Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “readout systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Five-second coherence of a single spin with single-shot readout in silicon carbide

An outstanding hurdle for defect spin qubits in silicon carbide (SiC) is single-shot readout, a deterministic measurement of the quantum state. Here, we demonstrate single-shot readout of single defects in SiC via spin-to-charge conversion, whereby the defect’s spin state is mapped onto a long-lived charge state. With this technique, we achieve over 80% readout fidelity without pre- or postselection, resulting in a high signal-to-noise ratio that enables us to measure long spin coherence times. Combined with pulsed dynamical decoupling sequences in an isotopically purified host material, we report single-spin T 2 > 5 seconds, over two orders of magnitude greater than previously reported in this system. The mapping of these coherent spin states onto single charges unlocks both single-shot readout for scalable quantum nodes and opportunities for electrical readout via integration with semiconductor devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Fidelity Ion State Detection Using Trap-Integrated Avalanche Photodiodes

Integrated technologies greatly enhance the prospects for practical quantum information processing and sensing devices based on trapped ions. High-speed and high-fidelity ion state readout is critical for any such application. Integrated detectors offer significant advantages for system portability and can also greatly facilitate parallel operations if a separate detector can be incorporated at each ion-trapping location. Here, we demonstrate ion quantum state detection at room temperature utilizing single-photon avalanche diodes (SPADs) integrated directly into the substrate of silicon ion trapping chips. Furthermore, we detect the state of a trapped Sr + ion via fluorescence collection with the SPAD, achieving 99.92(1)% average fidelity in 450 μs, opening the door to the application of integrated state detection to quantum computing and sensing utilizing arrays of trapped ions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-cell proteomics of Arabidopsis leaf mesophyll reveals dynamic protein responses to water-deficit stress

Background The application of single-cell omics tools to biological systems can provide unique insights into diverse cellular populations and their heterogeneous responses to internal and external perturbations. Thus far, most single-cell studies in plant systems have been limited to RNA-sequencing approaches, which only provide indirect readouts of cellular functions. Results Here, we present a single-cell proteomics workflow for plant cells that integrates tape-sandwich protoplasting, piezoelectric cell sorting, nanoPOTS sample preparation, and ion mobility-based MS data acquisition method for label-free single-cell proteomics analysis of Arabidopsis leaf mesophyll cells. From a single leaf protoplast, over 3,000 proteins were quantified with high precision. The workflow is demonstrated to identify stress associated changes in protein abundance by analyzing 117 protoplasts from well-watered and water-deficit stressed plants. Additionally, we describe a new approach for constructing covarying protein networks at the single-cell level and demonstrate how single-cell protein covariation analysis can reveal previously unrecognized protein functions while also capturing stress-induced changes in protein–protein dynamics. Conclusions The label-free scProteomic approach presented here represents a significant advance through the demonstration of a facile protoplast isolation method combined with deep and precise proteomic coverage of Arabidopsis leaf mesophyll cell types. We believe this study will serve as an informative reference to future plant scProteomic investigations.

Arabidopsis↗

The IDEA detector concept for FCC-ee

A detector concept, named IDEA, optimized for the physics and running conditions at the FCC-ee is presented. After discussing the expected running conditions and the main physics drivers, a detailed description of the individual sub-detectors is given. These include: a very light tracking system with a powerful vertex detector inside a large drift chamber surrounded by a silicon wrapper, a high resolution dual readout crystal electromagnetic calorimeter, an HTS based superconducting solenoid, a dual readout fiber calorimeter and three layers of muon chambers embedded in the magnet flux return yoke. Some examples of the expected detector performance, based on fast and full simulation, are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors

Cluster counting $(dN/dx)$ is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good $π/K$ separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable $dN/dx$ measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/$\sqrt{\textrm{Hz}}$ , surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the $dN/dx$ method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC 4 H 10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.

Drift tube detector↗

Evolution of DUNE’s Production System

The DUNE experiment will start running in 2029 and record 30 PB/year of raw waveforms from Liquid Argon TPCs and photon detectors. The size of individual readouts can range from 100 MB to a typical 8 GB full readout of the detector, and even 100 TB for extended readouts from supernova candidates. These data then need to be cataloged, stored and distributed for processing worldwide. This massive amount of data and a heterogeneous computing environment necessitates a powerful and robust distributed computing infrastructure. In the process of building up that infrastructure, DUNE’s production system has recently undergone an overhaul, in which it has integrated 1) a new workflow management system (justIN) 2) a new data catalog (MetaCat) and 3) a state-of-the-art data management system (Rucio). Simulations of DUNE’s Far Detector and its prototypes ProtoDUNE Horizontal Drift (ProtoDUNE-HD) and ProtoDUNE Vertical Drift (ProtoDUNE-VD), as well as data from ProtoDUNE-HD serve as the first tests of this infrastructure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Probing Excited-State Dynamics of Transmon Ionization

The fidelity and quantum nondemolition character of the dispersive readout in circuit QED are limited by unwanted transitions to highly excited states at specific photon numbers in the readout resonator. This observation can be explained by multiphoton resonances between computational states and highly excited states in strongly driven nonlinear systems, analogous to multiphoton ionization in atoms and molecules. In this work, we utilize the multilevel nature of high-𝐸 𝐽 /𝐸 𝐶 transmons to probe the excited-state dynamics induced by strong drives during readout. With up to ten resolvable states, we quantify the critical photon number of ionization, the resulting state after ionization, and the fraction of the population transferred to highly excited states. Moreover, using pulse shaping to control the photon number in the readout resonator in the high-power regime, we tune the adiabaticity of the transition and verify that transmon ionization is a Landau-Zener-type transition. We further extend these methods to a typical transmon with 𝐸 𝐽 /𝐸 𝐶 ≈ 55 and probe the offset-charge dependence of ionization dynamics in a timed-resolved manner. Our experimental results agree well with the theoretical prediction from a semiclassical driven transmon model and may guide future exploration of strongly driven nonlinear oscillators.

cavity quantum electrodynamics↗

Readout electronics for low occupancy High-Pressure Gas TPCs

High-Pressure Gas Time Projection Chambers (HPgTPCs) have benefits such as low energy thresholds, magnetisability, and 4π acceptance, making them ideal for neutrino experiments such as DUNE. We present the design of an FPGA-based solution optimised for Gaseous Argon Near Detector (ND-GAr), which is part of the Phase-II more capable near detector for DUNE. These electronics reduce the cost significantly compared to using collider readout electronics, which are typically designed for much higher occupancy and therefore, for example, need much larger numbers of FPGAs and power per channel. We demonstrate the performance of our electronics with the Teststand for an Overpressurised Argon Detector (TOAD) at Fermilab in the US at a range of pressures and gas mixtures up to 4.5 barA, reading out ∼10 000 channels from a Multi-Wire Proportional Chamber (MWPC). The operation took place between April and July of 2024. We measure the noise characteristics of the system to be sufficiently low, and we identify sources of noise that can be further mitigated in the next iteration. We also note that the cooling scheme used in the test requires improvement before full-scale deployment. Despite these necessary improvements, we show that the system can fulfil the needs of a HPgTPC for a fraction of the price of collider readout electronics.

Data acquisition concepts↗

Operation of the ATLAS trigger system in Run 2

The ATLAS experiment at the Large Hadron Collider employs a two-level trigger system to record data at an average rate of 1 kHz from physics collisions, starting from an initial bunch crossing rate of 40 MHz. During the LHC Run 2 (2015–2018), the ATLAS trigger system operated successfully with excellent performance and flexibility by adapting to the various run conditions encountered and has been vital for the ATLAS Run-2 physics programme. For proton-proton running, approximately 1500 individual event selections were included in a trigger menu which specified the physics signatures and selection algorithms used for the data-taking, and the allocated event rate and bandwidth. The trigger menu must reflect the physics goals for a given data collection period, taking into account the instantaneous luminosity of the LHC and limitations from the ATLAS detector readout, online processing farm, and offline storage. This document discusses the operation of the ATLAS trigger system during the nominal proton-proton data collection in Run 2 with examples of special data-taking runs. Aspects of software validation, evolution of the trigger selection algorithms during Run 2, monitoring of the trigger system and data quality as well as trigger configuration are presented.

43 PARTICLE ACCELERATORS↗

SQUID Readout of a High-$Q$ Superconducting $LC$ Resonator

We demonstrate the readout of a superconducting $LC$ resonator, with $Q \approx 2 \times 10^{6}$ at approximately 250 kHz, using a dc SQUID followed by a SQUID series-array amplifier readout chain. We find that $Q$ depends on the SQUID flux-bias point, increasing near the shallow-slope point of the SQUID modulation curve and decreasing near the steep-slope point, consistent with the previously observed SQUID damping effects. From this variation, we infer the SQUID effective input impedance. We further infer the effective temperature of the resonator circuit from the resonance peak in the noise spectrum and show that it also depends on the SQUID flux-bias point, suggesting a possible contribution from SQUID back-action noise. This system provides a working prototype for future experiments based on lumped-element resonators with SQUID readout, in particular low-mass axion searches within the DMRadio program.

FOS: Physical sciences↗

Electron shelving of a superconducting artificial atom

Interfacing long-lived qubits with propagating photons is a fundamental challenge in quantum technology. Cavity and circuit quantum electrodynamics (cQED) architectures rely on an off-resonant cavity, which blocks the qubit emission and enables a quantum non-demolition (QND) dispersive readout. However, no such buffer mode is necessary for controlling a large class of three-level systems that combine a metastable qubit transition with a bright cycling transition, using the electron shelving effect. Here we demonstrate shelving of a circuit atom, fluxonium, placed inside a microwave waveguide. With no cavity modes in the setup, the qubit coherence time exceeds 50 μs, and the cycling transition’s radiative lifetime is under 100 ns. By detecting a homodyne fluorescence signal from the cycling transition, we implement a QND readout of the qubit and account for readout errors using a minimal optical pumping model. Our result establishes a resource-efficient (cavityless) alternative to cQED for controlling superconducting qubits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Beam test performance studies of CMS Phase-2 Outer Tracker module prototypes

A new tracking detector will be installed as part of thePhase-2 upgrade of the CMS detector for the high-luminosity LHC era.This tracking detector includes the Inner Tracker, equipped withsilicon pixel sensor modules, and the Outer Tracker, consisting ofmodules with two parallel stacked silicon sensors. The Outer Trackerfront-end ASICs will be able to correlate hits from chargedparticles in these two sensors to perform on-module discriminationof transverse momenta (p$_{T}$). The p$_{T}$information is generated at a frequency of 40 MHz and will be usedin the Level-1 trigger decision of CMS. Prototypes of theso-called 2S modules were tested at the Test Beam Facility at DESYHamburg between 2019 and 2020. These modules use the finalfront-end ASIC, the CMS Binary Chip (CBC), and for the firsttime the Concentrator Integrated Circuit (CIC), optical readoutand on-module power conversion. In total, seven modules were tested,one of which was assembled with sensors irradiated with protons. Animportant aspect was to show that it is possible to read out modulessynchronously. A cluster hit efficiency of about 99.75 % wasachieved for all modules. The CBC p$_{T}$ discriminationmechanism has been verified to work together with the CIC andoptical readout. The measured module performance meets therequirements for operation in the upgraded CMS tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum electronics and optics at the interface of solid neon and superfluid helium

Here, we predict a new quantum electronic structure at the interface between two condensed phases of noble-gas elements: solid neon and superfluid helium. An excess electron injected onto this interface self-confines its wavefunction into a nanometric dome structure. Its size varies with pressure and optical transitions cover a broad mid-infrared spectrum. A collection of such electrons can form a classical Wigner crystal resembling a quantum-dot array on a triangular lattice. Under ultrafast laser illumination, this Wigner crystal can exhibit the quantum optical phenomenon of superradiance in the picosecond time scale. The ultralong spin-coherence time and micron-scale deterministic configurability allow the electrons in this system to serve as quantum information carriers. Their spin states can be controlled and readout by on-chip single-electron devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reporter-Spin-Assisted T 1 Relaxometry

A single-spin quantum sensor can quantitatively detect and image fluctuating electromagnetic fields via their effect on the sensor spin’s relaxation time, thus revealing important information about the target solid-state or molecular structures. However, the sensitivity and spatial resolution of spin relaxometry are often limited by the distance between the sensor and target. Here, we propose an alternative approach that leverages an auxiliary reporter spin in conjunction with a single-spin sensor, a diamond nitrogen-vacancy (N-V) center. We show that this approach can realize a 100-fold measurement sensitivity improvement for realistic working conditions and we experimentally verify the proposed method using a single shallow N-V center. Our work opens up a broad path of inquiry into a range of possible spin systems that can serve as relaxation sensors without the need for optical initialization and readout capabilities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum nanophotonic interface for tin-vacancy centers in thin-film diamond

The negatively charged tin-vacancy center in diamond (SnV − ) is an excellent solid state qubit with optically-addressable transitions and a long electron spin coherence time at elevated (∼1.7 K). However, implementing scalable quantum nodes with high-fidelity optical readout of the electron spin state requires efficient photon emission and collection from the system. Here, in this manuscript, we report a quantum photonic interface for SnV−centers based on one-dimensional photonic crystal cavities fabricated in diamond thin films. Furthermore, we provide a rigorous description of the spontaneous emission dynamics of our system, taking into account individual contributions from both the C and D transitions of the emitter. This allows for determination of Purcell factors per transition and, by extension, the C/D branching ratio SnV− zero phonon line. We observe quality factors up to ~6000 across this sample, and measure up to a 12-fold lifetime reduction, which translates into a Purcell factor of 𝐹 𝐶 =26.2±1.5 for a targeted C transition. By considering the cavity mode polarization alignment with the C and D transition dipole moments, we validate the C/D branching ratio to be 𝜂 BR =0.75±0.01, in line with previous theoretical and experimental findings.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synchronous High-frequency Distributed Readout For Edge Processing At The Fermilab Main Injector And Recycler

The Main Injector (MI) was commissioned using data acquisition systems developed for the Fermilab Main Ring in the 1980s. New VME-based instrumentation was commissioned in 2006 for beam loss monitors (BLM)[2], which provided a more systematic study of the machine and improved displays of routine operation. However, current projects are demanding more data and at a faster rate from this aging hardware. One such project, Real-time Edge AI for Distributed Systems (READS), requires the high-frequency, low-latency collection of synchronized BLM readings from around the approximately two-mile accelerator complex. Significant work has been done to develop new hardware to monitor the VME backplane and broadcast BLM measurements over Ethernet, while not disrupting the existing operations critical functions of the BLM system. This paper will detail the design, implementation, and testing of this parallel data pathway.

43 PARTICLE ACCELERATORS↗

Telecom-Luminescent and Room Temperature Coherent Tetrathiafulvalene-Based Qubits in Spin-Rich Solids

One of the main challenges facing quantum information science (QIS) is the development of robust qubits that can be op-erated under ambient conditions. Current state-of-the-art anionic nitrogen vacancy center (NV–) defect qubits are robust enough to be operated at room temperature but lack scalability and tunability. These are areas where molecular qubits excel, although they typically suffer from poor air stability and fast decoherence at elevated temperatures and in magneti-cally noisy environments. Organic-based systems offer advantages to this end, although examples retaining room tem-perature coherence are still rare. Furthermore, most organic-based systems lack optical transitions similar to NV– centers that could allow for optical initialization and readout. Here we report two new organic-based qubit candidates that demonstrate room temperature coherence in nuclear and electron spin-rich environments. These qubits luminesce far into the near-infrared (NIR, 700-1700 nm) and telecom (~1260-1625 nm) regions, ideal for biological sensing and com-munications applications, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗