Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantitative phase imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Characterizing the microstructures of mammalian enamel by synchrotron phase contrast microCT

The enamel of mammalian teeth is a highly mineralized tissue that must endure a lifetime of cyclic contact and is inspiring the development of next-generation engineering materials. Attempts to implement enamel-inspired structures in synthetic materials have had limited success, largely due to the absence of a detailed understanding of its microstructure. Here, the present work used synchrotron phase-contrast microCT imaging to evaluate the three-dimensional microstructure of enamel from four mammals including Lion, Gray Wolf, Snow Leopard, and Black Bear. Quantitative results of image analysis revealed that the decussation pattern of enamel consists of discrete diazone (D) and parazone (P) bands of rods organized with stacking arrangement of D+/P/D-/P in all mammals evaluated; the D+ and D- refer to distinct diazone bands with juxtaposed rod orientations from the reference plane. Furthermore, the rod orientations in the bands can be described in terms of two principal angles, defined here as the pitch and yaw. While the pitch angle increases from the outer enamel to a maximum (up to ≈ 40°) near the dentin enamel junction, minimal spatial variations are observed in yaw across the enamel thickness. There are clear differences in the decussation parameters of enamel across species that are interpreted here with respect to the structural demands placed on their teeth. The rod pitch and band width of enamel are identified as important design parameters and appear to be correlated with the bite force quotient of the four mammals evaluated.

36 MATERIALS SCIENCE↗

SU-F-BRE-16: VMAT Commissioning and Quality Assurance (QA) of An Elekta Synergy-STM Linac Using ICOM Test HarnessTM

Purpose: To establish a set of tests based on the iCOM software that can be used to commission and perform periodic QA of VMAT delivery on the Elekta Synergy-S, commonly known as the Beam Modulator (BM). Methods: iCOM is used to create and deliver customized treatment fields to characterize the system in terms of 1) MLC positioning accuracy under static and dynamic delivery with full gantry rotation, 2) MLC positioning with known errors, 3) Maximum dose rate, 4) Maximum MLC speed, 5) Maximum gantry speed, 6) Synchronization: gantry speed versus dose rate, and 7) Synchronization: MLC speed versus dose rate. The resulting images were captured on the iView GT and exported in DICOM format to Dosimetry Check™ system for visual and quantitative analysis. For the initial commissioning phase, the system tests described should be supplemented with extensive patient QAs covering all clinically relevant treatment sites. Results: The system performance test suite showed that on our Synergy-S, MLC positioning was accurate under both static and dynamic deliveries. Intentional errors of 1 mm were also easily identified on both static and dynamic picket fence tests. Maximum dose rate was verified with stop watch to be consistently between 475-480 MU/min. Maximum gantry speed and MLC speed were 5.5 degree/s and 2.5 cm/s respectively. After accounting for beam flatness, both synchronization tests, gantry versus dose rate and MLC speed versus dose rate, were successful as the fields were uniform across the strips and there were no obvious cold/hot spots. Conclusion: VMAT commissioning and quality assurance should include machine characterization tests in addition to patient QAs. Elekta iCOM is a valuable tool for the design of customized VMAT field with specific MU, MLC leaf positions, dose rate, and indirect control of MLC and gantry speed at each of its control points.

07 ISOTOPE AND RADIATION SOURCES↗

The phase function of Venus cloud particles from Mariner 10 data

Mariner 10 images of Venus taken at several phase angles were photometrically reduced. The analysis shows that the phase function of the cloud particles is not isotropic, as had been deduced earlier from the brightness distribution on spacecraft images taken at a single phase angle, but has a broad minimum near 60 deg and is forward-scattering. The scattering properties are in quantitative agreement with previous deductions from earth-based polarization measurements by Hansen and his associates.

Hapke, B.↗

High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.

60 APPLIED LIFE SCIENCES↗

Reconstructing porous media using generative flow networks

One area of intense scientific interest for the study of sandstones, carbonates, and shale at the pore scale is the use of limited image and petrophysical data to generate multiple realizations of a rock’s pore structure. Such images aid efforts to quantify uncertainty in petrophysical properties, including porosity–permeability transforms. We develop and evaluate a deep learning-based method to synthesize porous media volumes using a so-called generative flow model trained on x-ray microscope images of rock texture and pore structure. These models are optimized on a log-likelihood objective and they synthesize large and realistic three-dimensional images. Further, we demonstrate the rapid generation of sandstone image volumes that display realism as gauged by quantitative comparison of topological features using Minkowski functionals of porosity, specific surface area, and the Euler–Poincaré characteristic (i.e., pore connectivity). We also evaluate the single-phase permeability using Navier–Stokes and lattice Boltzmann methods and show that transport properties of the generated samples match measured trends.

58 GEOSCIENCES↗

edxia: Microstructure characterisation from quantified SEM-EDS hypermaps

The characterisation of cement paste microstructure is an important step towards understanding durability mechanisms in cementitious materials. Scanning electron microscopy (SEM) coupled with energy dispersive spectroscopy (EDS) is a widely used technique to analyse the microstructure at the micron-scale. However, it is challenging, notably because the characteristic size of many phases is found on a scale smaller than the EDS interaction volume. This work presents a new image analysis framework to identify phases and quantify the microstructure of cementitious materials from SEM-EDS hypermaps. By leveraging domain knowledge, representative points are attributed to phases and mixtures of phases based on ratio plots. Then, quantitative analysis of the microstructure can be carried out (chemical composition, particle size distributions, volume fractions, …). We demonstrate the abilities of the framework, and we present possible applications and extensions of the method. The framework is available as both a graphical interface and a Python code.

36 MATERIALS SCIENCE↗

Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney

Purpose: The radioligand {sup 11}C-KR31173 has been introduced for positron emission tomography (PET) imaging of the angiotensin II subtype 1 receptor in the kidney in vivo. To study the biokinetics of {sup 11}C-KR31173 with a compartmental model, the input function is needed. Collection and analysis of arterial blood samples are the established approach to obtain the input function but they are not feasible in patients with renal diseases. The goal of this study was to develop a quantitative technique that can provide an accurate image-derived input function (ID-IF) to replace the conventional invasive arterial sampling and test the method in pigs with the goal of translation into human studies. Methods: The experimental animals were injected with [{sup 11}C]KR31173 and scanned up to 90 min with dynamic PET. Arterial blood samples were collected for the artery derived input function (AD-IF) and used as a gold standard for ID-IF. Before PET, magnetic resonance angiography of the kidneys was obtained to provide the anatomical information required for derivation of the recovery coefficients in the abdominal aorta, a requirement for partial volume correction of the ID-IF. Different image reconstruction methods, filtered back projection (FBP) and ordered subset expectation maximization (OS-EM), were investigated for the best trade-off between bias and variance of the ID-IF. The effects of kidney uptakes on the quantitative accuracy of ID-IF were also studied. Biological variables such as red blood cell binding and radioligand metabolism were also taken into consideration. A single blood sample was used for calibration in the later phase of the input function. Results: In the first 2 min after injection, the OS-EM based ID-IF was found to be biased, and the bias was found to be induced by the kidney uptake. No such bias was found with the FBP based image reconstruction method. However, the OS-EM based image reconstruction was found to reduce variance in the subsequent phase of the ID-IF. The combined use of FBP and OS-EM resulted in reduced bias and noise. After performing all the necessary corrections, the areas under the curves (AUCs) of the AD-IF were close to that of the AD-IF (average AUC ratio =1 ± 0.08) during the early phase. When applied in a two-tissue-compartmental kinetic model, the average difference between the estimated model parameters from ID-IF and AD-IF was 10% which was within the error of the estimation method. Conclusions: The bias of radioligand concentration in the aorta from the OS-EM image reconstruction is significantly affected by radioligand uptake in the adjacent kidney and cannot be neglected for quantitative evaluation. With careful calibrations and corrections, the ID-IF derived from quantitative dynamic PET images can be used as the input function of the compartmental model to quantify the renal kinetics of {sup 11}C-KR31173 in experimental animals and the authors intend to evaluate this method in future human studies.

60 APPLIED LIFE SCIENCES↗

Quantification of organ motion based on an adaptive image-based scale invariant feature method

Purpose: The availability of corresponding landmarks in IGRT image series allows quantifying the inter and intrafractional motion of internal organs. In this study, an approach for the automatic localization of anatomical landmarks is presented, with the aim of describing the nonrigid motion of anatomo-pathological structures in radiotherapy treatments according to local image contrast.Methods: An adaptive scale invariant feature transform (SIFT) was developed from the integration of a standard 3D SIFT approach with a local image-based contrast definition. The robustness and invariance of the proposed method to shape-preserving and deformable transforms were analyzed in a CT phantom study. The application of contrast transforms to the phantom images was also tested, in order to verify the variation of the local adaptive measure in relation to the modification of image contrast. The method was also applied to a lung 4D CT dataset, relying on manual feature identification by an expert user as ground truth. The 3D residual distance between matches obtained in adaptive-SIFT was then computed to verify the internal motion quantification with respect to the expert user. Extracted corresponding features in the lungs were used as regularization landmarks in a multistage deformable image registration (DIR) mapping the inhale vs exhale phase. The residual distances between the warped manual landmarks and their reference position in the inhale phase were evaluated, in order to provide a quantitative indication of the registration performed with the three different point sets.Results: The phantom study confirmed the method invariance and robustness properties to shape-preserving and deformable transforms, showing residual matching errors below the voxel dimension. The adapted SIFT algorithm on the 4D CT dataset provided automated and accurate motion detection of peak to peak breathing motion. The proposed method resulted in reduced residual errors with respect to standard SIFT, providing a motion description comparable to expert manual identification, as confirmed by DIR.Conclusions: The application of the method to a 4D lung CT patient dataset demonstrated adaptive-SIFT potential as an automatic tool to detect landmarks for DIR regularization and internal motion quantification. Future works should include the optimization of the computational cost and the application of the method to other anatomical sites and image modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pore-Scale Analysis of Calcium Carbonate Precipitation and Dissolution Kinetics in a Microfluidic Device

In this work, we have characterized the calcium carbonate (CaCO 3 ) precipitates over time caused by reaction-driven precipitation and dissolution in a micromodel. Reactive solutions were continuously injected through two separate inlets, resulting in transverse-mixing induced precipitation during the precipitation phase. Subsequently, a dissolution phase was conducted by injecting clean water (pH = 4). The evolution of precipitates was imaged in two and three dimensions (2-, 3-D) at selected times using optical and confocal microscopy. With estimated reactive surface area, effective precipitation and dissolution rates can be quantitatively compared to results in the previous works. Our comparison indicates that we can evaluate the spatial and temporal variations of effective reactive areas more mechanistically in the microfluidic system only with the knowledge of local hydrodynamics, polymorphs, and comprehensive image analysis. Here, our analysis clearly highlights the feedback mechanisms between reactions and hydrodynamics. Pore-scale modeling results during the dissolution phase were used to account for experimental observations of dissolved CaCO 3 plumes with dissolution of the unstable phase of CaCO 3 . Mineral precipitation and dissolution induce complex dynamic pore structures, thereby impacting pore-scale fluid dynamics. Pore-scale analysis of the evolution of precipitates can reveal the significance of chemical and pore structural controls on reaction and fluid migration.

58 GEOSCIENCES↗

A consistent path for phase determination based on transmission electron microscopy techniques and supporting simulations

Here this work addresses aspects for the analysis of industrial relevant materials via transmission electron microscopy (TEM). The complex phase chemistry and structural diversity of these materials require several characterization techniques to be employed simultaneously; unfortunately, different characterization techniques often lack connection to yield a complete and consistent picture. This paper describes a continuous path, starting with the acquisition of 3D diffraction data – alongside classical high-resolution imaging techniques – and linking the structural characterization of hard metal industrial samples with energy-loss fine-structure simulations, quantitative electron energy-loss (EEL) and energy-dispersive X-ray (EDX) spectroscopy. Thereby, the compositional analysis of a MAX phase indicated an offset of the hydrogenic, theoretical sensitivity factors, originating from poorly-adjusted screening factors. In a next step, these results were matched against quantitative compositions and parameters obtained from X-ray spectroscopy data, carried out synchronously with EELS.

36 MATERIALS SCIENCE↗

Comparison of Image Restoration Methods for Lunar Epithermal Neutron Emission Mapping

Orbital measurements of neutrons by the Lunar Exploring Neutron Detector (LEND) onboard the Lunar Reconnaissance Orbiter are being used to quantify the spatial distribution of near surface hydrogen (H). Inferred H concentration maps have low signal-to-noise (SN) and image restoration (IR) techniques are being studied to enhance results. A single-blind. two-phase study is described in which four teams of researchers independently developed image restoration techniques optimized for LEND data. Synthetic lunar epithermal neutron emission maps were derived from LEND simulations. These data were used as ground truth to determine the relative quantitative performance of the IR methods vs. a default denoising (smoothing) technique. We review and used factors influencing orbital remote sensing of neutrons emitted from the lunar surface to develop a database of synthetic "true" maps for performance evaluation. A prior independent training phase was implemented for each technique to assure methods were optimized before the blind trial. Method performance was determined using several regional root-mean-square error metrics specific to epithermal signals of interest. Results indicate unbiased IR methods realize only small signal gains in most of the tested metrics. This suggests other physically based modeling assumptions are required to produce appreciable signal gains in similar low SN IR applications.

McClanahan, T. P.↗

Polarization Control via Artificial Optical Nonlinearity in Dielectric Metasurfaces

Nonlinear optical phenomena are generally governed by geometry in matter systems, as they depend on the spatial arrangement of atoms within materials or molecules. Metasurfaces, through precisely designed geometries on a subwavelength scale, allow the optical response of a material to be tailored far beyond its natural properties. Therefore, metasurfaces are highly appealing for enabling the engineering of nonlinear optical interactions. Current studies of nonlinear metasurfaces predominantly focus on the phase control of the generated light. Nonetheless, investigating the tensorial nature of the nonlinearity of metasurfaces and its effect on the polarization of the generated light is critical to fully unlocking a range of applications, such as nonlinear vector beam generation and nonlinear polarization imaging. Here, we study the artificial optical nonlinearity of a dielectric metasurface originating from its meta-atom symmetry and describe the third-order nonlinear behavior by considering the polarization degree of freedom. We establish an effective nonlinear medium model that serves as a design toolbox for developing amorphous silicon-based geometric metasurfaces with customizable features for third-harmonic generation. We further extract quantitative values of the artificial nonlinear susceptibility tensor elements related to the investigated nonlinear process and geometry. The implemented functional devices demonstrate the versatility of dielectric metasurfaces in shaping the emitted light in terms of amplitude, phase, and polarization for the precise engineering of advanced nonlinear architectures targeting applications in nonlinear imaging and complex light generation.

Diffraction↗

Advanced ballistic range technology

Experimental interferograms, schlieren, and shadowgraphs are used for quantitative and qualitative flow-field studies. These images are created by passing light through a flow field, and the recorded intensity patterns are functions of the phase shift and angular deflection of the light. As part of the grant NCC2-583, techniques and software have been developed for obtaining phase shifts from finite-fringe interferograms and for constructing optical images from Computational Fluid Dynamics (CFD) solutions. During the period from 1 Nov. 1992 - 30 Jun. 1993, research efforts have been concentrated in improving these techniques.

Yates, Leslie A.↗

Complex-valued acquisition of the diffraction imaging by incoherent quasimonochromatic light without a support constraint

A scheme for complex-valued acquisition of the diffraction imaging with quasimonochromatic incoherent light is theoretically proposed. The main idea is to project the real and the imaginary parts of a Fraunhofer diffraction field on intensity distributions, respectively, with the use of a {pi}/2 phase-changing plate. The whole procedure is iterative algorithm free and needs no a priori knowledge of an arbitrary object. A numerical experiment and a quantitative confirmation are also given. To our knowledge, it was the first physical proposal for the complex-valued acquisition of a diffraction imaging by two-dimensional coherent patterns with thermal illumination.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advances in imaging, scattering, spectroscopy, and machine learning-aided approaches for multiscale characterization of cementitious systems

Recent progress in methods used in the multiscale characterization of cementitious systems is reviewed, focusing on advances in imaging, scattering, and spectroscopy. The review includes relevant applications and developments in machine learning and other data analytics approaches to enhance characterization. Developments in imaging using light and electron microscopy as well as x-ray (i.e., from synchrotron) methods are summarized. Updates include scanning electron microscopy (SEM), transmission electron microscopy (TEM), tomography, and holography. A critical overview of spectroscopy (e.g., MAS NMR, Raman) and scattering (e.g., neutron, x-ray, synchrotron x-ray) methods is provided, and the intersection of these with imaging is developed (e.g., Raman imaging). Additionally, the paper summarizes recent developments in and implementations of state-of-the-art machine-learning algorithms and data analytics methods for automated, systematic, and/or quantitative analyses of image data sets. The review considers but is not limited to the application of these methods for investigating the hydration and microstructure development of cement phases, low-carbon-footprint cements (e.g., limestone calcined clay cements, LC3), environmental interactions (e.g., ASR) and model systems. Finally, the present work provides a critical presentation of advances in characterization methods that link together the composition and multiscale structure of cementitious materials.

42 ENGINEERING↗

Cathodoluminescence of Al/x/Ga/1-x/As grown by liquid-phase epitaxy

Small-area contrast fluctuations observed in cathodoluminescence-mode SEM images of thin Al(x)Ga(1-x)As layers grown by liquid-phase epitaxy on GaAs:Cr substrates are attributed to local variations in alloy composition. Quantitative estimates of the composition excursions are obtained from the variations in CL intensity by calibration against compositions known from electron-probe microanalysis. In a typical sample, the CL variations are shown to correspond to peak-to-peak fluctuations of about 1 at. % of Al and occur over irregular regions generally in the range 6-20 microns in diameter.

Levin, E. R.↗

A Frequency Domain Methodology for Quantitative Evaluation of Diffuse Wavefield With Applications to Seismic Imaging

Abstract Ambient Noise Imaging (ANI) of subsurface structures relies on seismic interferometry of diffuse seismic wavefields. However, the lack of effective methods to quantify and identify highly diffuse waves hampers applications of ANI, particularly in evaluating seismic attenuation and monitoring structural changes with high temporal resolution. Conventional ANI approaches require data normalization, which effectively suppresses the non‐diffuse component with large amplitude but also results in significant loss of amplitude and phase information in the continuous seismic records. In this study, we propose a frequency domain method to quantitatively evaluate the degree of diffuseness of seismic wavefields by analyzing their statistical characteristics of modal amplitudes for stationarity and randomness. Tests on synthetic waveform and field nodal records show that the proposed method can effectively distinguish between diffuse and non‐diffuse waveforms for either single‐ or three‐component data. As an application, we identify a 60‐s‐long diffuse coda of a local M 2.2 earthquake recorded by a dense nodal array on the San Jacinto Fault Zone, and successfully extract high‐quality dispersion curve andQ‐value without performing data normalization. These results are consistent with those obtained by conventional methods that assess the correlation between coherency and the Green's function, and by modeling ballistic waves generated by road traffic. Our proposed method can advance the imaging of subsurface velocity and attenuation structures as well as monitoring temporal changes for scientific studies and engineering applications.

Geochemistry & Geophysics↗

SU-E-J-154: Image Quality Assessment of Contrast-Enhanced 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

Purpose: This study presents quantitative and qualitative assessment of the image qualities in contrast-enhanced (CE) 3D-CT, 4D-CT and CE 4D-CT to identify feasibility for replacing the clinical standard simulation with a single CE 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. Methods: Ten PDA patients were enrolled and underwent three CT scans: a clinical standard pair of CE 3D-CT immediately followed by a 4D-CT, and a CE 4D-CT one week later. Physicians qualitatively evaluated the general image quality and regional vessel definitions and gave a score from 1 to 5. Next, physicians delineated the contours of the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (CE 3D-CT, 50% phase for 4D-CT and CE 4D-CT), then high density areas were automatically removed by thresholding at 500 HU and morphological operations. The pancreatic tumor contrast-to-noise ratio (CNR), signal-tonoise ratio (SNR) and conspicuity (C, absolute difference of mean enhancement levels in P and T) were computed to quantitatively assess image quality. The Wilcoxon rank sum test was used to compare these quantities. Results: In qualitative evaluations, CE 3D-CT and CE 4D-CT scored equivalently (4.4±0.4 and 4.3±0.4) and both were significantly better than 4D-CT (3.1±0.6). In quantitative evaluations, the C values were higher in CE 4D-CT (28±19 HU, p=0.19 and 0.17) than the clinical standard pair of CE 3D-CT and 4D-CT (17±12 and 16±17 HU, p=0.65). In CE 3D-CT and CE 4D-CT, mean CNR (1.8±1.4 and 1.8±1.7, p=0.94) and mean SNR (5.8±2.6 and 5.5±3.2, p=0.71) both were higher than 4D-CT (CNR: 1.1±1.3, p<0.3; SNR: 3.3±2.1, p<0.1). The absolute enhancement levels for T and P were higher in CE 4D-CT (87, 82 HU) than in CE 3D-CT (60, 56) and 4DCT (53, 70). Conclusions: The individually optimized CE 4D-CT is feasible and achieved comparable image qualities to the clinical standard simulation. This study was supported in part by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗