Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

System and method for in situ inspection of defects in additively manufactured parts using high speed melt pool pyrometry

A system and method is disclosed for detecting anomalies in an additively manufactured part. An energy source generates a signal forming an optical beam for creating a melt pool in a layer of feedstock material being selectively fused to make a part in an additive manufacturing operation. A sensor is configured to receive a signal reflected from the melt pool. The reflected signal forms a thermal signal indicative of a temperature of the feedstock material at a known location on a layer of the feedstock material while the feedstock material is being fused at the known location. A controller receives and analyzes data relating to the received signal to determine if an anomaly exists at the known location.

Forien, Jean-Baptiste↗

Toward Long-Term Accurate and Continuous Monitoring of Nitrate in Wastewater Using Poly(tetrafluoroethylene) (PTFE)–Solid-State Ion-Selective Electrodes (S-ISEs)

Long-term accurate and continuous monitoring of nitrate (NO 3 – ) concentration in wastewater and groundwater is critical for determining treatment efficiency and tracking contaminant transport. Current nitrate monitoring technologies, including colorimetric, chromatographic, biometric, and electrochemical sensors, are not feasible for continuous monitoring. In this work, we addressed this challenge by modifying NO 3 – solid-state ion-selective electrodes (S-ISEs) with poly(tetrafluoroethylene) (PTFE, (C 2 F 4 ) n ). The PTFE-loaded S-ISE membrane polymer matrix reduces water layer formation between the membrane and electrode/solid contact, while paradoxically, the even more hydrophobic PTFE-loaded S-ISE membrane prevents bacterial attachment despite the opposite approach of hydrophilic modifications in other antifouling sensor designs. Specifically, an optimal ratio of 5% PTFE in the S-ISE polymer matrix was determined by a series of characterization tests in real wastewater. Five percent of PTFE alleviated biofouling to the sensor surface by enhancing the negative charge (–4.5 to –45.8 mV) and lowering surface roughness (Ra: 0.56 ± 0.02 nm). It simultaneously mitigated water layer formation between the membrane and electrode by increasing hydrophobicity (contact angle: 104°) and membrane adhesion and thus minimized the reading (mV) drift in the baseline sensitivity (“data drifting”). Long-term accuracy and durability of 5% PTFE-loaded NO 3 – S-ISEs were well demonstrated in real wastewater over 20 days, an improvement over commercial sensor longevity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of the Anionic Zinc-Adeninate Metal–Organic Framework Structure on the Luminescent Detection of Rare Earth Ions in Aqueous Streams

Rare earth elements (REEs) are critical to numerous technologies; however, a combination of increasing demand, environmental concerns, and monopolistic marketplace conditions has spurred interest in boosting the domestic REE production from sources such as coal utilization byproducts. The economic viability of this approach requires rapid, inexpensive, and sensitive analytical techniques capable of characterizing the REE content during resource exploration and downstream REE processing (e.g., analyzing REE separation, concentration, and purification production steps). Luminescence-based sensors are attractive because many REEs may be sensitized to produce element-specific emission. Hence, a single material may simultaneously detect and distinguish multiple REEs. Metal–organic frameworks (MOFs) can sensitize multiple REEs, but their viability has been hindered by sensitivity and selectivity challenges. Understanding how the MOF structure impacts the REE sensing efficacy is critical to the rational design of new sensors. Here, we evaluate the sensing performance of seven different anionic zinc-adeninate MOFs with different organic linkers and/or structures for the visible-emitting REEs Tb, Dy, Sm, and Eu. The choice of a linker determines which REEs are sensitized and significantly influences their sensitivity and selectivity against competing species (here, Fe(II) and HCl). For a given linker, structural changes to the MOF can further fine-tune the performance. The MOFs produce some of the lowest detection limits (sub-10 ppb for Tb) reported for the aqueous sensitization-based REE detection. Importantly, the most selective MOFs demonstrated the ability to sensitize the REE signal at sub-ppm levels in a REE-spiked acid mine drainage matrix, highlighting their potential for use in real-world sensing applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS↗

On-Sky Performance of the SPT-3G Frequency-Domain Multiplexed Readout

Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition-edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme provides for the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current receiver on the South Pole Telescope, SPT-3G, uses a 68x fMux system to operate its large-format camera of ~16,000 TES bolometers. We present here the successful implementation and performance of the SPT-3G readout as measured on-sky. Characterization of the noise reveals a median pair-differenced 1/f knee frequency of 33 mHz, indicating that low-frequency noise in the readout will not limit SPT-3G’s measurements of sky power on large angular scales. Measurements further show that the median readout white noise level in each of the SPT-3G observing bands is below the expectation for photon noise, demonstrating that SPT-3G is operating in the photon-noise-dominated regime.

47 OTHER INSTRUMENTATION↗

Quasi-Distributed Fiber Sensor-Based Approach for Pipeline Health Monitoring: Generating and Analyzing Physics-Based Simulation Datasets for Classification

This study presents a framework for detecting mechanical damage in pipelines, focusing on generating simulated data and sampling to emulate distributed acoustic sensing (DAS) system responses. The workflow transforms simulated ultrasonic guided wave (UGW) responses into DAS or quasi-DAS system responses to create a physically robust dataset for pipeline event classification, including welds, clips, and corrosion defects. This investigation examines the effects of sensing systems and noise on classification performance, emphasizing the importance of selecting the appropriate sensing system for a specific application. The framework shows the robustness of different sensor number deployments to experimentally relevant noise levels, demonstrating its applicability in real-world scenarios where noise is present. Overall, this study contributes to the development of a more reliable and effective method for detecting mechanical damage to pipelines by emphasizing the generation and utilization of simulated DAS system responses for pipeline classification efforts. The results on the effects of sensing systems and noise on classification performance further enhance the robustness and reliability of the framework.

36 MATERIALS SCIENCE↗

Physically based correction of systematic errors of Rotating Shadowband Irradiometers

Accurate measurements of direct normal, diffuse horizontal and global horizontal irradiance (DNI, DHI and GHI) are needed for meteorological studies and are essential for the solar resource assessment at potential solar power plant sites. Often, these potential sites are remote and hence require robust sensors that require minimal maintenance that are not affected strongly by soiling. Therefore, Rotating Shadowband Irradiometers (RSI) are widely used for resource assessment. To achieve the required accuracy, corrections for the raw values of RSIs depending on systematic temperature, incidence angle and spectral errors must be used, and a thorough calibration of the sensor head must be applied. The existing correction functions are derived from comparisons of RSIs to thermopile radiometers at selected sites and therefore empirical. Their accuracy is considered to be site dependent. In this work a new correction and calibration method is presented that removes the systematic errors using a physical approach. It is based on information of the sensor properties as well as measurements of its directional response, and incorporates the atmospheric conditions at the measurement site. In this case, no empiric relations obtained from a specific site are required. The method requires estimates of the current DHI and GHI spectra during each measurement of the RSI. Based on these spectra, a spectral correction, which includes a spectrum dependent temperature correction, can be made without employing empirical relationships. The new physical calibration and correction method is tested at three sites and reaches similar results compared to the empirical functions. This is already achieved with rudimentary estimations of the GHI and DHI spectra and we expect that these estimations can be improved in the future. The results indicate that the physical approach reduces the problematic location dependence of the current calibration and correction methods. The physical correction and calibration method show promise for a further improvement of the RSI accuracy.

47 OTHER INSTRUMENTATION↗

High-performance silicon photonic single-sideband modulators for cold-atom interferometry

The laser system is the most complex component of a light-pulse atom interferometer (LPAI), controlling frequencies and intensities of multiple laser beams to configure quantum gravity and inertial sensors. Its main functions include cold-atom generation, state preparation, state-selective detection, and generating a coherent two-photon process for the light-pulse sequence. To achieve substantial miniaturization and ruggedization, we integrate key laser system functions onto a photonic integrated circuit. Our study focuses on a high-performance silicon photonic suppressed-carrier single-sideband (SC-SSB) modulator at 1560 nanometers, capable of dynamic frequency shifting within the LPAI. By independently controlling radio frequency (RF) channels, we achieve 30-decibel carrier suppression and unprecedented 47.8-decibel sideband suppression at peak conversion efficiency of –6.846 decibels (20.7%). We investigate imbalances in both amplitudes and phases between the RF signals. Using this modulator, we demonstrate cold-atom generation, state-selective detection, and atom interferometer fringes to estimate gravitational acceleration, g ≈ 9.77 ± 0.01 meters per second squared, in a rubidium ( 87 Rb) atom system.

47 OTHER INSTRUMENTATION↗

Fossil Power Plant Cyber Security Life-Cycle Risk Reduction, A Practical Framework for Implementation

Market conditions are forcing fossil electricity generation facility owners and operators to implement advanced digital technologies. These technologies enable efficiencies, operational flexibility, operations and maintenance efficiencies, and adapting to a transitioning workforce. These digital technologies, however, can increase the cybersecurity attack surface. The purpose of this research was to develop a holistic cybersecurity risk reduction framework for fossil generation facilities. The framework begins with assessing how cyber risk changes across facility life cycles, including plant, system, vendor, and business life cycles. The next phase performs consequence analysis to prioritize high consequence events. Focusing on high consequence events allows owners to use a graded, risk-informed approach to prioritize cybersecurity efforts. The final phase identifies the digital asset attack surface in sensors and instrumentation and control equipment. After the vulnerabilities are identified, the owner selects mitigating cybersecurity control measures (or countermeasures) based on the risk analysis from the previous phases. This report describes the current industry cybersecurity best practices in fossil generation that are based on the first principles for cybersecurity engineering. The report is divided into five sections that describe the implementation of the risk reduction framework and present identified research, methodological, and technology gaps that were identified through this course of research and development.

01 COAL, LIGNITE, AND PEAT↗

Temperature and water vapor mixing ratio profiles retrieved from the MWR

The purpose of this study was to look at the thermodynamic and microphysical evolution the atmosphere during fog events at Summit. These cases were selected due to the presence of fog during a period when additional aerosol sensors where deployed on the colocated tower.

54 ENVIRONMENTAL SCIENCES↗

Fossil Power Plant Cyber Security Life-Cycle Risk Reduction: A Practical Framework for Implementation

Market conditions are forcing fossil electricity generation facility owners and operators to implement advanced digital technologies. These technologies enable efficiencies, operational flexibility, operations and maintenance efficiencies, and adapting to a transitioning workforce. These digital technologies, however, can increase the cybersecurity attack surface. The purpose of this research was to develop a holistic cybersecurity risk reduction framework for fossil generation facilities. The framework begins with assessing how cyber risk changes across facility life cycles, including plant, system, vendor, and business life cycles. The next phase performs consequence analysis to prioritize high consequence events. Focusing on high consequence events allows owners to use a graded, risk-informed approach to prioritize cybersecurity efforts. The final phase identifies the digital asset attack surface in sensors and instrumentation and control equipment. After the vulnerabilities are identified, the owner selects mitigating cybersecurity control measures (or countermeasures) based on the risk analysis from the previous phases. This report describes the current industry cybersecurity best practices in fossil generation that are based on the first principles for cybersecurity engineering. The report is divided into five sections that describe the implementation of the risk reduction framework and present identified research, methodological, and technology gaps that were identified through this course of research and development.

20 FOSSIL-FUELED POWER PLANTS↗

Fossil Power Plant Cyber Security Life-Cycle Risk Reduction: A Practical Framework for Implementation

Market conditions are forcing fossil electricity generation facility owners and operators to implement advanced digital technologies. These technologies enable efficiencies, operational flexibility, operations and maintenance efficiencies, and adapting to a transitioning workforce. These digital technologies, however, can increase the cybersecurity attack surface. The purpose of this research was to develop a holistic cybersecurity risk reduction framework for fossil generation facilities. The framework begins with assessing how cyber risk changes across facility life cycles, including plant, system, vendor, and business life cycles. The next phase performs consequence analysis to prioritize high consequence events. Focusing on high consequence events allows owners to use a graded, risk-informed approach to prioritize cybersecurity efforts. The final phase identifies the digital asset attack surface in sensors and instrumentation and control equipment. After the vulnerabilities are identified, the owner selects mitigating cybersecurity control measures (or countermeasures) based on the risk analysis from the previous phases. This report describes the current industry cybersecurity best practices in fossil generation that are based on the first principles for cybersecurity engineering. The report is divided into five sections that describe the implementation of the risk reduction framework and present identified research, methodological, and technology gaps that were identified through this course of research and development.

20 FOSSIL-FUELED POWER PLANTS↗

A Chimeric LBT-GFP Biosensor Exhibits Antithetical Fluorescence Responses to Ca 2+ and Dy 3+ Binding

Rare earth elements (REEs) are critical components in emerging technologies, but their mining and refining processes are often laborious, costly, and environmentally damaging. Developing green and efficient separation methods for REEs is crucial. Biomolecular approaches using lanthanide-binding proteins and peptides show promise for selective REE extraction and separation. In this study, we present the design and characterization of a genetically encoded fluorescence indicator (GEFI) construct that combines a superfolder green fluorescent protein (sfGFP) with a dual lanthanide-binding tag (2×dLBT). The 2×dLBT insert induces conformational changes in sfGFP upon lanthanide binding, modulating the fluorescence intensity. The sfGFP-2×dLBT biosensor exhibited distinct fluorescence responses to different lanthanide ions, with the highest dynamic range observed for heavy REEs like dysprosium (Dy 3+ ). Interestingly, the sensor displayed an antithetical response, where low concentrations of lanthanides initially quenched the fluorescence, but higher concentrations led to a significant fluorescence increase (1.5-fold). The Ca 2+ ion on the other hand showed only a dose-dependent quenching of the fluorescence response. Based on these observations, the biphasic response of the biosensor to lanthanides was eliminated by pretreating the sensor with calcium, which further expanded the dynamic range up to 3-fold for Dy 3+ . The lanthanide-selective and concentration-dependent fluorescence changes of the sfGFP-2×dLBT biosensor demonstrate its potential as a platform for developing specific sensors for various REEs. These sensors could enable rapid and cost-effective determination of REE composition in complex mixtures, facilitating the separation and recovery of critical REEs from electronic waste and other REE-containing sources.

59 BASIC BIOLOGICAL SCIENCES↗

Embedding Sensors in 3D Printed Metal Structures

The Transformational Challenge Reactor (TCR) program is leveraging recent advances in modeling and simulation, materials, and additive manufacturing (AM) technologies to design a modern nuclear reactor. Some of the main TCR technologies include in situ monitoring and the integration of sensors during the manufacturing of quality-significant nuclear reactor components. This report describes the general procedure and process optimization for embedding sensors within generic stainless steel 316 (SS316) components using laser powder bed fusion (LPBF). A more detailed, quality-significant test plan and supporting procedures are available upon request (ORNL/TM-2021/2127). LPBF involves the use of a scanning laser to selectively melt regions of a powder bed, additively building a part layer by layer. This report describes the LPBF processing technique and discusses the effects of LPBF processing parameters on the success of the sensor embedding process. Experiments used machined cavities in the form of channels in an SS316 base for the sensors to lay in while material is additively built over the top, thereby embedding them in an SS316 matrix. A preliminary investigation involved using empty SS316 sheaths as surrogates to explore the effects of various LPBF processing parameters and the dimensional requirements of the machined channels. Microstructural investigations showed that a smaller channel width/depth combination closer to the sensor’s diameter was best for the embedding process. After the desired parameters were selected, Type-K thermocouples were embedded and evaluated post-embedding using nondestructive thermal testing, as well as destructive sectioning and microscopy. Post-build characterization showed that the thermocouples were well-bonded to the SS316 matrix and were fully functional after embedding. During thermal testing to temperatures up to 500 °C, the embedded thermocouples read consistently with one another and deviated only slightly from the readings of a nonembedded thermocouple located within the furnace. This slight discrepancy was most likely due to differences in the thermal time constants for a nonembedded thermocouple vs. a thermocouple embedded in a solid SS316 block. The results presented in this report will serve as the foundation for future work that will focus on embedding sensors in relevant TCR reactor components and eventually testing those components under neutron irradiation.

36 MATERIALS SCIENCE↗

Enzymatic Laser-Induced Graphene Biosensor for Electrochemical Sensing of the Herbicide Glyphosate

Glyphosate is a globally applied herbicide yet it has been relatively undetectable in-field samples outside of gold-standard techniques. Its presumed nontoxicity toward humans has been contested by the International Agency for Research on Cancer, while it has been detected in farmers’ urine, surface waters and crop residues. Rapid, on-site detection of glyphosate is hindered by lack of field-deployable and easy-to-use sensors that circumvent sample transportation to limited laboratories that possess the equipment needed for detection. Herein, the flavoenzyme, glycine oxidase, immobilized on platinum-decorated laser-induced graphene (LIG) is used for selective detection of glyphosate as it is a substrate for GlyOx. The LIG platform provides a scaffold for enzyme attachment while maintaining the electronic and surface properties of graphene. The sensor exhibits a linear range of 10–260 µm, detection limit of 3.03 µm, and sensitivity of 0.991 nA µm -1 . The sensor shows minimal interference from the commonly used herbicides and insecticides: atrazine, 2,4-dichlorophenoxyacetic acid, dicamba, parathion-methyl, paraoxon-methyl, malathion, chlorpyrifos, thiamethoxam, clothianidin, and imidacloprid. Sensor function is further tested in complex river water and crop residue fluids, which validate this platform as a scalable, direct-write, and selective method of glyphosate detection for herbicide mapping and food analysis.

47 OTHER INSTRUMENTATION↗

Improved Bayesian regularization of inverse problems in vibrations and acoustics using noise-only measurements

Here, this paper studies Tikhonov regularization (ridge regression) parameter selection for problems in vibrations and acoustics. The selection method is based on a popular Bayesian method, but it incorporates measurements of sensor noise. The regularization parameter is closely related to the ratio of system input energy to noise energy, so noise measurements inform the inference procedure and improve parameter identification. In cases where standard Bayesian regularization identifies zero as the optimal regularization parameter, noise measurements guarantee a unique nonzero optimum. Sufficient theoretical criteria are developed for this guarantee. The method is verified in even-determined and under-determined configurations in an acoustic source localization simulation and a vibration load identification experiment. It is shown to yield significant improvements over existing empirical Bayesian regularization. Improvements are larger in the even-determined case and smaller in the under-determined case, wherein the inverse solution is less sensitive to the regularization parameter.

42 ENGINEERING↗

Understanding the Influence of Urban Form on the Spatial Pattern of Precipitation

Urban areas are known to modify the spatial pattern of precipitation climatology. Existing observational evidence suggests that precipitation can be enhanced downwind of a city. Among the proposed mechanisms, the thermodynamic and aerodynamic processes in the urban lower atmosphere interact with the meteorological conditions and can play a key role in determining the resulting precipitation patterns. In addition, these processes are influenced by urban form, such as the impervious surface extent. This study aims to unravel how different urban forms impact the spatial patterns of precipitation climatology under different meteorological conditions. We use the Multi-Radar Multi-Sensor quantitative precipitation estimation data products and analyze the hourly precipitation maps for 27 selected cities across the continental United States from the years 2015–2021 summer months. Results show that about 80% of the studied cities exhibit a statistically significant downwind enhancement of precipitation. Additionally, we find that the precipitation pattern tends to be more spatially clustered in intensity under higher wind speed; the location of radial precipitation maxima is located closer to the city center under low background winds but shifts downwind under high wind conditions. The magnitude of downwind precipitation enhancement is highly dependent on wind directions and is positively correlated with the city size for the south, southwest, and west directions. This study presents observational evidence through a cross-city analysis that the urban precipitation pattern can be influenced by the urban modification of atmospheric processes, providing insight into the mechanistic link between future urban land-use change and hydroclimates.

54 ENVIRONMENTAL SCIENCES↗

Tri-molybdenum phosphide (Mo 3 P) and multi-walled carbon nanotube junctions for volatile organic compounds (VOCs) detection

Detection and analysis of volatile organic compounds' (VOCs) biomarkers lead to improvement in healthcare diagnosis and other applications such as chemical threat detection and food quality control. Here, we report on tri-molybdenum phosphide (Mo3P) and multiwalled carbon nanotube (MWCNT) junction-based vapor quantum resistive sensors (vQRSs), which exhibit more than one order of magnitude higher sensitivity and superior selectivity for biomarkers in comparison to pristine MWCNT junctions based vQRSs. Transmission electron microscope/scanning tunneling electron microscope with energy dispersive x-ray spectroscopy, x-ray diffraction, and x-ray photoelectron spectroscopy studies reveal the crystallinity and the presence of Mo and P elements in the network. The presence of Mo3P clearly enhanced the performance of vQRS as evidenced in sensitivity and selectivity studies. The vQRSs are stable over extended periods of time and are reproducible, making them a potential candidate for sensing related applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗