Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Use of the WECC WAMS in Wide Area Probing Tests for Validation of System Performance & Modeling

During 2005 and 2006 the Western Electricity Coordinating Council (WECC) performed three major tests of western system dynamics. These tests used a Wide Area Measurement System (WAMS) based primarily on Phasor Measurement Units (PMUs) to determine response to events including the insertion of the 1400-MW Chief Joseph braking resistor, probing signals, and ambient events. Test security was reinforced through real-time analysis of wide area effects, and high-quality data provided dynamic profiles for interarea modes across the entire western interconnection. The tests established that low-level optimized pseudo-random ±20-MW probing with the Pacific DC Intertie (PDCI) roughly doubles the apparent noise that is natural to the power system, providing sharp dynamic information with negligible interference to system operations. Such probing is an effective alternative to use of the 1400-MW Chief Joseph dynamic brake, and it is under consideration as a standard means for assessing dynamic security.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-objective optimization of low-GWP mixture composition and heat exchanger circuitry configuration for improved system performance and reduced refrigerant flammability

The recently introduced hydrofluoroolefin (HFO) refrigerants, including R1234yf and R1234ze(E), have significantly lower global warming potentials (GWPs) than traditional hydrofluorocarbon (HFC) refrigerants like R410A. However, prior tests show that direct drop-in of pure R1234yf or R1234ze(E) into equipment designed for R410A results in a decrease in heat exchanger capacity and the system coefficient of performance. The primary reason is the lower in-tube heat transfer performance of R1234yf and R1234ze(E) compared with that of R410A. To address this issue, previous studies have mixed the mildly flammable HFC R32 with HFOs to improve system performance, with HFC R125 also added to suppress flammability. Previous studies selected compositions based on simple cycle analyses and did not consider modifications of the heat exchanger circuitry configuration to adapt to the new refrigerants. This study presents a novel multi-objective optimization approach to design a refrigerant composition that maximizes energy efficiency within flammability and GWP limits. The approach in this work simultaneously optimizes mixture composition and heat exchanger circuitry configuration. A case study on a rooftop unit indicates that, compared with mixture-only optimization, simultaneous optimization of mixture and heat exchanger circuitry yields a 5.9% improvement in cycle efficiency and a 48.6% reduction in refrigerant flammability with a GWP of 268. Circuitry optimization using refrigerants with different temperature glides shows that the larger the temperature glide is, the larger EER improvement is obtained. The results show that zeotropic blends with a large temperature glide are more sensitive to the refrigerant circuitry than pure refrigerants and may suffer significant performance degradation with subpar heat exchanger circuitry design. The proposed optimization approach is generally applicable to mixtures with any number of components. Using this approach to design a HVAC system can yield higher system efficiency within flammability and GWP constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits of digitalizing and employing simulation to increase plant system performance and ensure compliance with technical specifications - 109

The essential services water system in a BWR nuclear power plant was affected by corrosion, soiling and blockages due to ageing. Those episodes affected safety margins hindering the Technical Specifications compliance during periodic system testing. Tecnatom designed, implemented and tested a design modification for the on-line monitoring of this system by integrating it in the existing Digital Control System (DCS). Key system parameters were acquired in real time to be displayed in the Human System Interface, used in performing calculations and stored their historical evolution. The objective was to optimize monitoring and surveillance of the essential service water system. Furthermore, Tecnatom developed an engineering simulator ('What if' simulator) consisting of a hydraulic model of the system. This simulator takes as inputs each heat exchanger performance parameters from the plant DCS, allows the user to change the essential services water system configuration (valves position, UHS level...) and calculates theoretical process values predicting the system real behavior. In a second stage, more system instruments were wired to the DCS for Technical Specifications compliance automatic surveillance regarding opening and closing times of system valves. Operating experience shows important benefits after the digitalization. It enhances on-line information of system operation and automates calculation of load loss factor of each heat exchanger. It eases the evaluation of blockages and soiling in the system allowing optimization of cleaning proceedings. System Surveillance Requirements and Test Requirements reports have been automated optimizing the operation workload. The simulator use enables to identify optimal system configuration increasing safety margins of the system and ensuring Technical Specifications fulfillment. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A 194nW Energy-Performance-Aware loT SoC Employing a 5.2nW 92.6% Peak Efficiency Power Management Unit for System Performance Scaling, Fast DVFS and Energy Minimization

A self-powered IoT system-on-chip (SoC) reduces power to sub-μw and employs multiple power-management techniques to trade-off ultra-low power (ULP), higher performance, smaller energy harvester footprint, and longer operating lifetime. Minimum Energy Point Tracking (MEPT) [1]–[4] keeps an SoC operating at the minimum energy point (MEP) to enhance system lifetime. Previous sample-and-hold MEPT schemes need frequent voltage comparisons and a high-frequency clock that increases power [2]. Current-ratio-based MEPT relies on specialized CMOS technology for body-bias tuning [3]. A switched-capacitor-based MEPT can achieve energy minimization at a targeted performance [4], but it uses a 30MHz clock witμW power consumption and low power efficiency. For ULP IoT applications, SoCs need to have ultra-low quiescent power, high efficiency for energy delivery, performance scaling based on available energy, and energy minimization to increase system lifetime. In this work, we propose an ULP IoT SoC with a triple-mode power management unit (PMU) that integrates energy-performance scaling, event-driven fast DVFS, and MEPT features to improve the system energy efficiency, as shown in Fig. 13.8.1. This work achieves a minimum 194nW power consumption for the SoC and 5.2nW quiescent power for the PMU with a 92.6% peak efficiency and >10 4 dynamic range. The timing waveform in Fig. 13.8.1 (bottom), demonstrates the transition of the three modes including energy aware (EA), performance aware (PA), and MEPT based on event priority and input voltage level which reflects the energy availability. As such, the system energy consumption and performance could be well-balanced based on both the input and output conditions.

self-powered IoT system-on-chip (SoC)↗

A simple model of PV system performance and its use in fault detection

Results are presented from a monitoring study of the performance of a sample of UK domestic PV systems. Five-minute average climatic and performance data was recorded for 27 PV systems at two sites for up to 2 years of operation. On average, the annual energy losses due to faults were 3.6% (Site A, first year of operation), 6.6% (Site A, second year of operation) and 18.9% (Site B, first year of operation). Simple empirical models are constructed to describe the performance of the PV systems under 'normal operation' (when no faults occur). New analysis techniques are developed which estimate the energy losses of four different fault categories: sustained zero efficiency faults; brief zero efficiency faults; shading; and non-zero efficiency non-shading faults. The results demonstrate that faults have the potential to cause significant energy losses in domestic PV systems. The benefits of applying the data analysis techniques described in this work to PV system clusters and other urban micro-generation technologies are discussed. (author)

14 SOLAR ENERGY↗

Geometrical-Based Navigation System Performance Assessment in the Space Service Volume Using a Multiglobal Navigation Satellite System Methodology

NASA is participating in the International Committee on Global Navigation Satellite Systems (GNSS) (ICG)'s efforts towards demonstrating the benefits to the space user in the Space Service Volume (SSV) when a multi-GNSS solution space approach is utilized. The ICG Working Group: Enhancement of GNSS Performance, New Services and Capabilities has started a three phase analysis initiative as an outcome of recommendations at the ICG-10 meeting, in preparation for the ICG-11 meeting. The first phase of that increasing complexity and fidelity analysis initiative is based on a pure geometrically-derived access technique. The first phase of analysis has been completed, and the results are documented in this paper.

Global Positioning System↗

Artemis III and IV Crew Health and Performance System Model Development

To maintain Crew Health and Performance (CHP) during an Artemis mission, the NASA Human Research Program (HRP) and Exploration Medical Capabilities (ExMC) element recognize the challenge that many different vehicles, habitats, and operational groups must come together to develop and implement cross program capabilities. To address this challenge, the ExMC team created the prototype 2023 Artemis CHP System Model to analyze how human system requirements are implemented throughout an Artemis mission and help understand the effects of changing an individual vehicle or habitat requirement on a full mission. Since presenting this work at the 2024 HRP Investigators’ Workshop, ExMC has continued this effort, now called the Artemis III and IV CHP System Model, to better support its operational end users within the NASA Human Health and Performance Directorate (HHPD) workforce. In this presentation, we will recapitulate how visualizing requirements and their relationships using a Model-Based Systems Engineering approach (MBSE) serves to improve understanding of an Artemis mission’s CHP capabilities along with discussion on updates made to the model to increase accessibility for users within HHPD so that it may be used in the development of cross program CHP capabilities at NASA.

Crew Health and Performance↗

Orion Launch Abort System Performance During Exploration Flight Test 1

The Orion Launch Abort System Office is taking part in flight testing to enable certification that the system is capable of delivering the astronauts aboard the Orion Crew Module to a safe environment during both nominal and abort conditions. Orion is a NASA program, Exploration Flight Test 1 is managed and led by the Orion prime contractor, Lockheed Martin, and launched on a United Launch Alliance Delta IV Heavy rocket. Although the Launch Abort System Office has tested the critical systems to the Launch Abort System jettison event on the ground, the launch environment cannot be replicated completely on Earth. During Exploration Flight Test 1, the Launch Abort System was to verify the function of the jettison motor to separate the Launch Abort System from the crew module so it can continue on with the mission. Exploration Flight Test 1 was successfully flown on December 5, 2014 from Cape Canaveral Air Force Station's Space Launch Complex 37. This was the first flight test of the Launch Abort System preforming Orion nominal flight mission critical objectives. The abort motor and attitude control motors were inert for Exploration Flight Test 1, since the mission did not require abort capabilities. Exploration Flight Test 1 provides critical data that enable engineering to improve Orion's design and reduce risk for the astronauts it will protect as NASA continues to move forward on its human journey to Mars. The Exploration Flight Test 1 separation event occurred at six minutes and twenty seconds after liftoff. The separation of the Launch Abort System jettison occurs once Orion is safely through the most dynamic portion of the launch. This paper will present a brief overview of the objectives of the Launch Abort System during a nominal Orion flight. Secondly, the paper will present the performance of the Launch Abort System at it fulfilled those objectives. The lessons learned from Exploration Flight Test 1 and the other Flight Test Vehicles will certainly contribute to the vehicle architecture of a human-rated space launch vehicle.

McCauley, Rachel↗

SPS phase control system performance via analytical simulation

A solar power satellite transmission system which incorporates automatic beam forming, steering, and phase control is discussed. The phase control concept centers around the notation of an active retrodirective phased array as a means of pointing the beam to the appropriate spot on Earth. The transmitting antenna (spacetenna) directs the high power beam so that it focuses on the ground-based receiving antenna (rectenna). A combination of analysis and computerized simulation was conducted to determine the far field performance of the reference distribution system, and the beam forming and microwave power generating systems.

Lindsey, W. C.↗

Solar energy system performance evaluation: Seasonal report for Colt Yosemite, Yosemite National Park, California

The system's operational performance from May 1979 through April 1980 is described. Solar energy satisfied 23 percent of the total performance load, which was significantly below the design value of 56 percent. A fossil savings of 80.89 million Btu's or 578 gallons of fuel oil is estimated. If uncontrolled losses could have been reduced to an inconsequential level, the system's efficiency would have been improved considerably.

Source record↗

Best Practices at the End of Photovoltaic System Performance Period

Responsible and cost-effective dissolution of photovoltaic (PV) system hardware at the end of the performance period has emerged as an important business and environmental consideration. Alternatives include extending the performance period and existing contracts for power purchase, lease, and utility interconnect; refurbishing the plant by correcting any deficiencies; repowering the plant with new PV modules and inverters; or decommissioning the plant and removing all the hardware from the site. Often key decisions are made very early in the project development and might require decommissioning by some certain date after the end of a power purchase agreement. To “abandon in place” is not an alternative acceptable to landowners and regulators, so any financial prospectus should include costs associated with decommissioning, even if those costs are deferred by extending operations, refurbishment, or repowering. Decommissioning costs are driven by regulations regarding the handling and disposal of waste, with reuse and recycling of PV modules and other components preferred as a way to reduce both costs and environmental impact. Each alternative is discussed with order-of-magnitude costs, and recommendations are provided considering site-specific details of that situation, such as estimated costs to refurbish or repower, projected revenue from continued operations, and tax considerations.

14 SOLAR ENERGY↗

Heating, Ventilating, and Air-Conditioning: Recent Advances in Diagnostics and Controls to Improve Air-Handling System Performance

The performance of air-handling systems in buildings needs to be improved. Many of the deficiencies result from myths and lore and a lack of understanding about the non-linear physical principles embedded in the associated technologies. By incorporating these principles, a few important efforts related to diagnostics and controls have already begun to solve some of the problems. This paper illustrates three novel solutions: one rapidly assesses duct leakage, the second configures ad hoc duct-static-pressure reset strategies, and the third identifies useful intermittent ventilation strategies. By highlighting these efforts, this paper seeks to stimulate new research and technology developments that could further improve air-handling systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Washington Clean Energy Fund: Energy Storage System Performance Test Plans and Data Requirements

This report documents the test plans, including detailed duty cycles, used in evaluating the technical performance of five energy storage systems (ESSs) sponsored by the Washington State Clean Energy Fund (CEF). These ESSs were installed at three participating utilities’ (Avista, Snohomish Public Utility District or SnoPUD, and Puget Sound Energy or PSE) designated sites. Under each test plan, a number of baseline and use case tests are defined. This report documents the test plan for each utility, including duty cycles, data and performance reporting requirements. Baseline tests defined in this report mainly focus on determining an initial or reference performance for each ESS, which may be compared with the performance at any later time to assess the state of health of the ESS. Parameter values of a given ESS obtained from baseline tests are applied for different modeling purposes and use case tests. The stored energy capacity test is the first test conducted in the baseline test program, which generates data to calculate round trip efficiency (RTE). The response time and ramp rate tests provide the time required for an ESS to change from zero to full charging/discharging rate and hence the ramp rate, which is important in understanding ESS performance for applications calling for fast response. Internal resistance testing of ESS cells is also conducted in conjunction with the response time and ramp rate tests. Finally, the baseline tests include frequency regulation (FR) and peak shaving (PS) tests based on real-world duty cycles. Upon completion of the baseline tests, use case tests are conducted at each of the storage sites with duty cycles developed to meet the site-specific criteria and conditions. The use cases are grouped according to their intended target benefits within the electric infrastructure topology (e.g., transmission versus distribution). Although an ESS may be located on the low-voltage side of a substation that provides power to a distribution feeder, a use case that addresses bulk power services could still be provided and would be grouped under the transmission or bulk-power benefits. Use cases for ESS applications deep into the distribution circuit would be categorized under the distribution system cases.

25 ENERGY STORAGE↗

Solar-energy-system performance evaluation: Honeywell OTS 44, Ocmulgee, Georgia

The operation and technical performance of the solar operational test site (OTS 44) are described, based on data collected between April, 1981 and August, 1981. The following topics are discussed: system description, performance assessment, operating energy, energy savings, system maintenance, and conclusions. The solar energy system at OTS 44 is a hydronic heating and cooling system consisting of 5040 square feet of liquid cooled flat plate collectors; a 4000 gallon thermal storage tank; one 25 ton capacity organic Rankine cycle engine assisted water chillers; a forced draft cooling tower; and associated piping, pumps, valves, controls and heat rejection equipment. The solar system has eight basic modes of operation and several combination modes for providing space conditioning and hot water to the building. Data monitored during the 4 months of the operational test period found that the solar system collected 285 MMBtu of thermal energy of the total incident solar energy of 1040 MMBtu and provided 210 MMBtu for cooling and 10 MMBtu for heating and hot water. The net electrical energy saving due to the solar system was approximately 2600 kWh(e), and fossil energy saving was about 20 million Btu (MMBtu).

Mathur, A. K.↗

Microwave system performance summary

The design of the microwave system for the solar power satellite is described. Design modifications recommended include changes in phase control to the power module level, a reduction in allowable amplitude jitter, the use of metal matrix waveguides, and sequences for startup/shutdown procedures. Investigations into reshaping the beam pattern to improve overall rectenna collection efficiency and improve sidelobe control are surveyed.

Arndt, G. D.↗