Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A 980 nm pseudomorphic single quantum well laser for pumping erbium-doped optical fiber amplifiers

The authors have fabricated ridge waveguide pseudomorphic InGaAs/GaAs/AlGaAs GRIN-SCH SQW (graded-index separate-confinement-heterostructure single-quantum-well) lasers, emitting at 980 nm, with a maximum output power of 240 mW from one facet and a 22 percent coupling efficiency into a 1.55-micron single-mode optical fiber. These lasers satisfy the requirements on efficient and compact pump sources for Er3+-doped fiber amplifiers.

Larsson, A.↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 2 – Transient modeling and pump-down path selection

Low-pressure conditions required for operation of helium cryogenic systems below the normal boiling point (i.e. 4.2 K) are established through a transient process, commonly referred to as ‘pump-down’. This process is defined as the transition from pressures above atmospheric conditions to the saturation pressure which corresponds to a specified operational temperature. The FRIB 2 K system consists of five cryogenic centrifugal compressors which are operated in series. Historically, the pump-down process path has been established through empirical methods and system operator experience. Investigation into the pump-down process at FRIB aimed to develop a pump-down methodology which relies on theoretical model predictions rather than empirically developed process paths. Ensuring stable operation during the pump-down process involved application of a centrifugal compressor performance prediction model, which is described in Part 1 of this paper. Compressor performance maps can be directly used to evaluate the stability of a selected pump-down path and anticipate the overall reliability of the selected path. In conjunction with the compressor performance maps, a system pressure model was developed to estimate the transient pressure response during the pump-down process. Lastly, an explicit equation was developed to establish a mass flow rate profile for the pump-down process. Implementation of the presented methodology (including the developed models) allows for the system operator to determine a continuous pump-down path which maintains compressor stability while conforming to overall system capabilities. Altogether, the methodology presented has resulted in simplification of transient pump-down operations and increased the reliability, stability and efficiency of the pump-down process.

Compressor train control↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

Efficient baffle prevents oil backstreaming in diffusion pumps

High vacuum diffusion pump baffle, positioned immediately above pump stack, prevents vaporized pumping oil from entering and contaminating test chamber. Pumping vapors are collected and condensed on the baffle and flow back to pump base reservoir.

Meneghetti, J. R.↗

Efficient energy extraction from a diode-pumped Q-switched Tm,Ho:YLiF4 laser

The operation of a diode-laser pumped thulium, holmium yttrium-lithium-fluoride laser (Tm,Ho:YLF) in Q-switched mode is reported. Output energies of 200 microjoules in pulses of 22 ns duration are recorded at Q-switch frequencies commensurate with an effective upper laser level lifetime of 6 ms. This lifetime is appreciably longer than that observed in other hosts permitting stored energy extraction of 64 percent, close to the projected maximum performance from these materials.

Mcguckin, B. T.↗

High Output Maximum Efficiency Resonator

A diode pumped, solid state laser is provided that can produce over 16 billion, 15 mJ, 10 ns Q-Switched laser pulses with a low measured decay rate. The laser can be integrated into a global biomass measuring instrument, and mounted on the International Space Station (ISS).

Stysley, Paul R.↗

Magnetic Heat Pump Containing Flow Diverters

Proposed magnetic heat pump contains flow diverters for suppression of undesired flows. If left unchecked, undesired flows mix substantial amounts of partially heated and partially cooled portions of working fluid, effectively causing leakage of heat from heated side to cooled side. By reducing leakage of heat, flow diverters increase energy efficiency of magnetic heat pump, potentially offering efficiency greater than compressor-driven refrigerator.

Howard, Frank S.↗

Fabrication and test of a space power boiler feed electromagnetic pump. Part 2: Test facility and performance test

A three-phase helical induction electromagnetic pump, designed for the boiler-feed pump of a potassium Rankine-cycle space power system, was built and tested. The pump was tested over a range of potassium temperatures from 900 to 1400 F, flow rates from 0.75 to 4.85 lb/sec, developed pressures up to 340 psi, net positive suction heads (NPSH) from 1 to 22 psi, and NaK coolant temperatures from 800 to 950 F. The maximum efficiency at the pump design point of 3.25 lb/sec flow rate, 240 psi developed pressure, 1000 F potassium inlet temperature, and 800 F NaK coolant temperature was 16.3 percent. The tests also showed successful operation of the pump at an NPSH as low as 1.5 psi without cavitating.

Powell, A. H.↗

Development of a preprototype times wastewater recovery subsystem

A three-man wastewater recovery preprototype subsystem using a hollow fiber membrane evaporator with a thermoelectric heat pump to provide efficient potable water recovery from wastewater on extended duration space flights was designed, fabricated, and tested at one-gravity. Low power, compactness and gravity insensitive operation are featured in this vacuum distillation subsystem. The tubular hollow fiber elements provide positive liquid/gas phase control with no moving parts, and provide structural integrity, improving on previous flat sheet membrane designs. A thermoelectric heat pump provides latent energy recovery. Application and integration of these key elements solved problems inherent in all previous reclamation subsystem designs.

Roebelen, G. J., Jr.↗

Regional suitability of heating tower heat pumps based on technical and economic performance maps

The heating tower heat pump (HTHP) technology is evolving rapidly due to its high performance in summer and frost-free characteristic in winter. However, lacking comprehensive comparisons between the HTHP and conventional methods, such as air-source heat pump (ASHP), and chiller and boiler, greatly limits its applications. To address this problem, this paper carries out technological and economic performance analyses of the three systems in 353 locations over China by the processes of building load calculation, system sizing, annual simulation, performance comparison, and demonstration. Energy saving principle and potential of the HTHP are presented and explained. Based on that, economic performance comparison is conducted by considering the energy conversion efficiency and prices. The results show that the HTHP has advantage over the ASHP in most locations in China. The improvement in annual coefficient of performance (COP) is about 10% to 20%. For the locations in southwest China like Chongqing, the improvement is also less than 10% due to the large regeneration penalization in winter and small difference between dry-bulb and wet-bulb temperature in summer. The annual COP of the HTHP is 10% to 23% higher than that of the chiller and boiler in hot summer and cold winter zone, and cold zone. However, the HTHP shows no advantage over the chiller and boiler in severe cold zone because of the low efficiency of heat pump in winter, neither in hot summer and warm winter zone due to the small heating load. Based on the results, technical and economic performance maps are developed to guide the application of the HTHP in different climate regions.

heating tower heat pump, air-source heat pump, chi↗

Initial Design and Experimental Results of a Novel Near-Isothermal Compressor for Heat Pump Applications

In efforts to increase the efficiency of residential and commercial air conditioners and heat pumps, it is found that the compressor has the highest electrical energy usage of the system. Therefore, it is appropriate to try to increase the efficiency of this component to reduce its energy usage. Another challenge with heat pump design is that some compressor types have drawbacks that make modulation difficult. To answer these challenges, we are developing an isothermal liquid compressor. The compressor uses propylene glycol to compress carbon dioxide. In the compression chamber the propylene glycol can enter either from the bottom to create a liquid piston for compression or it can enter through a spray nozzle at the top of the chamber. In the latter case, heat transfer from the gas to be compressed to the liquid droplets is high. This allows near isothermal operation of the compressor, which increases the efficiency by 17% to 30%, compared to adiabatic compression. In addition, the isothermal liquid compressor enables very efficient and simple part load modulation.Experimental results demonstrating the operation of the liquid compressor are presented. Initial data demonstrated a temperature rise of 7 K at pressure ratios of almost 4. For comparison at the same initial pressure, temperature, and pressure ratio, adiabatic compression would result in a temperature increase of approximately 70 K. Plotting data on a P-h diagram demonstrates that the compression started at superheated state and ended in supercritical state. Testing was later performed with repeated compressions in the superheated region of the P-h diagram at liquid flow rates of 2 x 10-3 m3/min and 2 x 10-3 m3/min to understand the limitations of the prototype for use with an actual heat pump system. This work demonstrated a novel cycle on a T-s diagram. Results from this work will be used to develop a second-generation prototype where more rapid cycling is possible.

Kowalski, Steve↗

Infrared up-conversion with resonantly two-photon pumped metal vapors

Observation of efficient up-conversion of low-level IR radiation near 10 microns to the near ultraviolet. Radiation at 9.26 micron is converted to 3305 A with a photon conversion efficiency of 58% and a corresponding power gain of 16.2. The process employs resonant two-photon pumping of the nonallowed 3s-3d transition in Na.

Bloom, D. M.↗

Pump Propels Liquid And Gas Separately

Design for pump that handles mixtures of liquid and gas efficiently. Containing only one rotor, pump is combination of centrifuge, pitot pump, and blower. Applications include turbomachinery in powerplants and superchargers in automobile engines. Efficiencies lower than those achieved in separate components. Nevertheless, design is practical and results in low consumption of power.

Harvey, Andrew↗

Incompressible Navier-Stokes Calculations in Pump Flows

Flow through pump components, such as the SSME-HPFTP Impeller and an advanced rocket pump impeller, is efficiently simulated by solving the incompressible Navier-Stokes equations. The solution method is based on the pseudo compressibility approach and uses an implicit-upwind differencing scheme together with the Gauss-Seidel line relaxation method. The equations are solved in steadily rotating reference frames and the centrifugal force and the Coriolis force are added to the equation of motion. Current computations use one-equation Baldwin-Barth turbulence model which is derived from a simplified form of the standard k-epsilon model equations. The resulting computer code is applied to the flow analysis inside an 11-inch SSME High Pressure Fuel Turbopump impeller, and an advanced rocket pump impeller. Numerical results of SSME-HPFTP impeller flow are compared with experimental measurements. In the advanced pump impeller, the effects of exit and shroud cavities are investigated. Flow analyses at design conditions will be presented.

Kiris, Cetin↗

Qualification and Performance of a High-Efficiency Laser Transmitter for Deep-Space Optical Communications

A high-power Laser Transmitter Assembly (LTA) was developed to support the Deep Space Optical Communications (DSOC) technology demonstration being developed by the Jet Propulsion Laboratory. NASA’s Psyche Mission plans to host the DSOC flight subsystem for testing space-to-ground high-bandwidth laser communications en route to the 16 Psyche asteroid. We review the design, performance, and qualification of the LTA Engineering Model and Flight Model (EM and FM) delivered to JPL. The LTA uses a master-oscillator power amplifier (MOPA) design and delivers up to 4.5 W at 1550 nm, with a highly efficient, cladding-pumped, polarization-maintaining erbium-ytterbium fiber amplifier. The master oscillator generates a range of pulse widths and repetition rates to support modulation formats from 16- to 128-PPM for optical data transmission at >100 Mbps. The LTA was designed for high reliability and radiation hardness, and includes redundant signal and pumping paths to reduce single points of failure, hardware interlocks to ensure safe operation and protection against damage, closed-loop control of optical power, and detailed health and status via telemetry. The LTA EM and FM were subjected to unit-appropriate space qualification testing. We describe the performance testing of the EM and FM, for the characterization of key metrics such as wavelength stability, signal linewidth, optical pulse width, jitter, and extinction ratio, and polarization extinction ratio. The management of optical nonlinearities (self-phase modulation, Brillouin scattering, or pulse-to-pulse energy variation), which could result in an optical link penalty or damage to the LTA, is also detailed, and factors affecting the power efficiency are discussed.

Jaques, J.↗

Ring-Down Spectroscopy for Characterizing a CW Raman Laser

.A relatively simple technique for characterizing an all-resonant intracavity continuous-wave (CW) solid-state Raman laser involves the use of ring-down spectroscopy. As used here, characterizing signifies determining such parameters as threshold pump power, Raman gain, conversion efficiency, and quality factors (Q values) of the pump and Stokes cavity modes. Heretofore, in order to characterize resonant-cavity-based Raman lasers, it has usually been necessary to manipulate the frequencies and power levels of pump lasers and, in each case, to take several sets of measurements. In cases involving ultra-high-Q resonators, it also has been desirable to lock pump lasers to resonator modes to ensure the quality of measurement data. Simpler techniques could be useful. In the present ring-down spectroscopic technique, one infers the parameters of interest from the decay of the laser out of its steady state. This technique does not require changing the power or frequency of the pump laser or locking the pump laser to the resonator mode. The technique is based on a theoretical analysis of what happens when the pump laser is abruptly switched off after the Raman generation reaches the steady state. The analysis starts with differential equations for the evolution of the amplitudes of the pump and Stokes electric fields, leading to solutions for the power levels of the pump and Stokes fields as functions of time and of the aforementioned parameters. Among other things, these solutions show how the ring-down time depends, to some extent, on the electromagnetic energy accumulated in the cavity. The solutions are readily converted to relatively simple equations for the parameters as functions of quantities that can be determined from measurements of the time-dependent power levels. For example, the steady-state intracavity conversion efficiency is given by G1/G2 1 and the threshold power is given by Pin(G2/G1)2, where Pin is the steady-state input pump power immediately prior to abrupt switch-off, G1 is the initial rate of decay of the pump field, and G2 is the final rate of decay of the pump field. Hence, it is possible to determine all the parameters from a single ring-down scan, provided that the measurements taken in that scan are sufficiently accurate and complete.

Matsko, Andrey↗

A Reversible Thermally Driven Pump for Use in a Sub-Kelvin Magnetic Refrigerator

A document describes a continuous magnetic refrigerator that is suited for cooling astrophysics detectors. This refrigerator has the potential to provide efficient, continuous cooling to temperatures below 50 mK for detectors, and has the benefits over existing magnetic coolers of reduced mass because of faster cycle times, the ability to pump the cooled fluid to remote cooling locations away from the magnetic field created by the superconducting magnet, elimination of the added complexity and mass of heat switches, and elimination of the need for a thermal bus and single crystal paramagnetic materials due to the good thermal contact between the fluid and the paramagnetic material. A reliable, thermodynamically efficient pump that will work at 1.8 K was needed to enable development of the new magnetic refrigerator. The pump consists of two canisters packed with pieces of gadolinium gallium garnet (GGG). The canisters are connected by a superleak (a porous piece of VYCOR glass). A superconducting magnetic coil surrounds each of the canisters. The configuration enables driving of cyclic thermodynamic cycles (such as the sub-Kelvin Active Magnetic Regenerative Refrigerator) without using pistons or moving parts.

Miller, Franklin K.↗