Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A Novel Multiple-Time Scale Integrator for the Hybrid Monte Carlo Algorithm

Hybrid Monte Carlo simulations that implement the fermion action using multiple terms are commonly used. By the nature of their formulation they involve multiple integration time scales in the evolution of the system through simulation time. These different scales are usually dealt with by the Sexton-Weingarten nested leapfrog integrator. In this scheme the choice of time scales is somewhat restricted as each time step must be an exact multiple of the next smallest scale in the sequence. A novel generalisation of the nested leapfrog integrator is introduced which allows for far greater flexibility in the choice of time scales, as each scale now must only be an exact multiple of the smallest step size.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and characterization of the time-resolved opacity spectrometer (OpSpecTR) for the NIF iron opacity campaign

A new time-resolved opacity spectrometer (OpSpecTR) is currently under development for the National Ignition Facility (NIF) opacity campaign. Here, the spectrometer utilizes Icarus version 2 (IV2) hybridized complementary metal–oxide–semiconductor sensors to collect gated data at the time of the opacity transmission signal, unlocking the ability to collect higher-temperature measurements on NIF. Experimental conditions to achieve higher temperatures are feasible; however, backgrounds will dominate the data collected by the current time-integrating opacity spectrometer. The shortest available OpSpecTR integration time of ~2 ns is predicted to reduce self-emission and other late-time backgrounds by up to 80%. Initially, three Icarus sensors will be used to collect data in the self-emission, backlighter, and absorption regions of the transmission spectrum, with plans to upgrade to five Daedalus sensors in future implementations with integration times of ~1.3 ns. We present the details of the diagnostic design along with recent characterization results of the IV2 sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of the target diagnostic control system in the National Ignition Facility

The extreme physics of targets shocked by NIF's 192-beam laser are observed by a diverse suite of diagnostics including optical backscatter, time-integrated, time resolved and gated X-ray sensors, laser velocity interferometry, and neutron time of flight. Diagnostics to diagnose fusion ignition implosion and neutron emissions have been developed. A Diagnostic Control System (DCS) for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost Window XP processor and Java application. Instruments are aggregated as needed in the supervisory system to form an integrated diagnostic. The Java framework provides data management, control services and operator GUI generation. During the past several years, over thirty-six diagnostics have been deployed using this architecture in support of the National Ignition Campaign (NIC). The DCS architecture facilitates the expected additions and upgrades to diagnostics as more experiments are performed. This paper presents the DCS architecture, framework and our experiences in using it during the NIC to operate, upgrade and maintain a large set of diagnostic instruments.

42 ENGINEERING↗

Analysis of a Real-Time Separation Assurance System with Integrated Time-in-Trail Spacing

This paper describes the implementation and analysis of an integrated ground-based separation assurance and time-based metering prototype system into the Center-TRACON Automation System. The integration of this new capability accommodates constraints in four-dimensions: position (x-y), altitude, and meter-fix crossing time. Experiments were conducted to evaluate the performance of the integrated system and its ability to handle traffic levels up to twice that of today. Results suggest that the integrated system reduces the number and magnitude of time-in-trail spacing violations. This benefit was achieved without adversely affecting the resolution success rate of the system. Also, the data suggest that the integrated system is relatively insensitive to an increase in traffic of twice the current levels.

Aweiss, Arwa S.↗

PPINN: Parareal physics-informed neural network for time-dependent PDEs

Physics-informed neural networks (PINNs) encode physical conservation laws and prior physical knowledge into the neural networks, ensuring the correct physics is represented accurately while alleviating the need for supervised learning to a great degree. While effective for relatively short-term time integration, when long time integration of the time-dependent PDEs is sought, the time–space domain may become arbitrarily large and hence training of the neural network may become prohibitively expensive. To this end, we develop a parareal physics-informed neural network (PPINN), hence decomposing a long-time problem into many independent short-time problems supervised by an inexpensive/fast coarse-grained (CG) solver. In particular, the serial CG solver is designed to provide approximate predictions of the solution at discrete times, while initiate many fine PINNs simultaneously to correct the solution iteratively. There is a two-fold benefit from training PINNs with small-data sets rather than working on a large-data set directly, i.e., training of individual PINNs with small-data is much faster, while training the fine PINNs can be readily parallelized. Consequently, compared to the original PINN approach, the proposed PPINN approach may achieve a significant speed-up for long-time integration of PDEs, assuming that the CG solver is fast and can provide reasonable predictions of the solution, hence aiding the PPINN solution to converge in just a few iterations. To investigate the PPINN performance on solving time-dependent PDEs, we first apply the PPINN to solve the Burgers equation, and subsequently we apply the PPINN to solve a two-dimensional nonlinear diffusion–reaction equation. Furthermore, our results demonstrate that PPINNs converge in a few iterations with significant speed-ups proportional to the number of time-subdomains employed.

42 ENGINEERING↗

Dynamic implicit 3D adaptive mesh refinement for non-equilibrium radiation diffusion

The time dependent non-equilibrium radiation diffusion equations are important for solving the transport of energy through radiation in optically thick regimes and find applications in several fields including astrophysics and inertial confinement fusion. The associated initial boundary value problems that are encountered often exhibit a wide range of scales in space and time and are extremely challenging to solve. To efficiently and accurately simulate these systems we describe our research on combining techniques that will also find use more broadly for long term time integration of nonlinear multi-physics systems: implicit time integration for efficient long term time integration of stiff multi-physics systems, local control theory based step size control to minimize the required global number of time steps while controlling accuracy, dynamic 3D adaptive mesh refinement (AMR) to minimize memory and computational costs, Jacobian Free Newton–Krylov methods on AMR grids for efficient nonlinear solution, and optimal multilevel preconditioner components that provide level independent solver convergence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Progressive TDI Measurements with the PACE OCI ETU

The Plankton Aerosol Cloud ocean Ecosystem (PACE) Ocean Color Instrument (OCI) has completed the ground test program for its engineering unit (ETU) and testing of the flight unit will begin in the near future. OCIis a grating spectrometer with hyperspectral coverage from about 340 nm to 885 nm with 9 additional filtered channels in the SWIR. Two CCDs are used as detectors for the hyperspectral channels. One important operating mode of the CCDs on OCI is progressive time delay integration (or PTDI). In this mode, the charge in the CCD can be held for multiples of the nominal integration times. A series of these measurements can be made with progressively increasing multiples of the nominal integration time as the instrument scans across a uniform source. Ground testing with this operating mode on OCI ETU has shown promising results. This work will present measurements taken with the PTDI mode and the analysis of OCI ETU linearity and dynamic range

PACE↗

An inexpensive technique for the time resolved laser induced plasma spectroscopy

We present an efficient and inexpensive method for calculating the time resolved emission spectrum from the time integrated spectrum by monitoring the time evolution of neutral and singly ionized species in the laser produced plasma. To validate our assertion of extracting time resolved information from the time integrated spectrum, the time evolution data of the Cu II line at 481.29 nm and the molecular bands of AlO in the wavelength region (450–550 nm) have been studied. The plasma parameters were also estimated from the time resolved and time integrated spectra. A comparison of the results clearly reveals that the time resolved information about the plasma parameters can be extracted from the spectra registered with a time integrated spectrograph. Our proposed method will make the laser induced plasma spectroscopy robust and a low cost technique which is attractive for industry and environmental monitoring.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of the moderators in the STS preliminary design

This report details the results for an optimization of the dimensions of the moderators in the preliminary design of the Spallation Neutron Source Second Target Station (STS). This study uses the optimization algorithms of Dakota and an unstructured mesh model for the moderators in MCNP. More details on the unstructured mesh model and the automated mesh generation can be found in [3]. Parallel to this effort, the same moderator geometries have been optimized using a constructive solid geometry (CSG) MCNP model. More details on this model and its results can be found in [4]. Three optimal designs are selected for each moderator: one that is optimized for maximum peak brightness, one for maximum time-integrated brightness, and one for a combination of peak and time-integrated brightness. The backbone of the optimization work flow is provided by Dakota. For each set of design parameters requested by Dakota, a new solid geometry is automatically built in Creo and SpaceClaim, and subsequently exported to Attila4MC to generate an unstructured mesh geometry for MCNP. After the MCNP calculation is finished, the objective function (e.g., brightness metric) is returned to Dakota. After the new design has been evaluated, a result-file is written, and Dakota proposes the next set of design parameters to be evaluated. The loop continues until a specified convergence criterion has been met. The design parameters of the cylindrical (upper) moderator include the hydrogen radius, the premoderator thickness (top, bottom, radial), the beryllium radius and the horizontal position of the moderator. The crucial design choice is the hydrogen radius. A radius of 62 mm is shown to provide the maximum time-integrated brightness. The maximum peak brightness occurs with a radius of 40 mm. A combined (middle) design, which balances peak and time-integrated brightnesses, is obtained with a hydrogen radius of 50 mm. The premoderator thicknesses and the beryllium radius are slightly larger in the design optimized for time-integrated brightness than in the design optimized for peak brightness. The sensitivity to these two parameters is relatively small close to the optimal configurations. The hydrogen vessel and vacuum vessel wall thicknesses are dependent on the radius of the liquid hydrogen due to structural integrity requirements. The increased wall thicknesses for larger vessels significantly penalize the time-integrated brightness, with the maximum obtainable value reduced by more than 10% relative to earlier studies which used fixed vessel wall thicknesses. The impact of the variable wall thicknesses is much less for the peak brightness and combined brightness designs. The design parameters of the tube (lower) moderator selected for the optimization are the tube length, the annular premoderator thickness, the beryllium radius and the horizontal position of the moderator. The tube length is the crucial parameter and is chosen large (210 mm) and small (125 mm) in the designs optimized for time-integrated and peak brightness respectively. A combined optimal design has a tube length of 170 mm. The premoderator thickness and the beryllium radius are chosen larger in the design optimized for time-integrated brightness.

42 ENGINEERING↗

A comparative assessment of R. M. Young and tipping bucket rain gauges

Rain rates as derived from standard tipping bucket rain gauges have variable integration times corresponding to the interval between bucket tips. For example, the integration time for the Weathertronics rain gauge is given by delta(T) = 15.24/R (min), where R is the rain rate expressed in mm/h and delta(T) is the time between tips expressed in minutes. It is apparent that a rain rate of 1 mm/h has an integration time in excess of 15 minutes. Rain rates larger than 15.24 mm/h will have integration times smaller than 1 minute. The integration time is dictated by the time it takes to fill a small tipping bucket where each tip gives rise to 0.254 mm of rainfall. Hence, a uniform rain rate of 1 mm/h over a 15 minute period will give rise to the same rain rate as 0 mm/h rainfall over the first 14 minutes and 15 mm/h between 14 to 15 minutes from the reference tip. Hence, the rain intensity fluctuations may not be captured with the tipping bucket rain gauge for highly variable rates encompassing lower and higher values over a given integration time. The objective of this effort is to provide an assessment of the features of the R. M. Young capacitive gauge and to compare these features with those of the standard tipping bucket rain gauge. A number of rain rate-time series derived from measurements with approximately co-located gauges are examined.

Goldhirsh, Julius↗

National Ignition Facility Opacity Time Resolved Spectrometer Systems Engineering Final Project

The National Ignition Facility (NIF) is the world’s largest and most energetic laser facility. The NIF system is designed to produce high energy density (temperature and pressure) conditions through the application of its 192 laser beams. One of the users of NIF is the opacity platform developed to study the opacities at temperatures and densities relevant to the solar interior and stellar evolution. The platform was developed to study iron (Fe) opacity at temperatures relevant to the solar interior. The opacity campaign uses spectrometers to gather data. Spectrometers utilize crystals to produce x-ray spectra that are recorded on time-integrated and time-resolved detectors. The opacity spectrometer (OpSpec) currently fielded and in use at NIF uses a time integrated film channel to collect data. The opacity spectrometer time resolved (OpSpecTR) will utilize novel hCMOS detectors to capture time resolved images of spectra of interest. The key stakeholders identified for OpSpecTR included the physicists responsible for OpSpec and OpSpecTR, the Target Area Science and Engineering (TASE) department at NIF, the NIF and Photon Science (NIF & PS) Opacity program, the Nevada National Security Site (NNSS) Physics and Engineering program, the Sandia hCMOS manufacturing and testing program, and the Los Alamos National Laboratory (LANL) program sponsor. The Target and Experimental Operations (TEXOPS) was identified as a key stakeholder because the group includes the individuals that will physically interact with the OpSpecTR system as it participates in NIF experiments. The opacity platform collects data in a unique orientation relative to the existing diagnostics fielded at NIF. The existing infrastructure at NIF uses a diagnostic manipulator (DIM) to insert the diagnostic near the target chamber center to collect data during a NIF shot. Existing diagnostics collect data through the center line of the DIM axis and collect relevant data perpendicular to this axis. The opacity platform requires crystals mounted in a specific orientation which requires data collection parallel to the DIM axis. This deviation from standard NIF practices was a key factor in developing requirements.

42 ENGINEERING↗

Multigrid methods with space–time concurrency

Here, we consider the comparison of multigrid methods for parabolic partial differential equations that allow space–time concurrency. With current trends in computer architectures leading towards systems with more, but not faster, processors, space–time concurrency is crucial for speeding up time-integration simulations. In contrast, traditional time-integration techniques impose serious limitations on parallel performance due to the sequential nature of the time-stepping approach, allowing spatial concurrency only. This paper considers the three basic options of multigrid algorithms on space–time grids that allow parallelism in space and time: coarsening in space and time, semicoarsening in the spatial dimensions, and semicoarsening in the temporal dimension. We develop parallel software and performance models to study the three methods at scales of up to 16K cores and introduce an extension of one of them for handling multistep time integration. We then discuss advantages and disadvantages of the different approaches and their benefit compared to traditional space-parallel algorithms with sequential time stepping on modern architectures.

97 MATHEMATICS AND COMPUTING↗

Radiative Properties of Implosions of Stainless Steel Wire Arrays with Application to Astrophysics

Experiments with different stainless steel (SS) wire loads were performed on the 1 MA Zebra Z-pinch generator at University of Nevada, Reno. The wire array loads consisted of 7.6 {mu}m SS wires and had 10 wires for the planar wire array with an interwire gap of 1 mm and 8 wires for the cylindrical wire array of a 16 mm diameter. In addition, a single-wire experiment with a 25 {mu}m SS wire was carried out. The different wire loads were used to provide a broader spectrum of plasma conditions. Time-integrated and time-gated x-ray images, as well as time-integrated, spatially-resolved and spatially-integrated x-ray spectra, were collected and analyzed. Both K-shell and L-shell radiation were recorded using LiF and KAP crystal spectrometers, respectively. Non-LTE kinetic models of Fe and Ni are employed to derive plasma parameters. For axially resolved L-shell spectra, the resulting electron temperatures are between 230 and 300 eV (higher near the cathode) and electron densities vary from 10{sup 19} to 10{sup 20} cm{sup -3} dependent on the load. The advantage of using Z-pinch plasmas for astrophysical applications is highlighted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parallel multi-time step integration on a transputer system

An algorithm which allows different nodes of the finite element mesh to be integrated with different time steps is presented for second order finite element systems. The implementation of this algorithm on a system of transputer processors is discussed and a numerical example is used to evaluate the efficiency of the algorithm.

Smolinski, P.↗

Extreme and far ultraviolet astronomy from Voyagers 1 and 2

The instrumental characteristics, observational capabilities and scientific results of the Voyager 1 and 2 ultraviolet spectrometers are reviewed. These instruments provide current and ongoing access to low resolution spectra for a wide variety of astronomical sources in the 500 to 1700 A band. Observations of the brightest OB stars and hot subluminous stars as faint as V = 15 mag, are possible. In the EUV, at wavelengths shortward of 900 A, several new sources have been detected and a host of potential sources ruled out. In the far UV, particularly at wavelengths between 900 and 1200 A, Voyager is capable of observing a wide range of stellar and non-stellar sources. Such observations can often provide a valuable complement to IUE and other data sets at longer wavelengths. The Voyager spectrometers have proved remarkably stable photon counting instruments, capable of extremely long integration times. The long integration times, relatively large field of view, and location in the outer solar system also provide an ideal platform for observations of sources of faint diffuse emission, such as nebulae and the general sky background.

Holberg, J. B.↗

Comparative Analysis of Radiometer Systems Using Non-Stationary Processes

Radiometers require periodic calibration to correct for instabilities in the receiver response. Various calibration techniques exist that minimize the effect of instabilities in the receivers. The optimal technique depends upon many parameters. Some parameters are constrained by the particular application and others can be chosen in the system design. For example, the measurement uncertainty may be reduced to the limits of the resolution of the measurement (sensitivity) if periodic absolute calibration can be performed with sufficient frequency. However if the period between calibrations is long, a reference-differencing technique, i.e. Dicke-type design, can yield better performance. The measurement uncertainty not only depends upon the detection scheme but also on the number of pixels between calibrations, the integration time per pixel, integration time per calibration reference measurement, calibration reference temperature, and the brightness temperature of what is being measured. The best scheme for reducing the measurement uncertainty also depends, in large part, on the stability of the receiver electronics. In this presentation a framework for evaluating calibration schemes for a wide range of system architectures is presented. Two methods for treating receiver non-stationarity are compared with radiometer measurements.

Racette, Paul↗

Advanced acousto-optic signal processors

The basic acousto-optic signal processing architectures (spectrum analyzer, space-integrating, time-integrating, and triple product processor) systems and algorithms such as the chirp-Z transform are reviewed. New acousto-optic data processing systems and applications that utilze these basic architectures and new ones are described. These include a matched spatial filter acousto-optic processor, two new hybrid time and space-integrating systems, a triple product processor, and four new matrix-vector iterative feedback systems.

Casasent, D.↗