Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “statistical distributions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Summary Statistics for TA_SH02_130820: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_SH02_130820, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MT03_130730: Micro-CT Data Acquired at LLNL, Specimen 3 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MT03_130730, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_SH01_130819: Micro-CT Data Acquired at LLNL, Specimen 1 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_SH01_130819, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MT01_130725: Micro-CT Data Acquired at LLNL, Specimen 1 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MT01_130725, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MT02_130729: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MT02_130729, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for LC_HT02_130812: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, lithium carbonate (LC). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, LC_HT02_130812, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for LC_HT01_130808: Micro-CT Data Acquired at LLNL, Specimen 1 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, lithium carbonate (LC). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, LC_HT01_130808, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for LC_TA03_130719: Micro-CT Data Acquired at LLNL, Specimen 3 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, lithium carbonate (LC). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, LC_TA03_130719, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images 2 . The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MP03_130620: Micro-CT Data Acquired at LLNL, Specimen 3 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MP03_130620, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images 2 . The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Statistical Techniques For Real-time Anomaly Detection Using Spark Over Multi-source VMware Performance Data

Anomaly detection refers to the identi cation of an irregular or unusual pat- tern which deviates from what is standard, normal, or expected. Such deviated patterns typically correspond to samples of interest and are assigned different labels in different domains, such as outliers, anomalies, exceptions, or malware. Detecting anomalies in fast, voluminous streams of data is a formidable chal- lenge. This paper presents a novel, generic, real-time distributed anomaly detection framework for heterogeneous streaming data where anomalies appear as a group. We have developed a distributed statistical approach to build a model and later use it to detect anomaly. As a case study, we investigate group anomaly de- tection for a VMware-based cloud data center, which maintains a large number of virtual machines (VMs). We have built our framework using Apache Spark to get higher throughput and lower data processing time on streaming data. We have developed a window-based statistical anomaly detection technique to detect anomalies that appear sporadically. We then relaxed this constraint with higher accuracy by implementing a cluster-based technique to detect sporadic and continuous anomalies. We conclude that our cluster-based technique out- performs other statistical techniques with higher accuracy and lower processing time.

Apache Spark↗

Time Distribution Analysis for Task Primitives to Support Dynamic Human Reliability Analysis

To support data collection for dynamic human reliability analysis (HRA), this study investigates time distributions for task primitives defined in the Goals, Operators, Methods, and Selection rules (GOMS)–Human Reliability Analysis (HRA) method and Human Reliability data EXtraction (HuREX). GOMS-HRA was developed to provide cognition-based time and human error probability (HEP) information for dynamic HRA calculations within the Human Unimodel for Nuclear Technology to Enhance Reliability (HUNTER) framework, while HuREX is a comprehensive HRA data collection method developed by the Korea Atomic Energy Research Institute (KAERI). In this paper, we examine time distributions by using experimental data collected from the Simplified Human Error Experimental Program (SHEEP) study, which proposes an HRA data collection framework to complement full-scope simulator research and gather input data for dynamic HRA by using simplified simulators such as the Rancor Microworld simulator. This paper investigates whether the time required for GOMS-HRA and HuREX task primitives fits 13 statistical distributions. Additionally, we compare and discuss the time distributions obtained from both student operators and professional operators. The result was that this study identified several time distributions for five GOMS-HRA and four HuREX task primitives. In the future, the results of this study are expected to provide objective reference data on the elapsed time for task primitives and aid in realistically simulating scenarios within dynamic HRA.

Dynamic Human Reliability Analysis↗

Examination of probability distribution of mixture fraction in LES/FDF modelling of a turbulent partially premixed jet flame

An accurate prediction of the probability density function (PDF) of the mixture fraction is crucial to the prediction of combustion since mixing plays an important role in turbulent non-premixed and partially premixed flames. This work provides an assessment of the large-eddy simulation (LES)/filtered density function (FDF) method for the prediction of the PDF of the mixture fraction. The advantage of the LES/FDF method is that it provides the full predictions of the statistical distribution of scalars including the mixture fraction. The predictive accuracy of the method for the PDF is yet to be fully validated. Assessing the prediction of the PDF of the mixture fraction, a conserved scalar, is an important starting point. The Sydney/Sandia inhomogeneous inlet jet flame is used as a test case. A quick comparison shows that the LES/FDF predicted PDF shapes of the mixture fraction deviate significantly from the commonly presumed Beta-PDF as well as from the experimental data in the flame. Here, to examine the source of the discrepancy, we clarify the different PDF definitions used in the comparison among the predictions, measurements, and the presumed shape PDFs. The discrepancy observed from the comparison is largely reconciled by clarifying the difference between the PDFs that are examined. The PDF of the resolved mixture fraction is shown to be close to the Beta-PDF in both the measurements and predictions, while the PDF directly deduced from the LES/FDF particles deviates significantly from the Beta-PDF. A multimodal PDF analysis and a pseudo convergence analysis are conducted to provide plausible evidence to support the predicted multimodal PDF shapes. The sub-filter scale FDF is shown to be close to the Beta-PDF too through the construction of a synthesized PDF, which supports the common presumed Beta-PDF assumption used in the presumed PDF methods when combined with LES.

42 ENGINEERING↗

Sizing Considerations for EV Dynamic Wireless Charging Systems with Integrated Energy Storage

Roadways with dynamic wireless charging systems (DWCS) enable charge-sustaining in-motion EV charging, which can reduce charging idle time while increasing range capabilities. Spatially distributed transmitter coils are controlled in response to traffic load that varies significantly minute to minute with high power levels, very short charging time, and low system utilization like wind turbine power. Traffic load estimation and localized analysis may guide effective sizing and topology adoption for feasible and scalable DWCS deployment. DWCS traffic load approximation is reviewed with measured Automated Traffic Recorder (ATR) data and statistical distributions being used to create a synthetic load analyzed using proposed metrics quantifying system utilization over time. Lumped coil section segmentation is compared between second-based distance and spatial density analysis methods, offering 17-27% greater system utilization. A peak load shifting method is proposed for traffic redirection across two tracks with optional BESS integration increasing system utilization by 50-60% depending on time-based and power reserve-based sizing and control.

Lewis, Donovin D.↗

Gravitational Effects on Closed-Cellular-Foam Microstructure

Polyurethane foam has been produced in low gravity for the first time. The cause and distribution of different void or pore sizes are elucidated from direct comparison of unit-gravity and low-gravity samples. Low gravity is found to increase the pore roundness by 17% and reduce the void size by 50%. The standard deviation for pores becomes narrower (a more homogeneous foam is produced) in low gravity. Both a Gaussian and a Weibull model fail to describe the statistical distribution of void areas, and hence the governing dynamics do not combine small voids in either a uniform or a dependent fashion to make larger voids. Instead, the void areas follow an exponential law, which effectively randomizes the production of void sizes in a nondependent fashion consistent more with single nucleation than with multiple or combining events.

Noever, David A.↗

Modeling of H2 Dispersion at ARIES

Hydrogen is a versatile and clean energy carrier that can be produced from various renewable sources such as wind, solar, and hydropower and help decarbonize electricity grids, industry, and transportation. Using the Hydrogen Research Facility under Advanced Research on Integrated Energy Systems (ARIES) at the National Renewable Energy Laboratory's (NREL) Flatirons campus as a test bench, the study examines the feasibility, useability, and value of using computational fluid dynamics (CFD) techniques to model hydrogen dispersion. The ARIES facility was chosen because controlled hydrogen releases can be performed at a rate of 27 kg-H2/hr. Site-specific atmospheric and weather condition data such as wind speed and temperature were used as inputs to the model. The results show statistical distributions and ranges of hydrogen concentrations at locations throughout the domain. Wind conditions are found to significantly impact the release behavior, including the hydrogen cloud's direction and concentrations. At low wind speeds (below 1 mph), hydrogen forms a cloud and at higher wind speeds (> 2-4 mph) hydrogen plume stretches in the direction of wind momentum. From >100 simulations for ARIES site-specific conditions, statistical quantities combined with a clustering algorithm were used to propose sensor location at various elevations from ground.

dispersion↗

MICROWAVE QUASI-PERIODIC PULSATIONS IN MULTI-TIMESCALES ASSOCIATED WITH A SOLAR FLARE/CME EVENT

Microwave observations of quasi-periodic pulsations (QPPs) in multi-timescales at the Solar Broadband Radio Spectrometer in Huairou (SBRS/Huairou) on 2006 December 13 are confirmed to be associated with an X3.4 flare/coronal mass ejection (CME) event. It is most remarkable that the timescales of QPPs are distributed in a broad range from hectoseconds (very long period pulsation, VLP, P>100 s), decaseconds (long period pulsation, LPP, 10 < P < 100 s), a few seconds (short period pulsation, SPP, 1 < P < 10 s), deciseconds (slow very short period pulsation, slow-VSP, 0.1 < P < 1.0 s), to centiseconds (fast very short period pulsation, fast-VSP, P < 0.1 s), and form a broad hierarchy. The statistical distribution of QPPs in logarithmic period-duration space indicates that all the QPPs can be classified into two groups: group I includes VLP, LPP, SPP, and some slow-VSPs distributed approximately around a line; group II includes fast-VSP and most of the slow-VSPs dispersively distributed away from the above line. This feature implies that the generation mechanism of group I is different from group II. Group I is possibly related to some MHD oscillations in magnetized plasma loops in the active region; e.g., VLPs may be generated by standing slow sausage mode coupling, resonating with the underlying photospheric 5 minute oscillation, with the modulation amplified and forming the main framework of the whole flare/CME process; LPPs, SPPs, and some slow-VSPs are most likely to be caused by standing fast modes or LRC-circuit resonance in current-carrying plasma loops. Group II is possibly generated by modulations of resistive tearing-mode oscillations in electric current-carrying flaring loops.

79 ASTRONOMY AND ASTROPHYSICS↗

Utilizing Advanced Statistics to Determine Anomalistic Conditions in Pebble-Bed Reactors

Pebble-bed reactors (PBRs) utilize hundreds of thousands of fuel pebbles, which continuously circulate through the core, in lieu of traditional fuel assemblies to generate fissions and produce power. The use of unmarked fuel pebbles presents a challenge for international safeguards verification that nuclear material is not being diverted. To ensure pebble diversion is not taking place, new methods for accounting for and monitoring the pebbles should be examined to determine an appropriate methodology for performing bulk accountancy with pebbles. Here, this work examines the use of statistical methods for determining if the reactor is within a declared range of operation by examining the statistical distribution of pebble burnup as they are discharged from the core. Using this methodology, we created a model that detects diversion over 95% of the time, over multiple diversion pathways, if the reactor core maintains a constant power density during the diversion process and only falsely labels a diversion case nominal 2% of the time. For a diversion scenario where the reactor is maintained at a constant power, the statistical analysis can correctly identify if diversion is occurring over 80% of the time; however, nearly 20% of specific diversion pathways are mislabeled nominal. These results provide a basis and framework for exploring the further use of statistical methods to determine where these methods could be most useful and where additional methods, such as machine learning, could be used to capture if diversion is occurring in pebble-bed reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fuel performance analysis of fully-resolved TRISO compact

The TRi-structural ISOtropic (TRISO) fuel multilayered coating structure offers multiple barriers to fission product release, enhancing safety and performance. The heterogeneous nature of TRISO fuel compacts, comprising thousands of randomly distributed coated fuel particles embedded in a graphite matrix, creates intricate stress fields and thermal gradients that cannot be accurately modeled using simplified one-dimensional or homogenized approaches. Consequently, three-dimensional modeling enables the prediction of fuel compact dimensional changes, internal pressure buildup, and fission product transport pathways under diverse irradiation and thermal conditions. This capability facilitates detailed analysis of particle-to-particle interactions, matrix cracking mechanisms, and the statistical distribution of coating failures, which directly impact fuel performance and safety margins. This capability is particularly critical for advanced reactors, such as high-temperature gas-cooled reactors and other Generation IV reactor designs where TRISO fuel operates at elevated temperatures and burn-up levels. This work introduces a novel method to generate an optimized packing of TRISO compacts and a complete 3D mesh with random distribution of TRISO particles, which are discretized into each coating component layer.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗