Pioneer Venus - Evolving coverage of the near-Venus environment

The manner in which secular changes in the orbit of the Pioneer Venus Orbiter (PVO) research satellite influence its data collecting capabilities is discussed. A brief description of the propulsion system and sensor arrays of the satellite is presented, and the susceptibility of these systems to changes in power supply due to the decline in solar activity is considered. It is pointed out that the PVO should have enough fuel to continue to transmit data until after the arrival of Comet Halley in 1986, and that, during the 1991 to 1992 period, more moderate levels of solar activity will permit more accurate measurements of thermospheric and ionospheric parameters.

Brace, L. H.↗

Cartographic potential of SPOT image data

In late 1985, the SPOT (Systeme Probatoire d'Observation de la Terre) satellite is to be launched by the Ariane rocket from French Guiana. This satellite will have two High Resolution Visible (HRV) line array sensor systems which are capable of providing monoscopic and stereoscopic coverage of the earth. Cartographic applications are related to the recording of stereo image data and the acquisition of 20-m data in a multispectral mode. One of the objectives of this study involves a comparison of the suitability of SPOT and TM image data for mapping urban land use/cover. Another objective is concerned with a preliminary assessment of the potential of SPOT image data for map revision when merged with conventional map sheets converted to raster formats.

Welch, R.↗

Airborne atmospheric electricity experiments

During the 1984 U2 spring flight program, lightning spectra were measured in the wavelengths from 380 nm to 900 nm with a temporal resolution of 5 ms. With this capability, researchers simultaneously acquired both visible near-infrared lightning spectra on a pulse to pulse basis, so that the spectral variability within a flash, as well as flash to flash variations, can be studied. Preliminary results suggest that important variations do occur, particularly in the strengths of the hydrogen and singly ionized nitrogen emission lines. Also, the results have revealed significant differences in the integrated energy distributions between the lightning spectra measured above clouds and the spectral measurements of cloud-to-ground lightning made at the ground. In particular, the ratio of the energy in the near-IR to that in the visible is around 1 to 2 for cloud top spectra versus about 1/3 for surface observations. Detailed analyses of the 1984 lightning spectral data is being conducted. This data should provide improved understanding about the optical transmission properties of thunderclouds and the physics of the lightning discharge process. Efforts continue on developing and testing background signal removal algorithms using U2 spectometer and optical array sensor day-flight data sets. The goal of this research is to develop an algorithm satisfying Lightning Mapper Sensor requirements.

Blakeslee, R. J.↗

Welding torch with arc light reflector

A welding torch arc light reflector is disclosed for welding torches having optical viewing systems. A schematic of a welding torch having an internal coaxial viewing system consisting of a lens which focuses the field of view of the weld scene of the workpiece onto the end of the fiberoptic bundle is provided. The transmitted image of the fiberoptic bundle is provided to a camera lens which focuses it onto a TV sensor array for transmission. To improve the parity of the image of the monitoring system, an arc light reflector is shown fitted to the end of the torch housing or gas cup. The arc light reflector has an internal conical section portion which is polished to serve as a mirror which reflects the bright arc light back onto the darker areas of the weld area and thereby provides a more detailed image for the monitoring system. The novelty of the invention lies in the use of an arc light reflector on welding torches having optical viewing systems.

Gordon, Stephen S.↗

Optical strain measurement system development, phase 1

A laser speckle, differential strain measurement system was built and tested for future applications in hostile environments. One dimensional electronic correlation of speckle pattern movement allows a quasi-real time measure of strain. The system was used successfully to measure uniaxial strain reaching into plastic deformation of a test specimen, at temperatures ranging to 450 C. A resolution of 16 microstrain is given by the photodiode array sensor pitch and the specimen to sensor separation. The strain measurement limit of the gauge is determined by air density perturbations causing decorrelation of the reference and shifted speckle patterns, and may be improved by limiting convective flow in the immediate vicinity of the test specimen.

Lant, Christian T.↗

Optical strain measurement system development

A laser speckle, differential strain measurement system has been built and tested for future applications in hostile environments. One-dimensional electronic correlation of speckle pattern movement allows a quasi-real time measure of strain. The system has been used successfully to measure uniaxial strain reaching into plastic deformation of a test specimen, at temperatures ranging to 450 C. A resolution of 16 microstrain is given by the photodiode array sensor pitch and the specimen to sensor separation. The strain measurement error is estimated to be +/-18 microstrain +/-3 percent of the strain reading. The upper temperature limit of the gauge is determined by air density perturbations causing decorrelation of the reference and shifted speckle patterns, and may be improved by limiting convective flow in the immediate vicinity of the test specimen.

Lant, Christian T.↗

A unique measurement technique to study laminar-separation bubble characteristics on an airfoil

A 'nonintrusive', multielement heat-transfer sensor was designed to study laminar-separation bubble characteristics on a NASA LRN (1)-1010 low-Reynolds number airfoil. The sensor consists of 30 individual nickel films, vacuum-deposited on a thin substrate (0.05 mm) that was bonded to the airfoil model with the sensor array placed streamwise on the airfoil upper surface. Experiments were conducted on a 15-cm chord model in the 50,000-300,000 chord Reynolds number range. Time history as well as spectral analysis of signals from surface film gauges were simultaneously obtained to determine the location of laminar separation and the subsequent behavior of the separated shear layer. In addition to the successful determination of laminar separation, a new phenomenon involving a large phase shift in dynamic shear stresses across the separation and reattachment points was observed.

Stack, J. P.↗

Simplified Microwave Radiometer

Cost, weight, and size less than half of conventional radiometers. Ground-based instrument measures temperatures in upper atmosphere while correcting for liquid water in clouds. Addition of channel at 51 GHz to channels used for making upper-atmosphere temperature profiles adds little to cost of microwave radiometer. Eliminates need for separate water-vapor radiometer subsystem, with its attendant size, weight, and cost. Instrument light, compact, and portable and inexpensive enough for use in sensor arrays. Availability encourages use of microwave radiometry for routine weather forecasting.

Gary, Bruce L.↗

Optical strain measurement system development

A laser speckle, differential strain measurement system has been built and tested for future applications in hostile environments. One-dimensional electronic correlation of speckle pattern movement allows a quasi-real time measure of strain. The system has been used successfully to measure uniaxial strain reaching into plastic deformation of a test specimen, at temperatures ranging to 450 C. A resolution of 126 microstrain is given by the photodiode array sensor pitch and the specimen to sensor separation. The strain measurement error is estimated to be +/-18 microstrain +/-3 percent of the strain reading. The upper temperature limit of the gauge is determined by air density perturbations causing decorrelation of the reference and shifted speckle patterns, and may be improved by limiting convective flow in the immediate vicinity of the test specimen.

Lant, Christian T.↗

The experiments of LIPS 3

LIPS 3 is a member of the Living Plume Shield series of spacecraft. In each LIPS project, the plume shield, a simple sheet metal cone, was structurally stiffened, and an active satellite was then built around it. The original purpose of the plume shield was to prevent the plume from solid propellent engines, which are fired outside the atmosphere after the aerodynamic shroud is jettisoned, from reaching the primary payload. The surface of LIPS 3 facing the plume also functioned in this manner, but the anterior surfaces were unaffected, and it was there that all solar arrays, sensors, and experiments were mounted. The purpose of LIPS 3 was to provide a test bed for new space power sources. With the long delays projected for schedules of the STS and other major launch systems, it appeared that a decade might pass before long term flight data could be obtained on many new and innovative power sources. The fact that a launch scheduled for early in 1987 required a plume shield was seen as a unique opportunity to obtain some of this data in a timely manner. The LIPS 3 system, the experiments placed aboard, and the experiment data acquisition subsystem are described. Various problems were encountered during integration and after launch; those which appear to effect the accuracy of experimental results are discussed. A preliminary description is given of the accuracy of the flight experiment data.

Severns, J. G.↗

Digital and optical shape representation and pattern recognition; Proceedings of the Meeting, Orlando, FL, Apr. 4-6, 1988

The present conference discusses topics in pattern-recognition correlator architectures, digital stereo systems, geometric image transformations and their applications, topics in pattern recognition, filter algorithms, object detection and classification, shape representation techniques, and model-based object recognition methods. Attention is given to edge-enhancement preprocessing using liquid crystal TVs, massively-parallel optical data base management, three-dimensional sensing with polar exponential sensor arrays, the optical processing of imaging spectrometer data, hybrid associative memories and metric data models, the representation of shape primitives in neural networks, and the Monte Carlo estimation of moment invariants for pattern recognition.

Juday, Richard D.↗

A new multipoint thin-film diagnostic technique for fluid dynamic studies

A multielement hot-film sensor has been developed with closely-spaced elements (2.5 mm) in the streamwise direction. In addition to boundary-layer transition detection, the output of these sensors can reveal the locations of boundary-layer separation and reattachment by a 180 deg phase difference in the 0-200-Hz frequency bandwidth between sensor elements on each side of either the separation or reattachment point. This paper describes the features of multielement hot-film sensor arrays and discusses results from their application to a number of low-speed and transonic airfoil tests.

Sewall, W. G.↗

Linear digital imaging system fidelity analysis

The combined effects of imaging gathering, sampling and reconstruction are analyzed in terms of image fidelity. The analysis is based upon a standard end-to-end linear system model which is sufficiently general so that the results apply to most line-scan and sensor-array imaging systems. Shift-variant sampling effects are accounted for with an expected value analysis based upon the use of a fixed deterministic input scene which is randomly shifted (mathematically) relative to the sampling grid. This random sample-scene phase approach has been used successfully by the author and associates in several previous related papers.

Park, Stephen K.↗

Image gathering, coding, and processing: End-to-end optimization for efficient and robust acquisition of visual information

Researchers are concerned with the end-to-end performance of image gathering, coding, and processing. The applications range from high-resolution television to vision-based robotics, wherever the resolution, efficiency and robustness of visual information acquisition and processing are critical. For the presentation at this workshop, it is convenient to divide research activities into the following two overlapping areas: The first is the development of focal-plane processing techniques and technology to effectively combine image gathering with coding, with an emphasis on low-level vision processing akin to the retinal processing in human vision. The approach includes the familiar Laplacian pyramid, the new intensity-dependent spatial summation, and parallel sensing/processing networks. Three-dimensional image gathering is attained by combining laser ranging with sensor-array imaging. The second is the rigorous extension of information theory and optimal filtering to visual information acquisition and processing. The goal is to provide a comprehensive methodology for quantitatively assessing the end-to-end performance of image gathering, coding, and processing.

Huck, Friedrich O.↗

Feasibility study for the advanced one-dimensional high temperature optical strain measurement system, phase 3

The Instrumentation and Control Technology Division is developing optical strain measurement systems for applications using high temperature wire and fiber specimens. This feasibility study has determined that stable optical signals can be obtained from specimens at temperatures beyond 2,400 C. A system using an area array sensor is proposed to alleviate off-axis decorrelation arising from rigid body motions. A digital signal processor (DSP) is recommended to perform speckle correlations at a rate near the data acquisition rate. Design parameters are discussed, and fundamental limits on the speckle shift strain measurement technique are defined.

Lant, Christian T.↗

An experimental investigation of fault tolerant software structures in an avionics application

The objective of this experimental investigation is to compare the functional performance and software reliability of competing fault tolerant software structures utilizing software diversity. In this experiment, three versions of the redundancy management software for a skewed sensor array have been developed using three diverse failure detection and isolation algorithms and incorporated into various N-version, recovery block and hybrid software structures. The empirical results show that, for maximum functional performance improvement in the selected application domain, the results of diverse algorithms should be voted before being processed by multiple versions without enforced diversity. Results also suggest that when the reliability gain with an N-version structure is modest, recovery block structures are more feasible since higher reliability can be obtained using an acceptance check with a modest reliability.

Caglayan, Alper K.↗

Instrumentation for near-Earth measurement of orbital debris and cosmic dust particles

Dust instrumentation based on polyvinylidene fluoride (PVDF) dust sensor arrays is described which will measure the masses, fluxes, velocities, and trajectories of orbital debris particles and natural micrometeoroids. Orbital debris particles are distinguished from natural particles (cosmic dust) by means of the velocity/trajectory information. The instrumentation will measure particle trajectory with a mean error of approximately 7 degrees (for isotropic flux) and is designed for measurements over the particle diameter range of approximately 2 to 200 micro-m. For future missions having Earth-return capabilities, arrays of capture cell devices positioned behind the PVDF trajectory system would provide for Earth-based chemical and isotopic analysis of captured dust.

Tuzzolino, Anthony J.↗

Advanced one-dimensional optical strain measurement system, phase 4

An improved version of the speckle-shift strain measurement system was developed. The system uses a two-dimensional sensor array to maintain speckle correlation in the presence of large off-axis rigid body motions. A digital signal processor (DSP) is used to calculate strains at a rate near the RS-170 camera frame rate. Strain measurements were demonstrated on small diameter wires and fibers used in composite materials research. Accurate values of Young's modulus were measured on tungsten wires, and silicon carbide and sapphire fibers. This optical technique has measured surface strains at specimen temperatures above 750 C and has shown the potential for measurements at much higher temperatures.

Lant, Christian T.↗