclear quadrupole resonance (NQR) spectroscopy of bulk quantum materials have provided insight into phenomena, such as quantum phase criticality, magnetism, and superconductivity. With the emergence of nanoscale 2D materials with magnetic phenomena, inductively detected NMR and NQR spectroscopy are not sensitive enough to detect the smaller number of spins in nanomaterials. The nitrogen-vacancy (NV) center in diamond has shown promise in bringing the analytic power of NMR and NQR spectroscopy to the nanoscale. However, due to depth-dependent formation efficiency of the defect centers, noise from surface spins, band bending effects, and the depth dependence of the nuclear magnetic field, there is ambiguity regarding the ideal NV depth for surface NMR of statistically polarized spins. In this work, we prepared a range of shallow NV ensemble layer depths and determined the ideal NV depth by performing NMR spectroscopy on statistically polarized 19 F in Fomblin oil on the diamond surface. We found that the measurement time needed to achieve a signal-to-noise ratio of 3 using XY8-N noise spectroscopy has a minimum at an NV ensemble depth of 5.5 ± 1.5 nm for ensembles activated from 100 ppm nitrogen concentration. To demonstrate the sensing capabilities of NV ensembles, we perform NQR spectroscopy on the 11 B of hexagonal boron nitride flakes. We compare our best diamond to previous work with a single NV and find that this ensemble provides a shorter measurement time with excitation diameters as small as 4 μm. Furthermore, this analysis provides ideal conditions for further experiments involving NMR/NQR spectroscopy of 2D materials with magnetic properties.

2D materials↗

Testing of a Microwave Blade Tip Clearance Sensor at the NASA Glenn Research Center

The development of new active tip clearance control and structural health monitoring schemes in turbine engines and other types of rotating machinery requires sensors that are highly accurate and can operate in a high temperature environment. The use of a microwave sensor to acquire blade tip clearance and tip timing measurements is being explored at the NASA Glenn Research Center. The microwave blade tip clearance sensor works on principles that are very similar to a short range radar system. The sensor sends a continuous microwave signal towards a target and measures the reflected signal. The phase difference of the reflected signal is directly proportional to the distance between the sensor and the target being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in turbine engines. The use of microwave sensors for this application is a new concept. Techniques on calibrating the sensors along with installation effects are not well quantified as they are for other sensor technologies. Developing calibration techniques and evaluating installation effects are essential in using these sensors to make tip clearance and tip timing measurements. As a means of better understanding these issues, the microwave sensors were used on a bench top calibration rig, a large axial vane fan, and a turbofan. Background on the microwave tip clearance sensor, an overview of their calibration, and the results from their use on the axial vane fan and the turbofan will be presented in this paper.

Woike, Mark R.↗

Testing of a Microwave Blade Tip Clearance Sensor at the NASA Glenn Research Center

The development of new active tip clearance control and structural health monitoring schemes in turbine engines and other types of rotating machinery requires sensors that are highly accurate and can operate in a high-temperature environment. The use of a microwave sensor to acquire blade tip clearance and tip timing measurements is being explored at the NASA Glenn Research Center. The microwave blade tip clearance sensor works on principles that are very similar to a short-range radar system. The sensor sends a continuous microwave signal towards a target and measures the reflected signal. The phase difference of the reflected signal is directly proportional to the distance between the sensor and the target being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in turbine engines. The use of microwave sensors for this application is a new concept. Techniques on calibrating the sensors along with installation effects are not well quantified as they are for other sensor technologies. Developing calibration techniques and evaluating installation effects are essential in using these sensors to make tip clearance and tip timing measurements. As a means of better understanding these issues, the microwave sensors were used on a benchtop calibration rig, a large axial vane fan, and a turbofan. Background on the microwave tip clearance sensor, an overview of their calibration, and the results from their use on the axial vane fan and the turbofan will be presented in this paper.

Woike, Mark R.↗

Holocinematographic velocimeter for measuring time-dependent, three-dimensional flows

Two simulatneous, orthogonal-axis holographic movies are made of tracer particles in a low-speed water tunnel to determine the time-dependent, three-dimensional velocity field. This instrument is called a Holocinematographic Velocimeter (HCV). The holographic movies are reduced to the velocity field with an automatic data reduction system. This permits the reduction of large numbers of holograms (time steps) in a reasonable amount of time. The current version of the HCV, built for proof-of-concept tests, uses low-frame rate holographic cameras and a prototype of a new type of water tunnel. This water tunnel is a unique low-disturbance facility which has minimal wall effects on the flow. This paper presents the first flow field examined by the HCV, the two-dimensional von Karman vortex street downstream of an unswept circular cylinder. Key factors in the HCV are flow speed, spatial and temporal resolution required, measurement volume, film transport speed, and laser pulse length. The interactions between these factors are discussed.

Beeler, George B.↗

Real-time sensor measurements to evaluate impacts of load cycling on high-temperature fire-side corrosion in a PC boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

2024 Milestone Report: Site 300 mPDV Optical Fiducials

In the early 2000s Photon Doppler Velocimetry (PDV) replaced the Fabry-Perot many beam system1 and has since become ubiquitous across dynamic experimental platforms to measure velocity and event times such as shock breakout, key variables for high pressure physics research. The advent of optically multiplexed oscilloscope channels to create multiplexed PDV (mPDV) increased portability and reduced price per data point. However, these advantages came with the cost of additional fielding complexity and thermally induced timing drift, which directly affects the ability to use PDV for high precision time measurement. Controlling the temperature or incorporating optical fiducials allows researchers to characterize, reduce, and correct this thermal drift in analysis. Our implemented optical fiducial or “timing marker” allows us to reduce thermal drift uncertainty from the 10s of nanoseconds down to the 100s of picoseconds with minimal added complexity to existing systems. The implementation of this timing marker normalizes uncertainty across optical delays, brings our facility cross timing into the sub nanosecond regime and lets us identify/study anomalies in our data. This improvement increases experiment reliability and quality enabling a new class of high precision experiments at S300.

42 ENGINEERING↗