Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stress testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Modeling Validation of Mechanical and Thermal Borehole Breakouts From Polyaxial Laboratory Tests to Determine Maximum Horizontal in Situ Stress

To accurately assess rock behavior in the deep subsurface, it is necessary to measure the in situ stress directions and magnitudes. The current methods for measuring the in situ stress state in the deep subsurface primarily include hydraulic fracturing tests (i.e., the minimum horizontal stress) or occasionally observing existing compressive borehole breakouts (i.e., the maximum horizontal stress) that have occurred naturally from drilling. If there are no existing compressive breakouts in a borehole, the maximum horizontal in situ stress cannot be estimated with much confidence. In response to this data gap, a new thermal breakout technology is being developed that will provide a method for thermally inducing borehole breakouts and obtaining consistent measurements of the maximum horizontal stress magnitude. This thermal breakout technology involves heating the borehole and increasing the thermoelastic compressive stress in the rock until a breakout develops, which is directly correlated to the maximum horizontal stress magnitude. In support of developing the thermal breakout technology, polyaxial laboratory tests have been performed on small-scale boreholes within rock blocks where mechanically- and thermally-induced borehole breakouts have been created. Numerical models along with the principal of superposition were created and used to analyze the polyaxial laboratory tests to predict the maximum horizontal stress, given the same data that would be obtained in an actual subsurface borehole thermal breakout test. Multiple failure criteria were used to evaluate the best prediction of the breakout onset and maximum horizontal stress. The maximum horizontal stress predictions were compared to the actual maximum horizontal stress applied at breakout using acoustic events recorded from emission sensors in the polyaxial tests. The results showed consistent results that could be used to refine the modeling approach and failure criterion that are used to make the maximum horizontal stress predictions. This study provided insight and validation for the thermal breakout stress measurement concept.

Jones, Matt↗

Stress rupture of SiC/SiC composite tubes under high-temperature steam

SiC-fiber–reinforced SiC matrix composite cladding for light water reactor fuel elements must withstand high-temperature steam oxidation in a loss-of-coolant accident scenario (LOCA). Current composite designs include an outer monolithic SiC layer, in part, to increase steam oxidation resistance. However, it is not clear how such a structure would behave under high-temperature steam in the case when the monolithic layer cracks and carbon interphases and SiC fibers are exposed to the environment. To fill this knowledge gap, stress-rupture tests of prototypic SiC composite cladding at 1000°C under steam and inert environments were conducted. The applied stress was ~120 MPa, which was beyond the initial cracking stress. The failure lifetime under steam was 400–1300 s, while 75% of the composite specimens did not fail after 3 h of total exposure under inert gases. Microstructural observations suggest that steam oxidation activated slow crack growth in the fibers, which led to failure of the composite. The results from this study suggest that stress rupture in steam environments could be a limiting factor of the cladding under reactor LOCA conditions.

36 MATERIALS SCIENCE↗

Geomechanical Characterization of the Mount Simon Sandstone and Eau Claire Formation of Northern Illinois Basin

The purpose of this paper is to analyze publicly available geomechanical data from two carbon storage sites in the Illinois Basin: the Illinois Basin-Decatur Project (IBDP) in Macon County, IL and the FutureGen2.0 project in Morgan County, IL, cancelled before injection began. This study estimates the magnitudes and directions of the least compressive principal stress gradient using hydraulic fracture-based stress measurement tests, borehole breakouts, and sonic logs in the Eau Claire Formation (primary confining zone) and the Mount Simon Sandstone (targeted reservoir). The range of stresses expected in the underlying Precambrian basement is also investigated. The evaluation of the state of stress is carried out in a probabilistic manner using the State of Stress Analysis Tool (SOSAT) developed under the National Risk Assessment Partnership (NRAP) program. Finally, the paper also provides a discussion on distinctions between fracture initiation pressure, propagation pressure, and fracture closure pressure, given that hydraulic fracture testing results show a significant difference between these three values. The discussion also addresses why the fracture closure pressure should be preferred in injection pressure determinations, a critical point in geological carbon storage projects.

de Toledo Camargo, Julia↗

DE-FE0023919 Phase 5 Scientific/Technical Report

Phase 5 of the Deepwater Methane Hydrate Characterization and Scientific Assessment research project (DOE Award No. DE-FE0023919) occurred from Oct. 1, 2020 to Nov. 15, 2023. Throughout Phase 5, UT performed all aspects of project management and planning according to the award, project management plan, and statement of project objectives (Task 1). UT maintained and augmented the capability to transport, store, manipulate and analyze pressure cores (Task 13). UT’s hydrate core effective stress chamber can now run tests at effective stresses up to 20 MPa. A benchmark study was conducted and confirmed that the K0 permeameter accurately estimates geomechanical and petrophysical properties of geomaterials under uniaxial strain conditions. UT continued to analyze remaining UT-GOM2-1 pressure cores from GC955 (Task 10).

03 NATURAL GAS↗

Model 9975 O Ring Fixture LongTerm Leak Performance (FY2021 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 19 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 9.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 11.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 26 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2020 Status Report)

Leak testing experiments to monitor the aging performance of Viton GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. In addition, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 °F for 12 to 14 years or aging at 270 °F for 8.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 10 to 10.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determining the Reaction Kinetics and Thermodynamics of a Diels–Alder Network Using Dynamic Gel Criteria

We undertook a detailed rheological investigation to evaluate the kinetic parameters of the forward and reverse Diels–Alder (DA) reactions of a model network cross-linked using a furan prepolymer and a common aromatic bismaleimide. At high temperature where the Winter–Chambon’s criterion of frequency-independence was more applicable, a multiwave technique permitted van’t Hoff analysis and calculation of the reaction thermodynamic parameters, specifically the enthalpy and entropy of the reaction: ΔH° = –38.3 ± 5.2 kJ mol –1 and ΔS° = –94.3 ± 13.4 J mol –1 . At mild temperatures where the G'–G" crossover point is experimentally convenient to measure gelation, isothermal tests were used to obtain reasonable fDA kinetic parameters from Eyring analysis such as the apparent activation enthalpy and entropy of ΔH$^{‡}_{fDA}$ = 76.8 ± 6.9 kJ mol –1 and ΔS$^{‡}_{fDA}$= –82.8 ± 22.2 J mol –1 K –1 . Comparable rheokinetic methods include cross-linking density measurements and stress relaxation tests to calculate effective kinetics, whereas the critical gel conversion was consistently applied here. As a result, rate data are fitted with the Arrhenius equation for comparison purposes and the Eyring equation to demonstrate its broader utility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2022 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 10.4 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 12.5 years. This year, one GLT-S O-ring fixture failed after 12.4 years aging at 200 °F. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 25 mock-up PCV fixtures.

36 MATERIALS SCIENCE↗

FY2025 Status Report: Model 9975 O Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aged at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aged at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months while fixture #18 failed after 9 months at 350 °F. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F. There has been one GLT O-ring fixture which failed after 13.4 years of aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 16.9 years and remain in test. There are two GLT O-ring fixtures at 270 °F; one fixture has failed after 12.9 years while the other fixture remains in test after 12.5 years. All GLT-S O-ring fixtures aged at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 14.9 years, while one GLT-S O-ring fixture failed after 12.4 years at 200 °F. The leak testing data to date suggest the GLT and GLT-S O-rings aging in the K-Area Complex (KAC) storage at temperatures of 158 °F might maintain a leak-tight seal for up to 59 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 24 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strain shift measured from stress-controlled oscillatory shear: Evidence for a continuous yielding transition and new techniques to determine recovery rheology measures

Understanding the yielding of complex fluids is an important rheological challenge that affects our ability to engineer and process materials for a wide variety of applications. Common theoretical understandings of yield stress fluids follow the Oldroyd–Prager formalism in which the material behavior below the yield stress is treated as solidlike, and above the yield stress as liquidlike, with an instantaneous transition between the two states. This formalism was built on a quasi-static approach to the yield stress, while most applications, ranging from material processing to end user applications, involve a transient approach to yielding over a finite timescale. Using stress-controlled oscillatory shear experiments, we show that yield stress fluids flow below their yield stresses. This is quantified through measuring the strain shift, which is the value about which the strain oscillates during a stress-controlled test and is a function of only the unrecoverable strain. Measurements of the strain shift are, therefore, measurements of flow having taken place. These experimental results are compared to the Herschel–Bulkley form of the Saramito model, which utilizes the Oldroyd–Prager formalism, and the recently published Kamani–Donley–Rogers (KDR) model, in which one constitutive equation represents the entire range of material responses. Scaling relationships are derived, which allow us to show why yield stress fluids will flow across all stresses, above and below their yield stress. Finally, derivations are presented that show strain shift can be used to determine average metrics previously attainable only through recovery rheology, and these are experimentally verified.

Mechanics↗

Achieving High Strength and Creep Resistance in Inconel 740H Superalloy through Wire-Arc Additive Manufacturing and Thermodynamic-Guided Heat Treatment

Inconel 740H superalloy is commonly used in advanced ultra-supercritical power plants since it possesses excellent strength and creep resistance. This study investigates the microstructure and mechanical properties of Inconel 740H superalloy fabricated using wire-arc additive manufacturing. The as-printed microstructure consisted of columnar γ grains with the Laves phase and (Nb, Ti)C carbides as secondary phases. The anisotropy in grain structure increased from the bottom to the top regions, while the hardness was highest in the middle portion of the build. To guide the post-heat treatment design, thermodynamic and kinetic simulations were employed to predict the temperature and time. Complete recrystallization with the Laves phase dissolution occurred throughout the build after homogenization at 1200 °C for 2 h. The peak hardness was achieved after aging at 760 °C for 12 h with the M 23 C 6 carbides decorating the grain boundaries and γ’ precipitates in the grain interior. The yield strength (655 MPa) and ductility (29.5%) in the post-heat treated condition exceeded the design targets (620 MPa, 20%). Stress rupture tests at 750 °C showed that the high-temperature performance was at par with the wrought counterparts. The fracture mode after rupture was identified to be intergranular with the presence of grain boundary cavities along with grain boundary sliding.

36 MATERIALS SCIENCE↗

Uniaxial compressive creep tests by spark plasma sintering of 70% theoretical density α -uranium and U-10Zr

Metallic fuels hold numerous advantages over conventional uranium dioxide fuels and are a key component of several liquid metal-cooled advanced reactor concepts including sodium fast reactors. These fuels undergo rapid swelling during early burnup; consequently, they spend most of their reactor lifetime in a porous state. The presence of this porosity alters many of the mechanical properties of the fuel including creep impacting fuel deformation during axial swelling. This work investigates the creep behavior of the porous fuel using a spark plasma sintering technique. Creep tests were performed for the first time on porous α-phase uranium and uranium with 10 wt. % zirconium (U-10Zr) samples. The samples of α-phase uranium and U-10Zr were fabricated from depleted uranium by spark plasma sintering and subjected to uniaxial compressive creep testing. Calculated stress exponents were found to be 2.6±1.6 and 5.7±1.4 for α-U and U-10Zr, respectively, and calculated activation energies were found to be 61.6±1.1kJ/mol for α-U. The creep data were also used to evaluate existing porosity inclusive in creep models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recurrent neural network-based multiaxial plasticity model with regularization for physics-informed constraints

We report a recurrent neural network (RNN) based model is developed as a surrogate to predict nonlinear plastic response under multiaxial loading. The RNN-based model is trained and tested on stress versus strain curves generated using a numerical solution based on the classical radial return method. Besides simply learning the basic constitutive relationship, a novel approach is taken to enforce certain physical conditions. Specifically, regularization is employed to maintain non-negative plastic power density throughout the loading history thereby ensuring monotonically increasing plastic work and thermodynamic consistency. Enforcing physics in this manner permits coupling of the data-driven RNN approach with physics-based knowledge and laws. This has the effect of reducing the necessary amount of data and ensuring known physical laws are not violated. Since, once trained, the model need not perform the expensive task of solving nonlinear equations, its efficiency is orders of magnitude greater than its numerical counterpart. The RNN-based model has been trained on varied sets of data and the accuracy on test datasets validated. The developed model is general and robust and has widespread application such as in the simulation of metal forming, large scale plasticity, and part life prediction.

42 ENGINEERING↗

A probabilistic creep model incorporating test condition, initial damage, and material property uncertainty

Uncertainty is prevalent in the creep resistance of alloys, where at elevated temperature and low pressure, rupture can range across logarithmic decades. In this study, a probabilistic continuum-damage-mechanics (CDM)-based model is derived to capture the uncertainty of creep resistance. To meet this objective, creep data for alloy 304 Stainless Steel is gathered. A constitutive model, “Sinh”, is calibrated deterministically to determine the statistical variability of the material properties. Three sources of uncertainty are injected into the model: test condition (stress and temperature), initial damage, and material properties. Probabilistic simulations are carried out by (a) calibrating probability distribution functions (pdfs) for each source of uncertainty (b) randomly sampling the pdfs using Monte Carlo methods and (c) executing simulations to replicate the uncertain creep behavior. A sensitivity analysis is performed to evaluate the relative effect of each source of uncertainty. In full probabilistic simulations, the cumulative uncertainty of creep behavior is evaluated. The probabilistic model accurately predicts the creep deformation and rupture of the available experiments. The probabilistic model is validated for interpolation but lacks extrapolation ability. Several future works are proposed to further improve the model.

36 MATERIALS SCIENCE↗

Foam Fracturing Study for Stimulation Development of Enhanced Geothermal Systems

This is a final technical report for the project: Foam Fracturing Study for Stimulation Development of Enhanced Geothermal Systems (EGS). The goal is to demonstrate the feasibility of foam fracturing in EGS applications. The project, led by Oak Ridge National Laboratory (ORNL), was conducted in collaboration with Temple University. The report describes the research activities with Task 1 at ORNL: foam fracturing testing system development and experimental study on foam fracturing, and Task 2 at Temple University: foam testing and foam characterization. Main findings are: 1. A foam fracturing test system has been developed at ORNL, which can be used to perform foam fracturing under pressure up to 6,000 psi. The system monitors foam density during fracturing online and is capable of testing materials in both monotonic and cyclic (up to 50 Hz) injections. 2. Foam fracturing tests were carried out on Charcoal black granite specimens with a blind borehole to the middle length. Two diameters of blind borehole were tested; G2 series: 9.53 mm and G3 series: 4.76 mm. N2-in-water foam was used with AOS as a surfactant. 3. There was a hole-size effect on fracture initiation pressure. The effect is smaller in the case of foam, which was influenced by the high penetrability of gas in foam. Breakdown pressure showed a behavior just as that of fracture pressure; namely an increased value for small hole samples, while the effect in water fracture was more impressive than in foam fracture. 4. Water mass was reduced in foam fracturing within similar range of breakdown pressures. In G2 series, it was decreased from 10.44 g for water fracturing to 5.17 g, representing more than 50% water reduction. Therefore, there is the potential to reduce water use in EGS stimulation through foam fracturing. 5. Use of cyclic injection has the potential to reduce the breakdown pressure and seismicity in EGS application. Experiments using 4-s cycle period found that specimens can be fractured with a low number of cycles. The fatigue pressure was approximately 64 - 77% of monotonic breakdown pressure for water fracturing and 58 - 94% of the breakdown pressure for foam fracturing. 6. A foam stability testing system has been developed that can test foam at 220 Deg C to 2,000 psi. Tested components of candidate foams included two gases: N2 and CO2; 4 surfactants: AOS, SDS, NP-40 and CTAC; 5 stabilizing agents: guar, bentonite clay, borate salt, silica NPs, and GO. 7. N2 and AOS provided the most stable performance over the tested ranges. Furthermore, the AOS foam with stabilizing agents of guar and borate salt (crosslinker) offered the highest half-life of 20 minutes at 200 Deg C and 1,000 psi. 8. Arrhenius equation and modified power law have been demonstrated to fit well the half-time vs. temperature and pressure data, respectively. These relations can be useful to provide the suggestion for future foam stability study. This submission contains the supporting data developed during the project: 1) A final technical report 2) Granite fracturing data in monotonic and cyclic injections with water and N2 foam Foam performance data in various temperatures and pressures, including half-time, is submitted separately.

15 GEOTHERMAL ENERGY↗

Methods for In Situ Electroluminescence Imaging of Photovoltaic Modules Under Varying Environmental Conditions

Electroluminescence (EL) imaging is a powerful tool used to identify defects in photovoltaic solar cells. Typically, this type of characterization is performed in the dark using a current injection that equals short-circuit current measured at standard test conditions (STC). Restricting imaging to such a temperature range limits the information obtained about the module and cells. However, it is not trivial to develop a tool that would allow for EL imaging to be performed under a wider range of temperatures. Here we demonstrate an in situ EL imaging capability developed within an environmental chamber that allows for control of sample temperatures between –40 and 90 °C. Additionally, we demonstrate EL imaging of 4-cell mini-modules (MiMo) under front-side mechanical loading. A Raspberry Pi-connected camera with short-pass filter removed is used for EL imaging. The camera is low-cost with a small form-factor, appropriate for use in a harsh, enclosed environment. The camera is installed within a thermally isolating housing mounted within the environmental chamber. Three example cases are given for MiMos that exhibit various forms of degradation including solder fatigue and cell cracking. It is shown that by measuring at conditions above and below STC, different behaviors may be identified. In some cases, restricting characterization to STC may lead to a failure to detect damage existing in the sample.

14 SOLAR ENERGY↗

Screening Metal Halide Perovskite Solar Modules for Premature Field Failures

Developing metal halide perovskite (MHP) photovoltaic (PV) devices into reliable large-area solar modules could accelerate global solar energy deployment. Many MHP devices are susceptible to degradation under light and elevated temperature (LT). Published research on LT testing is limited at the module level, and LT testing has not yet been developed for qualification testing of commercial PV products. This report assesses whether results of LT testing at moderately elevated temperatures correlate with those of field-tested modules from the same batch. Six batches of samples from four manufacturers are assessed. It is shown that modules with a robust package that can maintain over 80% of their peak efficiency during LT testing at 55 °C for 100 h are more likely to retain over 80% of their peak efficiency during outdoor operation for 10 weeks. This finding is a step towards developing a validated test protocol that could be incorporated into a qualification standard for the commercialization of MHP PV technologies.

14 SOLAR ENERGY↗

An investigation into the effects of cyclic strain rate on the high cycle and very high cycle fatigue behaviors of wrought and additively manufactured Inconel 718

Additive Manufacturing (AM) has increasingly been used to fabricate parts in aerospace applications, which may require service lives beyond ten-million cycles due to the imposed high loading frequencies. Understanding the very high cycle fatigue (VHCF) behavior of these additive manufactured (AM) parts is an important step towards their design and qualification processes. This study focuses on the high cycle fatigue (HCF) and VHCF behaviors of both wrought and laser beam-powder bed fusion (LB-PBF) fabricated Inconel 718 in machined/polished surface condition, emphasizing on the influence of test frequency (i.e., cyclic strain rate). Uniaxial, fully-reversed force- and stress-controlled fatigue tests were conducted utilizing a servo-hydraulic and an ultrasonic test system operating at 5 Hz and 20 kHz, respectively, on wrought as well as LB-PBF vertically and diagonally built specimens. Fatigue cracks in the majority of the specimens were found to initiate from intra-granular slip bands near or at the surface, which gives rise to strong anisotropy in fatigue resistance in LB-PBF specimens due to the presence of columnar grains along the build directions. Longer fatigue lives were obtained at 20 kHz, which was ascribed to possibly lower-than-intended stresses applied in the ultrasonic tests. The corrected stress-life fatigue data at 20 kHz were found to converge to the one obtained from conventional testing at 5 Hz, implying no effect of cyclic strain rate on the fatigue behavior of Inconel 718 regardless of the fabrication process. The findings of this work confirm the use of ultrasonic fatigue testing to expedite generation of AM materials data to keep up with the current demand; however, the applied stress may need to be corrected.

36 MATERIALS SCIENCE↗