Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “range measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Performance Demonstration of Self-Powered Neutron Detectors for Steady-State Reactor Operations

The irradiation testing of sensors in reactors is a crucial step towards calibrating and qualifying sensors prior to their deployment in experiments. This report details the process toward qualifying and calibrating custom-designed rhodium-based self-power neutron detectors (Rh-SPNDs) for steady-state reactor irradiations. This process serves to both demonstrate the performance capabilities of Rh-SPNDs as well as to provide experimental data for development of a sensor sensitivity model. Two designs of Rh-SPNDs were tested in various reactors to demonstrate: detection resolution in a low neutron flux environment, a delayed-response compensation technique, output linearity in a large range of neutron flux, and measurement accuracy verified with dosimetry. The detection resolution and compensation technique was demonstrated in the AGN-201m reactor at Idaho State University. The irradiation confirmed the sensors’ capability to perform steady-state operations in a low neutron flux of ~2E8 n/cm 2 -sec. Sensor output linearity coupled with the delayed-response compensation was investigated at the neutron radiography reactor at Idaho National Laboratory. A Rh-SPND was irradiated to neutron fluxes ranging from 2E8 to 2E13 n/cm2-sec range. The measured data demonstrated a wide and linear range of operation with a measured linear sensitivity of 1.0129 ×10 -13 A/W with a correlation-squared value of r 2 =0.9927. The measurement accuracy was investigated at the Advanced Test Reactor Critical reactor. The SPNDs were inserted into a test vehicle with collocated flux wires. Two irradiations with different flux levels were performed, and the SPNDs relative measurement between the two irradiations was calculated to be 1.2613 ± 0.0153 for the small SPND design and 1.1809 ± 0.0108 for the large SPND design. Both SPND measurements fell between the co-axial dosimetry result, which reported 1.218 ± 0.047. Additionally, the preliminary MCNP model for calculating SPND sensitivity was developed in parallel to this work. Modeled neutron spectrum with measured magnitude was used for inputs to determine the simulated SPND output. The results showed an overestimation of signal strength by a factor of 5, which was expected because of model simplification. This leads to future modeling work to account for signal losses from additional physical properties, including high temperature environments for FY-21.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cyclically symmetric radially self-similar phononic pseudocrystal isolator for broadband, ultrasonic vibration bandstop filtering

A 2D phononic pseudocrystal isolator exhibiting cyclic symmetry and radial self-similarity is measured and demonstrated to block a wide range of ultrasonic vibration. Measurements of longitudinal and shear wave blocking effects are made and compared with computational results. The use of the bandgap edge ratio is recommended for quantifying suppression in very-wide-bandgap materials. In conclusion, the upper-to-lower suppression edge frequency ratios of 3–4 are remarkably large for shear waves and even larger for longitudinal waves upper-to-lower suppression ratio (13 at 5 dB), such that 92.5% of frequencies in that range experience ≥ 5 dB of suppression.

Acoustic metamaterial↗

Probing the galaxy–halo connection with total satellite luminosity

ABSTRACT We demonstrate how the total luminosity in satellite galaxies is a powerful probe of dark matter haloes around central galaxies. The method cross-correlates central galaxies in spectroscopic galaxy samples with fainter galaxies detected in photometric surveys. Using models, we show that the total galaxy luminosity, Lsat, scales linearly with host halo mass, making Lsat an excellent proxy for Mh. Lsat is also sensitive to the formation time of the halo. We demonstrate that probes of galaxy large-scale environment can break this degeneracy. Although this is an indirect probe of the halo, it yields a high signal-to-noise ratio measurement for galaxies expected to occupy haloes at <1012 M⊙, where other methods suffer from larger errors. In this paper, we focus on observational and theoretical systematics in the Lsat method. We test the robustness of our method of finding central galaxies and our methods of estimating the number of background galaxies. We implement this method on galaxies in the Sloan Digital Sky Survey (SDSS) data, with satellites identified in fainter imaging data. We find excellent agreement between our theoretical predictions and the observational measurements. Finally, we compare our Lsat measurements to weak lensing estimates of Mh for red and blue subsamples. In the stellar mass range where the measurements overlap, we find consistent results, where red galaxies live in larger haloes. However, the Lsat approach allows us to probe significantly lower mass galaxies. At these masses, the Lsat values are equivalent. This example shows the potential of Lsat as a probe of dark haloes.

79 ASTRONOMY AND ASTROPHYSICS↗

Phosphorus sorption and its environmental predictors across pantropical forest soils sampled over the past decade

Tropical forest productivity is frequently constrained by soil phosphorus (P) availability, yet global Land Surface Model (LSM), which are used to simulate ecosystem processes, still represent P cycling in tropical regions only in a limited way, largely because of scarce observational data. Phosphorus adsorption and desorption of dissolved inorganic P to and from soil minerals (hereafter termed sorption), is an important process for predicting how much P is available to plants. This dataset was created to improve predictions of soil P sorption in tropical soils by identifying the isotherm equation that best describes pantropical soils. It includes raw measurements of environmental variables, such as soil properties and climate, together with P sorption data collected from 40 forest soil pits from 9 Forest Global Earth Observatory (ForestGEO) sites across 7 tropical countries during 2018-2022. The data are organized by site, country, and continent. Each site may include several soil pits. For each pit, P sorption was measured across a range of soil P concentrations to build sorption isotherm curves, typically with about 6 to 8 measurements per curve. While sorbed P varies across these concentration levels, the other environmental variables remain constant at the plot level.

Aluminum oxide↗

Interlaboratory Reproducibility of Contour Method Data in a High Strength Aluminum Alloy

The contour method for residual stress measurement has seen significant development, but an experimental reproducibility study utilizing physical samples has not been published. A double-blind reproducibly study is reported, having scope beginning with EDM cutting and ending with residual stress calculation. A reinforced I-beam sample geometry is identified for its unique residual stress profile when extracted from residual stress bearing quenched aluminum bar (7050-T74). Contour measurements are prescribed on a midplane of symmetry with dimensions 24.0 mm by 50.0 mm. Fourteen identically prepared samples are fabricated from a single long bar with well characterized and uniform residual stress. Five samples throughout the bar are identified for planning measurements to validate sample uniformity and overall suitability of the residual stress field. The planning measurements employ a range of techniques: contour method, neutron diffraction, and hole-drilling. Eight samples are distributed to an international group of participants to execute their standard measurement practice. A double-blind process is followed to provide anonymity. Results are provided by eight participants: six being self-similar and two being quite different, the latter set aside as outliers. An average residual stress field is established from non-outlying results and the spatial distribution of reproducibility standard deviation is determined. The average stress field ranges from -60 to 70 MPa and the reproducibility standard deviation averages 8.1 MPa on the measurement plane. The average reproducibility standard deviation is about 3 × larger for points within 1.0 mm of plane boundaries (17.6 MPa) than for the remaining points (6.1 MPa). Reproducibility standard deviation (among different labs) for contour method residual stress measurement is found to be very similar to repeatability standard deviation (in a single lab) reported in prior work. The reproducibility observed here, for the entire measurement process, is also similar to that found in a prior reproducibility study limited to contour method data analysis.

36 MATERIALS SCIENCE↗

CENTAUR - The small- and wide-angle neutron scattering diffractometer/spectrometer for the Second Target Station of the Spallation Neutron Source

CENTAUR has been selected as one of the eight initial instruments to be built at the Second Target Station (STS) of the Spallation Neutron Source at Oak Ridge National Laboratory. It is a small-angle neutron scattering (SANS) and wide-angle neutron scattering (WANS) instrument with diffraction and spectroscopic capabilities. This instrument will maximally leverage the high brightness of the STS source, the state-of-the-art neutron optics, and a suite of detectors to deliver unprecedented capabilities that enable measurements over a wide range of length scales with excellent resolution, measurements on smaller samples, and time-resolved investigations of evolving structures. Notably, the simultaneous WANS and diffraction capability will be unique among neutron scattering instruments in the United States. This instrument will provide much needed capabilities for soft matter and polymer sciences, geology, biology, quantum condensed matter, and other materials sciences that need in situ and operando experiments for kinetic and/or out-of-equilibrium studies. Beam polarization and a high-resolution chopper will enable detailed structural and dynamical investigations of magnetic and quantum materials. CENTAUR’s excellent resolution makes it ideal for low-angle diffraction studies of highly ordered large-scale structures, such as skyrmions, shear-induced ordering in colloids, and biomembranes. Additionally, the spectroscopic mode of this instrument extends to lower momentum transfers than are currently possible with existing spectrometers, thereby providing a unique capability for inelastic SANS studies.

47 OTHER INSTRUMENTATION↗

Thermal Neutron Scattering Evaluation of Yttrium Hydride (FY2020 Progress)

This paper details the thermal neutron scattering measurements of yttrium hydride for various hydrogen concentrations and temperatures that were conducted at the Spallation Neutron Source at Oak Ridge National Laboratory. Measurements at a temperature range of 5 to 1,200 K were conducted to determine the change in inelastic scattering as a function of temperature and to probe for any anharmonic effects known to exist in other metallic hydrides. Additionally, hydrogen concentrations of YH x that range from x = 1.62 to 1.90 were measured to determine the effects of varying hydrogen concentration on the inelastic neutron spectra. Changes in temperature affected the inelastic spectra in unanticipated ways, indicating that there are anharmonic effects, whereas hydrogen concentration does not significantly affect the inelastic spectra. These measurements were compared against the ENDF/B-VIII.0 thermal scattering files of hydrogen in YH 2 and yttrium in YH 2 , as well as a new thermal scattering file created by using the stochastic temperature-dependent effective potential (s-TDEP). Both libraries were found to be in good agreement with the experimental data at lower temperatures. At higher temperatures, the s-TDEP method is better at predicting the experimentally observed softening of phonon modes in acoustic and optical regions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SAIL-Isotopologue (SAIL-iso) Field Campaign Report

The SAIL-iso project took place from November 19, 2022 to June 3, 2023 as part of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) project at the main project site in Gothic, Colorado. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in a remote mountainous watershed. Water vapor isotopologue and humidity measurements were determined using a Los Gatos Research Triple Water Vapor Isotope Analyzer (TWVIA). The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through Teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. Multiple sources of uncertainty are introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) Vienna Standard Mean Ocean Water – Standard Light Antarctic Precipitation (VSMOW-SLAP) calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ 18 O.

54 ENVIRONMENTAL SCIENCES↗

Water vapor isotopic composition during TRACER IOP

The TRACER-Iso project took place from June 1 to September 30, 2022 as part of the intensive observation period (IOP) of the Tracking Aerosol Convection Interactions (TRACER) project at the main project site at the La Porte, Texas, municipal airport. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in deep convection in a polluted urban setting. Water vapor isotopologue and humidity measurements were determined using a Picarro L2130 Water Vapor Isotope Analyzer. The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, and a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. There are multiple sources of uncertainty introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) VSMOW-SLAP calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ18O.

54 ENVIRONMENTAL SCIENCES↗

Identifying DQ-Domain Admittance Models of a 2.3-MVA Commercial Grid-Following Inverter Via Frequency-Domain and Time-Domain Data

Here, we present two methods to identify the admittance of a 2.3-MVA commercial grid-following inverter through frequency-domain data and time-domain data. In addition to the well-known harmonic injection method to obtain the admittance at frequency points followed by vector fitting, we adopt a step response-based method where the step response data of the converter are collected and their s-domain expressions are obtained. In turn, the s-domain admittance model of the converter is found. The two methods can be used for cross validation. Step responses and frequency-domain responses obtained from the two methods are compared. Results show that the time- domain data-based method leads to an admittance comparable with that from the frequency-domain measurement in the range less than 60 Hz. In addition, two insights are obtained from the frequency-domain admittance measurements. First, when the dq- frame is aligned to the point of common coupling (PCC) voltage, the per unit DQ-domain admittance directly reflects operating conditions. Second, existence of negative-sequence control can be detected via sequence-domain admittances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The two-photon exchange experiment at DESY

We propose a new measurement of the ratio of positron-proton to electron-proton elastic scattering at DESY. The purpose is to determine the contributions beyond single-photon exchange, which are essential for the Quantum Electrodynamic (QED) description of the most fundamental process in hadronic physics. By utilizing a 20 cm long liquid hydrogen target in conjunction with the extracted beam from the DESY synchrotron, we can achieve an average luminosity of 2.12 x 10 35 cm –2 •s –1 (≈ 200 times the luminosity achieved by OLYMPUS). The proposed two-photon exchange experiment (TPEX) entails a commissioning run at a beam energy of 2 GeV, followed by measurements at 3 GeV, thereby providing new data up to Q 2 = 4.6 (GeV/c) 2 (twice the range of current measurements). We present and discuss the proposed experimental setup, run plan, and expectations.

Physics↗

Effects of Co substitution on the structural and magnetic properties of Sr ( Ni 1 - x Co x ) 2 P 2

Although SrNi 2 P 2 adopts the common ThCr 2 Si 2 structure for T ≥ 325 K, being in an uncollapsed tetragonal state rather than a collapsed tetragonal version, it is a special case for the ThCr 2 Si 2 class: on cooling below 325 K it adopts a one-third collapsed orthorhombic phase where one out of every three P rows bonds across the Sr layers. On the other hand, SrCo 2 P 2 only exhibits the uncollapsed ThCr 2 Si 2 structure from room temperature down to 1.8 K. Regardless of their low-temperature structures, neither SrNi 2 P 2 nor SrCo 2 P 2 manifests magnetic transitions down to 50 mK and 2 K, respectively. In this work we report the effects of Co substitution in Sr(Ni 1 - x Co x ) 2 P 2 , which allows for tuning the transition between the one-third collapsed and the uncollapsed structure. We find a rapid decrease of the one-third collapsed structural transition temperature with increasing Co fraction, until reaching full suppression for x ≥ 0.1. Substitution levels in the range 0.11 ≤ x ≤ 0.58 show no signs of any transition down to 1.8 K in the magnetization or resistance measurements in the range 1.8 ≤ T ≤ 300 K. However, different magnetically ordered states emerge for x ≥ 0.65, and disappear for x ≥ 0.99, recovering the known paramagnetic properties of the parent compound SrCo 2 P 2 . Further, these results are summarized in a phase diagram, built upon the characterization by energy dispersive x-ray spectroscopy, x-ray diffraction, temperature-dependent resistance, and field- and temperature-dependent magnetization measurements done on single crystals with different Co fraction. Both the magnetic and structural properties are compared to other systems with ThCr 2 Si 2 structure that exhibit magnetic ordering and collapsed tetragonal transitions. The magnetic ordering and moment formation are well described by Takahashi's spin fluctuation theory of itinerant electron magnetism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Entanglement properties of disordered quantum spin chains with long-range antiferromagnetic interactions

Entanglement measures are useful tools in characterizing otherwise unknown quantum phases and indicating transitions between them. Here we examine the concurrence and entanglement entropy in quantum spin chains with random long-range couplings, spatially decaying with a power-law exponent $\textit{α}$. Using the strong disorder renormalization group (SDRG) technique, we find by analytical solution of the master equation a strong disorder fixed point, characterized by a fixed point distribution of the couplings with a finite dynamical exponent, which describes the system consistently in the regime $α > \frac{1}{2}$ . A numerical implementation of the SDRG method yields a power-law spatial decay of the average concurrence, which is also confirmed by exact numerical diagonalization. However, we find that the lowest-order SDRG approach is not sufficient to obtain the typical value of the concurrence. We therefore implement a correction scheme which allows us to obtain the leading-order corrections to the random singlet state. This approach yields a power-law spatial decay of the typical value of the concurrence, which we derive both by a numerical implementation of the corrections and by analytics. Next, using numerical SDRG, the entanglement entropy (EE) is found to be logarithmically enhanced for all $\textit{α}$, corresponding to a critical behavior with an effective central charge $\textit{c}$ = ln(2), independent of $\textit{α}$. This is confirmed by an analytical derivation. Using numerical exact diagonalization (ED), we confirm the logarithmic enhancement of the EE and a weak dependence on $\textit{α}$. For a wide range of partition size $\textit{l}$, the EE fits a critical behavior with a central charge close to $\textit{c}$ = 1, which is the same as for the clean Haldane-Shastry model with a power-law-decaying interaction with $\textit{α}$ = 2. Only for small $l \ll L$, in a range which increases with the number of spins N, we find deviations which are rather consistent with the strong disorder fixed point central charge $\textit{c}$ = ln(2). Furthermore, we find using ED that the concurrence shows power-law decay, albeit with smaller power exponents than obtained by SDRG. Finally, we also present results obtained with DMRG and find agreement with ED for sufficiently small $\textit{α}$ < 2, whereas for larger $\textit{α}$ DMRG tends to underestimate the entanglement entropy and finds a faster decaying concurrence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Strain dependence of Auger recombination in 3 μm GaInAsSb/GaSb type-I active regions

We differentiate the effect of strain induced by lattice-mismatched growth from strain induced by mechanical deformation on cubic nonradiative Auger recombination in narrow-gap GaInAsSb/GaSb quantum well (QW) heterostructures. The typical reduction in the Auger coefficient observed with lattice-mismatched growth appears to be due to the concomitant compositional change rather than the addition of strain, with implications for mid-IR semiconductor laser design. We induced a range of internal compressive strain in five samples from -0.90% to -2.07% by varying the composition during the growth and mechanically induced a similar range of internal strain in analogous quantum well membrane samples. We performed time-resolved photoluminescence and differential reflectivity measurements to extract the carrier recombination dynamics, taken at 300 K with carrier densities from 2.7 × 10 18 cm -3 to 1.4 × 10 19 cm -3 . We observed no change with strain in the cubic Auger coefficient of samples that were strained mechanically, but we did observe a trend with strain in samples that were strained by the QW alloy composition. Measured Auger coefficients ranged from 3.0 × 1 0 - 29 cm 6 s -1 to 3.0 × 1 0 - 28 cm 6 s -1 .

36 MATERIALS SCIENCE↗

Characterization Results for the August 2025 Tank Farm 2H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents the average characterization results for the August 2025 2H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 ( 137 Cs), strontium-90 ( 90 Sr), and iodine-129 ( 129 I) with the radionuclide concentration limits specified by the WAC. These analyses were performed in duplicate, and all three measured radionuclide concentrations were within ETP WAC limits. A summary of the analytical results for this 2H evaporator overhead sample includes the following: The measured cesium-137 activity in the 2H evaporator overhead sample averaged 3.02E+02 dpm/mL, which is below the ETP WAC limit of 1.30E+03 dpm/mL. The strontium-90 activity in the 2H evaporator overhead sample averaged 3.33E+00 dpm/mL, which is below the ETP WAC limit of 1.76E+02 dpm/mL. The iodine-129 activity in the 2H evaporator overhead sample averaged 1.20E-01 dpm/mL, which is below the ETP WAC limit of 1.00E+00 dpm/mL. Although the measurements for Cs-137 and Sr-90 are lower compared to previous years, the results remain within a similar range to past measurements and are well below the WAC limits. Iodine-129 indicates detectable results compared to previous years, which can be attributed to recent salt batch processing trending close to the WAC limit for saltstone production. However, these results are still below the ETP WAC limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Standoff inspection using geometry-informed full-wavefield response measurements

A vibrometer may measure acoustic responses in portions of a structure along a scan path to acoustic excitation of the structure. A ranging device may measure distances to the portions of the structure along the scan path. A three-dimensional point cloud may be generated based on the acoustic responses in the portions of the structure and the distances to the portions of the structure. The three-dimensional point cloud may include points representing geometry of the portions of the structure. The points may be associated with the acoustic responses in corresponding portions of the structure. One or more properties of the structure may be determined based on an analysis of the three-dimensional point cloud.

Flynn, Eric Brian↗

Measurement of Stability Diagram at IOTA at Fermilab

Nonlinear focusing elements can enhance the stability of particle beams in high-energy colliders by means of Landau Damping, through the tune spread which is introduced. We propose an experiment at Fermilab’s Integrable Optics Test Accelerator (IOTA) to investigate the influence of nonlinear focusing elements on the transverse stability of the beam. In this experiment, we employ an anti-damper, an active transverse feedback system, as a controlled mechanism to induce coherent beam instability. By utilizing the anti-damper, we can examine the impact of the nonlinear focusing element on the beam’s transverse stability. The stability diagram, a tool used to determine the system’s stability, will be measured using a recently demonstrated method at the LHC. This measurement is carried out experimentally by selecting specific threshold gains and measuring them for a range of phases. The stability diagram is represented by gei¿ on the complex plane. The experiment at IOTA adds insight towards the stability diagram measurement method by supplying a reduced machine impedance, to investigate the impedance’s effect on the stability diagram, as well as a larger range of phase measurements.

43 PARTICLE ACCELERATORS↗

The Critical Need for Innovations in Instruments and Techniques to Enable In-Situ Cold Ion and Cold Electron Measurements within the Magnetosphere

Relatively few studies have focused on the cold plasma populations of the magnetosphere due to difficulties associated with obtaining measurements. The cold particle populations are defined here as those with total energy approximately <100 eV which is an energy range for which measurements are difficult (regardless of species), but which often make up the bulk of the plasma density. These populations have known and suspected impacts on the structure and dynamics of the magnetosphere. Unfortunately, the lack of accurate measurements of the cold ion and cold electron populations through the magnetosphere makes closure of these science questions extremely difficult if not impossible. In a complex system of interconnected parts like the Earth’s magnetosphere, a lack of understanding of one part of the system (the cold electron and ion populations) is disabling. Hence, until cold electron and cold ion measurements are obtained robustly with every mission, the magnetospheric plasma environment cannot be completely understood. This will require innovations in plasma spectrometers and associated techniques required to obtain high-fidelity in-situ measurements of the cold ion and cold electron populations in the magnetosphere. This paper seeks to review the instruments and techniques that have been used to date and present possible options for future missions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗