Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “readout systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

SAMPA Based Streaming Readout Data Acquisition Prototype

We have assembled a small-scale streaming data acquisition system based on the SAMPA front-end ASIC. The 32-channel SAMPA chip was designed for the high-luminosity upgrade of the ALICE Time Projection Chamber (TPC) detector at the CERN Large Hadron Collider. The goals of the prototype system are to determine if the SAMPA chip is appropriate for use in detector systems at Jefferson Lab, and to gain experience with the hardware and software required to deploy streaming data acquisition systems in nuclear physics experiments. The 800 channel system is composed of components used in the ALICE TPC data acquisition upgrade. Five front-end cards (FEC) support five SAMPA chips each. SAMPA data streams on an FEC are concentrated into two high-speed (4.48 Gb/s) serial data streams by a pair Gigabit Transceiver ASICs (GBTx). These ten streams (44.8 Gb/s) are transmitted from the FECs over fibers to a PCIe based readout unit. The FPGA engine on the readout unit compresses data for transmission to a server via 100 Gb ethernet. Components on the FECs are radiation tolerant. High data rates can be handled. The system is by design scalable and thus provides a functional prototype for high-rate streaming readout at Jefferson Lab and the future Electron Ion Collider. We have made fundamental measurements (noise, linearity, time resolution) on the SAMPA ASIC. We have also coupled the readout system to a small Gas Electron Multiplier (GEM) detector and have studied its response to cosmic rays. A beam test of the system is planned.

ABBOTT, David↗

International Space Station (ISS) Major Constituent Analyzer (MCA) On-Orbit Performance

The Major Constituent Analyzer (MCA) is an essential part of the International Space Station (ISS) environmental control and life support system. The analyzer provides continuous readout of the partial pressures of six gases, nitrogen (N2), oxygen (O2), hydrogen (H2), carbon dioxide (CO2), methane (CH4) and water vapor (H2O) in the various ISS US. on-orbit modules. Continuous readout of the partial pressures of these gases is critical to verifying safe operation of the Atmosphere Revitalization (AR) system, Atmosphere Control System (ACS), and crew safety for Airlock Extravehicular Activities (EVAs). The MCA encountered some operational interruptions since being launched to orbit on Flight 5A in February 2001. Electronic, software, and hardware modifications and on-orbit crew maintenance of the MCA were necessary to restore its capability. This paper describes the modifications and the on-orbit maintenance performed to return the MCA to operational status, including brief explanations of the MCA failures and the associated hardware and electronic modifications. Operational procedures that were required to return the MCA to operational status, and the more recent successes of supporting both Russian and U.S. ISS EVA preparations, are also discussed

Reysa, Richard↗

State-dependent motion of a genetically encoded fluorescent biosensor

Genetically encoded biosensors can measure biochemical properties such as small-molecule concentrations with single-cell resolution, even in vivo. Despite their utility, these sensors are “black boxes”: Very little is known about the structures of their low- and high-fluorescence states or what features are required to transition between them. We used LiLac, a lactate biosensor with a quantitative fluorescence-lifetime readout, as a model system to address these questions. X-ray crystal structures and engineered high-affinity metal bridges demonstrate that LiLac exhibits a large interdomain twist motion that pulls the fluorescent protein away from a “sealed,” high-lifetime state in the absence of lactate to a “cracked,” low-lifetime state in its presence. Understanding the structures and dynamics of LiLac will help to think about and engineer other fluorescent biosensors.

Rosen, Paul C. (ORCID:000000017414454X)↗

ESnet/JLab FPGA Accelerated Transport

To increase the science rate for high data rates/volumes, Thomas Jefferson National Accelerator Facility (JLab) has partnered with Energy Sciences Network (ESnet) to define an edge to data center traffic shaping / steering transport capability featuring data event aware network shaping and forwarding. The keystone of this ESnet+JLab FPGA Accelerated Transport (EJFAT) is the joint development of an AI/ML directed dynamic compute work Load Balancer (LB) of UDP streamed data. The LB is a suite consisting of a Field Programmable Gate Array (FPGA) executing the dynamically configurable, low fixed latency LB data plane featuring real-time packet redirection and high throughput, and a control plane running on the FPGA host computer that monitors network and compute farm telemetry in order to make dynamic AI/ML guided decisions for destination compute host redirection/load balancing and destination resource provisioning. The LB provides for three-tier horizontal scaling across LB suites, core compute hosts, and CPUs within a host. The LB effectively provides seamless integration of edge/core computing to support direct experimental data processing for immediate use by JLab science programs and others such as the EIC as well as data centers of the future requiring high throughput and low latency for both hot and cooled data for both running experiment data acquisition systems and data center use cases.

97 MATHEMATICS AND COMPUTING↗

H3D Data Acquisition Software (H3DDAQ) v1.0

A python library to enable readout of data from commercial H3D gamma-ray detectors. This software perform readout of data and system status, as well as starting and stopping measurements, with either WebREST (HTTP), XML (N42.42), or Binary (FlatBuffers) interfaces.

Joshi, Tenzing↗

Crystal Calorimetry for Charged Lepton Flavor Violation Searches

The Mu2e experiment at Fermilab aims to search for Charged Lepton Flavor Violation (CLFV) through the coherent conversion of a muon into an electron in the field of an aluminum nucleus. This process, highly suppressed in the Standard Model, would clearly indicate new physics if observed. A crucial component of Mu2e is its electromagnetic calorimeter, which enhances the identification and measurement of conversion electrons. The calorimeter consists of two disks of undoped CsI crystals read out by custom-designed SiPMs and fast front-end electronics. This paper presents an overview of the calorimeter’s design, its custom SiPM technology, the readout and data acquisition system, and the results from commissioning tests.Building on the experience from Mu2e, the proposed Mu2e-II upgrade aims to enhance further the experiment’s sensitivity by an order of magnitude. This requires significant advancements in calorimeter technology, particularly in crystal materials and photodetector performance. Studies on BaF$_2$ and LYSO crystals, as well as the development of radiation-hard Silicon Photomultipliers (SiPMs), are currently underway. Test beam results demonstrate promising improvements in energy resolution and timing capabilities, ensuring the feasibility of next-generation calorimetry solutions for Mu2e-II.

Atanov, N. [Dubna, JINR]↗

Developmental solid-state imaging system.

Developmental imaging system for NASA solid state TV camera, describing sensor matrix fabrication and interrogation system mechanization for image readout

Anders, R. A.↗

The Gravity-Probe-B relativity gyroscope experiment - Development of the prototype flight instrument

The Gravity-Probe-B relativity gyroscope experiment (GP-B) will measure the geodetic and frame-dragging precession rates of gyroscopes in a 650 km high polar orbit about the earth. The goal is to measure these two effects, which are predicted by Einstein's General Theory of Relativity, to 0.01 percent (geodetic) and 1 percent (frame-dragging). This paper presents the development progress for full-size prototype flight hardware including the gyroscopes, gyro readout and magnetic shielding system, and an integrated ground test instrument.

Turneaure, J. P.↗

Hydraulic Cylinder With an Integral Position Indicator

Linear variable differential transformer (LVDT) incorporated within cylinder of hydraulic actuator gives precise readout of position of piston relative to cylinder. LVDT contained completely within actuator. System requires precise positioning and position readout for computer control of model motions. Minimal space available for motion cylinders, and precise, continuous position readout (with no steps or pulses) required. Device provides continuous and accurate position indication of a hydraulic cylinder by means of integral, coaxially mounted LVDT.

Goodwin, G. O.↗

A flexible data acquisition system architecture for the Nab experiment

Here, the Nab experiment will measure the electron–neutrino correlation and Fierz interference term in free neutron beta decay to test the Standard Model and probe Beyond the Standard Model physics. Using National Instrument’s PXIe-5171 Reconfigurable Oscilloscope module, we have developed a data acquisition system that is not only capable of meeting Nab’s specifications, but flexible enough to be adapted in situ as the experimental environment dictates. The L1 and L2 trigger logic can be reconfigured to optimize the system for coincidence event detection at runtime through configuration files and LabVIEW controls. This system is capable of identifying L1 triggers at a rate of at least 1 MHz, while reading out a peak signal rate of approximately 2 GB/s. During the commissioning phase of the experiment, the system ran at a sustained readout rate of 400 MB/s of detector signal data originating from roughly 6 kHz L2 triggers, well within the peak performance of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum simulation of boson-related Hamiltonians: techniques, effective Hamiltonian construction, and error analysis

Elementary quantum mechanics proposes that a closed physical system consistently evolves in a reversible manner. However, control and readout necessitate the coupling of the quantum system to the external environment, subjecting it to relaxation and decoherence. Consequently, system-environment interactions are indispensable for simulating physically significant theories. A broad spectrum of physical systems in condensed-matter and high-energy physics, vibrational spectroscopy, and circuit and cavity QED necessitates the incorporation of bosonic degrees of freedom, such as phonons, photons, and gluons, into optimized fermion algorithms for near-future quantum simulations. In particular, when a quantum system is surrounded by an external environment, its basic physics can usually be simplified to a spin or fermionic system interacting with bosonic modes. Nevertheless, troublesome factors such as the magnitude of the bosonic degrees of freedom typically complicate the direct quantum simulation of these interacting models, necessitating the consideration of a comprehensive plan. This strategy should specifically include a suitable fermion/boson-to-qubit mapping scheme to encode sufficiently large yet manageable bosonic modes, and a method for truncating and/or downfolding the Hamiltonian to the defined subspace for performing an approximate but highly accurate simulation, guided by rigorous error analysis. In this pedagogical tutorial review, we aim to provide such an exhaustive strategy, focusing on encoding and simulating certain bosonic-related model Hamiltonians, inclusive of their static properties and time evolutions. Specifically, we emphasize two aspects: (1) the discussion of recently developed quantum algorithms for these interacting models and the construction of effective Hamiltonians, and (2) a detailed analysis regarding a tightened error bound for truncating the bosonic modes for a class of fermion-boson interacting Hamiltonians.

bosonic Hamiltonian↗

Semi-automatic aircraft control system

A flight control type system which provides a tactile readout to the hand of a pilot for directing elevator control during both approach to flare-out and departure maneuvers. For altitudes above flare-out, the system sums the instantaneous coefficient of lift signals of a lift transducer with a generated signal representing ideal coefficient of lift for approach to flare-out, i.e., a value of about 30% below stall. Error signals resulting from the summation are read out by the noted tactile device. Below flare altitude, an altitude responsive variation is summed with the signal representing ideal coefficient of lift to provide error signal readout.

Gilson, Richard D.↗

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of the Mu2e Data AcQuisition System and the Vertical Slice Test of the Straw Tracker

The report discusses the commissioning of the DAQ system of the Mu2e experiment. We studied how the tracker works and especially the tracker readout. We used a generator to send pulses and we tried to understand the output and non-output of the DTC, in order to validate the event and run format and all the failure modes. In section one, we describe Charged Lepton Flavour Violation, the main purpose of Mu2e, in section two we describe Mu2e experiment. Section three presents the tracker description and readout, meanwhile section four the DAQ system and event building. In section five, we start explaining the analysis we have done on events and all the failure modes we discovered. In section six, we have done an analysis of the logger and boardreader rate, we validated the generator frequency in section seven and studied the number of hits in function of the channel number in section eight. To conclude we investigated the channel to channel time differences in section nine and in section ten we explain our Monte Carlo simulation, reproducing ROCs readout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wide field imaging of solar system objects with an 8192 x 8192 CCD mosaic

As part of this program, we successfully completed the construction of the world's largest CCD camera, an 8192 x 8192 CCD mosaic. The system employs 8 2K x 4K 3-edge buttable CCDs arranged in a 2 x 4 chip mosaic. The focal plane has small gaps (less than 1 mm) between mosaic elements and measures over 120 mm x 120 mm. The initial set of frontside illuminated CCDs were developed with Loral-Fairchild in a custom foundry run. The initial lots yielded of order 20 to 25 functional devices, of which we selected the best eight for inclusion for the camera. We have designed a custom 3-edge-buttable package that ensures the CCD dies are mounted flat to plus or minus 10 microns over the entire area of the mosaic. The mosaic camera system consists of eight separate readout signal chains controlled by two independent DSP microcontrollers. These are in turn interfaced to a Sun Sparc-10 workstation through two high speed fiber optic interfaces. The system saw first-light on the Canada-France-Hawaii Telescope on Mauna Kea in March 1995. First-light on the University of Hawaii 2.2-M Telescope on Mauna Kea was in July 1995. Both runs were quite successful. A sample of some of the early science from the first light run is reported in the publication, 'Observations of Weak Lensing in Clusters with an 8192 x 8192 CCD Mosaic Camera'.

Hall, Donald N. B.↗