Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Corrections for the effects of significant wave height and attitude on Geosat radar altimeter measurements

Range estimates from a radar altimeter have biases which are a function of the significant wave height (SWH) and the satellite attitude angle (AA). Based on results of prelaunch Geosat modeling and simulation, a correction for SWH and AA was already applied to the sea-surface height estimates from Geosat's production data processing. By fitting a detailed model radar return waveform to Geosat waveform sampler data, it is possible to provide independent estimates of the height bias, the SWH, and the AA. The waveform fitting has been carried out for 10-sec averages of Geosat waveform sampler data over a wide range of SWH and AA values. The results confirm that Geosat sea-surface-height correction is good to well within the original dm-level specification, but that an additional height correction can be made at the level of several cm.

Hayne, G. S.↗

Comet nucleus and asteroid sample return missions

During the 1991-92 academic year, the Pennsylvania State University has developed three sample return missions: one to the nucleus of comet Wild 2, one to the asteroid Eros, and one to three asteroids located in the Main Belt. The primary objective of the comet nucleus sample return mission is to rendezvous with a short period comet and acquire a 10 kg sample for return to Earth. Upon rendezvous with the comet, a tethered coring and sampler drill will contact the surface and extract a two-meter core sample from the target site. Before the spacecraft returns to Earth, a monitoring penetrator containing scientific instruments will be deployed for gathering long-term data about the comet. A single asteroid sample return mission to the asteroid 433 Eros (chosen for proximity and launch opportunities) will extract a sample from the asteroid surface for return to Earth. To limit overall mission cost, most of the mission design uses current technologies, except the sampler drill design. The multiple asteroid sample return mission could best be characterized through its use of future technology including an optical communications system, a nuclear power reactor, and a low-thrust propulsion system. A low-thrust trajectory optimization code (QuickTop 2) obtained from the NASA LeRC helped in planning the size of major subsystem components, as well as the trajectory between targets.

Melton, Robert G.↗

Scales of variability of bio-optical properties as observed from near-surface drifters

A drifter equipped with bio-optical sensors and an automated water sampler was deployed in the California Current as part of the coastal transition zone program to study the biological, chemical, and physical dynamics of the meandering filaments. During deployments in 1987 and 1988, measurements were made of fluorescence, downwelling irradiance, upwelling radiance, and beam attenuation using several bio-optical sensors. Samples were collected by an automated sampler for later analysis of nutrients and phytoplankton species compositon. Large-scale spatial and temporal changes in the bio-optical and biological properties of the region were driven by changes in phytoplankton species composition which, in turn, were associated with the meandering circulation. Variance spectra of the bio-optical paramenters revealed fluctuations on both diel and semidiurnal scales, perhaps associated with solar variations and internal tides, respectively. Offshore, inertial-scale fluctuations were apparent in the variance spectra of temperature, fluorescence, and beam attenuation. Although calibration samples can help remove some of these variations, these results suggest that the use of bio-optical data from unattended platforms such as moorings and drifters must be analyzed carefully. Characterization of the scaled of phytoplankton variability must account for the scales of variability in the algorithms used to convert bio-optical measurments into biological quantities.

Abbott, Mark R.↗

Life in Extreme Environments Research #2

The goal of this project was to collect suspended particles and microbes for spectral analysis from deep water around hydrothermal vent study sites on the Juan de Fuca Ridge. To accomplish this, the McLane WTS 6-24-47 Sampler (McLane Research Laboratories, Falmouth, MA) was used. The WTS sampler is a programmable unit which is able to collect individual samples across twenty-four 47mm diameter filters at predetermined intervals and duration. Although only one successful deployment was needed, a maximum of three 3 deployments were possible (deployment opportunities were limited by the number of battery packs available). The initial behavior of the WTS and the ship's schedule both indicated that three deployments would be possible. However, it was revealed upon recovery after the first deployment that the WTS failed as it was preparing to collect its first sample.

Fisher, Charles R.↗

Intercomparisons of Airborne Measurements of Aerosol Ionic Chemical Composition during TRACE-P and ACE-Asia

As part of the two field studies, Transport and Chemical Evolution over the Pacific (TRACE-P), and the Asian Aerosol Characterization Experiment (ACEAsia), the inorganic chemical composition of tropospheric aerosols was measured over the western Pacific from three separate aircraft using various methods. Comparisons are made between the rapid online techniques of the Particle Into Liquid Sampler (PILS) for measurement of a suite of fine particle ionic compounds and a mist chamber (MC/IC) measurement of fine sulfate, and the longer time-integrated filter and multi-orifice impactor (MOI) measurements. Comparisons between identical PILS on two separate aircraft flying in formation showed that they were highly correlated (e.g., sulfate r(sup 2) of 0.95), but were systematically different by 10 +/- 5% (linear regression slope and 95% confidence bounds), and had generally higher concentrations on the aircraft with a low turbulence inlet and shorter inlet-to-instrument transmission tubing. Comparisons of PILS and mist chamber measurements of fine sulfate on two different aircraft during formation flying had an 3 of 0.78 and a relative difference of 39% +/- 5%. MOI ionic data integrated to the PILS upper measurement size of 1.3 pm sampling from separate inlets on the same aircraft showed that for sulfate, PILS and MOI were within 14% +/- 6% and correlated with an r(sup 2) of 0.87. Most ionic compounds were within f 30%, which is in the range of differences reported between PILS and integrated samplers from ground-based comparisons. In many cases, direct intercomparison between the various instruments is difficult due to differences in upper-size detection limits. However, for this study, the results suggest that the fine particle mass composition measured from aircraft agree to within 30-40%.

Ma, Y.↗

Quick-Connect Windowed Non-Stick Penetrator Tips for Rapid Sampling

Standard penetrator sampling systems were designed in order to allow for sampling via penetrators to produce a full set of sample acquisitions including volatile liquids, fine powders, and solid fragments. A gravity harpoon sampler has been designed with a removable tip and a quick coupling. The separation allows for sample handling and eliminates sample cross-contamination. Also, this design allows for multiple use of the penetrator body, which is the largest and heaviest part of the penetrator, while allowing for multiple changes of the light-mass, penetrator tip to avoid sample cross-contamination. The penetrator tip design has been improved by adding a spring trap to retain the sample, as well as a means for connecting to a quick coupling. Quick connect tips have been demonstrated in a sample handling carousel. The penetrator was released and rewound and the tips were released into a circular platter for rotation into instrument stations. The pyro-harpoon sampler was fabricated and tested with a NASA Standard Initiator (NSI) pyrotechnic charge. Initial tests collected cryogenic ice, but removal of the small pyro-harpoon from the ice was difficult. A brass metal sheath was then fitted over the harpoon tip, and removal from the ice was greatly alleviated by leaving the sheath in the ice. Quartz windows in the tips allow direct optical and spectral imaging and gas chromatography-mass spectrometer (GCMS) pyrolysis, and were found to survive impact. All systems were successfully tested by dropping into sand and into cryogenic ice.

Sherritt, Stewart↗

Surface Contact Model for Comets and Asteroids

A contact force model was developed for use in touch and go (TAG) surface sampling simulations on small celestial bodies such as comets and asteroids. In TAG scenarios, a spacecraft descending toward the surface of a small body comes into contact with the surface for a short duration of time, collects material samples with a sampler device, and then ascends to leave the surface. The surface contact required 6-DOF (degrees of freedom) dynamics models due to coupling of the attitude and translation dynamics during the contact. The model described here is for contact scenarios that utilize a rotating brush wheel sampler (BWS) to collect surface material. The model includes stiffness and damping of the surface material during BWS vertical motion, lateral friction from the BWS dragging across the surface, and lateral shear from the rotating BWS scooping the surface material. This model is useful for any mission to asteroids or comets that incorporates surface sampling operations.

Blackmore, Lars James C.↗

Connect Global Positioning System RF Module

The CoNNeCT Global Positioning System RF Module (GPSM) slice is part of the JPL CoNNeCT Software Defined Radio (SDR). CoNNeCT is the Communications, Navigation, and Net working reconfigurable Testbed project that is part of NASA's Space Communication and Nav igation (SCaN) Program. The CoNNeCT project is an experimental dem onstration that will lead to the advancement of SDRs and provide a path for new space communication and navigation systems for future NASA exploration missions. The JPL CoNNeCT SDR will be flying on the International Space Station (ISS) in 2012 in support of the SCaN CoNNeCT program. The GPSM is a radio-frequency sampler module (see Figure 1) that directly sub-harmonically samples the filtered GPS L-band signals at L1 (1575.42 MHz), L2 (1227.6 MHz), and L5 (1176.45 MHz). The JPL SDR receives GPS signals through a Dorne & Margolin antenna mounted onto a choke ring. The GPS signal is filtered against interference, amplified, split, and fed into three channels: L1, L2, and L5. In each of the L-band channels, there is a chain of bandpass filters and amplifiers, and the signal is fed through each of these channels to where the GPSM performs a one-bit analog-to-digital conversion (see Figure 2). The GPSM uses a sub-harmonic, single-bit L1, L2, and L5 sampler that samples at a clock rate of 38.656 MHz. The new capability is the down-conversion and sampling of the L5 signal when previous hardware did not provide this capability. The first GPS IIF Satellite was launched in 2010, providing the new L5 signal. With the JPL SDR flying on the ISS, it will be possible to demonstrate navigation solutions with 10-meter 3-D accuracy at 10-second intervals using a field-program mable gate array (FPGA)-based feedback loop running at 50 Hz. The GPS data bits will be decoded and used in the SDR. The GPSM will also allow other waveforms that are installed in the SDR to demonstrate various GNSS tracking techniques.

Franklin, Garth W.↗

Analysis of the Touch-And-Go Surface Sampling Concept for Comet Sample Return Missions

This paper studies the Touch-and-Go (TAG) concept for enabling a spacecraft to take a sample from the surface of a small primitive body, such as an asteroid or comet. The idea behind the TAG concept is to let the spacecraft descend to the surface, make contact with the surface for several seconds, and then ascend to a safe location. Sampling would be accomplished by an end-effector that is active during the few seconds of surface contact. The TAG event is one of the most critical events in a primitive body sample-return mission. The purpose of this study is to evaluate the dynamic behavior of a representative spacecraft during the TAG event, i.e., immediately prior, during, and after surface contact of the sampler. The study evaluates the sample-collection performance of the proposed sampling end-effector, in this case a brushwheel sampler, while acquiring material from the surface during the contact. A main result of the study is a guidance and control (G&C) validation of the overall TAG concept, in addition to specific contributions to demonstrating the effectiveness of using nonlinear clutch mechanisms in the sampling arm joints, and increasing the length of the sampling arms to improve robustness.

Touch-and-Go (TAG)↗

Investigating the Present Day Cosmic Dust Flux at the Earth's Surface: Initial Results from the Kwajalein Micrometeorite Collection

Examination of impact craters on the Long Duration Exposure Facility satellite indicate a present day micrometeoroid flux of approx. 30,000 tonnes [1 after 2]. But what portion of this material arrives at the Earth's surface as micrometeorites? Studies of available micrometeorite collections from deep sea sediments [e.g. 3], Greenland blue ice [e.g. 4] and the South Pole water well [e.g. 1] may be complicated by terrestrial weathering and, in some cases, collection bias (magnetic separation for deep sea sediments) and poorly constrained ages. We have recently set up a micrometeorite collection station on Kwajalein Island in the Republic of the Marshall Islands in the Pacific Ocean, using high volume air samplers to collect particles directly from the atmosphere. By collecting in this way, the terrestrial age of the particles is known, the weathering they experience is minimal, and we are able to constrain particle arrival times. Collecting at this location also exploits the considerably reduced anthropogenic background [5]. Method: High volume air samplers were installed on top of the two-story airport building on Kwajalein. These were fitted with polycarbonate membrane filters with 5μm diameter perforations. The flow rates were set to 0.5m3/min, and filters were changed once a week. After collection, filters were washed to remove salt and concentrate particles [see 5] in preparation for analysis by SEM. Results and Discussion: A selection of filters have been prepared and surveyed. Due to their ease of identification our initial investigations have focused on particles resembling cosmic spherules. The spheres can be divided into three main groups: 1. Silicate spherules rich in Al, Ca, K and Na (to varying degrees), 2. Silicate spherules rich in Mg and Fe and 3. Fe-rich spherules. Group 1 spherules are often vesiculated and can occur as aggregates. They are similar in appearance and composition to volcanic microspheres [e.g. 6] and are thus likely terrestrial in origin (volcanic). Those of groups 2 and 3, however, typically exhibit quenched surface textures consistent with cosmic spherules. Initial results suggest there is significant variation in the abundance of these groups from filter to filter. Work is ongoing to fully characterize these spherules and to constrain their flux with time.

Wozniakiewicz, P. J.↗

Volatile Organic Compounds Emitted from Air Fresheners: Plug-Ins at Home and Little Trees in Cars

Air fresheners contain volatile organic compounds (VOCs), some of which are possible hazardous air pollutants, carcinogens, or chemicals associated with adverse health effects such as asthma. This screening study identifies VOCs emitted from two types of air fresheners. Plug-in air fresheners are household products that release scents from a heated liquid. Little Tree air fresheners are commonly used solid devices designed to hang in from the rear view mirror in cars. VOCs that were released from heated samples of air fresheners were identified by gas chromatography mass spectroscopy (GCMS). Amongst VOCs commonly known to have scent properties, this screening also revealed the presence of compounds that are not associated with fragrances and that may have adverse health effects. In a pilot study to characterize how air fresheners affect air quality in real settings, air samples were collected on solid-phase microextraction (SPME) field samplers in a home setting and inside a vehicle, before and during air-freshener use. This pilot demonstrated some limited potential for SPME field samplers to track changes in VOC levels in real-life settings.

Adriana Pino-Delgado↗

Single-Use Destructive Assay for Uranium Hexafluoride Sampling

Sampling uranium hexafluoride (UF6) for the determination of enrichments by destructive analysis (DA) is a critical component in the International Atomic Energy Agency’s layered safeguards approach for uranium processing facilities. Typically, gram-quantity UF6 samples are collected during inspections and stored under tag-and-seal until transportation to an off-site analytical laboratory. The shipping times can be long, and evolving restrictions on radioactive/corrosive materials shipments may increasingly limit the IAEA’s ability to transport UF6 samples easily. Pacific Northwest National Laboratory has developed a low-cost UF6 sampling technology called Single-Use Destructive Assay (SUDA) that addresses these challenges, as well as provides DA sample geometries that can be tailored for different analytical methods, including potential on-site analyses. The SUDA samplers, along with a unique holder, are designed for direct attachment to existing taps at uranium processing facilities, allowing gaseous UF6 to come into direct contact with a zeolite film. The SUDA technology features the ability to capture uranium in a more easily shipped and handled form as the solid, more stable, and relatively less hazardous hydrated uranyl fluoride (UO2F2•nH2O), which is formed through the controlled hydrolysis of UF6. We have recently simulated uranium collection under enrichment plant sampling conditions to further improve our understanding of SUDA sampling. Presented here is our recent work on measuring the relationship between sampling conditions and uranium collection, which includes control of the uranium-mass-to-zeolite ratio and assessing variable UF6 gas and sampling parameters that can affect collection using the SUDA sampler.

Pope, Timothy R.↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efficient Subset Simulation using Hamiltonian Neural Network enhanced Markov Chain Monte Carlo Methods

The Monte Carlo method delivers an unbiased estimate of the probability of failure. However, the variance of the estimate depends on the number of evaluated samples. This number must be very large for estimations of a low probability of failure. If the evaluation of each sample is computationally expensive, the crude Monte Carlo simulation strategy is impracticable. Therefore, subset simulations are used to reduce the required number of evaluations. Subset simulations require a Markov Chain Monte Carlo sampler, such as the random walk Metropolis-Hastings algorithm. The algorithm, however, struggles with sampling in low-probability regions, especially if they are narrow. As a consequence, advanced Markov Chain Monte Carlo simulations have been developed. In particular, the Hamiltonian Monte Carlo method explores the target distribution rapidly. Driven by the idea of Hamiltonian dynamics, this sampler provides a non-random walk through the target distribution. The incorporation of subset simulation and Hamiltonian Monte Carlo methods has shown promising results for reliability analysis. One downside of the Hamiltonian Monte Carlo method is that gradient evaluations are computationally expensive, especially when dealing with high-dimensional problems and evaluating long trajectories. We show that integrating Hamiltonian neural networks in Hamiltonian Monte Carlo simulations significantly speeds up the sampling task. Furthermore, the enhancement of adaptive trajectory length within the Hamiltonian Monte Carlo results in the efficient proposal of the following states. Based on this recent enhancement, we provide a fast sampling strategy for subset simulations using Hamiltonian neural networks to replace the evaluation of the gradient and significantly speed up the Hamiltonian Monte Carlo simulation.

97 MATHEMATICS AND COMPUTING↗

Gradient-informed Hamiltonian Monte Carlo for multicomponent CALPHAD model optimization and uncertainty quantification

CALPHAD model parameter optimization is inherently challenging due to non-smooth objective functions, high-dimensional parameter spaces, and the need for uncertainty quantification (UQ). Traditional weighted nonlinear least squares approaches are computationally efficient but local, whereas black-box global optimizers and ensemble Markov Chain Monte Carlo (MCMC) methods provide broader exploration at substantial computational cost. The objective of this work is to combine the global exploration capability of gradient-informed Hamiltonian Monte Carlo – specifically the No-U-Turn Sampler (NUTS) – with local deterministic refinement using BFGS to efficiently optimize multicomponent CALPHAD models with minimal manual intervention. Analytic gradients are computed via the Jansson derivative framework. The methodology is demonstrated on the Cr—Fe binary system and extended to the Cr—Fe—Ni ternary system with 32 degrees of freedom. For Cr—Fe, NUTS achieves comparable or superior optimality relative to ensemble MCMC while requiring over an order-of-magnitude fewer likelihood evaluations. Parameter uncertainties are quantified through NUTS sampling and propagated to thermodynamic observables using local expansion, demonstrating a novel modular approach that combines binary and ternary parameter subsets without requiring global relaxation. These results establish gradient-informed exploration as a scalable strategy for multicomponent CALPHAD optimization and provide a practical route towards efficient higher-order database development with quantified uncertainty.

36 MATERIALS SCIENCE↗

Physics-Informed Machine Learning of Dynamical Systems for Efficient Bayesian Inference

Although the no-u-turn sampler (NUTS) is a widely adopted method for performing Bayesian inference, it requires numerous posterior gradients which can be expensive to compute in practice. Recently, there has been a significant interest in physics-based machine learning of dynamical (or Hamiltonian) systems and Hamiltonian neural networks (HNNs) is a noteworthy architecture. But these types of architectures have not been applied to solve Bayesian inference problems efficiently. We propose the use of HNNs for performing Bayesian inference efficiently without requiring numerous posterior gradients. We introduce latent variable outputs to HNNs (L-HNNs) for improved expressivity and reduced integration errors. We integrate L-HNNs in NUTS and further propose an online error monitoring scheme to prevent sampling degeneracy in regions where L-HNNs may have little training data. We demonstrate L-HNNs in NUTS with online error monitoring consider several complex high-dimensional posterior densities and compare its performance to NUTS.

97 MATHEMATICS AND COMPUTING↗

Reinforcement Learning-Guided Long-Timescale Simulation of Hydrogen Transport in Metals

Diffusion in alloys is an important class of atomic processes. However, atomistic simulations of diffusion in chemically complex solids are confronted with the timescale problem: the accessible simulation time is usually far shorter than that of experimental interest. In this work, long-timescale simulation methods are developed using reinforcement learning (RL) that extends simulation capability to match the duration of experimental interest. Two special limits, RL transition kinetics simulator (TKS) and RL low-energy states sampler (LSS), are implemented and explained in detail, while the meaning of general RL are also discussed. As a testbed, hydrogen diffusivity is computed using RL TKS in pure metals and a medium entropy alloy, CrCoNi, and compared with experiments. The algorithm can produce counter-intuitive hydrogen-vacancy cooperative motion. We also demonstrate that RL LSS can accelerate the sampling of low-energy configurations compared to the Metropolis–Hastings algorithm, using hydrogen migration to copper (111) surface as an example.

36 MATERIALS SCIENCE↗