Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shielding design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

On the production of neutrons in laminated barriers for 10 MV medical accelerator rooms

When space limitations are primary constraints, laminated barriers with metals can be an option to provide sufficient shielding for a radiotherapy treatment room. However, if a photon clinical beam with end point energy of 10 MeV or higher interacts with the metal inside the barriers neutrons are ejected and can result in an exposure problem inside and outside the vault. The empirical formulae existing in the literature to estimate neutron dose equivalents beyond laminated barriers do not take into account neutron production for spectra below 15 MV. In this work, the Monte Carlo code MCNP was used to simulate the production and transport of photoneutrons across primary barriers of 10 MV accelerator treatment rooms containing lead or steel, in order to obtain the ambient dose equivalents produced by these particles outside the room and in the patient plane. It was found that the neutron doses produced are insignificant when steel is present in the primary barriers of 10 MV medical accelerators. On the other hand, the results show that, in all cases where lead sheets are positioned in the primary barriers, the neutron ambient dose equivalents outside the room generally exceed the shielding design goal of 20 {mu}Sv/week for uncontrolled areas, even when the lead sheets are positioned inside the treatment room. Moreover, for laminated barriers, the photoneutrons produced in the metals are summed with the particles generated in the accelerator head shielding and can represent a significant component of additional dose to the patients. In this work, it was found that once lead sheets are positioned inside the room, the neutron ambient dose equivalents can reach the value of 75 {mu}Sv per Gray of photon absorbed dose at the isocenter. However, for all simulated cases, a tendency in the reduction of neutron doses with increasing lead thickness can be observed. This trend can imply in higher neutron ambient dose equivalents outside the room for thinner lead sheets. Therefore, when a medical accelerator treatment room is designed with laminated barriers to receive equipment with an end point energy equal to or higher than 10 MeV, not only the required shielding thickness for photon radiation attenuation should be considered, but also the dose due to photoneutrons produced in the metal, which may involve an increase of the lead thickness or even the use of neutron shielding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-G-213-01: IEC and US Committee Activities and Organizational Structure

The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

60 APPLIED LIFE SCIENCES↗

Shielding analysis for a manned Mars rover powered by an SP-100 type reactor

Shield design is one of the most crucial tasks in the integration of a nuclear reactor power system to a manned Mars rover. A multilayered W and LiH shield is found to minimize the shield mass and satisfy the dose rate limit of 30 rem/y to the rover crew. The effect on dose rate of tungsten layers thicknesses and position within the lithium hydride shields is investigated. Due to the large cross section for the W (n,gamma) reaction, secondary gammas become a significant radiation source. The man-rated shield mass for the Mars rover vehicle is correlated to the reactor thermal power. The correlation fits to within 9 percent of the calculated shield mass and results in an uncertainty of below 4 percent in the overall rover mass. The shield mass varied from 8600 kg to 20580 kg for a reactor thermal power of 100 to 1000 kW(t), respectively.

Morley, Nicholas J.↗

Griffin Capability Improvements in Support of Ex-core Deep-Penetration Problems

Advanced reactor designs, especially portable reactors that are designed to be located closer to humans and operate autonomously, require the ability to accurately compute the ex-core neutron and gamma flux solutions in terms of shielding design optimization to reduce dose rates at the vessel boundary and detector signal prediction to drive the reactor control system. The Nuclear Energy Advanced Modeling and Simulation program has prioritized improvements to the Griffin discrete ordinates (SN) solver for deep-penetration problems in fiscal year 2025. Significant advancements have been made to the Griffin methodologies for solving ex-core deep-penetration problems for steady-state, fixed-source and transient calculations. This work presents the methodology improvements as well as a comprehensive demonstration with a Transient Test Reactor model and measurements.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

3D Printing Heat Shields

Heat shields that protect spacecraft from the heat of entering a planet's atmosphere are labor intensive to manufacture, cost prohibitive and the heat shield design is constrained by the manufacturing process. Little, if any, automation is used to manufacture and install the thermal protection system (TPS) on the vehicles and most heat shields are segmented with many seams and gaps. The goal of this project is to change this paradigm by developing new TPS materials and taking advantage of additive manufacturing technology to automate the processes for making and installing monolithic, ablative TPS on large entry vehicles.

Bouslog, Stan↗

Several preliminary designs for heavy-lift earth-to-orbit transport

Several design concepts are identified for earth-to-orbit delivery of payloads in the 200 Mg range. The concept include winged vehicles which take-off vertically and land horizontally and ballistic shapes similar to the Gemini or Mercury vehicles which take-off and land vertically. Major technology issues include stability problems for the winged vehicle with large base mounted engines and heat shield design problems for the ballistic vehicle, the latter requiring doors in the heat shield for the main engines.

Brien, E. P.↗

LANL Activities Supporting Electron Accelerator Production of 99 Mo for NorthStar Medical Radioisotopes, LLC

Summary of LANL FY12 Activities are: (1) Preparation, performance, and data analysis for the FY12 accelerator tests at ANL - (a) LANL designed and installed a closed-loop helium target cooling system at ANL for the FY12 accelerator tests, (b) Thermal test was performed on March 27, (c) 24 h production test to follow the accelerator upgrade at ANL; (2) Local target shielding design and OTR/IR recommendations - (a) Target dose rate and activation products were calculated with MCNPX, (b) 206 Pb(γ,2n) 204m Pb vs 204g Pb branching ratio unpublished, will measure using the LANL microtron, (c) OTR system nearing final configuration, (d) IR prototype system demonstrated during the recent thermal test at ANL; (3) Target housing lifetime estimation - Target housing material specifications and design to be finalized following the thermal test, lifetime not believed to be an issue; and (4) Target cooling system reliability - Long duration system characterizations will begin following the thermal test.

42 ENGINEERING↗

Background suppression in the Edelweiss-III experiment

In dark matter WIMP searches the neutron shielding plays a crucial role in attenuating neutron flux and hence, suppressing nuclear recoil event rate - one of the key background mimicking WIMP interactions. The transition from EDELWEISS-II to EDELWEISS-III with 40 detectors with increased mass and improved background rejection has required the modification of the neutron shielding. In this paper we describe the new neutron shielding design and give an estimate of the expected neutron rate in comparison with the previous stage of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Two-Stage Light Gas Gun for Muzzle Velocities of 10 - 11 kms

Space debris poses a major risk to spacecraft. In low earth orbit, impact velocities can be 10 11 kms and as high as 15 kms. For debris shield design, it would be desirable to be able to launch controlled shape projectiles to these velocities. The design of the proposed 10 11 kmsec gun uses, as a starting point, the Ames 1.280.22 two stage gun, which has achieved muzzle velocities of 10 11.3 kmsec. That gun is scaled up to a 0.3125 launch tube diameter. The gun is then optimized with respect to maximum pressures by varying the pump tube length to diameter ratio (LD), the piston mass and the hydrogen pressure. A pump tube LD of 36.4 is selected giving the best overall performance. Piezometric ratios for the optimized guns are found to be 2.3, much more favorable than for more traditional two stage light gas guns, which range from 4 to 6. The maximum powder chamber pressures are 20 to 30 ksi. To reduce maximum pressures, the desirable range of the included angle of the cone of the high pressure coupling is found to be 7.3 to 14.6 degrees. Lowering the break valve rupture pressure is found to lower the maximum projectile base pressure, but to raise the maximum gun pressure. For the optimized gun with a pump tube LD of 36.4, increasing the muzzle velocity by decreasing the projectile mass and increasing the powder loads is studied. It appears that saboted spheres could be launched to 10.25 and possibly as high as 10.7 10.8 kmsec, and that disc-like plastic models could be launched to 11.05 kms. The use of a tantalum liner to greatly reduce bore erosion and increase muzzle velocity is discussed. With a tantalum liner, CFD code calculations predict muzzle velocities as high as 12 to 13 kms.

Gun Design↗

Design of a Two-Stage Light Gas Gun for Muzzle Velocities of 10 - 11 km/s

Space debris poses a major risk to spacecraft. In low earth orbit, impact velocities can be 10 - 11 km/s and as high as 15 km/s. For debris shield design, it would be desirable to be able to launch projectiles of known shape and mass to these velocities. The design of the proposed 10 - 11 km/sec gun uses, as a starting point, the Ames 1.28”/0.22” two stage gun, which has achieved muzzle velocities of 10 - 11.3 km/sec. That gun is scaled up to a 0.3125” launch tube diameter. The gun is then optimized with respect to maximum pressures by varying the pump tube length to diameter ratio (L/D), the piston mass and the hydrogen pressure. A pump tube L/D of 36.4 is selected giving the best overall performance. Piezometric ratios for the optimized guns are found to be ~2.3, much more favorable than for more traditional two stage light gas guns, which range from 4 to 6. (The piezometric ratio for a gun is defined as the maximum projectile base pressure divided by the constant projectile base pressure which, acting over the entire barrel length, would produce the same muzzle velocity.) The maximum powder chamber pressures are 20 to 30 ksi. To reduce maximum pressures, the desirable range of the included angle of the cone of the high pressure coupling is found to be 7.3 to 14.6 degrees. Lowering the break valve rupture pressure is found to lower the maximum projectile base pressure, but to raise the maximum gun pressure. For the optimized gun with a pump tube L/D of 36.4, increasing the muzzle velocity by decreasing the projectile mass and increasing the powder loads is studied. It appears that saboted spheres could be launched to 10.25 and possibly as high as 10.8 km/sec, and that disc-like plastic models could be launched to 11.05 km/s. The use of a tantalum liner to greatly reduce bore erosion and increase muzzle velocity is discussed. With a tantalum liner, CFD code calculations predict muzzle velocities as high as 12 to 13 km/s.

Bogdanoff, David W.↗

Measurement and Monte Carlo simulation of 3D neutrons distribution in a radiotherapy bunker - 25411

Different methods exist to verify bunkers design for radiation therapy medical facilities; analytical methods based on simplified equations and Monte Carlo methods. One of the main purposes of this work is to present the advantages of using Monte Carlo simulation to verify radiotherapy bunker shielding design. This methodology is more accurate and characterizes not only the fluence and dose three-dimensionally, but also the energy spectrum of particles generated by the Linac. The other main purpose of the work is to analyze the importance of the generated photoneutrons when the Linac emits photon beams of high energy (above 8 MeV), since numerous studies have found that they can expose the patient and clinical staff to non-negligible dose. The main novelty introduced by this work, is the creation of more realistic simulation models to represent the radiotherapy facility by using CAD and meshes technologies. Results obtained using these bunker simulation models have been validated experimentally at the Hospital Universitari i Politecnic La Fe de Valencia facilities using two different neutron detectors; the neutron meter LB 6411 (designed between Berthold and Karlsruhe Research Center) and neutron detector model 42 - 41L (Ludlum, Prescila). Results obtained with Monte Carlo and those measured experimentally fit correctly, validating this analysis methodology. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation shielding for superconducting RF cavity test facility at A0

The results of Monte Carlo radiation shielding study performed with the MARS15 code for the vertical test facility at the A0 north cave enclosure at Fermilab are presented and discussed. The vertical test facility at the A0 north cave is planned to be used for testing 1.3 GHz single-cell superconducting RF cavities with accelerating length of 0.115 m. The operations will be focused on high accelerating gradients--up to 50 MV/m. In such a case the facility can be a strong radiation source [1]. When performing a radiation shielding design for the facility one has to take into account gammas generated due to interactions of accelerated electrons with cavity walls and surroundings (for example, range of 3.7-MeV electrons in niobium is approximately 3.1 mm while the thickness of the niobium walls of such RF cavities is about 2.8 mm). The electrons are usually the result of contamination in the cavity. The radiation shielding study was performed with the MARS15 Monte Carlo code [2]. A realistic model of the source term has been used that describes spatial, energy and angular distributions of the field-emitted electrons inside the RF cavities. The results of the calculations are normalized using the existing experimental data on measured dose rate in the vicinity of such RF cavities.

43 PARTICLE ACCELERATORS↗

Radiation Protection Around High-intensity Laser Interactions with Solid Targets

Interaction of a high-intensity optical laser with a solid target can generate an ionizing radiation hazard in the form of high-energy "hot" electrons and bremsstrahlung, resulting from hot electrons interacting with the target itself and the surrounding target chamber. Previous studies have characterized the bremsstrahlung dose yields generated by such interactions for lasers in the range of 10 17 to 10 22 W cm -2 using particle-in-cell code EPOCH and Monte Carlo code FLUKA. Electron measurements based on a depth-dose approach are presented for two laser intensities, which indicate a Maxwellian distribution is more suitable for estimating the hot electrons' energy distribution. Also, transmission factors for the resulting bremsstrahlung for common shielding materials are calculated with FLUKA, and shielding tenth-value-layer thicknesses are also derived. In combination with the bremsstrahlung dose yield, the tenth-value layers provide radiation protection programs the means to evaluate radiation hazards and design shielding for high-intensity laser facilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Whipple Bumper Shield Simulations [Book Chapter]

The Whipple bumper is a space shield designed to protect a space station from the most hazardous orbital space debris environment. A series of numerical simulations has been performed using the multi-dimensional hydrodynamics code CTH to estimate the effectiveness of the thin Whipple bumper design. These simulations are performed for impact velocities of ~ 10 km/s which are now accessible by experiments using the Sandia hypervelocity launcher facility. For a ~ 10 km/s impact by a 0.7 gm aluminum flier plate, the experimental results indicate that the debris cloud resulting upon impact of the bumper shield by the flier plate, completely penetrates the sub-structure. The CTH simulations also predict complete penetration by the subsequent debris cloud.

36 MATERIALS SCIENCE↗

Optimization Studies for Radiation Shielding of a Superconducting RF Cavity Test Facility

Test facilities for high-gradient superconducting RF cavities must be shielded for particle radiation, which is generated by field emitted electrons in the cavities. A major challenge for the shielding design is associated with uncertainty in modeling the field emission. In this work, a semi-empirical method that allows us to predict the intensity of the generated field emission is described. Spatial, angular and energy distributions of the generated radiation are calculated with the FISHPACT code. The Monte Carlo code MARS15 is used for modeling the radiation transport in matter. The detailed distributions of the generated field emission are used for studies with 9-cell 1.3 GHz superconducting RF cavities in the Fermilab Vertical Cavity Test Facility. This approach allows us to minimize the amount of shielding inside cryostat which is an essential operational feature.

43 PARTICLE ACCELERATORS↗

Preliminary thermal analysis for Saturn entry

A preliminary thermal analysis based on recently defined Saturn entry conditions has been conducted. The study, using viscous-shock-layer and engineering codes employed for Project Galileo, investigated nonequilibrium chemistry effects on the Saturn thermal environment, defined the primary heat-transfer mode for heatshield design, delineated some problem areas for future thermal studies, and validated BIRCHES (Blunt Body Inviscid Radiative and Convective Heating Engineering Solutions) for parametric or design studies. The effect of nonequilibrium chemistry appears to significantly influence only the radiative fluxes with effects localized to the stagnation region. However, the heat-transfer mode pertinent to the overall heat-shield design is convection. The convective results of BIRCHES and a detailed code are in good agreement. The resulting mass-loss rates for the currently prescribed nominal Saturn entry conditions are small when compared with the values for nominal Jupiter entry conditions. With coupled carbon-phenolic ablation injection, the convective heating rates are reduced substantially while the radiative heating rates are increased when compared with the corresponding no-injection results.

Zoby, E. V.↗

IAEA Photonuclear Data Library 2019

Here, photo-induced reaction cross section data are of importance for a variety of current or emerging applications, such as radiation shielding design and radiation transport analyses, calculations of absorbed dose in the human body during radiotherapy, physics and technology of fission reactors (influence of photo-reactions on neutron balance) and fusion reactors (plasma diagnostics and shielding), activation analyses, safeguards and inspection technologies, nuclear waste transmutation, medical isotope production and astrophysical applications. To address these data needs the IAEA Photonuclear Data library was produced in 1999, containing evaluated photo-induced cross sections and neutron spectra for 164 nuclides which were deemed relevant for the applications. Since the release of the IAEA Photonuclear Data Library however, new experimental data as well as new methods to assess the reliability of experimental cross sections have become available. Theoretical models and input parameters used to evaluate photo-induced reactions have improved significantly over the years. In addition, new measurements of partial photoneutron cross sections using mono-energetic photon beams and advanced neutron detection systems have been performed allowing for the validation of the evaluations and assessments of the experimental data. Furthermore, technological advances have led to the construction of new and more powerful gamma-beam facilities, therefore new data needs are emerging. We report our coordinated efforts to address these data needs and present the results of the new up-to-date evaluations included in the new updated IAEA Photonuclear Data Library consisting of 219 nuclides. The new library includes 188 new evaluations produced by the CRP evaluators, and one evaluation taken from the JENDL/PD-2016 library, while 20 evaluations were retained from the previous 1999 IAEA Photonuclear Data Library. In most of the cases, the photon energy goes up to 200 MeV. A total of 55 nuclides are new in this library reflecting the progress in measurements but also the developing data needs. In this paper we discuss the new assessment method and make recommendations to the user community in cases where the experimental data are discrepant and the assessments disagree. In addition, in the absence of experimental data, we present model predictions for photo-induced reaction cross section on nuclides of potential interest to medical radioisotope production.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗