Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sterilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Sterile chamber operation with bio-isolator suit system

Development and characteristics of protective suit to permit man to operate in biologically sterile environment are described. Construction of tunnel, flexible seals, and cooling system are analyzed. Illustration of isolation suit is provided.

Hueschen, R. M.↗

Planning, evaluation and analytical studies in planetary quarantine and spacecraft sterilization

The technical and analytical support used to aid in developing requirements for planetary quarantine are presented. The investigation was divided into 8 work tasks which are presented in tabular form. Data include methods of sterilization, safety margins for quarantine, revision of contamination logs for Mars and Venus, and estimates of encapsulated and 'free' microbial burden.

Source record↗

A stochastic bioburden model for spacecraft sterilization.

Development of a stochastic model of the probability distribution for the random variable representing the number of microorganisms on a surface as a function of time. The first basic principle associated with bioburden estimation is that viable particles are removed from surfaces. The second notion important to the analysis is that microorganisms in environments and on surfaces occur in clumps. The last basic principle relating to bioburden modeling is that viable particles are deposited on a surface. The bioburden on a spacecraft is determined by the amount and kind of control exercised on the spacecraft assembly location, the shedding characteristics of the individuals in the vicinity of the spacecraft, its orientation, the geographical location in which the assembly takes place, and the steps in the assembly procedure. The model presented has many of the features which are desirable for its use in the spacecraft sterilization programs currently being planned by NASA.

Roark, A. L.↗

Heat-sterilized silver oxide-zinc cells: Cycle life studies

A JPL study was conducted to evaluate the cell design parameters that contribute to the cycle life of sealed, heat-sterilized silver oxide-zinc cells. Test cells having a rated capacity of 4.2 A-h were fabricated using zinc oxide electrodes prepared by the sintered Teflon process. Two separator variations were evaluated, one having acrylic acid and the other methacrylic acid grafted to irradiated polyethylene film. Significant results of this study include the following: (1) cycle life in excess of 300 cycles was attained; (2) a zinc oxide/silver stoichiometric ratio of 1.5 resulted in greater cycle life than a ratio of 1.1, and similar cycle life to cells having a ratio of 2; (3) cells having methacrylic acid grafted separators suffered somewhat less in capacity loss due to zinc electrode shape change than cells having acrylic acid type; (4) use of acrylic acid grafted separators was slightly superior to the methacrylic acid type in respect to silver penetration; and (5) the inclusion of a layer of potassium titanate paper adjacent to the zinc electrodes resulted in cells that achieved higher cycle life before any of the group failed than that reached by cells of any other construction.

Arms, J. T.↗

Advances in Sterilization and Decontamination: a Survey

Recent technical advances made in the field of sterilization and decontamination and their applicability to private and commercial interests are discussed. Government-sponsored programs by NASA produced the bulk of material presented in this survey. The summary of past and current research discussed is detailed to enhance an effective transfer of technology from NASA to potential users.

Source record↗

The effects of nutrient solution sterilization on the growth and yield of hydroponically grown lettuce

Two methods of removing bacteria from hydroponic nutrient solution [ultraviolet (UV) radiation and submicronic filter] were evaluated for efficiency and for their effects on lettuce (Lactuca sativa L.) production. Both methods were effective in removing bacteria; but, at high intensity, the ultraviolet sterilizer significantly inhibited the production of plants grown in the treated solution. Bacterial removal by lower intensity UV or a submicronic filter seemed to promote plant growth slightly, but showed no consistent, statistically significant effect.

NASA Discipline Number 61-10↗

Microwave powered sterile access port

A device and method for elimination of contamination during transfer of materials either into or from bioreactors, food containers, or other microbially vulnerable systems. Using microwave power, thermal sterilizations of mating fixtures are achieved simply, reliably, and quickly by the volatilization of small quantities of water to produce superheated steam which contacts all exposed surfaces.

Sauer, Richard L.↗

Method of sterilization using ozone

Methods of using ozone have been developed which sterilize instruments and medical wastes, oxidize, organics found in wastewater, clean laundry, break down contaminants in soil into a form more readily digested by microbes, kill microorganisms present in food products, and destroy toxins present in food products. The preferred methods for killing microorganism and destroying toxins use pressurized, humidified, and concentrated ozone produced by an electrochemical cell.

Murphy, Oliver J.↗

Sealing and External Sterilization of a Sample Container

A method of (1) sealing a sample of material acquired in a possibly b iologically contaminated ("dirty") environment into a hermetic conta iner, (2) sterilizing the outer surface of the container, then (3) d elivering the sealed container to a clean environment has been propos ed. The method now proposed was originally intended to be used to ret urn samples from Mars to Earth, but could also be used on Earth to t ransport material samples acquired in environments that contain biol ogical hazards and/or, in some cases, chemical hazards.

Bar-Cohen, Yoseph↗

Electroporation System for Sterilizing Water

A prototype of an electroporation system for sterilizing wastewater or drinking water has been developed. In electroporation, applied electric fields cause transient and/or permanent changes in the porosities of living cells. Electroporation at lower field strengths can be exploited to increase the efficiency of chemical disinfection (as in chlorination). Electroporation at higher field strengths is capable of inactivating and even killing bacteria and other pathogens, without use of chemicals. Hence, electroporation is at least a partial alternative to chlorination. The transient changes that occur in micro-organisms at lower electric-field strengths include significantly increased uptake of ions and molecules. Such increased uptake makes it possible to achieve disinfection at lower doses of chemicals (e.g., chlorine or ozone) than would otherwise be needed. Lower doses translate to lower costs and reduced concentrations of such carcinogenic chemical byproducts as trichloromethane. Higher electric fields cause cell membranes to lose semipermeability and thereby become unable to function as selective osmotic barriers between the cells and the environment. This loss of function is the cause of the cell death at higher electric-field intensities. Experimental evidence does not indicate cell lysis but, rather, combined leaking of cell proteins out of the cells as well as invasion of foreign chemical compounds into the cells. The concept of electroporation is not new: it has been applied in molecular biology and genetic engineering for decades. However, the laboratory-scale electroporators used heretofore have been built around small (400-microliter) cuvettes, partly because the smallness facilitates the generation of electric fields of sufficient magnitude to cause electroporation. Moreover, most laboratory- scale electroporators have been designed for testing static water. In contrast, the treatment cell in the present system is much larger and features a flow-through geometry, such that electric fields strong enough to effect 99.9- percent disinfection can be applied to water flowing in a pipe.

Schlager, Kenneth J.↗

Ionizing Radiation from Ex Vivo Sterilization Diminishes Collagen Integrity and Vertebral Body Mechanics

Clinical exposure to ionizing radiation could put cancer radiotherapy or bone allograft patients at an increased risk of fracture. In these applications, ionizing radiation levels can range from accumulative 50 Gy for radiotherapy cancer treatment, to acute 35,000 Gy for allograft sterilization. Ionizing radiation has been shown to decrease bon equality through reduced strength and post-yield properties and degrade collagen integrity through either increased crosslinks (advanced glycation end products, AGEs)or fragmentation. It is unclear which collagen structural change accounts for reduced strength. The dose-dependent effect of ionizing radiation on mechanical and biochemical properties of whole bones are not well understood, particularly for ex vivo doses ranging from 50 to 35,000 Gy.

Radiation↗