Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Intrinsically stretchable electrode array enabled in vivo electrophysiological mapping of atrial fibrillation at cellular resolution

Electrophysiological mapping of chronic atrial fibrillation (AF) at high throughput and high resolution is critical for understanding its underlying mechanism and guiding definitive treatment such as cardiac ablation, but current electrophysiological tools are limited by either low spatial resolution or electromechanical uncoupling of the beating heart. To overcome this limitation, here we introduce a scalable method for fabricating a tissue-like, high-density, fully elastic electrode (elastrode) array capable of achieving real-time, stable, cellular level-resolution electrophysiological mapping in vivo. Testing with acute rabbit and porcine models, the device is proven to have robust and intimate tissue coupling while maintaining its chemical, mechanical, and electrical properties during the cardiac cycle. The elastrode array records epicardial atrial signals with comparable efficacy to currently available endocardial-mapping techniques but with 2 times higher atrial-to-ventricular signal ratio and >100 times higher spatial resolution and can reliably identify electrical local heterogeneity within an area of simultaneously identified rotor-like electrical patterns in a porcine model of chronic AF.

60 APPLIED LIFE SCIENCES↗

Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy (DOE SBIR Phase II/IIA Final Report)

Actoprobe LLC reports on the results of its DOE SBIR Phase II/IIA project on the development of Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy. While chemistry science and technology greatly benefit from Atomic Force Microscopy in surface characterization, time-resolved chemical imaging on the single-molecule level lags far behind. Current scanning probe microscopy only obtains information about mechanical but not optical/chemical properties. To address this problem, the Actoprobe LLC research team has proposed a novel class of Atomic Force Microscopy probes, Ultra-Fast Pulsed Active Atomic Force Microscopy Optical Probes (UFP AAOPs), that will allow ultrafast time-resolved optical and chemical imaging at the nanoscale. As envisioned, these unique optical probes will perform the functions of conventional Atomic Force Microscopy probes and, in addition, will simultaneously provide chemical information about molecular scale interactions. This innovation is accomplished by integrating an ultrafast pulsed Quantum Dot laser source into an Atomic Force Microscopy probe. This report describes our progress with the fabrication of an ultrafast micrometer-size semiconductor laser, based on “artificial atoms” - Quantum Dots, integrated with an Atomic Force Microscopy probe. In this Phase II/IIA project, we have demonstrated the feasibility of the UFP AAOP concept by fabricating a first prototype of the UFP AAOP. The excellent performance of the probe has been proven in terms of AFM and optical spatial resolution through rigorous tests. The UFP AAOP provides pulses with less than 4 ps duration and higher than 11 GHz repetition rate, and spatial resolution better than 300 nm at 1240 nm wavelength. Technically, it is possible to reduce the pulse width to less than 1 ps and to improve lateral resolution to ~ 0.5 nm, which implies the potential capability for the probe to characterize chemical compounds with single-molecule resolution. The UFP AAOP fabrication procedure has been developed for wafer-scale production of multiple devices, with the yield of the process estimated to be lower than 1% with the limited fabrication capabilities and equipment available for use in the research project. However, using high-volume production tools and special GaAs processing equipment, the yield can be significantly improved, theoretically to ~ 50%. Finally, economic feasibility and scale-up manufacturing potential were analyzed for UFP AAOP and found to be very promising. In summary, the Actoprobe team has successfully demonstrated the feasibility of the UFP AAOP concept.

36 MATERIALS SCIENCE↗

Experimental investigation of thermal conductivity of high entropy ceramics

In this talk, we will present the experimental investigation of thermal conductivity of high entropy carbides (HEC) and borides (HEB) with different compositions. Thermal conductivity determines the capability of a material to transport thermal energy and is considered as one critical physical property, specially in the energy industry. Due to the presences of disordered cation sublattice, it is expected that thermal conductivity of high entropy ceramics is lower than the counterparts with simpler compositions, but the experimental studies are relatively few. Using laser-based spatial-domain and frequency-domain thermoreflectance technique, we measured thermal conductivity of HECs and HEBs in a temperature range from 77K to 773K. Furthermore, by focusing the laser using an objective lens, we were able to perform the thermal property mapping on samples with the spatial resolution of micrometer. Such measurements could reveal important microstructure information in a rapid and efficient way without using scanning electron microscopy. The high spatial resolution also enables thermal conductivity measurements on ion-irradiated HECs with the damage layer of merely 1.1µm. These measurements can provide valuable information to predict the performances of HECs and HEBs with different compositions and from different manufacturing processes, and in the extreme environments such as nuclear reactors.

36 - MATERIALS SCIENCE↗

Development and characterization of a laser-gated, high resolution x-ray radiography platform for high energy density experiments using toroidally bent crystals

Bent crystal x-ray imagers are a well-established diagnostic tool to study high energy density (HED) objects by acquiring two-dimensional x-ray radiographs. Often, studying these HED objects requires very high spatial resolution, which is limited by astigmatism when using spherically bent crystals. By using toroidal-shaped crystals instead, astigmatism can be reduced and the overall spatial resolution of the instrument improved. Here, the development and characterization of a laser-gated x-ray radiography platform at the National Ignition Facility using a toroidal crystal is presented. This includes measurements of the spatial and temporal profile, which is determined by the x-ray source. In conclusion, to properly validate the reduced astigmatism, a new multi-plane grid approach was implemented, which, for the first time, allows a depth of field measurement, alignment verification and x-ray source size estimate in a single shot, demonstrating the current platform’s capability to provide sub-10 μm resolution over a 0.9 mm depth of field with a temporal resolution of 110 ps.

Crystal optics↗

Fresnel zone plate development for x-ray radiography of hydrodynamic instabilities at the National Ignition Facility

The study of Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high energy densities at the National Ignition Facility (NIF) requires high spatial resolution imaging. We demonstrate the potential of Fresnel zone plates (FZPs) to achieve resolution that would unlock such studies. FZPs are circular aperiodic gratings that use diffraction to focus x rays and produce an image with high spatial resolution. Taking into account the NIF’s challenging environment, we have designed a specific array of five FZPs for a zinc backlighter to take a radiograph of a target with 9 keV x rays. We measured a mean resolution for the FZP of 1.9µm±0.5µm and a ±1mm depth of focus at an x-ray calibration facility as well as a 2.3µm±0.4µm resolution on a resolution wire mesh shot on the NIF. We also performed an in-depth analysis of the image quality to assess the capability to resolve the small features present in RT and RM instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dual-Comb Spectroscopy to Tethered Balloon System (DCS to TBS) Field Campaign Report

There is a critical need for the ability to detect, quantify, and attribute sources and sinks of greenhouse gases (GHGs) with high temporal and spatial resolution. Current methods are typically based on continuously operating near-surface point sensors or intermittent aerial/satellite observations. Dual optical frequency comb spectroscopy (“dual-comb spectroscopy”; DCS) is a laser-based technique that can bridge this sensing gap by providing high-precision, high-accuracy, and high-temporal-resolution detection and quantification of trace gases over kilometer-length scales, connecting local and regional observations. A single DCS system can also provide spatial resolution for source/sink attribution with the addition of a few minor optical elements, enabling cross-validation of other observations (e.g., Total Carbon Column Observing Network [TCCON], Orbiting Carbon Observatory [OCO-2/3], Greenhouse Gases Observing Satellite [GOSAT-1/2][).

54 ENVIRONMENTAL SCIENCES↗

Skin-integrated stretchable actuators toward skin-compatible haptic feedback and closed-loop human-machine interactions

Abstract Skin-integrated haptic interfaces that can relay a wealth of information from the machine to the human are of great interest. However, existing haptic devices are not yet able to produce haptic cues that are compatible with the skin. In this work, we present the stretchable soft actuators for haptic feedback, which can match the perception range, spatial resolution, and stretchability of the skin. Pressure-amplification structures are fabricated using a scalable self-assembly process to ensure an output pressure beyond the skin perception threshold. Due to the minimized device size, the actuator array can be fabricated with a sufficiently high spatial resolution, which makes the haptic device applicable for skin locations with the highest spatial acuity. A haptic feedback system is demonstrated by employing the developed soft actuators and highly sensitive pressure sensors. Two proof-of-concept applications are developed to illustrate the capability of transferring information related to surface textures and object shapes acquired at the robot side to the user side.

Chen, Si↗

Johnson-noise-limited cancellation-free microwave impedance microscopy with monolithic silicon cantilever probes

Abstract Microwave impedance microscopy (MIM) is an emerging scanning probe technique for nanoscale complex permittivity mapping and has made significant impacts in diverse fields. To date, the most significant hurdles that limit its widespread use are the requirements of specialized microwave probes and high-precision cancellation circuits. Here, we show that forgoing both elements not only is feasible but also enhances performance. Using monolithic silicon cantilever probes and a cancellation-free architecture, we demonstrate Johnson-noise-limited, drift-free MIM operation with 15 nm spatial resolution, minimal topography crosstalk, and an unprecedented sensitivity of 0.26 zF/ √ Hz. We accomplish this by taking advantage of the high mechanical resonant frequency and spatial resolution of silicon probes, the inherent common-mode phase noise rejection of self-referenced homodyne detection, and the exceptional stability of the streamlined architecture. Our approach makes MIM drastically more accessible and paves the way for advanced operation modes as well as integration with complementary techniques.

47 OTHER INSTRUMENTATION↗

Nanoscale Mapping of Hydrogen Distribution in Nuclear Structural Materials Using Cryogenic Transfer Atom Probe Tomography

Analyzing hydrogen distribution in nuclear structural materials at sub-nanometer scale spatial resolution has been challenging by electron microscopy. Furthermore, methods such as thermal desorption spectroscopy only provides a bulk estimate of hydrogen concentration with no nanoscale spatial resolution. In the last decade, cryogenic transfer atom probe tomography (APT) has been emerging as an invaluable characterization technique for analyzing the nanoscale distribution of hydrogen isotopes in materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Resolution Meteorology with Climate Change Impacts from Global Climate Model Data Using Generative Machine Learning

As renewable energy generation increases, the impacts of weather and climate on energy generation and demand become critical to the reliability of the energy system. However, these impacts are often overlooked. Global climate models (GCMs) can be used to understand possible changes to our climate, but their coarse resolution makes them difficult to use in energy system modelling. Here we present open-source generative machine learning methods that produce meteorological data at a nominal spatial resolution of 4 km at an hourly frequency based on inputs from 100 km daily-average GCM data. These methods run 40 times faster than traditional downscaling methods and produce data that have high-resolution spatial and temporal attributes similar to historical datasets. We demonstrate that these methods can be used to downscale projected changes in wind, solar and temperature variables across multiple GCMs including projections for more frequent low-wind and high-temperature events in the Eastern United States.

climate change↗

“4H” X-ray camera

A 4H X-ray camera includes a high speed, high atomic number (Z), high spatial resolution sensor for sensing X-rays having energy over 30 keV and high speed readout electronics, and the high speed, high atomic number (Z), high spatial resolution sensor is coupled to the high speed readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed fiber-optic sensor network for sensing the corrosion onset and quantification

Materials, methods of making, and methods of sensing liquid droplets with high spatial resolution as a signature of the on-set of corrosion using a hierarchical sensor network A hierarchical sensor network for sensing liquid droplets with high spatial resolution as a signature of the on-set of corrosion, including an interrogation system; and an intermediate sensor array layer in communication with the interrogation system. The network includes an interrogation system and an intermediate sensor array layer in communication with the interrogation system.

Ohodnicki, Paul R.↗

Aerial imagery dataset of lost oil wells

Orphaned wells are wells for which the operator is unknown or insolvent. The location of hundreds of thousands of these wells remain unknown in the United States alone. Cost-effective techniques are essential to locate orphaned wells to address environmental problems. In this paper, we present a dataset consisting of 120,948 aerial images of recently documented orphan wells. Each of these 512 × 512 images is paired with segmentation masks that indicate the presence or absence of such well. These images, sourced from the National Agriculture Imagery Program, cover the continental United States with spatial resolutions ranging from 30 centimeters to 1 meter. Additionally, we included negative examples by selecting locations uniformly across the United States. Accompanying metadata includes the IDs and spatial resolution of the original images, which are available for free through the United States Geological Survey, and the pixel coordinates of documented orphaned wells identified in these images. This dataset is intended to support the development of deep-learning models that can help locating undocumented orphan wells from such imagery, thereby blunting the environmental damage they do.

Climate-change mitigation↗

Simulating 50 keV X-ray Photon Detection in Silicon with a Down-Conversion Layer

Simulation results are presented that explore an innovative, new design for X-ray detection in the 20–50 keV range that is an alternative to traditional direct and indirect detection methods. Typical indirect detection using a scintillator must trade-off between absorption efficiency and spatial resolution. With a high-Z layer that down-converts incident photons on top of a silicon detector, this design has increased absorption efficiency without sacrificing spatial resolution. Simulation results elucidate the relationship between the thickness of each layer and the number of photoelectrons generated. Further, the physics behind the production of electron-hole pairs in the silicon layer is studied via a second model to shed more light on the detector’s functionality. Together, the two models provide a greater understanding of this detector and reveal the potential of this novel form of X-ray detection.

47 OTHER INSTRUMENTATION↗

Integration of fixed-frequency and FM-CW (frequency-modulated continuous-wave) reflectometers for coincident turbulence measurements on LTX- β (Lithium Tokamak eXperiment- β )

The fixed-frequency and frequency-modulated continuous-wave (FM-CW) reflectometers on LTX-β (Lithium Tokamak eXperiment-β) have been configured to use the same transmission lines and antenna arrays for coincident views of the core and edge plasma. The fixed-frequency channels (13.1–20.5 and 20–40 GHz, tunable between discharges) provide time-resolved measurements of density fluctuations, while the FM-CW channels (13.1–20.2 and 19.5–33.5 GHz) measure the density profile and fluctuations, with high spatial resolution and a sampling rate determined by the frequency sweep interval (5 μs). Data from both reflectometers are synchronously acquired to simultaneously leverage the wide bandwidth and high spatial resolution of the respective systems. Experiments showed that mutual crosstalk interference is momentary and does not diminish the capability of either system. Spectral analysis indicated broad power spectra (several hundreds of kHz) and suggests that the signals from the FM-CW system are consistent with under-sampled fixed-frequency signals. Radial correlations were explored using data from the two reflectometers, as well as from the FM-CW system alone. The core channels showed high levels of agreement between these two comparisons, suggesting that the data from the reflectometers are interchangeable for statistical estimates. For the edge channels, comparisons using data from the FM-CW reflectometer alone showed significant decorrelation due to time lag caused by the finite frequency up-sweep duration. Alternatively, this effect is eliminated when cross-correlating data from the different reflectometers. Finally, these results highlight the advantages of operating the fixed-frequency and FM-CW reflectometers in this manner, where the combined system can overcome the limitations of each separate system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray near-field multi-slice ptychography for in-situ imaging

Abstract In-situ imaging of chemical reactions can provide valuable insight into nanoparticle growth and structural evolution. Hard X-ray imaging is an excellent tool for this purpose, as it combines high spatial resolution with high penetration depth, allowing for realistic reaction environments. While far-field ptychography is a well-established method at synchrotron radiation sources, its near-field analog has received less attention. In this work we show that near-field multi-slice ptychography is a competitive method for high-resolution in-situ imaging by studying the formation of gold nanocages via galvanic replacement. Our work extends near-field X-ray ptychography to sub-50 nm spatial resolution by using multilayer Laue lenses. These high numerical aperture optics enable to distinguish sample layers that are separated by less than 100 µm by multi-slicing techniques.

Science & Technology - Other Topics↗

Helium Ion Microscopy with Secondary Ion Mass Spectrometry for Nanoscale Chemical Imaging and Analysis of Polyolefins

To date, chemical imaging of polymers and polymer blends has been primarily accomplished using time-of-flight secondary ion mass spectrometry (ToF-SIMS) to directly visualize the distribution of components in a complex material with spatial resolution ranging from 100 nm to 5 μm. However, in many cases, this resolution falls far short of visualizing interfaces directly. To overcome these limitations, recent work has focused on developing a SIMS detection system based on a helium ion microscope (HIM) enabling chemical imaging with a demonstrated ~14 nm spatial resolution. Here, we utilize HIM-SIMS for differentiation between the olefin-based polymers of polyethylene (PE) and polypropylene (PP). We illustrate both analyses for separating PE and PP using specific mass fragment ratios as well as demonstrate spatially resolved imaging of phase-separated domains within PE. Altogether, we demonstrate the abilities of HIM-SIMS as a multimodal chemical technique for imaging and quantification of polyolefin interfaces, which could be more broadly applied to the analysis of more complex polymeric systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗