Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A probe for measuring temperature and pressure at the same points in a gas stream

Design features and characteristics of a means for measuring total temperature and total pressure at a single point in a gas stream are presented. A rake that provides five such combination measurements is described. Experimental data are included for the aerodynamic recovery and time response of the temperature sensor and for the flow-angle sensitivity of both the temperature and pressure sensors. Data were obtained over a subsonic Mach number range of 0.3 to 0.9 as well as at a Mach number of 1.4.

Krause, L. N.↗

TPSAS-NF1676L-11812-DND

Reducing the weight of spacecraft will reduce the fabrication costs and the launch costs . The elimination of wiring and wiring harnesses reduces the total mass of the vehicle . Wireless sensor technology can reduce the weight and therefore the costs of spacecraft . The Decadal Survey of Civil Aeronautics survey identified that "self-powered, wireless microelectromechanical sensors" warrant attention over the next decade . Current wireless sensor systems have low data rates and require batteries. The environment of aerospace vehicles is often very harsh, with temperature extremes ranging from cryogenic to very high temperatures during re-entry. For example, X-37B mini unmanned shuttle will require high temperature sensors mounted on the structure, as well as cryogenic sensors for monitoring fuel tanks. Batteries do not work well in either temperature extremes. Also, sensors are typically located in internal structures with limited access, making the periodic changing of batteries costly and time consuming. Passive wireless sensors are needed that operate across an extremely large temperature range and do not require batteries. NASA recently instrumented an all Composite Crew Module for structural testing on the ground. Wireless sensors could have reduced the time to instrument the module and check out the sensor wiring.

W (Cy) Wilson↗

Evaluation of thermal network correction program using test temperature data

An evaluation process to determine the accuracy of a computer program for thermal network correction is discussed. The evaluation is required since factors such as inaccuracies of temperatures, insufficient number of temperature points over a specified time period, lack of one-to-one correlation between temperature sensor and nodal locations, and incomplete temperature measurements are not present in the computer-generated information. The mathematical models used in the evaluation are those that describe a physical system composed of both a conventional and a heat pipe platform. A description of the models used, the results of the evaluation of the thermal network correction, and input instructions for the thermal network correction program are presented.

Ishimoto, T.↗

Total Temperature Measurements Using a Rearward Facing Probe in Supercooled Liquid Droplet and Ice Crystal Clouds

Engine Icing Performance loss: rollback, surge, flameout, and even internal engine damagePartial melting and refreeze of ice inside engine core (Mason et al., 2006). Ingestion of ice crystals and aggregates, mixed-phase droplets, or supercooled liquid dropletsNeed to better understand the conditions and properties that lead to engine icing.Simulation and analysis (physical and computational, and modeling)Test facilities (PSL, NRC, ...). Thermal and computational models and analysisProbesMultiple probes (aerothermal probes and ice cloud characterization probes and techniques). Total temperatureTraditional total temperature probes (vented forward facing)Heated total temperature probes (Goodyear). Rearward facing (developmental). Total temperature relevance. Thermal interaction between the icing cloud and air flow impinging particles contribute to kinetic heating effect (Gent et al., 2000). Measurement considerations Temperature sensor accuracy. Incomplete recovery of total temperature. Thermal surfaces (sources and sinks). Flow effects (viscous losses). Debris contamination, including icing and ice ingestion.

Agui, Juan H.↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018. Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zoned results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space environment Simulator (SES). The flight external radiators are not available during ISIM-level thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided by specially designed test hardware which also measures the heat flow within each of the five heat straps to an accuracy of less than 2 mW, which is less than 5% of the minimum predicted heat flow values. Measurement of the heat loads to this accuracy is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. It also provides direct verification by test of several high-level thermal requirements. Devices that measure heat flow in this manner have historically been referred to a "Q-meters". Perhaps the most important feature of the design of the JWST Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on knowledge of precise heater power required to maintain a constant temperature difference between sensors on two stages, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper provides a brief review of Q-meter design, and discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗

Automated Cryocooler Monitor and Control System

A system was designed to automate cryogenically cooled low-noise amplifier systems used in the NASA Deep Space Network. It automates the entire operation of the system including cool-down, warm-up, and performance monitoring. The system is based on a single-board computer with custom software and hardware to monitor and control the cryogenic operation of the system. The system provides local display and control, and can be operated remotely via a Web interface. The system controller is based on a commercial single-board computer with onboard data acquisition capability. The commercial hardware includes a microprocessor, an LCD (liquid crystal display), seven LED (light emitting diode) displays, a seven-key keypad, an Ethernet interface, 40 digital I/O (input/output) ports, 11 A/D (analog to digital) inputs, four D/A (digital to analog) outputs, and an external relay board to control the high-current devices. The temperature sensors used are commercial silicon diode devices that provide a non-linear voltage output proportional to temperature. The devices are excited with a 10-microamp bias current. The system is capable of monitoring and displaying three temperatures. The vacuum sensors are commercial thermistor devices. The output of the sensors is a non-linear voltage proportional to vacuum pressure in the 1-Torr to 1-millitorr range. Two sensors are used. One measures the vacuum pressure in the cryocooler and the other the pressure at the input to the vacuum pump. The helium pressure sensor is a commercial device that provides a linear voltage output from 1 to 5 volts, corresponding to a gas pressure from 0 to 3.5 MPa (approx. = 500 psig). Control of the vacuum process is accomplished with a commercial electrically operated solenoid valve. A commercial motor starter is used to control the input power of the compressor. The warm-up heaters are commercial power resistors sized to provide the appropriate power for the thermal mass of the particular system, and typically provide 50 watts of heat. There are four basic operating modes. "Cool " mode commands the system to cool to normal operating temperature. "Heat " mode is used to warm the device to a set temperature near room temperature. "Pump " mode is a maintenance function that allows the vacuum system to be operated alone to remove accumulated contaminants from the vacuum area. In "Off " mode, no power is applied to the system.

Britcliffe, Michael J.↗

Correlation of microthermal turbulence data with meteorological soundings in the troposphere.

Recent measurements of vertical profiles of microthermal turbulence structure are reported. Data obtained by balloon-borne temperature sensors are presented in terms of the temperature structure coefficient. Free-floating balloon flights allowed this type of measurement to be extended to an altitude of 15 km above sea level. This series of flights was accompanied by vertical profiles of wind speed and temperature that permitted calculation of wind shear and gradient Richardson number profiles. The observed correlations found to exist between microthermal turbulence layers and the standard meteorological data are discussed briefly in light of the theory.

Bufton, J. L.↗

Temperature control in wafer-level testing of large multi-segment electromigration test structures

The paper describes two methods for maintaining a constant metallization temperature throughout a wafer-level isothermal electromigration test of large multisegment test structures where Joule-heating is high and chip to chuck thermal contact is poor. In the first method, an initial calibration of Joule heating versus metal temperature is carried out. During the isothermal electromigration test, the Joule heating is continuously monitored and the chuck temperature is adjusted based on the calibration results to maintain a constant metal temperature. In the second method, temperature sensors are fabricated on the chip and then the sensors are used to monitor the chip temperature directly. The chuck temperature is then adjusted as needed.

Zamani, Nasser↗

MOBY, A Radiometric Buoy for Performance Monitoring and Vicarious Calibration of Satellite Ocean Color Sensors: Measurement and Data Analysis Protocols

The Marine Optical Buoy (MOBY) is the centerpiece of the primary ocean measurement site for calibration of satellite ocean color sensors based on independent in situ measurements. Since late 1996, the time series of normalized water-leaving radiances L(sub WN)(lambda) determined from the array of radiometric sensors attached to MOBY are the primary basis for the on-orbit calibrations of the USA Sea-viewing Wide Field-of-view Sensor (SeaWiFS), the Japanese Ocean Color and Temperature Sensor (OCTS), the French Polarization Detection Environmental Radiometer (POLDER), the German Modular Optoelectronic Scanner on the Indian Research Satellite (IRS1-MOS), and the USA Moderate Resolution Imaging Spectrometer (MODIS). The MOBY vicarious calibration L(sub WN)(lambda) reference is an essential element in the international effort to develop a global, multi-year time series of consistently calibrated ocean color products using data from a wide variety of independent satellite sensors. A longstanding goal of the SeaWiFS and MODIS (Ocean) Science Teams is to determine satellite-derived L(sub WN)(labda) with a relative combined standard uncertainty of 5 %. Other satellite ocean color projects and the Sensor Intercomparison for Marine Biology and Interdisciplinary Oceanic Studies (SIMBIOS) project have also adopted this goal, at least implicitly. Because water-leaving radiance contributes at most 10 % of the total radiance measured by a satellite sensor above the atmosphere, a 5 % uncertainty in L(sub WN)(lambda) implies a 0.5 % uncertainty in the above-atmosphere radiance measurements. This level of uncertainty can only be approached using vicarious-calibration approaches as described below. In practice, this means that the satellite radiance responsivity is adjusted to achieve the best agreement, in a least-squares sense, for the L(sub WN)(lambda) results determined using the satellite and the independent optical sensors (e.g. MOBY). The end result of this approach is to implicitly absorb unquantified, but systematic, errors in the atmospheric correction, incident solar flux, and satellite sensor calibration into a single correction factor to produce consistency with the in situ data.

Clark, Dennis K.↗

Towards an Automated Unstructured Grid Adaptation Workflow with VULCAN

Early work is presented for an unstructured grid adaptation workflow with VULCAN and refine. Anisotropic simplex grids are iteratively adapted to match a Riemannian metric tensor field describing desired mesh spacing. The Riemannian metric tensor field is obtained from Hessians of CFD solution output scalar sensor fields; both Mach number and static temperature sensor fields are explored. In addition, we describe a Newton-method-based solver recently implemented in VULCAN utilizing Jacobian-Free-Newton-Krylov that can be used to increase flow solver automation on early grids in the adadptation process. Hypersonic flow solutions are presented on a high Reynolds number flat plate and wall heat flux is compared against a highly resolved structured solution. Additionally, complex shock boundary-layer interaction is explored in a high Mach number compression corner and complex 3D flow phenomena are evaluated on the Boundary Layer Transition (BOLT) vehicle.

Matthew O'Connell↗

Experimental Capabilities and Achievements of the Space Environment Dynamometer (SED)

The Space Environment Dynamometer (SED) chamber was designed to conduct research in cryobotics; an area of study that focuses on robotic systems and rotating machinery operating in extreme cold environments including Earth, low Earth orbit, Mars, Moon, asteroids, Solar orbit, planetary orbit, or those encountered during travel among these destinations. The test chamber incorporates a modular dynamometer, consisting of a variety of brakes, torque sensors and motors to be easily interchanged between tests. Each test employs a unique test profile that incorporates different setpoints of applied torques and velocities for a given period or number of rev- olutions. The modularity of the dynamometer setup allows for any combination of motor, gearbox to be tested. This chamber is one of a kind and resides at the Swamp Works facility within the Granular Mechanics and Regolith Operations laboratory (GMRO) at NASA Kennedy Space Center. Other cold chambers exist, however they are project specific and do not simultaneously output real time torque, temperature and efficiency data. The modularity of this extreme cold environment test chamber, coupled with the custom software and instrumentation, makes it one of a kind. The chamber is capable of stabilizing cryogenic temperatures and pressures to commensurate moon environments. Tests have successfully been conducted on motors and gearboxes for various cryogenic temperature set points, torques, and angular velocities. Relevant internal temperatures of the test article and chamber were recorded using a variety of temperature sensors. The temperature setpoints, on the motors and gearboxes tested, were stabilized by using PID gain scheduling of the PWM signal for the various heaters. The heat removal for the motor was provided by creating a thermally conductive path from a cryohead directly to the test article using copper straps. A variety of strainwave gears (SWGs), also known as Harmonic drives, planetary gear systems and DC motor actuator configurations have been tested in the chamber. The experiments performed were for various projects including Bulk Metallic Glass Gears (BMGG), Volatiles Investigating Polar Exploration Rover (VIPER), In-Situ Resource Utilization Pilot Excavator (IPEX) . Various upgrades have been made to the extreme cold environment test chamber for the use of cryobotic research. These upgrades greatly increased the autonomous capabilities of the test set up by providing redundancies in the hardware and software. The redundancies were primarily added to protect the integrity of the cryohead. A new strapping and insulation method was performed to create the thermal conductive path from the actuators to the cryohead. The software was upgraded to include temperature setpoint control, further increasing the autonomous capabilities of the test. This paper goes into detail regarding the upgrades made to the extreme cold environment test chamber, as well as highlights the results from a COLDArm acceptance test.

Casey J. Clark↗

Microelectromechanical Systems (MEMS) Broadband Light Source Developed

A miniature, low-power broadband light source has been developed for aerospace applications, including calibrating spectrometers and powering miniature optical sensors. The initial motivation for this research was based on flight tests of a Fabry-Perot fiberoptic temperature sensor system used to detect aircraft engine exhaust gas temperature. Although the feasibility of the sensor system was proven, the commercial light source optically powering the device was identified as a critical component requiring improvement. Problems with the light source included a long stabilization time (approximately 1 hr), a large amount of heat generation, and a large input electrical power (6.5 W). Thus, we developed a new light source to enable the use of broadband optical sensors in aerospace applications. Semiconductor chip-based light sources, such as lasers and light-emitting diodes, have a relatively narrow range of emission wavelengths in comparison to incandescent sources. Incandescent light sources emit broadband radiation from visible to infrared wavelengths; the intensity at each wavelength is determined by the filament temperature and the materials chosen for the filament and the lamp window. However, present commercial incandescent light sources are large in size and inefficient, requiring several watts of electrical power to obtain the desired optical power, and they emit a large percentage of the input power as heat that must be dissipated. The miniature light source, developed jointly by the NASA Glenn Research Center, the Jet Propulsion Laboratory, and the Lighting Innovations Institute, requires one-fifth the electrical input power of some commercial light sources, while providing similar output light power that is easily coupled to an optical fiber. Furthermore, it is small, rugged, and lightweight. Microfabrication technology was used to reduce the size, weight, power consumption, and potential cost-parameters critical to future aerospace applications. This chip-based light source has the potential for monolithic fabrication with on-chip drive electronics. Other uses for these light sources are in systems for vehicle navigation, remote sensing applications such as monitoring bridges for stress, calibration sources for spectrometers, light sources for space sensors, display lighting, addressable arrays, and industrial plant monitoring. Two methods for filament fabrication are being developed: wet-chemical etching and laser ablation. Both yield a 25-mm-thick tungsten spiral filament. The proof-of-concept filament shown was fabricated with the wet etch method. Then it was tested by heating it in a vacuum chamber using about 1.25 W of electrical power; it generated bright, blackbody radiation at approximately 2650 K. The filament was packaged in Glenn's clean-room facilities. This design uses three chips vacuum-sealed with glass tape. The bottom chip consists of a reflective film deposited on silicon, the middle chip contains a tungsten filament bonded to silicon, and the top layer is a transparent window. Lifetime testing on the package will begin shortly. The emitted optical power is expected to be approximately 1.0 W with the spectral peak at 1.1 mm.

Tuma, Margaret L.↗

Pressure-Sensor Assembly Technique

Nielsen Engineering & Research (NEAR) recently developed an ultrathin data acquisition system for use in turbomachinery testing at NASA Glenn Research Center. This system integrates a microelectromechanical- systems- (MEMS-) based absolute pressure sensor [0 to 50 psia (0 to 345 kPa)], temperature sensor, signal-conditioning application-specific integrated circuit (ASIC), microprocessor, and digital memory into a package which is roughly 2.8 in. (7.1 cm) long by 0.75 in. (1.9 cm) wide. Each of these components is flip-chip attached to a thin, flexible circuit board and subsequently ground and polished to achieve a total system thickness of 0.006 in. (0.15 mm). Because this instrument is so thin, it can be quickly adhered to any surface of interest where data can be collected without disrupting the flow being investigated. One issue in the development of the ultrathin data acquisition system was how to attach the MEMS pressure sensor to the circuit board in a manner which allowed the sensor s diaphragm to communicate with the ambient fluid while providing enough support for the chip to survive the grinding and polishing operations. The technique, developed by NEAR and Jabil Technology Services Group (San Jose, CA), is described below. In the approach developed, the sensor is attached to the specially designed circuit board, see Figure 1, using a modified flip-chip technique. The circular diaphragm on the left side of the sensor is used to actively measure the ambient pressure, while the diaphragm on the right is used to compensate for changes in output due to temperature variations. The circuit board is fabricated with an access hole through it so that when the completed system is installed onto a wind tunnel model (chip side down), the active diaphragm is exposed to the environment. After the sensor is flip-chip attached to the circuit board, the die is underfilled to support the chip during the subsequent grinding and polishing operations. To prevent this underfill material from getting onto the sensor s diaphragms, the circuit board is fabricated with two 25- micrometer-tall polymer rings, sized so that the diaphragms fit inside the rings once the chip is attached.

Pruzan, Daniel A.↗

Comparison between S. T. radar and in situ balloon measurements

A campaign for simultaneous in situ and remote observation of both troposphere and stratosphere took place near Aire-sur-l'Adour (in southeastern France) on May 4, 1984. The aim of this campaign was a better understanding of the physics of radar echoes. The backscattered signal obtained with a stratosphere-troposphere radar both at the vertical and 15 deg. off vertical is compared with the velocity and temperature measurements made in the same region (about 10 km north of the radar site) by balloon-borne ionic anenometers and temperature sensors. In situ measurements clearly indicate that the temperature fluctuations are not always consistent with the standard turbulent theory. Nevertheless, the assumptions generally made (isotropy and turbulent field in k) and the classical formulation so derived for radar reflectivity are able to reproduce the shape of the radar return power profiles in oblique directions. Another significant result is the confirmation of the role played by the atmospheric stratification in the vertical echo power. It is important to develop these simultaneous in situ and remote experiments for a better description of the dynamical and thermal structure of the atmosphere and for a better understanding of the mechanisms governing clear-air radar reflectivity.

Dalaudier, F.↗

Spectrum-modulating fiber-optic sensors for aircraft control systems

A family of fiber-optic sensors for aircraft engine control systems is described. Each of these sensors uses a spectrum-modulation method to obtain an output which is largely independent of the fiber link transmissivity. A position encoder is described which uses a code plate to digitally modulate the sensor output spectrum. Also described are pressure and temperature sensors, each of which uses a Fabry-Perot cavity to modulate the sensor output spectrum as a continuous function of the measurand. A technique is described whereby a collection of these sensors may be effectively combined to perform a number of the measurements which are required by an aircraft-engine control system.

Beheim, Glenn↗

Ocean Drifter Project

Four drifting buoys were fabricated from mostly local hardware plus animal locating transmitters. The first two working models were dropped from a Wallops aircraft, to test the mechanical integrity and to test the ability of the whole system to withstand the drop and provide usable data. There are two temperature sensors on board, one to measure sea surface temperature and the other to measure air temperature. An onboard computer controls the transmissions, sending three water temperature readings for each air temperature reading in order to differentiate one from the other after data reduction. Guidelines for the development and test of optical drifting buoys include: air deployable and expendable, reasonable cost for multiple deployment, 1 year lifetime, use of existing technology and a minimal validation parameter set.

Mason, C. D.↗