Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thin membrane”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Confocal Raman Microscopy as an In Situ Probe of Volume Change in Hydration-Sensitive Polymer Membranes

An approach is described for measuring hydration-induced volume change within ion conductive polymer membranes and thin films by adapting the technique of confocal Raman microscopy. With careful consideration of factors that affect excitation and scattering within the confocal probe volume region, material swelling and deswelling were estimated from the intensities of polymer matrix spectral features. A high numerical aperture oil-immersion objective was used to achieve tight focusing within samples and the efficient collection of Raman scattered light. The approach is demonstrated for a fluorinated cation-exchange ionomer (Nafion) and the hydrocarbon anion-exchange ionomer Sustainion. Samples were monitored while under a nitrogen atmosphere that was cycled between dry and humid (∼50% relative humidity, RH) states. The volume changes estimated from the Raman spectra were in close agreement with those derived from conventional measurements. The reported work advances understanding needed to adapt confocal Raman microscopy for quantitative in situ and operando studies of ionomers within electrochemical devices, such as polymer electrolyte membrane fuel cells and electrolyzers, and lays a foundation for broader applications in the study of hydration-induced polymer swelling and the associated molecular level water and polymer framework structural changes.

Absorption↗

Fabrication of an Absorber-Coupled MKID Detector

Absorber-coupled microwave kinetic inductance detector (MKID) arrays were developed for submillimeter and far-infrared astronomy. These sensors comprise arrays of lambda/2 stepped microwave impedance resonators patterned on a 1.5-mm-thick silicon membrane, which is optimized for optical coupling. The detector elements are supported on a 380-mm-thick micro-machined silicon wafer. The resonators consist of parallel plate aluminum transmission lines coupled to low-impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The transmission lines simultaneously act to absorb optical power and employ an appropriate surface impedance and effective filling fraction. The fabrication techniques demonstrate high-fabrication yield of MKID arrays on large, single-crystal membranes and sub-micron front-to-back alignment of the micro strip circuit. An MKID is a detector that operates upon the principle that a superconducting material s kinetic inductance and surface resistance will change in response to being exposed to radiation with a power density sufficient to break its Cooper pairs. When integrated as part of a resonant circuit, the change in surface impedance will result in a shift in its resonance frequency and a decrease of its quality factor. In this approach, incident power creates quasiparticles inside a superconducting resonator, which is configured to match the impedance of free space in order to absorb the radiation being detected. For this reason MKIDs are attractive for use in large-format focal plane arrays, because they are easily multiplexed in the frequency domain and their fabrication is straightforward. The fabrication process can be summarized in seven steps: (1) Alignment marks are lithographically patterned and etched all the way through a silicon on insulator (SOI) wafer, which consists of a thin silicon membrane bonded to a thick silicon handle wafer. (2) The metal microwave circuitry on the front of the membrane is patterned and etched. (3) The wafer is then temporarily bonded with wafer wax to a Pyrex wafer, with the SOI side abutting the Pyrex. (4) The silicon handle component of the SOI wafer is subsequently etched away so as to expose the membrane backside. (5) The wafer is flipped over, and metal microwave circuitry is patterned and etched on the membrane backside. Furthermore, cuts in the membrane are made so as to define the individual detector array chips. (6) Silicon frames are micromachined and glued to the silicon membrane. (7) The membranes, which are now attached to the frames, are released from the Pyrex wafer via dissolution of the wafer wax in acetone.

Brown, Ari↗

Optical leakage mitigation in ortho-mode transducer detectors for microwave applications

Ortho-mode transducers (OMT) are a commonly used method of coupling opti-cal signals between waveguides and on-chip circuitry and detectors. While the ideal OMT-waveguide coupling requires minimal disturbance to the waveguide, when used for mm-wave applications the waveguide is often slide though and the OMT probes inserted on a thin support membrane. This interface is a potential source of signal leakage and can lead to signal loss and experimental systematics (e.g. in CMB polarization experiments where lost signal can result in temperature to polarization leakage). Here we report on the development of new OMT- waveguide coupling structures with the goal of reducing leakage at the horn-to-detector-wafer interface. The pixel to pixel optical leakage due to the gap be-tween the coupling waveguide and the backshort is reduced by means of a protrusion that passes through the OMT membrane and connects the waveguide sections on each side of the wafer. High frequency electromagnetic simulations indicate that these protrusions can reduce optical leakage in the gap by ~80% percent, with a ~60% filling factor, respect to an ordinary OMT coupling without protrusion, using designs that are compatible with current fabrication processes. We describe the design of the new coupling structure including the impact of varying two key parameters: wafer to optical coupling gap and protrusion fill factor. Prototype devices have been designed that will characterize the performance of the new design using a relative measurement with varying filling factors. We describe the simulation setup and results, and present a chip layout and sample box designed to perform an initial measurement.

Detectors↗

Development of liquid cells for high resolution imaging and chemical analysis in situ with Transmission Electron Microscopy

The development of liquid cells for transmission electron microscopy (TEM) have enabled breakthroughs in the study of nanoscale structural, morphological, or chemical changes during materials growth and applications [1]. The challenges of achieving high resolution imaging and chemical analysis through liquids often arise from the liquid cells being too thick. Making ultra-thin freestanding membranes and controlling the liquid thickness are some of the key attributes to the recent liquid cell developments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous Decomposition and Dewetting of Nanoscale Alloys: A Comparison of Experiment and Theory

In this work, we consider the coupled process of phase separation and dewetting of metal alloys of nanoscale thickness deposited on solid substrates. The experiments involve applying nanosecond laser pulses that melt the Ag40Ni60 alloy films in two setups: either on thin supporting membranes or on bulk substrates. These two setups allow for extracting both temporal and spatial scales on which the considered processes occur. The theoretical model involves a longwave version of the Cahn–Hilliard formulation used to describe spinodal decomposition, coupled with an asymptotically consistent longwave-based description of dewetting that occurs due to destabilizing interactions between the alloy and the substrate, modeled using the disjoining pressure approach. Careful modeling, combined with linear stability analysis and fully nonlinear simulations, leads to results consistent with the experiments. In particular, we find that the two instability mechanisms occur concurrently, with the phase separation occurring faster and on shorter temporal scales. The modeling results show a strong influence of the temperature dependence of relevant material properties, implying that such a dependence is crucial for the understanding of the experimental findings. The agreement between theory and experiment suggests the utility of the proposed theoretical approach in helping to develop further experiments directed toward formation of metallic alloy nanoparticles of desired properties.

36 MATERIALS SCIENCE↗

Compressive Creep of Polymer Electrolyte Membranes: A Case Study for Electrolyzers

For proton-exchange membrane (PEM) water electrolyzers to be commercially feasible, PEMs must perform over long lifetimes in liquid environments under compression while maintaining mechanical stability. A hydrated environment, while inherent for operation and conductivity, undermines PEM stability. Mechanical stability of PEMs is commonly characterized in tension, which is not applicable to electrolyzers, wherein PEMs could undergo high pressures. In this study, a compression creep procedure is developed using a custom-designed setup to monitor creep response of hydrated PEMs. Furthermore, our results show that PEMs exhibit continuous creep response under compression over 24 h, with a dependence on the applied pressure and hydration state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Membrane Strategies for Water Electrolysis

Hydrogen holds great promise as a clean energy resource to help the global carbon-free energy goal. Here, green hydrogen production from renewable energy-powered water electrolysis can decarbonize hard-to-abate industries and transport applications. Ion-exchange membranes are an essential component of membrane-based water electrolysis, enabling high hydrogen production efficiency through a zero-gap configuration. While perfluorosulfonic acids are the standard polymer electrolyte membrane material, research efforts for membrane alternatives have increased over the years to drive down the cost of electrolyzers and improve devices’ durability without sacrificing performance and efficiency. Here we present our perspectives on acidic, alkaline, and bipolar membranes for water electrolyzers and discuss future research directions to develop advanced membranes for green hydrogen production technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure-function studies reveal ComEA contains an oligomerization domain essential for transformation in gram-positive bacteria

An essential step in bacterial transformation is the uptake of DNA into the periplasm, across the thick peptidoglycan cell wall of Gram-positive bacteria, or the outer membrane and thin peptidoglycan layer of Gram-negative bacteria. ComEA, a DNA-binding protein widely conserved in transformable bacteria, is required for this uptake step. Here we determine X-ray crystal structures of ComEA from two Gram-positive species, Bacillus subtilis and Geobacillus stearothermophilus, identifying a domain that is absent in Gram-negative bacteria. X-ray crystallographic, genetic, and analytical ultracentrifugation (AUC) analyses reveal that this domain drives ComEA oligomerization, which we show is required for transformation. We use multi-wavelength AUC (MW-AUC) to characterize the interaction between DNA and the ComEA DNA-binding domain. Finally, we present a model for the interaction of the ComEA DNA-binding domain with DNA, suggesting that ComEA oligomerization may provide a pulling force that drives DNA uptake across the thick cell walls of Gram-positive bacteria.

59 BASIC BIOLOGICAL SCIENCES↗

Spin-on deposition of amorphous zeolitic imidazolate framework films for lithography applications

Amorphous zeolitic imidazolate framework (aZIF) films have been recently introduced as resists for electron beam and extreme ultraviolet lithography. aZIFs are also being considered for separation applications, including thin film membranes. However, the reported methods for aZIF deposition are currently based on highly empirical trial-and-error approaches that hinder control of film composition, thickness and uniformity as well as scale-up and transferability to different coating geometries. This work presents a method for depositing aZIF films with controllable thickness using dilute precursors mixed immediately before encountering the substrate. Importantly, the method is amenable to quantitative analysis by computational fluid dynamics to extract intrinsic deposition rates and limiting reactant transport diffusivities, enabling predictive physics-based modeling of the deposition process. This allows the deposition method to be adapted for spin coating on silicon wafers to prepare high-quality aZIF films with consistently controlled thickness. Using this approach, high-resolution resist performance and wafer-scale use for beyond extreme-ultraviolet lithography of aZIF films is demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In vitro investigation of protein assembly by combined microscopy and infrared spectroscopy at the nanometer scale

The nanoscale structure and dynamics of proteins on surfaces has been extensively studied using various imaging techniques, such as transmission electron microscopy and atomic force microscopy (AFM) in liquid environments. These powerful imaging techniques, however, can potentially damage or perturb delicate biological material and do not provide chemical information, which prevents a fundamental understanding of the dynamic processes underlying their evolution under physiological conditions. Here, we use a platform developed in our laboratory that enables acquisition of infrared (IR) spectroscopy and AFM images of biological material in physiological liquids with nanometer resolution in a cell closed by atomically thin graphene membranes transparent to IR photons. In this work, we studied the self-assembly process of S-layer proteins at the graphene-aqueous solution interface. The graphene acts also as the membrane separating the solution containing the proteins and Ca 2+ ions from the AFM tip, thus eliminating sample damage and contamination effects. The formation of S-layer protein lattices and their structural evolution was monitored by AFM and by recording the amide I and II IR absorption bands, which reveal the noncovalent interaction between proteins and their response to the environment, including ionic strength and solvation. Our measurement platform opens unique opportunities to study biological material and soft materials in general.

59 BASIC BIOLOGICAL SCIENCES↗

Microfluidic cells for the 1–10 2 MPa pressure range

Thin membrane-delimited fluid cells supporting up to 1 at (0.1 MPa) of pressure are well known and commercially available for use in vacuum chambers of electron, photon, or various particle beam microscopies or spectroscopies. Hereby, we report on the development of fluid cells capable of working at 1–10 MPa, extending the analysis domain for investigating chemical, biochemical, or physical processes at pressures of interest in chemical synthesis, underwater biochemistry studies or underground geology. We explored ways to optimize cell membranes to better resist pressure beyond simply increasing the thickness or decreasing the size of the membranes, using finite element analysis and experimental validation via membrane bulging experiments and failure statistics. Fluid cell prototypes were fabricated using ∼75 nm-thick SiN x membranes, engineered to withstand 4.7 MPa (average value), compared to regular (un-engineered) membranes withstanding only 3.4 MPa (average value). The fluid cell prototypes include eight microchannels for feeding/evacuating the fluids and applying pressure into micro-reaction chambers, two electrodes for electrochemical or conduction measurements in the sample, and a possible pressure or temperature sensor, customizable for specific experiments.

hi-pressure↗

Hybrid target design for imprint mitigation in direct-drive inertial confinement fusion

A target design for mitigating the Rayleigh-Taylor instability is proposed for use in high energy density and direct-drive inertial confinement fusion experiments. In this scheme, a thin gold membrane is offset from the main target by several-hundred microns. A strong picket on the drive beams is incident upon this membrane to produce x rays which generate the initial shock through the target. The main drive follows shortly thereafter, passing through the ablated shell and directly driving the main target. The efficacy of this scheme is demonstrated through experiments performed at the OMEGA EP facility, showing a reduction of the Rayleigh-Taylor instability growth which scales exponentially with frequency, suppressing development by at least a factor of 5 for all wavelengths below 100 μm. Furthermore, this results in a delay in the time of target perforation by ~40%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aluminum-Based Superconducting Tunnel Junction Sensors for Nuclear Recoil Spectroscopy

The BeEST experiment is searching for sub-MeV sterile neutrinos by measuring nuclear recoil energies from the decay of 7 Be implanted into superconducting tunnel junction (STJ) sensors. The recoil spectra are affected by interactions between the radioactive implants and the sensor materials. We are therefore developing aluminum-based STJs (Al-STJs) as an alternative to existing tantalum devices (Ta-STJs) to investigate how to separate material effects in the recoil spectrum from potential signatures of physics beyond the Standard Model. Three iterations of Al-STJs were fabricated. The first had electrode thicknesses similar to existing Ta-STJs. They had low responsivity and reduced resolution, but were used successfully to measure 7 Be nuclear recoil spectra. The second iteration had STJs suspended on thin SiN membranes by backside etching. These devices had low leakage current, but also low yield. The final iteration was not backside etched, and the Al-STJs had thinner electrodes and thinner tunnel barriers to increase signal amplitudes. These devices achieved 2.96 eV FWHM energy resolution at 50 eV using a pulsed 355 nm (~3.5 eV) laser. These results establish Al-STJs as viable detectors for systematic material studies in the BeEST experiment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multiport High-pressure Fluid Cell (MHPFC) for Photon and Electron Beams

A multiport high-pressure fluid cell was developed based on an engineered thin film membrane solution with a reinforced frame of boron-doped silicon, optimized to withstand better pressure with an increase of 17.6% in average burst pressure over similar membranes without frame. The novel cells (patent pending) have 8 microfluidic ports, two intra-cavity electrodes and two pressure sensors on a 8 mm x 8 mm Si chip. The prototypes resisted up to 60 bar with 50-nm-thick silicon nitride membranes of size 70 nm x 70 nm. The cells can be used for testing reactions in fluids in medium-high pressure (up to 300 bar) using X-rays (primary application), electron beams, IR or visible light. Improvements in the pressure sensing setup and customization for applications are supposed to follow.

36 MATERIALS SCIENCE↗

Static and dynamic load measurements in aerospace decelerator canopy fabrics with metal foil strain gages.

A test program was conducted to determine the feasibility of using conventional metal foil strain gages to measure load-time relationships on thin fabric membranes while these membranes were loaded under simulated aerodynamic decelerator conditions. Uniaxial and biaxial tests were made at fabric strain levels up to about 10%. Loadings were made both statically and dynamically, with the fastest load time being 0.015 second for zero to full load on uniaxial test specimens. For the biaxial tests, plane strain conditions were assumed, and by using experimentally determined strain-load relationships, principal loads were determined from the perpendicularly oriented strain-gage pairs. Although the complex stress-strain behavior of decelerator fabrics prevents the attainment of normally expected strain-gage accuracy, utilization of the techniques described can lead to meaningful measurements for the decelerator stress analyst.

Hoffman, I. S.↗

An economical arterial-pulse-wave transducer

Transducer records arterial pulses externally. Device uses thin plastic membrane which is fluid coupled to pressure sensitive transistor. Transistor is connected to amplifier which, in turn, is connected to recorder. End section is threaded to accept suitable holder and contains pressure relief vent allowing transistor to sense only pressure levels greater than atmospheric.

Kim, C.↗