Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stress testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Cardiopulmonary data-acquisition system

Computerized system controls and monitors bicycle and treadmill cardiovascular stress tests. It acquires and reduces stress data and displays heart rate, blood pressure, workload, respiratory rate, exhaled-gas composition, and other variables. Data are printed on hard-copy terminal every 30 seconds for quick operator response to patient. Ergometer workload is controlled in real time according to experimental protocol. Collected data are stored directly on tape in analog form and on floppy disks in digital form for later processing.

Crosier, W. G.↗

Long life nickel electrodes for a nickel-hydrogen cell. I Initial performance

In order to develop a long life nickel electrode for a Ni/H2 cell, an investigation was begun to study the effects of sinter structure and active material loading level on the long life performance of nickel electrodes. This paper is a report on the initial performance of these electrodes as a part of an accelerated life test program. Seven different types of nickel plaques were made which included three levels of both their mechanical strength and median pore size. These plaques were impregnated with three levels of active material loading. The resultant electrodes were tested by a 200-cycle stress test which was conducted in flooded electrolyte, and also for initial performance in a Ni/H2 boiler plate cell. An interesting and unexpected observation was that an increased initial utilization of the active material was due more to its complete discharge to the lower average oxidation state than its increased charge acceptance in the charged state.

Lim, H. S.↗

Outdoor performance testing of thin-film devices

The Advanced Systems Research Group supports the photovoltaic advanced R&D (PV AR&D) project by providing outdoor (global) testing of PV cells, submodules, modules, and arrays. The group also provides in house engineering and analysis to identify and determine how technical issues such as cell/module/system adaptations, long term stability, reliability, economics, materials availability, safety, and environmental impacts affect the development and ultimate use of advanced PV thin film, innovative cell, and material technologies. A major thrust of the research effort is to develop and utilize instrumentation and procedures for monitoring and analyzing PV cells and submodules including outdoor performance and stability testing and life cycle accelerated stress testing. To accomplish the above, the solar energy research institute (SERI) outdoor PV test facility was established in 1982. The group has designed testing systems and analysis procedures for, and has tested, numerous amorphous silicon thin film submodules provided by SERI subcontractors and has performed long term outdoor stability tests on CdS/CuIr Se sub 2 and hydrogen passivated silicon solar cells. A significant contribution from this facility over the past year was the testing of large area amorphous silicon submodules.

Source record↗

Importance of Measuring SiC Fiber Diameter Prior to Conducting Fiber Stress Rupture / Creep Tests?

A very significant amount of SiC fiber creep / stress rupture data has been generated and reported in the past by various researchers. Due to the difficulty of measuring fiber diameter and the amount of time required to make accurate measurements, researchers have quite often used an accepted average diameter value (which is fiber type-dependent) when determining the load that will be applied to a fiber to generate a specific stress during testing. Of course, this approach has less of an effect on data scatter when the individual fibers in a tow have very similar diameters (minimal fiber-to-fiber variation in diameter). NASA GRC has begun using a laser fiber diameter measurement system, and we are considering eventually characterizing each SiC fiber prior to testing in creep/stressed oxidation. The laser system will be described in this presentation, as well as examples of fiber diameter data obtained in the past at AFRL. We are currently discussing the merits of using an average diameter in testing/data analysis vs. using a measured or "known" diameter. Information about our current intermediate temperature SiC fiber stress rupture testing will also be provided.

ceramic matrix composites↗

Transistor step stress program for JANTX2N4150

Reliability analysis of the transistor JANTX2N4150 manufactured by General Semiconductor and Transitron is reported. The discrete devices were subjected to power and temperature step stress tests and then to electrical tests after completing the power/temperature step stress point. Control sample units were maintained for verification of the electrical parametric testing. Results are presented.

Source record↗

Solar cell reliability testing

The progress and initial data on accelerated stress tests on small amorphous silicon test samples from several manufacturers are reported. The test samples include both single and tandem junction devices.

Lathrop, J.↗

Validation of NSSC-I software for the Hubble Space Telescope

This paper describes the simulation and test methods used to ensure that the NASA Standard Spacecraft Computer, Model 1, (NSSC-I) flight software for the Hubble Space Telescope properly carries out its requirements for control of scientific observations and for monitoring the health and safety of the payload. The hardware and software test environment is discussed. The different kinds of tests (unit, special real time, and stress tests) that are performed before the software is incorporated into the flight system are described, and the kinds of errors that each test category is best suited to find are listed. Finally, the limitations of the tests are discussed, and current plans for enhancing the test environment are outlined.

Foley, Glenn↗

Microstructural and Material Quality Effects on Rolling Contact Fatigue of Highly Elastic Intermetallic Ball Bearings

Rolling element bearings made from highly-elastic intermetallic materials (HIM)s, such as 60NiTi, are under development for applications that require superior corrosion and shock resistance. Compared to steel, intermetallics have been shown to have much lower rolling contact fatigue (RCF) stress capability in simplified 3-ball on rod (ASTM STP 771) fatigue tests. In the 3-ball tests, poor material quality and microstructural flaws negatively affect fatigue life but such relationships have not been established for full-scale 60NiTi bearings. In this paper, 3-ball-on-rod fatigue behavior of two quality grades of 60NiTi are compared to the fatigue life of full-scale 50mm bore ball bearings made from the same materials. 60NiTi RCF rods with material or microstructural flaws suffered from infant mortality failures at all tested stress levels while high quality 60NiTi rods exhibited no failures at lower stress levels. Similarly, tests of full-scale bearings made from flawed materials exhibited early surface fatigue and through crack type failures while bearings made from high quality material did not fail even in long-term tests. Though the full-scale bearing test data is yet preliminary, the results suggest that the simplified RCF test is a good qualitative predictor of bearing performance. These results provide guidance for materials development and to establish minimum quality levels required for successful bearing operation and life.

tribology↗

Microstructural and Material Quality Effects on Rolling Contact Fatigue of Highly Elastic Intermetallic NiTi Ball Bearings

Rolling element bearings made from highly-elastic intermetallic materials (HIM)s, such as 60NiTi, are under development for applications that require superior corrosion and shock resistance. Compared to steel, intermetallics have been shown to have much lower rolling contact fatigue (RCF) stress capability in simplified 3-ball on rod (ASTM STP 771) fatigue tests. In the 3-ball tests, poor material quality and microstructural flaws negatively affect fatigue life but such relationships have not been established for full-scale 60NiTi bearings. In this paper, 3-ball-on-rod fatigue behavior of two quality grades of 60NiTi are compared to the fatigue life of full-scale 50mm bore ball bearings made from the same materials. 60NiTi RCF rods with material or microstructural flaws suffered from infant mortality failures at all tested stress levels while high quality 60NiTi rods exhibited no failures at lower stress levels. Similarly, tests of full-scale bearings made from flawed materials exhibited early surface fatigue and through crack type failures while bearings made from high quality material did not fail even in long-term tests. Though the full-scale bearing test data is yet preliminary, the results suggest that the simplified RCF test is a good qualitative predictor of bearing performance. These results provide guidance for materials development and to establish minimum quality levels required for successful bearing operation and life.

metals↗

Product Reliability Trends, Derating Considerations and Failure Mechanisms with Scaled CMOS

As microelectronics is scaled into the deep sub-micron regime, space and aerospace users of advanced technology CMOS are reassessing how scaling effects impact long-term product reliability. The effects of electromigration (EM), time-dependent-dielectric-breakdown (TDDB) and hot carrier degradation (HCI and NBTI) wearout mechanisms on scaled technologies and product reliability are investigated, accelerated stress testing across several technology nodes is performed, and FA is conducted to confirm the failure mechanism(s).

CMOS integrated circuits↗

SIR Glass Test Vehicle Designed to Characterize Process Materials

The exposure to harsh environments can result in reliability issues on highly dense electronic packages and circuit assemblies. One area of concern is electrochemical failure mechanisms caused by electrolytic corrosion, electrochemical migration (dendrites), and leakage currents under humid conditions. These no-fault and no-trouble found failure points are challenging to detect and to perform process control during the assembly process. The focus of this research centers on metallizing glass surface insulation resistance test vehicles to characterize materials on electronic packages and components that exhibit the highest risk of failure due to material interactions and process residues. Glass test vehicles provide a visual representation of materials when they are exposed to moisture content in the air. Harsh environments can cause material interactions resulting in morphology changes, opening, and release of active components. A transparent test vehicle is highly functional for environmental stress testing under temperature, humidity, and bias. The designed experiment will evaluate the effects of material and process residues that can undergo changes in behavior during application, which leads to local failures.

Capen, Bill↗

Developments for Novel Module Architecture for Lower CapEx and Improved Recyclability for c-Si PV Modules

Photovoltaic (PV) energy production is currently increasing at a significant rate. A novel module architecture has been demonstrated that has potential for reducing manufacturing cost while improving module reliability and recycling for c-Si PV which utilizes an edge-seal. Referred to as Edge Sealed Module (ESM), this architecture eliminates the vacuum lamination process and cross-linked encapsulants on the interior of the module. Functioning prototypes of c-Si have been fabricated for stress testing in collaboration with National Renewable Energy Laboratories (NREL). These modules are being tested and compared to traditionally manufactured modules. Based on preliminary results, this module architecture is a potentially viable solution for improving the manufacturing cost and recyclability of PV modules while enhancing module performance.

costs↗

Relief Zones Enhance the Durability of Ultrathin Membranes in Electrochemical Conversion Devices

Premature failures in electrochemical conversion systems often result when membrane electrode assemblies (MEAs) use ultrathin (≤15 μm-thick) polymer electrolyte membranes, susceptible to mechanical degradation from stress concentrations arising from device-level integration. Herein, relief zones were developed to mitigate mechanical degradation by alleviating excess and nonuniform compression across active areas. Relief zones, created through ablation of carbonaceous diffusion media, enable seamless adaptation across MEA dimensions without need for hardware modifications. Demonstrated using fuel cells as a case study, accelerated stress tests revealed a 6-fold lifetime improvement (∼1500 h) compared to conventional edge-protected MEAs, decoupling device-level engineering effects from material limitations.

accelerated stress test↗

A Relief Zone Architecture for Enhanced Durability of Ultrathin Membranes in Electrochemical Conversion Devices

Premature cell failures in electrochemical conversion systems often result when membrane electrode assemblies (MEAs) are prepared with ultra-thin (= 15 micrometer-thick) polymer electrolyte membranes (PEMs). These high-performance PEMs are susceptible to mechanical degradation from stress concentrations arising from component and device-level integration. Herein, a relief zone was developed to mitigate mechanical degradation by alleviating excess and non-uniform compression across the active area. Relief zones, created through the ablation of carbonaceous diffusion material achieves a seamless adaptation across a range of MEA dimensions and electrochemical applications without need for costly hardware modifications. This concept was demonstrated using fuel cells as a case study. Accelerated stress test (AST) validations yielded a 6-fold improvement for MEAs prepared with relief zones (i.e., lifetime approximately 1500 h) compared to those fabricated using conventional edge-protection techniques, showcasing the utility of this technique in decoupling integration and device-level engineering effects from intrinsic material limitations for durable electrochemical devices.

14 SOLAR ENERGY↗

Observed changes in a-Si:H cell characteristics due to long term temperature stress

Determination of thermally induced degradation mechanisms affecting thin film amorphous silicon solar cells through the use of laboratory accelerated stress testing requires acquisition of specially constructed, individually addressable test cells and the development of highly repeatable instrumentation which is not influenced by short-term reversible optical effects. This paper illustrates these considerations by describing accelerated temperature stress procedures and test results for one type of a-Si:H cell. Observed electrical characteristic changes indicate that two types of stress induced mechanisms are operating - one of which is self limiting and can be observed at lower temperatures and one which continues to complete degradation. The self limiting mechanism can result in a dramatic improvement to cells having initially low Voc values.

Lathrop, Jay W.↗

Studying the Durability of Molybdenum Carbide Aerogel as an Electrocatalyst Support for Proton Exchange Membrane Fuel Cells

Carbon-supported platinum nanoparticles (Pt/C) are currently the state-of-the-art catalyst in proton exchange membrane fuel cells (PEMFCs). Unfortunately, the carbon support lacks the ability to stabilize the metal catalyst, as platinum tends to dissolve and agglomerate, significantly compromising the durability. Herein, we synthesized a ceramic material, molybdenum carbide aerogel (MCAG), and utilized it as a Pt support for PEMFCs, as an alternative for conventional carbon supports. N 2 adsorption and XRD analysis showed that the MCAG possesses a combination of high porosity and a well-defined ceramic crystalline structure. The Pt/MCAG system was studied for its electrocatalytic activity toward ORR in a half-cell and demonstrated satisfactory reaction kinetics and electrochemical active surface area, comparable to the commercial Pt/C. For durability examination, an accelerated stress test (AST) in a single cell was conducted with the Pt/MCAG catalyst at the cathode, following the U.S. DOE electrocatalyst AST protocol. Intermediate polarization curves and cyclic voltammograms were recorded over the course of the AST to monitor the aging process. The results indicated that the MCAG support exhibited superior durability in long-term fuel cell operation compared to a carbon support. The Pt/MCAG system demonstrated stable behavior during the progressive stages of the AST, retaining more than 50% of its initial performance by the end of the test, whereas carbon-supported Pt preserved only 30%.

25 ENERGY STORAGE↗

The influence of electrode crack dimensions on the durability of polymer electrolyte membrane fuel cells

Electrode cracks in polymer electrolyte membrane fuel cells (PEMFCs) are correlated with early onset failures. Here, in this work we investigate the influence of cracked gas diffusion electrodes (GDEs) on the durability of the membrane electrode assembly (MEA) using a combined chemical-mechanical accelerated stress test (AST). Electrode crack dimensions were systematically tuned using ink formulations and material selection strategies. A parameter to describe the crack width areal density (Φ CW ) was used to quantify the degree of discontinuity in the electrode surfaces. Open circuit voltage (OCV) transient analyses were used to benchmark and characterize the failure mechanisms in the MEAs as a function of the Φ CW . While smaller electrode-level cracks, on the order of microns, yielded a 28 % decrease in operating lifetime, larger cracks that propagated from a discontinuous, microporous layer (MPL) coating, decreased the operating lifetime by 56 %. This work emphasizes the need for material processing strategies that consider defect tolerances to limit membrane failures in PEMFCs.

08 HYDROGEN↗

The impact of hot-press conditions on the durability of polymer electrolyte membrane fuel cells

The proton exchange membrane integrity can be compromised during hot-press fabrication of membrane electrode assemblies (MEAs) causing premature cell failures during operation. In this work, infrared (IR) thermography was used as a diagnostic tool to spatially visualize hydrogen (H 2 ) crossover and identify process-induced-membrane irregularities (PIMs). These irregularities were identified as seed locations for MEA failures. Fine tuning of hot-press conditions was used to mitigate premature cell failures informed by accelerated stress testing (AST). The impact of PIMs on the initial performance, high-frequency resistances, open-circuit voltage, and H 2 crossover are reported. Nafion XL and 212 membranes, hot-pressed with a force of 16 kg/cm 2 and temperature of 120°C, were found to be consistently irregularity-free. Irregularity-free MEAs using Nafion 211, 212, and XL membranes demonstrated AST lifetime improvements of 58, 64 and 400%, respectively, compared to those fabricated with non-optimized conditions. In conclusion, this work highlights the importance of fabrication parameters on premature cell failures.

08 HYDROGEN↗