SEARCH · Engineering Papers
Results for “steam flow”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Sorbent Based Post-Combustion CO 2 Slipstream Testing
TDA Research, Inc. has developed a low-cost sorbent (alkalized alumina) based technology for post-combustion CO 2 capture. The sorbent runs in an isothermal process for adsorption and regeneration. Neither temperature swing nor pressure swing is needed. TDA designed a system which operated 10 fixed beds to simulate a moving bed process. The flow pattern was optimized to minimize the steam usage for regeneration. An excellent sorbent (Batch 1) was also developed with collaboration with our partner. The sorbent degraded after long term operation. We developed a reprocessing procedure, which can be conducted in situ, to restore the sorbent capture capacity as the fresh sorbent after running for about 1250 hours. The reprocessing extended the sorbent longevity significantly. TDA designed a pilot unit (40’ x 32’ x 11.5’), processing flue gas equivalent to 0.5 MW of power generation. It had 10 beds and each bed could hold 1.75 m 3 of sorbent. We worked with Springs Fabrication, Inc. to complete the construction of the pilot unit. It was then shipped and installed at NCCC. The pilot unit was kept running in 24-hour mode when the flue gas and steam were available. It could run automatically without operator on site. Parametric and long-term (2 months) tests were carried out successfully. The results showed that TDA’s process can achieve 90% capture and 95% CO 2 purity for both coal and NG flue gases. For coal flue gas, the system reached performance target when processing up to 0.62 MW flue gas, 24% higher than the design capacity. Thus, capital cost could be saved on the reactors and sorbent. The strip air flow was designed to be 0.25 of that of the flue gas. The test data showed the strip/flue ratio can be reduced to as little as 0.18, which saves the power consumption for the strip air blower. The pressure drop was found to be lower than what the empirical equation calculated. The sorbent still had 91.7% of original capacity after 3-month test. With the data from the pilot test, we updated the TEA. For a 550-MW e supercritical coal fired power plant with CO 2 capture, the capture cost for TDA’s process is $34.9/tonne CO 2 captured, which meets DOE’s goal of $40/tonne and is 17.1% less than the DOE baseline Case 12. Therefore, TDA’s process has a good potential for commercialization.
3D CFD ELECTROCHEMICAL AND HEAT TRANSFER MODEL OF AN INTERNALLY MANIFOLDED SOLID OXIDE ELECTROLYSIS CELL
A three-dimensional computational fluid dynamics (CFD) electrochemical model has been created to model high-temperature electrolysis cell performance and steam electrolysis in an internally manifolded planar solid oxide electrolysis cell (SOEC) stack. This design is being evaluated at the Idaho National Laboratory for hydrogen production from nuclear power and process heat. Mass, momentum, energy, and species conservation and transport are provided via the core features of the commercial CFD code FLUENT. A solid-oxide fuel cell (SOFC) model adds the electrochemical reactions and loss mechanisms and computation of the electric field throughout the cell. The FLUENT SOFC user-defined subroutine was modified for this work to allow for operation in the SOEC mode. Model results provide detailed profiles of temperature, operating potential, steam-electrode gas composition, oxygen-electrode gas composition, current density and hydrogen production over a range of stack operating conditions. Single-cell and five-cell results will be presented. Flow distribution through both models is discussed. Flow enters from the bottom, distributes through the inlet plenum, flows across the cells, gathers in the outlet plenum and flows downward making an upside-down ''U'' shaped flow pattern. Flow and concentration variations exist downstream of the inlet holes. Predicted mean outlet hydrogen and steam concentrations vary linearly with current density, as expected. Effects of variations in operating temperature, gas flow rate, oxygen-electrode and steam-electrode current density, and contact resistance from the base case are presented. Contour plots of local electrolyte temperature, current density, and Nernst potential indicate the effects of heat transfer, reaction cooling/heating, and change in local gas composition. Results are discussed for using this design in the electrolysis mode. Discussion of thermal neutral voltage, enthalpy of reaction, hydrogen production, cell thermal efficiency, cell electrical efficiency, and Gibbs free energy are discussed and reported herein.
TRACE Analysis of Loss of Flow for the APR1400
The APR1400 is a pressurized water reactor (PWR). The APR1400 nuclear steam supply system consists of a reactor pressure vessel (RPV), which contains the reactor core, and two primary reactor coolant system loops connected in parallel to the RPV. Each coolant loop consists of a hot leg (HL), a u-tube steam generator (SG), two reactor coolant pumps (RCPs) and two cold legs (CLs). A pressurizer is connected to the hot leg on one of the coolant loops. During normal operation, the RCPs circulate high pressure water through the reactor core to remove the heat. The heated water exits the RPV and passes through the hot legs into the steam generator tubes. Heat is transferred through the walls of the steam generator tubes into a lower pressure secondary coolant system. Cooled primary system water from the steam generators is returned through the RCPs and cold legs to the RPV. The RCPs operate at constant speed; the primary coolant system is designed to provide a prescribed rate of coolant flow through the reactor core. The APR1400 SG secondary coolant system pressure is controlled through modulation of valves in the steam lines to maintain a prescribed turbine inlet pressure. The SG secondary coolant inventory is controlled by using a feedwater control system to maintain a prescribed liquid level in the steam generator downcomer. This water inventory level is sufficient to cover the outer surfaces of the steam generator tubes while preventing overfill that would cause liquid to pass from the steam generators through the steam lines into the turbine system. In the current work, the Nuclear Regulatory Commission's reactor systems analysis code, TRACE?2 was used to perform an analysis of a loss of flow anticipated operational occurrence (AOO). The loss of flow is initiated by a loss of off-site power (LOOP), resulting in a trip of the RCPs. The regulatory purpose of the current work is to confirm safety analyses documented in the APR1400 Design Control Document (DCD)
Hybridizing Solar Heat with a Geothermal Binary Power Plant Using a Solar Steam Topping Turbine
Solar-thermal hybridization is a way to boost power generation of geothermal power plants, especially when the geothermal resource cannot supply the design flow or temperature. A new process using a high-pressure steam topping turbine can almost double the conversion rate of solar energy to power compared to the common practice of solar brine heating, and thus improve economic viability. This study looked at one such plant. Output from a geo-solar hybrid is typically increased both from the additional solar energy and from restoring turbine design-point efficiency. In this new process, a third effect occurs: the addition of a solar topping cycle increases the geothermal energy extracted from the brine. Process flow diagrams, off-design results, and economic results are presented. Three representative geothermal locations in the U.S. are evaluated, as are the effects of thermal storage, solar field sizing, and tax incentives.
Process intensification approach to enhancing heat and mass transfer: Radio frequency (RF) assisted drying of paper and board
Conventional multi-cylinder drying of paper and board typically relies on both conductive drying from steam-heated cylinders and convective drying, where heated air flows over the paper web surface. Conduction primarily contributes to heat transfer, while convection is the main driver of mass transfer. However, conventional drying systems are heavily dependent on steam, usually powered by fossil fuels, and are often energy-inefficient with high levels of waste. Additionally, these surface-driven processes result in a lower percentage of energy absorption compared to the energy supplied, leading to significant energy losses. To improve this long-standing process, an experimental system was developed to investigate a process intensification approach involving the integration of Radio Frequency (RF) heating, a volumetric electromagnetic technology, alongside traditional conduction and convection drying methods. This study also emphasizes the use of sensors to continuously monitor key parameters such as moisture content, supply system temperatures, sample temperatures, air flows, and drying rates in real-time. The effect of RF as an auxiliary energy source in localized environments at varying moisture levels was explored to optimize industrial drying systems, quantify potential improvements, and provide insights for future studies. Experimental results from trials combining RF with convection and with the base case alternating conduction-convection drying processes are presented. It is shown that RF is a viable process intensification approach for paper drying improving the drying rate and energy intensity at higher moisture contents. These findings offer valuable insights for process intensification and contribute to the process development, modeling, and simulation of advanced paper drying techniques.
Visualization of flow interaction in a channel flow produced by a pair of helically coiled rods
Helically coiled tubes have been considered in the design of steam generators or heat exchangers of next generation nuclear power plants. Its compactness, efficiency, and the capability to absorb thermal expansion are desirable for nuclear reactor designs. However, the complex flow generated by the helically coiled geometry can result in flow induced vibration (FIV). In order to predict the FIV, there have been efforts using Computational Fluid dynamics (CFD)4, 5 to be coupled with multi-mechanics simulations. However, it is required to validate CFD to have confidence in capturing the flow structure characteristics of the transient complex flow behavior and fluctuation. In the present study, a simplified helically coiled steam generator (HCSG) design experiment was built acquiring data for CFD validation purpose. It is not perfect representation of the multiple rods, however, the current test facility produced transient data of the flow interaction between the rods and flow fluctuations near the rods. Particle Image Velocimetry (PIV) was applied to visualize the turbulent flow in a channel with slant rods. The two dimensional turbulent flow fields were analyzed. The velocity components were defined as below. u = U + u' (1) v = V + v' (2) where u is the lateral velocity on x-axis, v is the vertical velocity on y-axis, U and V are the mean velocities, and u' and v' are the fluctuation. Reynolds number, Re, was calculated using the rod diameter, d = 15.9 mm, and the upstream approach velocity, V{sub 0} = 0.5 m/s. Re = V{sub 0} d/η (3) where η is the kinematic viscosity of water. The experiment was conducted at Re ≅ 9,000 considering the currently reasonable computing power. Flow visualization in a flow channel produced by helically coiled rods was performed using PIV. The mean velocity field and streamlines were presented in this paper. The vortical flow structures in the cavity between rods were observed. Because of the asymmetric geometry, the flow profile was skewed. Additional measurements and transient analysis will be conducted to produce benchmark data for FIV study using CFD. Also, a test facility with a 5-rod heat exchanger design is operating to produce more data as a further work.
Coupled simulation of the reactor core using CUPID/MASTER
The CUPID is a component-scale thermal hydraulics code which is aimed for the analysis of transient two-phase flows in nuclear reactor components such as the reactor vessel, steam generator, containment. This code adopts a three-dimensional, transient, two-phase and three-field model, and includes physical models and correlations of the interfacial mass, momentum, and energy transfer for the closure. In the present paper, a multi-physics simulation was performed by coupling CUPID with a three dimensional neutron kinetics code, MASTER. MASTER is merged into CUPID as a dynamic link library (DLL). The APR1400 reactor core during a control rod drop/ejection accident was simulated as an example by adopting a porous media approach to employ a fuel assembly. The following sections present the numerical modeling for the reactor core, coupling of the kinetics code, and the simulation results. And also, a preliminary study for multi-scale simulation between CUPID and system-scaled thermal hydraulics code, MARS will be introduced as well. (authors)
Characterization of activated carbon prepared from chicken waste and coal
Activated carbons (ACs) were prepared from chicken waste (CW) and coal (E-coal) blended at the ratios of 100:0, 80:20, 50:50, 20:80, and 0:100. The process included carbonization in flowing gaseous nitrogen (300 mL min{sup -1}) at ca. 430{sup o}C for 60 min and successive steam activation (0.1 mL min{sup -1} water injection with a flow of N{sub 2} at 100 mL min{sup -1}) at 650{sup o}C for 30 min. Chicken waste is low in sulfur content but is high in volatile matter (about 55 wt %), and ACs with higher specific surface area were more successfully obtained by mixing with coal. The specific surface area of the CW/Coal blend AC can be estimated by SSA{sub BET} = -65.8x{sup 2} + 158x + 168, where SSA{sub BET} is the specific surface area in m{sup 2} g{sup -1} as determined by the BET method using CO{sub 2} as the adsorbent, where x is the coal fraction by weight in the CW/coal blend ranging from 0.0 to 1.0 (e.g., x = 0.0 signifies the blend contains no coal and x = 1.0 signifies the blend consists of 100% coal). 26 refs., 7 figs., 3 tabs.
Computational Analyses in Support of Sub-scale Diffuser Testing for the A-3 Facility: Unsteady Analyses and Risk Assessment - Part 2
Simulation technology can play an important role in rocket engine test facility design and development by assessing risks, providing analysis of dynamic pressure and thermal loads, identifying failure modes and predicting anomalous behavior of critical systems. This is especially true for facilities such as the proposed A-3 facility at NASA SSC because of a challenging operating envelope linked to variable throttle conditions at relatively low chamber pressures. Design Support of the feasibility of operating conditions and procedures is critical in such cases due to the possibility of startup/shutdown transients, moving shock structures, unsteady shock-boundary layer interactions and engine and diffuser unstart modes that can result in catastrophic failure. Analyses of such systems is difficult due to resolution requirements needed to accurately capture moving shock structures, shock-boundary layer interactions, two-phase flow regimes and engine unstart modes. In a companion paper, we will demonstrate with the use of CFD, steady analyses advanced capability to evaluate supersonic diffuser and steam ejector performance in the sub-scale A-3 facility. In this paper we will address transient issues with the operation of the facility especially at startup and shutdown, and assess risks related to afterburning due to the interaction of a fuel rich plume with oxygen that is a by-product of the steam ejectors. The primary areas that will be addressed in this paper are: (1) analyses of unstart modes due to flow transients especially during startup/ignition, (2) engine safety during the shutdown process (3) interaction of steam ejectors with the primary plume i.e. flow transients as well as probability of afterburning. In this abstract we discuss unsteady analyses of the engine shutdown process. However, the final paper will include analyses of a staged startup, drawdown of the engine test cell pressure, and risk assessment of potential afterburning in the facility. Unsteady simulations have been carried out to study the engine shutdown process in the facility and understand the physics behind the interactions between the steam ejectors, the test cell and the supersonic diffuser. As a first approximation, to understand the dominant unsteady mechanisms in the engine test cell and the supersonic diffuser, the turning duct in the facility was removed. As the engine loses power a rarefaction wave travels downstream that disrupts the shock cell structure in the supersonic diffuser. Flow from the test cell is seen to expand into the supersonic diffuser section and re-pressurizes the area around the nozzle along with a upstream traveling compression wave that emanates from near the first stage ejectors. Flow from the first stage ejector expands to the center of the duct and a new shock train is formed between the first and second stage ejectors. Both stage ejectors keep the facility pressurized and prevent any large amplitude pressure fluctuations from affecting the engine nozzle. The resultant pressure loads the nozzle experiences in the shutdown process are small.
Improved cell for water-vapor electrolysis
Continuous-flow electrolytic cells decompose water vapor in steam and room air into hydrogen and oxygen. Sintered iridium oxide catalytic anode coating yields dissociation rates hundredfold greater than those obtained using platinum black. Cell consists of two mirror-image cells, with dual cathode sandwiched between two anodes. Gas traverses serpentine channels within cell and is dissociated at anode. Oxygen mingles with gas stream, while hydrogen migrates through porous matrix and is liberated as gas at cathode.
A STRONGLY COUPLED REACTOR CORE ISOLATION COOLING SYSTEM MODEL FOR EXTENDED STATION BLACK-OUT ANALYSES
The reactor core isolation cooling (RCIC) system in a boiling water reactor (BWR) provides makeup cooling water to the reactor pressure vessel (RPV) when the main steam lines are isolated and the normal supply of water to the reactor vessel is lost. The RCIC system operates independently of AC power, service air, or external cooling water systems. The only required external energy source is from the battery to maintain the logic circuits to control the opening and/or closure of valves in the RCIC systems in order to control the RPV water level by shutting down the RCIC pump to avoid overfilling the RPV and flooding the steam line to the RCIC turbine. It is generally considered in almost all the existing station black-out accidents (SBO) analyses that loss of the DC power would result in overfilling the steam line and allowing liquid water to flow into the RCIC turbine, where it is assumed that the turbine would then be disabled. This behavior, however, was not observed in the Fukushima Daiichi accidents, where the Unit 2 RCIC functioned without DC power for nearly three days. Therefore, more detailed mechanistic models for RCIC system components are needed to understand the extended SBO for BWRs. As part of the effort to develop the next generation reactor system safety analysis code RELAP-7, we have developed a strongly coupled RCIC system model, which consists of a turbine model, a pump model, a check valve model, a wet well model, and their coupling models. Unlike the traditional SBO simulations where mass flow rates are typically given in the input file through time dependent functions, the real mass flow rates through the turbine and the pump loops in our model are dynamically calculated according to conservation laws and turbine/pump operation curves. A simplified SBO demonstration RELAP-7 model with this RCIC model has been successfully developed. The demonstration model includes the major components for the primary system of a BWR, as well as the safety system components such as the safety relief valve (SRV), the RCIC system, the wet well, and the dry well. The results show reasonable system behaviors while exhibiting rich dynamics such as variable flow rates through RCIC turbine and pump during the SBO transient. The model has the potential to resolve the Fukushima RCIC mystery after adding the off-design two-phase turbine operation model and other additional improvements.
Preconceptual Designs of Coupled Power Delivery between a 4-Loop PWR and 100-500 MWe HTSE Plants
This study develops a preconceptual design for the integration between a large-scale high-temperature electrolysis facility and a NPP. Two hydrogen facility sizes are considered: 100 MWnom and 500 MWnom. Both steam supply designs use cold reheat steam extraction as a heat source. A reboiler inside the protected area of the power plant transfers steam heat to the demineralized water supply for the hydrogen plant. After the heat transfer, the extracted steam condenses and returns to the condenser while the process steam routes out of the protected area to the electrolyzers. Electrical power is tapped off from the high voltage side of the GSU transformer, where it is then transported via a 345-kV transmission line to the hydrogen facility. Circuit breakers and disconnects are located at both ends of the transmission line. Step down transformers and miscellaneous switchgear/buses are located at the end of the transmission line inside the HTEF boundary. Control capabilities for the steam interfacing equipment and electrical dispatch are accessible from the Main Control Room, and protective relays for the transmission line are located inside the Relay Room. Computer modeling was performed for the thermal and electrical designs. PEPSE analysis provided the steady-state parameters for thermal extraction from the turbine cycle. These parameters were used to inform transients and size equipment in combination with Applied Flow Technology (AFT) Arrow and AFT Fathom modeling for steam and water piping, respectively. Electrical transients were analyzed using PSCAD. An ETAP model was used to evaluate power flow and short circuit, which enabled the sizing of transformers and protective equipment. A cost estimate was developed for both integration designs when considering plant separation distances of 250 m and 500 m. From these estimates, the modifications for thermal and electrical interfacing of a first-of-a-kind nuclear-integrated hydrogen facility are anticipated to cost between $60–250/kWnom., where the subscript “nom” refers to the nominal size of the hydrogen plant. On a thermal power basis, the thermal power has a cost of approximately $8/MWth for a 500 MWnom high temperature electrolysis plant located 500 m distant from the NPP. That value decreases to approximately $7.5/MWth for a 250 m separation distance between the hydrogen plant and the NPP. This value is lower than previous estimates of the cost of heat extracted from NPPs primarily because in this work the steam is extracted from cold reheat instead of the main steam line, which reduces the cost of the dispatched steam by approximately $3.5/MWth. Nuclear steam extraction can provide a profit avenue for many plants and is not restricted to hydrogen production. Ammonia production, oil refining, and paper production, among other industrial processes all require thermal energy, which can be provided by NPPs. Future work should look further at the details of thermal extraction for a variety of use cases. This can include increased levels of extraction and multiple simultaneous users. Additionally, site-specific studies should be performed to develop industry experience and improve cost accuracy.
Intracore Natural Circulation Study in the High Temperature Test Facility
The development of the Modular High-Temperature Gas-Cooled Reactor is a significant milestone in advanced nuclear reactor technology. One of the concerns for the reactor’s safe operation is the effects of a loss-of-flow accident (LOFA) where the coolant circulators are tripped, and forced coolant flow through the core is lost. Depending on the steam generator placement, loop or intracore natural circulation develops to help transfer heat from the core to the reactor cavity, cooling system. This paper investigates the fundamental physical phenomena associated with intracore coolant natural circulation flow in a one-sixth Computational Fluid Dynamics (CFD) model of the Oregon State University High Temperature Test Facility (OSU HTTF) following a loss-of-flow accident transient. This study employs conjugate heat transfer and steady-state flow along with an SST k-ω turbulence model to characterize the phenomenon of core channel-to-channel natural convection. Previous studies have revealed the importance of complex flow distribution in the inlet and outlet plenums with the potential to generate hot coolant jets. For this reason, complete upper and lower plenum volumes are included in the analyzed computational domain. CFD results also include parametric studies performed for a mesh sensitivity analysis, generated using the STAR-CCM+ software. The resulting channel axial velocities and flow directions support the test facility scaling analysis and similarity group distortions calculation.
Investigation of Technologies to Improve Condenser Heat Transfer and Performance in a Relevant Coal-Fired Power Plant
Improvements in thermal power-generating plant performance is correlated directly to societal benefits including lower cost of reduced fuel consumption, resulting in lower cost of electricity for the consumer and reduced carbon emissions to the atmosphere. Warm steam exhausted from low-pressure steam turbines is condensed to liquid water on the exterior of thin-walled metal condenser tubes with cooling water passing through the tube interior. The condensation of steam creates a vacuum that supports turbine rotation and the concurrent generation of electricity. This vacuum is optimized when heat transfer across the wall of condenser tube is maximized. Common hindrances to heat transfer include foulants in cooling water that may form and adhere to the interior of condenser tubes, including mineral scale, microbiological films, and particulate deposition. Flowing cooling water may also include a laminar layer at the interior metal surfaces that travels more slowly than bulk water flow, serving to impede heat transfer. On the tube exterior, condensing steam forms an insulating layer of water that flows down the tube and reduces the effectiveness of cooling. Both the interior and exterior barriers to optimal heat transfer may be alleviated to some extent by surface treatments. On the tube interior, hydrophobic coatings may be applied that can reduced the adherence of foulants and of the laminar flow layer to the tube surface. On the tube exterior, hydrophobic coatings or mechanical treatments can be applied that may result in the termination of droplet growth and the departure of droplets from the surface rather than coalescence into a continuous layer of flowing water. Fourteen surface treatments were applied to condenser tubes in this study, including eight interior coatings and six exterior treatments, five of which were coatings and one a microstructural texture. Heat transfer measurement equipment simulating conditions in the condenser of an operating power plant was used to determine heat transfer coefficients by measuring sufficient flow, temperature, water chemistry and other data. Several of the tubes with interior surface treatments showed improvement in heat transfer coefficients compared with a plain (uncoated) tube, and several of the tubes with exterior surface treatments also showed enhanced heat transfer coefficients.
Solar-Driven Steam Topping Cycle for a Binary Geothermal Power Plant
Solar-thermal hybridization is a way to boost power generation of geothermal power plants, especially when the geothermal resource cannot supply the design flow or temperature. A new process using a high-pressure steam topping turbine can almost double the conversion rate of solar energy to power compared to the common practice of solar brine heating, and thus improve economic viability.
Simulation Results of a Thermal Power Dispatch System from a Generic Pressurized Water Reactor in Normal and Abnormal Operating Conditions
Amid economic pressures in the U.S. electricity market, nuclear utilities are exploring new revenue streams, including hydrogen production. A generic pressurized water reactor simulator was modified to incorporate a novel design for a TPD system coupled to a hydrogen production plant. Standard malfunctions were included in the simulation design, including steam line breaks at various system locations and flow interruptions in the hydrogen plant due to multiple faults, reflecting anticipated operational challenges. It is imperative that the TPD system operation has a minimal effect on the reactor power, primary coolant system, and turbine system operation and performance. Due to the specific design and application of this TPD system, with the proposed turbine control system changes, the overall impact on the existing plant systems is low. Normal TPD operating scenarios resulted in minor effects on the existing plant systems: reactor power changes by at most 0.2%, and gross generator output changes by 20.5 MWe from 100 MWt of TPD. The most severe malfunction analyzed in this work is a full TPD steam line break downstream of the extraction location, which results in an increase in reactor power of about 0.5%. The gross generator output decreases by 36 MWe, a total decrease of 60 MWe from the full power steady state (FPSS) condition. These results indicate that an industrial hydrogen production plant could be coupled thermally to a nuclear power plant with limited effects on the existing system operation and safety.
A kinetic theory treatment of heat transfer in plane Poiseuille flow with uniform pressure
Plane compressible Poiseuille flow with uniform pressure (Couette flow with stationary boundaries) is revisited where the Lees two-steam method with the Enskog equation of change is applied. Single particle velocity distribution functions are chosen, which preserve the essential physical features of this flow with arbitrary but uniform plate temperatures and gas pressure. Lower moments are shown to lead to expressions for the parameter functions, molecular number densities, and temperatures which are entirely in agreement with those obtained in the analysis of Lees for compressible plane Couette flow in the limit of low Mach number and vanishing mean gas velocity. Important simplifications result, which are helpful in gaining insight into the power of kinetic theory in fluid mechanics. The temperature distribution, heat flux, as well as density, are completely determined for the whole range of Knudson numbers from free molecular flow to the continuum regime, when the pressure level is specified.