At least 235 records · Page 13

Validation of 3D MHD simulations of Ne/D 2 mixed shattered pellet injection in JET

Nonlinear 3D magnetohydrodynamic (MHD) modeling of shattered pellet injection (SPI) in JET tokamak plasmas is performed with the JOREK code. The study focuses on the validation of simulation result with respect to experimental observations, addressing in particular figures of merit for the efficiency of the SPI, as a technique to mitigate thermal loads by injecting radiative impurities like neon during the thermal quench (TQ) phase of disruptions. A set of JET pulses with neon/deuterium atomic mixture ratio in the shattered pellet varying from 10% to 100% provides the experimental data to be compared with. Simulations using different models for the ablation of solid fragments and the radiation of neon impurities are considered. Synthetic diagnostics are employed for a direct quantitative comparison with key JET diagnostic systems providing in particular radiation, electron temperature and density, and magnetic measurements. 3D radiation structures from MHD simulations are analyzed to estimate the toroidal asymmetry of radiation, which is difficult to measure in JET due to the presence of only two toroidally displaced multi-channel bolometry systems. JOREK simulations show that, before the TQ, the bulk of the radiation is concentrated in a toroidal region enclosing the radiating fragments that is missed by both multi-channel bolometers, suggesting a possible underestimation of the total radiation by such diagnostic systems in the pre-TQ phase. On the other hand, JOREK predicts that during the TQ the radiation becomes more toroidally symmetric, with positive implications for the heat load to plasma facing components.

JOREK↗

Evaluation of thermal and mechanical loading effects on the structural behavior of a SiC/titanium composite

Composite specimens of titanium-15-3 matrix reinforced with continuous SCS-6 silicon carbide fibers were tested under a variety of thermal and mechanical loadings. A combined experimental/finite element approach was used to estimate the effective in-situ modulus of the matrix material and to evaluate changes in modulus due to the applied loads. Several fiber orientations were tested. Results indicate that the effect of the thermal loads on composite stiffness varies with fiber orientation. Applications of this method to test specimens damaged by uniaxial tension, thermal cycling, and isothermal fatigue loadings are used to illustrate that by monitoring overall structural behavior, changes in stiffness caused by thermomechanical loading can be detected.

Grady, Joseph E.↗

FEM Analysis of Hybrid LTS/HTS Cos-Theta Dipole Magnet

After the recent results on Bi-2212 superconductive magnets realized and tested in canted cosine-theta and solenoid designs, respectively, at Lawrence Berkeley National Laboratory (LBNL) and NHMFL, the first Bi-2212 stress-managed cosine-theta insert magnet is in the assembly phase at Fermilab. This insert will be part of the first hybrid cosine-theta magnet made of Nb3Sn outer layers within the US-MDP effort to reach 20 T bore field. This paper reports the analytical analysis of the cosine-theta Nb3Sn/Bi-2212 hybrid magnet. As an introduction, it shows the validation of the finalized HTS coils' design optimized using the ROXIE code. Subsequently, it reports the parameters, logic, and implementation method of the 2D electromagnetic and mechanical FEM analysis of the LTS/HTS hybrid magnet. Results from the ANSYS detailed model made with sub-modeling geometry are compared with the homogeneous model implemented in the past. Moreover, a Python code was implemented to simulate the current degradation due to stresses in the detail-modeled conductor areas. The current degradation is introduced in the simulation dynamics for both conductors as an iteration process during the energization load step only after applying pre-stress and thermal loads. The numerical and graphic results of the 2D cosine-theta LTS/HTS magnet cross-section will be described and analyzed.

D'Agliano, A.↗

Thrust Stand for Electric Propulsion Performance Evaluation

An electric propulsion thrust stand capable of supporting thrusters with total mass of up to 125 kg and 1 mN to 1 N thrust levels has been developed and tested. The mechanical design features a conventional hanging pendulum arm attached to a balance mechanism that transforms horizontal motion into amplified vertical motion, with accommodation for variable displacement sensitivity. Unlike conventional hanging pendulum thrust stands, the deflection is independent of the length of the pendulum arm, and no reference structure is required at the end of the pendulum. Displacement is measured using a non-contact, optical linear gap displacement transducer. Mechanical oscillations are attenuated using a passive, eddy current damper. An on-board microprocessor-based level control system, which includes a two axis accelerometer and two linear-displacement stepper motors, continuously maintains the level of the balance mechanism - counteracting mechanical %era drift during thruster testing. A thermal control system, which includes heat exchange panels, thermocouples, and a programmable recirculating water chiller, continuously adjusts to varying thermal loads to maintain the balance mechanism temperature, to counteract thermal drifts. An in-situ calibration rig allows for steady state calibration both prior to and during thruster testing. Thrust measurements were carried out on a well-characterized 1 kW Hall thruster; the thrust stand was shown to produce repeatable results consistent with previously published performance data.

Markusic, T. E.↗

Gas cooled faraday rotator and method

To enable several orders of magnitude increases in average power and energy handling capability of Faraday rotators, the technology utilizes high speed gas cooling to efficiently remove thermal loading from the Faraday optic faces while minimizing the thermal wavefront and thermal birefringence by creating a longitudinal thermal gradient. A recirculating gas cooling manifold accelerates the gas over the surface of the slab to create a turbulent flow condition which maximizes the surface cooling rate. The technology further provides a spatially uniform thermal profile on the Faraday slabs.

Bayramian, Andrew J.↗

Effects of static tensile load on the thermal expansion of Gr/PI composite material

The effect of static tensile load on the thermal expansion of Gr/PI composite material was measured for seven different laminate configurations. A computer program was developed which implements laminate theory in a piecewise linear fashion to predict the coupled nonlinear thermomechanical behavior. Static tensile load significantly affected the thermal expansion characteristics of the laminates tested. This effect is attributed to a fiber instability micromechanical behavior of the constituent materials. Analytical results correlated reasonably well with free thermal expansion tests (no load applied to the specimen). However, correlation was poor for tests with an applied load.

Farley, G. L.↗

The load-carrying and thermal characteristics of flat conductor cable

The load-carrying and thermal characteristics of flat conductor cable and round wire cables have been investigated with all conductors in each cable under varying loads in air and vacuum environments. The test procedure is described and results are presented in graphic form. Derating factors for both round wire and flat conductor cable are established for operation in a vacuum environment. Rating factors are established for flat conductor cable for use with round wire loading tables. The results of these tests show that single layer flat conductor size, or that the voltage drop across flat conductor cable will be lower than that of round cable under the same load.

Adams, G. D.↗

Nonlinear analyses of composite aerospace structures in sonic fatigue

The primary research effort of this project is the development of analytical methods for the prediction of nonlinear random response of composite aerospace structures subjected to combined acoustic and thermal loads. The progress, accomplishments, and future plans of three random response research topics are discussed, namely acoustics-structure interactions using boundary/finite element methods, nonlinear vibrations of beams and composite plates under harmonic and random excitations, and numerical simulation of the nonlinear response of composite plates under combined thermal and acoustic loading.

Mei, Chuh↗

Space Station thermal storage/refrigeration system research and development

Space Station thermal loading conditions represent an order of magnitude increase over current and previous spacecraft such as Skylab, Apollo, Pegasus III, Lunar Rover Vehicle, and Lockheed TRIDENT missiles. Thermal storage units (TSU's) were successfully used on these as well as many applications for ground based solar energy storage applications. It is desirable to store thermal energy during peak loading conditions as an alternative to providing increased radiator surface area which adds to the weight of the system. Basically, TSU's store heat by melting a phase change material (PCM) such as a paraffin. The physical property data for the PCM's used in the design of these TSU's is well defined in the literature. Design techniques are generally well established for the TSU's. However, the Space Station provides a new challenge in the application of these data and techniques because of three factors: the large size of the TSU required, the integration of the TSU for the Space Station thermal management concept with its diverse opportunities for storage application, and the TSU's interface with a two-phase (liquid/vapor) thermal bus/central heat rejection system. The objective in the thermal storage research and development task was to design, fabricate, and test a demonstration unit. One test article was to be a passive thermal storage unit capable of storing frozen food at -20 F for a minimum of 90 days. A second unit was to be capable of storing frozen biological samples at -94 F, again for a minimum of 90 days. The articles developed were compatible with shuttle mission conditions, including safety and handling by astronauts. Further, storage rack concepts were presented so that these units can be integrated into Space Station logistics module storage racks. The extreme sensitivity of spacecraft radiator systems design-to-heat rejection temperature requirements is well known. A large radiator area penalty is incurred if low temperatures are accommodated via a single centralized radiator system. As per the scope of work of this task, the applicability of refrigeration system tailored to meet the specialized requirements of storage of food and biological samples was investigated. The issues addressed were the anticipated power consumption and feasible designs and cycles for meeting specific storage requirements. Further, development issues were assessed related to the operation of vapor compression systems in micro-gravity addressing separation of vapor and liquid phases (via capillary systems).

Dean, W. G.↗

Community Geothermal: Borefield Design, Thermal Conductivity, and Subsurface Modeling Data - Chicago, IL

This dataset encompasses the development of a geothermal energy system for the West Woodlawn neighborhood in Chicago, Illinois. This project is part of a broader initiative to design and deploy geothermal heating and cooling systems at a community scale. The dataset includes thermal conductivity test results, calculations for borehole sizing based on the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) method, as well as simulated thermal loads based on actual energy usage from individual buildings. Also provided here are files used for numerical modeling via COMSOL Multiphysics to simulate borefield design and subsurface thermal behavior. Two manuscripts are attached, which outline the broad objectives of the project and a description of the numerical modeling methodology and results.

15 GEOTHERMAL ENERGY↗

Determination of permissible applied load stress in structural elements

Graphic method is used to select allowable stresses in thermally loaded structures. Equations are used for determining the mode of failure for specific materials in order to plot a range of stress curves. Linear assumption and iterative calculations are eliminated resulting in comparatively high accuracy.

Loy, R. E.↗

Calculation of Thermally-Induced Displacements in Spherically Domed Ion Engine Grids

An analytical method for predicting the thermally-induced normal and tangential displacements of spherically domed ion optics grids under an axisymmetric thermal loading is presented. A fixed edge support that could be thermally expanded is used for this analysis. Equations for the displacements both normal and tangential to the surface of the spherical shell are derived. A simplified equation for the displacement at the center of the spherical dome is also derived. The effects of plate perforation on displacements and stresses are determined by modeling the perforated plate as an equivalent solid plate with modified, or effective, material properties. Analytical model results are compared to the results from a finite element model. For the solid shell, comparisons showed that the analytical model produces results that closely match the finite element model results. The simplified equation for the normal displacement of the spherical dome center is also found to accurately predict this displacement. For the perforated shells, the analytical solution and simplified equation produce accurate results for materials with low thermal expansion coefficients.

Soulas, George C.↗

Passive Thermal Control of the Primordial Inflation Polarization Explorer (PIPER) Flight Electronics

The scientific balloon program at NASA offers an exciting and open area of opportunity for testing new technologies and for conducting meaningful experimentation at a fraction of the cost of a space mission. This paper outlines a simple thermal model developed and employed for the Primordial Inflation Polarization ExplorER (PIPER). The sub-orbital environment that PIPER operates in hosts an interesting mix of atmospheric and space thermal challenges. The work done was to mitigate thermal loads and passively cool the payload's exterior mounted electronics at an altitude of 36.6 km. This was done by characterizing the thermal environment and then designing solutions for the heat loads through a combined radiation and conduction passive cooling radiator system thermal model. Despite the simplicity and subsequent limitations of the model, as well as some unexpected payload operational events, the model produced results between 0.31% and 11.8% difference between the predicted values and measured average temperatures. From these results, the model was able to successfully provide estimates for the electronics temperatures. Additional flights will be needed to eliminate unknowns encountered in this flight in order to further refine the model for higher accuracy.

Walts, Alexander R.↗

Design of a novel carbon/carbon composite microvascular solar receiver

Solar thermal power tower systems are the primary technology being proposed for solar electricity from thermal energy. Operational limits on these towers are often driven by mechanical properties under significant thermal loads, particularly at the receiver where incoming flux is converted to thermal energy. While the solar receiver’s efficiency is largely driven by its optical properties, thermomechanical stresses on the receiver limits the operational envelope. One pathway to higher efficiency is greater allowable solar fluxes on the receiver but novel materials are required. The present study uses computational fluid dynamics to describe a parametric design space for a microvascular carbon/carbon composite solar receiver as a new material option for high flux solar receivers. Simulations are conducted for different microvascular geometries considering the role of material properties and heat transfer fluids, for the impact on thermal efficiency, and allowable strain. Results show that microscale receiver modules made of the proposed carbon/carbon composite could achieve thermal efficiencies over 90% and full-scale receivers can achieve up to 85% thermal efficiency for the design explored considering realistic strain limits, flux levels, and material properties. These values are highly dependent on the heat transfer fluid pairing, the through plane thermal conductivity of the carbon/carbon composite, the path architecture of the microscale receiver, and the incident solar flux profiles.

14 SOLAR ENERGY↗

srlife: A Fast Tool for High Temperature Receiver Design and Analysis

This report describes a tool for estimating the structural service life of tubular, panel solar receivers operating at high temperatures. A complete version of the tool is available as open source software at https://github.com/Argonne-National-Laboratory/srlife and can be installed through the PyPi (https://pypi.org) package manager. Given the basic receiver geometry and the thermal loads on the receiver, the tool provides 1D, 2D, or 3D thermal and structural (single tube and simplified system) analysis and creep-fatigue service life prediction for six metallic alloys – 316H, 800H, Alloy 617, Alloy 740H, and Alloy 230. With the exception of Alloy 230 where the material data is preliminary, the software included a detailed set of models for the materials, well-supported by high temperature experimental test data. The tool is designed for easy integration with a software stack, including solar field and thermohydraulic simulations, for optimizing receiver designs to meet service life and economic targets. The report describes several heuristics that can be applied in srlife to reduce the analysis time by several orders of magnitude but with fairly accurate life estimation when compared with full analysis. The report provides several examples demonstrating the utility of srlife in receiver design. Finally, the report discusses high temperature tests on Alloy 282, collected as part of this project, used to develop and support the material model for that alloy.

47 OTHER INSTRUMENTATION↗

Finite-element computer program for axisymmetric loading situations where components may have a relative interference fit

A finite element computer program which enables the analysis of distortions and stresses occurring in compounds having a relative interference is presented. The program is limited to situations in which the loading is axisymmetric. Loads arising from the interference fit(s) and external, inertial, and thermal loadings are accommodated. The components comprise several different homogeneous isotropic materials whose properties may be a function of temperature. An example illustrating the data input and program output is given.

Taylor, C. M.↗

Thermal modeling of the NASA-Ames Research Center Cryogenic Optical Test Facility and a single-arch, fused-natural-quartz mirror

A thermal model of the dewar and optical system of the Cryogenic Optical Test Facility at NASA-Ames Research Center was developed using the computer codes SINDA and MONTE CARLO. The model was based on the geometry, boundary conditions, and physical properties of the test facility and was developed to investigate heat transfer mechanisms and temperatures in the facility and in test mirrors during cryogenic optical tests. A single-arch, fused-natural-quartz mirror was the first mirror whose thermal loads and temperature distributions were modeled. From the temperature distribution, the thermal gradients in the mirror were obtained. The model predicted that a small gradient should exist for the single arch mirror. This was later verified by the measurement of mirror temperatures. The temperatures, predicted by the model at various locations within the dewar, were in relatively good agreement with the measured temperatures. The model is applicable to both steady-state and transient cooldown operations.

Ng, Y. S.↗