Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse shaping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Identifying Interaction Location in SuperCDMS Detectors

The Super Cryogenic Dark Matter Search (SuperCDMS) experiment uses silicon and germanium particle detectors operated at temperatures of ∼ 30 mK to search for Weakly Interacting Massive Particles (WIMPs), which are candidate dark matter particles that interact weakly with nuclei in the detectors. In operating these detectors, it is required not only to measure the energy of the interaction between the WIMP and the nuclei, but also to reconstruct where the interaction occurred, as the location can be used to separate background interactions from signal and to correct for variations with the location of the energy response. In this project, we, as a team from the University of Minnesota, aim to address the problem of accurately reconstructing the locations of interactions in the SuperCDMS detectors using machine learning methods. The dataset we provided here includes interactions at thirteen different locations from test data taken at the University of Minnesota. For each interaction, a set of parameters was extracted from the signals from each of the five sensors. These parameters represent information known to be sensitive to interaction location, including the relative timing between pulses in different channels, and features like the pulse shape. The relative amplitudes of the pulses are also relevant but due to instabilities in amplification during the test, this data is not included. The parameters included for each interaction are described in our project document. For more details, feel free to check our Github page: https://fair-umn.github.io/FAIR-UMN-CDMS/

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Outburst from 4U 1145-619: A Transient X-Ray Pulsar

4U 1145-619, a 293 second Be/X-ray pulsar, was discovered with Uhuru (Forman 1978, ApJS, 38, 357) and first identified as a pulsar in 1977 with Ariel V (White 1978, Nature, 274, 664). From 1991 to 1998, BATSE observed 4U 1145-619 in a series of 12 periodic outbursts, each with durations of 8-30 days. Combining these data with previously published results yielded an outburst ephemeris of T(sub out) = MJD 448871.s (+/- 0.6) +/- 186.68 (+/- 0.05)E(sub out), Where T(sub out) is the time of peak intensity and E(sub out) is the cycle number. Most outbursts occur within phases +/- 0.1 of the outburst ephemeris. Pulse frequency measurements were consistent with a long-term average frequency derivative of the first derivative of v = -3 x 10(exp -14) Hz/s. Most outbursts reached peak total fluxes of approximately equal 100 mCrab (20-50 keV) and had 20-50 keV r.m.s. pulse fractions of about 30%. (A pulse fraction of 70% was observed for one outburst). Two outbursts reached 20-50 keV peak total fluxes of 550 mCrab, but had very different 20-50 keV pulse fractions of about 30% and about 50%. Three outbursts with peak total fluxes of 120, 134, and 180 mCrab, had r.m.s. pulse fractions of about 28%, 34%, and 52%. During the brightest 3 outbursts observed with BATSE, the pulse frequency increased. Fainter outbursts observed with BATSE appeared to reach peak intensity at a later phase (relative to the ephemeris) than brighter outbursts, and were typically not detectable at the expected times of peak intensity. The pulse profile showed significant intensity and energy dependent pulse shape variations. We present histories of pulse frequency, 20-50 keV intensity, and pulse profiles.

Wilson, Colleen↗

Proton discrimination in CLYC for fast neutron spectroscopy

The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method and circuit for shaping laser output pulses

The invention is a method and circuit for shaping laser pulses 17' in which a laser medium 12' in a laser resonator 10' that includes a Q-switch 14' and polarizer 13' which act in combination to control the loss of the resonator 10' and provide the laser output 17' representative of such loss. An optical diode 22' senses the level of the output pulse 17' and provides an output signal 23' that when amplified is used with a control voltage from a supply 29' provide a control signal 19' which is applied to Q-switch 14' to control the shape of the output pulse 17' by adjusting its length.

Barnes, Norman P.↗

A Comprehensive Study of Pulse Profile Evolution in SGR 1806-20 and SGR 1900+14 with the Rossi X-ray Timing Explorer Proportional Counter Array

Soft gamma repeaters undergo pulse profile changes in connection with their burst activity. Here we present a comprehensive pulse profile history of SGR 1806-20 and SGR 1900+14 in three energy bands using Rossi X-Ray Timing Explorer/Proportiona1 Counter Array observations performed between 1996 and 2001. Using the Fourier harmonic powers of pulse profiles, we quantify the pulse shape evolution. Moreover, we determined the rms pulsed count rates (PCRs) of each profile. We show that the pulse profiles of SGR 1806-20 remain single pulsed, showing only modest changes for most of our observing span, while those of SGR 1900+14 change remarkably in all energy bands. Highly significant pulsations from SGR 1900+ 14 following the 1998 August 27 and 2001 April 18 bursts enabled us to study not only the decay of PCRs in different energy bands but also their correlations with each other.

Gogus, Ersin↗

Development of digital electronics for the search of SHE nuclei using GARIS-II/III at RIKEN

This work describes the implementation of a digital data acquisition system for the search and study of short-lived isotopes or superheavy elements at the GARIS-III separator at the RIKEN Nishina Center. Here a reduction to 26 ± 0.5 keV in the average value of the Full Width at Half Maximum of the alpha spectrum at 7.133 MeV was achieved, combined with a reduction of the dead time of the overall system to around a few tens of nanoseconds for the detection of very fast decay chains. Moreover, we measured a reduction of the background induced by particles crossing the implantation detector using pulse shape analysis techniques. The detail of the optimization and analysis will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

6 Li-loaded liquid scintillators produced by direct dissolution of compounds in diisopropylnaphthalene (DIPN)

Here, this paper describes preparation of 6 Li-loaded liquid scintillators by methods involving direct dissolution of 6Li salts in the commercial diisopropylnaphthalene (DIPN) solvent, without the formation of water-in-oil emulsions. Methods include incorporation of 6 Li that, unlike previously reported formulations, does not require additions of water or a strong acid such as hydrochloric acid (HCl). Results of the conducted experiments show that dissolution of aromatic and aliphatic 6 Li salts in DIPN can be easily achieved at 0.1%–0.3% by weight of atomic 6 Li, using small additions of waterless surfactants, or mild carboxylic acids. An alternative way suggests incorporation of 6 Li as a part of a surfactant molecule that can be dissolved in DIPN without any solubilizing additions. Proposed methods enable preparation of efficient 6 Li-loaded liquid scintillators that, at a large scale of 50 cm, exhibit good pulse shape discrimination (PSD) properties combined with up to 107% of light output and up to 115% of the attenuation length measured relative to standard undoped EJ-309 liquid scintillator.

36 MATERIALS SCIENCE↗

Efficient Prompt Scintillation and Fast Neutron-Gamma Ray Discrimination Using Amorphous Blends of Difluorenylsilane Organic Glass and in-situ Polymerized Vinyltoluene

High performance radiation detection materials are an integral part of national security, medical imaging, and nuclear physics applications. Those that offer compositional and manufacturing versatility are of particular interest. In this work, we report a new family of radiological particle-discriminating scintillators containing bis(9,9-dimethyl-9H-fluoren-2- yl)diphenylsilane (compound “P2”) and in-situ polymerized vinyltoluene (PVT) that is phase stable and mechanically robust at any blend ratio. The gamma-ray light yield increases nearly linearly across the composition range, to ~16,400 photons/MeV at 75 % wt. P2. These materials are also capable of γ/n pulse shape discrimination (PSD) and between 20-50 % P2 loading are competitive with the PSD quality of commercially-available plastic scintillators. The 137 Cs scintillation rise and decay times are sensitive to P2 loading and approach the values for “pure” P2. Additionally, the radiation detection performance of P2-PVT blends can be made stable in 60°C air for at least 1.5 months with the application of a thin film of poly(vinylalcohol) to the scintillator surfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-system model for enhanced operational performance and flexibility on OMEGA EP

The development of laser performance models having real-time prediction capability for the OMEGA EP laser system has been essential in meeting requests from its user community for increasingly complex pulse shapes that span a wide range of energies. The laser operations model PSOPS provides rapid and accurate predictions of OMEGA EP laser-system performance in both forward and backward directions, a user-friendly interface and rapid optimization capability between shots. We describe the model’s features and show how PSOPS has allowed real-time optimization of the laser-system configuration in order to satisfy the demands of rapidly evolving experimental campaign needs. We also discuss several enhancements to laser-system performance accuracy and flexibility enabled by PSOPS.

42 ENGINEERING↗

Systematic evaluation of fast neutron sensing with Cesium Hafnium Chloride

Cesium Hafnium Chloride (CHC) is a promising new scintillator for dual mode sensing of both neutrons and gamma-rays. The high chlorine content allows for both 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reaction channels leading to reliable detection of fast neutrons. By utilizing pulse shape discrimination (PSD), these neutron interactions may be reliably separated from gamma-ray signals with a high figure-of-merit (FOM) after optimization of the PSD algorithm. Here, in this study, the PSD algorithm settings for CHC were systematically investigated using a bare 252 Cf and a lead shielded plutonium beryllium neutron source. It was found that the PSD algorithm settings affects both the FOM and the neutron detection efficiency, but a FOM as high as 4.5 for alpha particles was observed in one data processing scenario. Further, an intrinsic 5 parts per million alpha emitting contamination was observed in the sample, which we attribute to natural uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a boron-loaded deuterated liquid scintillator for fast and thermal neutron detection

The preparation and characterization of novel boron-loaded deuterated liquid scintillators (BLDLS) are presented for the first time to investigate the performance of a detector sensitive to both fast and thermal neutrons intended for future neutron spectroscopy measurements. Three deuterated toluene-based scintillation cocktails were produced, one without boron, one loaded with ortho-carborane (natural boron isotopic abundance), and one with 96 wt% 10B enriched ortho-carborane. General optical and material properties were analyzed to include the composition, density, index of refraction, photoluminescence emission spectra, and absorbance spectra in addition to the relative light yield, resolution, relative efficiency, and pulse-shape-discrimination performance for all three scintillators and a hydrogen-based EJ-309 scintillator to evaluate the effects of boron loading in comparison with a common commercially-available scintillator and feasibility for future neutron spectroscopy measurements. Finally, the detection of shielded neutron sources was explored to capitalize on the 10B thermal neutron capture reaction. The results showed loading the scintillators with boron deteriorated the PSD performance slightly compared to the unloaded deuterated scintillator and resulted in a relative light yield loss of 26% and 41% for the 10B enriched and natural boron BLDLS, respectively. Lastly, the BLDLS have a higher relative detection efficiency than the unloaded deuterated scintillator for shielded neutron sources, based on total count rate, a desirable characteristic for missions related to finding and characterizing illicitly-trafficked special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

Control of Energy Transport and Transduction in Photosynthetic Down-Conversion (Final Technical Report)

The research conducted under this contract focused on three areas related to control of energy transport and transduction in natural and synthetic light harvesting systems: (1) experimental and theoretical studies exploring the use of ultrafast laser pulse shaping to manipulate the initially excited states of multi-chromophore biological light harvesting networks and influence the early time energy transfer and electronic and vibrational relaxation pathways, (2) fundamental theoretical developments aimed at computing and analyzing the dynamics of excitations of complex heterogeneous environments and nano structures, and (3) joint experimental and theoretical design studies of artificial light harvesting materials exploring the influence of incorporating different types of organic layers in low dimensional lead halide perovskite materials on their hot carrier relaxation dynamics, and theoretical studies of the design of nano structured light harvesting antenna systems. These research projects supported the training of three theoretical and computational graduate students, one experimental graduate student, and one experimental post-doctoral researcher. The research has been published in seven peer reviewed papers and presented at several international meetings and workshops.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron Imaging Using Organic Glass Scintillators

In this work, we develop of a compact neutron imaging system based on organic glass scintillator and silicon photomultiplier arrays. The recently developed organic glass scintillator has excellent neutron and gamma-ray detection efficiency and exhibits pulse shape discrimination capability that is nearly as good as current state-of-the-art materials such as trans-stilbene. We have cast and characterized 6 mm by 6 mm by 50 mm bars of organic glass in our laboratory. When coupled to a silicon photomultiplier array, these bars demonstrated better energy and timing resolution than the stilbene organic scintillator. Here, this performance makes organic glass an ideal material for a compact neutron imaging system, which must resolve neutron scatter events on a sub-nanosecond time scale. We have demonstrated neutron imaging with bars of organic glass scintillator coupled to arrays of silicon photomultipliers. Additional bars of organic glass will be implemented into the system to improve the efficiency and imaging performance. The resulting system will be demonstrated using 252 Cf and PuBe neutron sources in our laboratory. In addition, we will compare imaging performance to other compact neutron imaging systems that exist in literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Melt Blending: A Tool to Simplify Plastic Scintillator Synthesis

Plastic scintillators are widely used as radiation detection media in homeland security and nuclear physics applications. Their attributes include low cost, scalability to large detector volumes, and additive compounding to enable additional material and detection features, such as pulse shape discrimination (PSD), gamma-ray spectroscopy, aging resistance, and coincidence timing. However, traditional chemically cured plastic scintillators (CCS) require long reaction times, and hazardous wet chemical procedures performed by specially trained personnel, and can leave residual monomer, resulting in deleterious optical and material properties. Here, we synthesize melt blended scintillators (MBSs) in 2.5 days using easily accessible solid-state compounding of commercially-available poly(styrene) with 30–60 wt% fluorene-based compound “P2” to create monolithic detectors with < 100 ppm residual monomer, in several form factors. Further, the best scintillation performance was recorded for 60 wt% P2 in Styron 665, including gamma-ray light yield 139% of EJ- 200 commercial scintillator and PSD figure of merit (FOM) value of 2.65 at 478 keVee, approaching P2 organic glass scintillator (OGS). The capability of MBS to generate fog-resistant scintillators and poly(methyl methacrylate) (PMMA)-based scintillators for use in challenging environments is also demonstrated.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Comparative analysis of new crystal and plastic scintillators for fast and thermal neutron detection

This paper considers scintillation and physical properties of efficient organic scintillators tested as single crystals and as components of plastics with pulse shape discrimination (PSD). For the first time, single crystals of 9,9-dimethyl-2-phenyl-9H-fluorene (PhF) were grown for studies of the basic scintillation properties of this new compound. Comparison to classical organic crystals, like anthracene, trans-stilbene, and p-terphenyl, and to more recently introduced organic glass showed that the new crystal belongs to a group of the most efficient scintillators, with light output exceeding that of trans-stilbene and PSD comparable to that of p-terphenyl. Furthermore, additional studies were conducted to evaluate scintillation performance and physical properties, like hardness and dye leaching, of plastic scintillators prepared with PhF, organic glass, and liquid diisopropylnaphthalene (DIPN) that were considered as examples for potential replacement of PPO (2,5-diphenyloxazole) in current commercial PSD plastic scintillators. Comparison of the highest performing plastic scintillators prepared with these dyes shows that PhF formulations produced a record light output (LO) increase of 69 % relative to EJ-200. Similar improvements obtained with 6 Li-loaded formulations showed that future development of PSD plastics should not be limited to use of PPO but must involve the search and exploration of new efficient dyes that may lead to discovery of much brighter organic scintillators with improved physical properties required for fast and thermal neutron detection, fast neutron spectroscopy, and antineutrino detection applications.

9,9-dimethyl-2-phenyl-9H-fluorene↗

Generation of Bright Soft X-ray Laser Beams (Final Report)

The project goal was to demonstrate new compact soft x-ray lasers emitting high energy ultrashort pulses at shorter wavelengths and increased repetition rates by amplification in atomic transitions in high density laser-created plasmas. To demonstrate these lasers we developed new high power solid state lasers. The project succeeded in demonstrating the shortest wavelength compact soft x-ray laser to date, 6.85 nm wavelength, and the highest repetition rate table-top soft x-ray laser, 400 Hz. We also applied these compact soft x-ray laser sources to determine the composition of materials with nanoscale resolution using a new technique that combines soft x-ray laser ablation with mass spectrometry, and we demonstrated that these lasers are capable of acquiring nanoscale resolution holograms with picosecond time resolution. The combination of an increased pumping efficiency with increased repetition rates can yield soft x-ray laser beams with an unprecedented average power on a table-top for applications demanding a high photon flux. We have demonstrated that the efficiency of plasma-based laser-pumped soft x-ray lasers can be significantly increased by detailed pulse shaping of the pump laser using a new pulse synthesizer. Results include the demonstration of 18.9 nm wavelength laser operation at a record 400 Hz repetition rate, and the extension of repetitive gain-saturated plasma-based table-top x-ray lasers to the shortest wavelength to date, 6.85 nm. Laser amplification was also observed at wavelengths as short at 5.8 nm by isolectronic scaling in Ni-like lanthanide ions. We have also conducted simulations to explore the possibility of demonstrating gain saturated atomic x-ray lasers near the carbon K-edge, in the “carbon window” for the first time. The work conducted under this program also includes the use of compact soft x-ray lasers in applications to problems of chemical interest, such as isotopic composition mapping of micron-size uranium particles with nanoscale resolution, and nanoscale resolution depth profiling analysis of CoNCN-coated electrodes for water oxidation catalysis. We also demonstrated single-shot high resolution soft x-ray Fourier transform holography over a broad 7 µm diameter field of view with ~ 5 ps temporal resolution.

74 ATOMIC AND MOLECULAR PHYSICS↗