Engineering PapersSearch

SEARCH · Engineering Papers

Results for “thin film battery health”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

907 records · Page 13

A Review of Pump Package Assembly Anomalies and Demonstration to Gain Motor Controller Replacement Capability

The International Space Station (ISS) generates heat within the US modules from systems used to operate the station, maintain crew health, and conduct science experiments in the orbiting laboratory. The Internal Thermal Control System (ITCS) collects this heat in water loops and transfers it to the external ammonia system for rejection to space. The ITCS uses six Pump Package Assemblies (PPA) as the motive force to circulate the water within the Lab, Node 2, and Node 3 (Node 1 is parasitic to the Lab and Node 3 ITCS loops). In the life of ISS, 3 PPAs have had to be replaced and 2 PPAs are currently showing signs of degradation. The first PPA to fail in 2003 was due to early coolant chemistry issues; the remaining pump failures and current pump degradations are determined to be related to the Pump/Fan Motor Controller (PFMC), with their individual signatures all being unique to this point. The PFMC of one of the failed PPAs was returned and testing confirmed its sub-components to be the root cause of the PPA failure. Due to the relative size and weight of the standalone PFMC in comparison to the integrated assembly, it is desired, from a launch and on-orbit stowage perspective, to replace the PFMC component of the degraded PPA instead of the entire PPA. The PPA was not designed for this capability, so on the ground demonstrations are planned using crew tools to show that the PFMC can be replaced on-orbit while maintaining full functionality. This paper will focus on the signatures of the two most recent PPA failures and the two PPAs showing signs of degradation, in addition to presenting the findings from the PFMC demonstration effort.

Aaron Rodriguez

A Review of Pump Package Assembly Anomalies and Demonstration to Gain Motor Controller Replacement Capability

The International Space Station (ISS) generates heat within the US modules from systems used to operate the station, maintain crew health, and conduct science experiments in the orbiting laboratory. The Internal Thermal Control System (ITCS) collects this heat in water loops and transfers it to the external ammonia system for rejection to space. The ITCS uses six Pump Package Assemblies (PPA) as the motive force to circulate the water within the Lab, Node 2, and Node 3 (Node 1 is parasitic to the Lab and Node 3 ITCS loops). In the life of ISS, 3 PPAs have had to be replaced and 2 PPAs are currently showing signs of degradation. The first PPA to fail in 2003 was due to early coolant chemistry issues; the remaining pump failures and current pump degradations are determined to be related to the Pump/Fan Motor Controller (PFMC), with their individual signatures all being unique to this point. The PFMC of one of the failed PPAs was returned and testing confirmed its sub-components to be the root cause of the PPA failure. Due to the relative size and weight of the standalone PFMC in comparison to the integrated assembly, it is desired, from a launch and on-orbit stowage perspective, to replace the PFMC component of the degraded PPA instead of the entire PPA. The PPA was not designed for this capability, so on the ground demonstrations are planned using crew tools to show that the PFMC can be replaced on-orbit while maintaining full functionality. This paper will focus on the signatures of the two most recent PPA failures and the two PPAs showing signs of degradation, in addition to presenting the findings from the PFMC demonstration effort.

Aaron Rodriguez

High-resolution modeling of indoor radon exposure with uncertainty quantification in Utah

Indoor radon accounts for 37% of population-level exposure to ionizing radiation in the United States. However, radon metrics are typically reported at coarse spatial scales, potentially obscuring meaningful local variation. We developed a high-resolution modeling framework to estimate indoor radon concentrations across Utah while explicitly quantifying predictive uncertainty. A total of 19,497 residential radon measurements collected between 2006 and 2017 were combined with environmental and housing characteristics and analyzed using a geospatial neural network that accommodates spatial dependence and nonlinear associations. Predictions were generated on a uniform hexagonal grid at 0.73 km2 resolution (H3 level 8). Out-of-sample predictions aggregated to the H3 level 8 grid showed good agreement with observed concentrations (Pearson r=0.64), while household-level predictions exhibited more moderate agreement (r=0.45). The model produced well-calibrated uncertainty estimates, with 24.1% of held-out observations exceeding the predicted 75th-percentile threshold. Maps of predicted radon concentrations and the probability of exceeding the U.S. EPA action level of 148 Bq/m3 (4 pCi/L) revealed substantial fine-scale spatial heterogeneity that was not apparent in conventional coarse-resolution summaries, with greater local variability observed in densely monitored urban counties than in sparsely sampled regions. High-resolution radon models that explicitly quantify uncertainty provide a useful framework for characterizing the spatial distribution of indoor radon and identifying areas of elevated exceedance risk. These findings highlight the value of fine-scale monitoring data and uncertainty-aware modeling approaches for radon exposure assessment, environmental risk characterization, and radon-related health research.

Wu, Yunhan [ORNL] (ORCID:0000000178842994)

Actuating Liquid Crystals Rapidly and Reversibly by Using Chemical Catalysis

Abstract Microtubules and catalytic motor proteins underlie the microscale actuation of living materials, and they have been used in reconstituted systems to harness chemical energy to drive new states of organization of soft matter (e.g., liquid crystals (LCs)). Such materials, however, are fragile and challenging to translate to technological contexts. Rapid (sub‐second) and reversible changes in the orientations of LCs at room temperature using reactions between gaseous hydrogen and oxygen that are catalyzed by Pd/Au surfaces are reported. Surface chemical analysis and computational chemistry studies confirm that dissociative adsorption of H 2 on the Pd/Au films reduces preadsorbed O and generates 1 ML of adsorbed H, driving nitrile‐containing LCs from a perpendicular to a planar orientation. Subsequent exposure to O 2 leads to oxidation of the adsorbed H, reformation of adsorbed O on the Pd/Au surface, and a return of the LC to its initial orientation. The roles of surface composition and reaction kinetics in determining the LC dynamics are described along with a proof‐of‐concept demonstration of microactuation of beads. These results provide fresh ideas for utilizing chemical energy and catalysis to reversibly actuate functional LCs on the microscale.

Chemistry

Light-triggered electrochemical biosensor using singlet oxygen for self-powered operation and glucose detection

This study introduces a light-activated sensing strategy that integrates photosensitization with electrochemical detection. The sensor employs Eosin Y, a photosensitizer that generates singlet oxygen ( 1 O 2 ) via type II photosensitization. Immobilized within a thin polymer matrix on a carbon working electrode, Eosin Y produces 1 O 2 , under green light (520 nm) illumination, initiating a redox process that yields a measurable current. To incorporate biosensing capabilities and enable self-powered operation, this 1 O 2 – mediated process was coupled with glucose oxidase (GOx) to construct a fully operational glucose biosensor. The addition of glucose reverses the current flow by causing GOx to compete for electrons, with the resulting current magnitude correlating with glucose concentration providing a sensitive measure of glucose. The biosensor, as proof-of-principle, demonstrated excellent performance over a range of glucose concentrations (0–73 mM), achieving a detection limit (LOD) of 2.8 mM for steady state photocurrent under oxygen-saturated conditions. This platform leverages light and 1 O 2 as stimuli for tunable, on-demand signal control, offering a novel approach for adaptive, real-time biosensing technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH