ECAR-5367 Rev 0 Hydraulic Assessment of the Primary Coolant Test System Design
A MARVEL thermal-hydraulic analysis team has developed the computational fluid dynamicsmodel of the Primary Coolant Test (PCAT) system design based on the CAD drawing providedfrom INL PCAT design team. This ECAR addresses the hydraulic system characteristics(pressure loss and flow distribution) in the various sub-components of the PCAT design. Thisreport provides potential design optimization direction on the PCAT test. Most importantly, thisreport evaluates the feasibility of the natural circulation at the targeted heat balance between thecore and heat sink design.