Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse shape discrimination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Low energy light yield of fast plastic scintillators

Compact neutron imagers using double-scatter kinematic reconstruction are being designed for localization and characterization of special nuclear material. These neutron imaging systems rely on scintillators with a rapid prompt temporal response as the detection medium. As n-p elastic scattering is the primary mechanism for light generation by fast neutron interactions in organic scintillators, proton light yield data are needed for accurate assessment of scintillator performance. The proton light yield of a series of commercial fast plastic organic scintillators—EJ-200, EJ-204, and EJ-208—was measured via a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable deuteron breakup neutron source, target scintillators housed in a dual photomultiplier tube configuration, and an array of pulse-shape- discriminating observation scintillators, the fast plastic scintillator light yield was measured over a broad and continuous energy range down to proton recoil energies of approximately 50 keV. Furthermore, this work provides key input to event reconstruction algorithms required for utilization of these materials in emerging neutron imaging modalities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of neutron and gamma-ray cross-correlation functions with 4 He detectors

For the first time, the neutron and gamma-ray time-dependent cross-correlation distributions from spontaneous fission and (α, n) neutron sources are measured with the 4 He fast neutron detectors. The pulse shape discrimination technique based on charge comparison is utilized to discriminate between neutrons and gamma-rays in the identification of the four possible correlated pairs: (γ, γ), (n, n), (γ, n), and (n, n). Both total and individual cross-correlation functions are obtained, and their shapes can be easily distinguished among different neutron sources. The (n, n) and (γ, n) correlations are selectively analyzed and the peak position of the (n, n) and (γ, n) pairs shows a linear correlation with source-detector distance. Here, the measurements illustrate the feasibility of using 4 He detectors to identify nuclear materials and their geometrical configurations, as well as other applications in nuclear nonproliferation and safeguards. In particular, the (n, n) correlated data can be very clearly assayed even in the presence of significant gamma fields without the use of shielding.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Stilbene cell development to improve radioxenon detection

A prototype stilbene beta cell has been designed, manufactured, tested, and compared to a plastic scintillator beta cell used for nuclear explosion monitoring of radioxenon. Measurements of the four isotopes of interest show similar responses for both the plastic scintillator and stilbene cell. However, we show that the stilbene cell exhibits minimal memory effect (0.043%), a capability that is of interest in nuclear explosion monitoring because it improves detection sensitivity, allowing for decreased time between measurements. The resolution of the stilbene cell is improved slightly (2.2 keV at 129 keV) when compared to the plastic scintillator cell. The efficiency of the stilbene cell is lower than that of the plastic by an average 15%. These results suggest that an improvement in light collection are needed. Pulse shape discrimination analysis decreases the minimum detectable concentration by 1%. The use of this geometry allows for a simple replacement of the plastic cells currently used in the field versus a complete overhaul of the existing radioxenon monitoring stations.

Sivels, Ciara B.↗

A liquid scintillation detector for radioassay of gadolinium-loaded liquid scintillator for the LZ Outer Detector

© 2019 Elsevier B.V. We report on the design and performance of the LUX-ZEPLIN (LZ) “Screener”, a small liquid scintillator detector consisting of ≈23 kg of LAB-based gadolinium-loaded liquid scintillator (GdLS) to be used in the LZ Outer Detector. The Outer Detector will be filled with 17.3 tonnes of GdLS and will surround the central liquid xenon time projection chamber of LZ. Its primary function will be to tag neutron events in the liquid xenon which could mimic a WIMP dark matter signal. To meet the deadtime requirements for the Outer Detector, the radioimpurity levels in the GdLS must be kept below ≲0.07 mBq/kg. This background level corresponds to a rate of ≈50Hz above an energy threshold of 100 keV. The Screener was operated in the ultra-low-background environment of the former LUX water shield in the Davis Laboratory at the Sanford Underground Research Facility for radioassay of the GdLS. Careful selection of detector materials and use of ultra-low-background PMTs allows the measurement of a variety of radioimpurities. The 14C/12C ratio in the scintillator is measured to be (2.83±0.06(stat.)±0.01(sys.))×10 -17 . Use of pulse shape discrimination allows the concentration of isotopes throughout the 238U, 235U, and 232Th chains to be measured by fitting the collected spectra from α and β events. We find that equilibrium is broken in the 238U and 232Th chains and that a significant portion of the contamination in the GdLS results from decays in the 227Ac subchain of the 235U series. Predictions for the singles rate in the Outer Detector are presented. The rate from radioimpurities above 100 keV in the GdLS is estimated to be 97.9±6.4Hz, with 65.5±1.9Hz resulting from α-decays.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of proton-induced radiation damage on CLYC and CLLBC performance

Cerium-doped Cs 2 LiYCl 6 (CLYC) and Cs 2 LiLaBr x Cl 6-x (CLLBC) are scintillators in the elpasolite family that are attractive options for resource-constrained applications due to their ability to detect both gamma rays and neutrons within a single volume. Space-based detectors are one such application, however, the radiation environment in space can over time damage the crystal structure of the elpasolites, leading to degraded performance. We have exposed 4 samples each of CLYC and CLLBC to 800 MeV protons at the Los Alamos Neutron Science Center. The samples were irradiated with a total number of protons of 1.3 x 10 9 , 1.3 x 10 10 , 5.2 x 10 10 , and 1.3 x 10 11 , corresponding to estimated doses of 0.14, 1.46, 5.82, and 14.6 kRad, respectively on the CLYC samples and 0.14, 1.38, 5.52, and 13.8 kRad, respectively on the CLLBC samples. Here, we report the impact these radiation doses have on the light output, activation, gamma-ray energy resolution, pulse shapes, and pulse-shape discrimination figure of merit for CLYC and CLLBC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast-neutron response of LaBr 3 (Ce) and LaCl 3 (Ce) scintillators

The response of LaBr 3 (Ce) and LaCl 3 (Ce) scintillators to fast neutrons is investigated. Neutron-induced charged-particle reactions are observed in both materials when exposed to the fast neutrons produced by an AmBe source, with pulse-shape discrimination used to separate channels. LaBr 3 (Ce) is found to have the best separation between reaction channels, while LaCl 3 (Ce) has a significantly higher efficiency.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Boron-loaded organic glass scintillators

Herein we report the progress towards an organic glass scintillator with fast and thermal neutron sensitivity providing “triple” pulse shape discrimination (PSD) through the inclusion of a boron-incorporated aromatic molecule. Here, the commercially available molecule 2-(p-tolyl)-1,3,2-dioxaborinane (TDB) can be readily synthesized in one step using inexpensive materials and incorporated into the organic glass scintillator at 20% by weight or 0.25% 10 B by mass. In addition, we demonstrate that TDB can be easily scaled up and formulated into organic glass scintillator samples to produce a thermal neutron capture signal with a light yield equivalent to 120.4 ± 3.7 keVee, which is the highest value reported in the literature to date.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron response of the TLYC scintillator

The response of the recently developed Tl 2 LiYCl 6 (Ce) scintillator to neutrons was measured and the 35 Cl(n,p) channel observed in the material for the first time. The scintillator was exposed to a 252 Cf source mounted within a parallel-plate avalanche counter for fission-fragment coincident measurements. Proton- and -like events are selected with the pulse-shape discrimination technique. Additionally, comparison of energy-deposition and time-of-flight allows the quenching of the different channels to be assessed. The 6 Li(n,t) channel is found to have its energy quenched to 37(1)% relative to -ray detection, while the proton energy deposition spectrum is quenched to 60(1)%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Anisotropic neutron response of trans-stilbene and impact on a handheld dual particle imager

Here this manuscript details measurements of the anisotropic light-output response of trans-stilbene, henceforth referred to as stilbene, along the three primary crystal planes and analyzes how this anisotropic response impacts neutron image reconstruction in a handheld dual particle imager (H2DPI). A prototype H2DPI composed of stilbene pillars (6 x 6 x 50 mm 3 ) coupled to silicon photomultipliers was built and is capable of imaging both fast neutrons and gamma rays from kilogram quantities of special nuclear material. Stilbene was chosen as the scintillating medium for the imager because of its pulse shape discrimination capability, time resolution and relatively high light output. A drawback to using stilbene, however, is the anisotropic response. A recoiling proton from a neutron elastic-scattering event in stilbene will yield different amounts of scintillation light depending on the direction of the recoiling proton with respect to the crystal lattice. This manuscript analyzes how this anisotropic response impacts neutron image reconstruction in 4π. The light output in the three primary crystal planes of stilbene were independently measured 6–7 times for proton recoil energies ranging from 0.5–5.0 MeV using a quasi-monoenergetic time-of-flight neutron source. The measured light-output data in the three crystal planes were fit with a semi-empirical function based on Birks’ formula. These fits were used to reconstruct the location of a 252 Cf source in front of the imager (0°, -0.8°), to the left of the imager (-90°, -0.8°) and directly above the imager (0°, 90°) to determine if it is necessary to apply the directionally-dependent response of stilbene to accurately reconstruct source locations. A bootstrapping technique was applied to the measured data sets to produce 1000 images composed of 2000 cone projections for each source location and each measured light-output curve. List-mode maximum likelihood expectation maximization was applied to each image; the highest pixel location and the full width at half maximum (FWHM) were then recorded. The average and standard deviations of these parameters were taken for each set of images. The maximum difference in the average azimuthal pixel location when varying between the appropriate and incorrect light-output curves for the source locations at (0°, -0.8°) and (-90°, -0.8°) were respectively found to be 1.85 ± 1.39° and 2.03 ± 1.78°. All other pixel locations and FWHMs were within a single standard deviation of uncertainty. Taken together, the anisotropic response of stilbene has negligible impact on the neutron image reconstruction capability of the H2DPI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Organic glass scintillator bars with dual-ended readout

Organic glass scintillator (OGS) bars (6 × 6 × 50 mm 3 ) were melt-cast and characterized with dual-ended readout by silicon photomultiplier arrays. The results were compared to trans-stilbene bars of the same size. Energy resolution was measured via a 137 Cs Compton-coincidence experiment. Time resolution was determined via a 22 Na coincidence-timing experiment. Depth-of-interaction resolution was measured by moving a gamma ray fan beam along the major axis of the bars. Pulse shape discrimination capability and neutron light output were determined via a time-of-flight measurement of a 252 Cf source. The OGS bars exhibited better energy resolution at 478 keV (10.3 ± 0.5% vs. 11.2 ± 0.5%), better time resolution from 200–341 keVee (270 ps vs. 340 ps FWHM), slightly poorer depth-of-interaction resolution, poorer PSD performance, and higher neutron light output than the stilbene bars. Here, the low cost, ease of manufacturing, brightness, and excellent time resolution make OGS a strong candidate for use in compact radiation imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CLARION2-TRINITY: A Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a compact ASIC-based data acquisition system for neutron/$γ$ discrimination and spectroscopy with organic scintillators

Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methodology for the neutron time of flight measurement of 120-GeV proton-induced reactions on a thick copper target

Our methodology for the time-of-flight measurement of the neutron energy spectrum for a high-energy proton-beam-induced reaction was established at the Fermilab Test Beam Facility of the Fermi National Accelerator Laboratory. The 120-GeV proton beam with 3 × 10 5 protons/spill was prepared for event-by-event counting of incident protons and emitted neutrons for time-of-flight energy determination. An NE213 organic liquid scintillator (12.7 cm in diameter by 12.7 cm in length) was employed with a veto plastic scintillator and a pulse-shape discrimination technique to identify neutrons. Raw waveforms of NE213, veto and beam detectors were recorded to discriminate the effects of multi-proton beam events by considering different time windows. The neutron energy spectrum ranging from 10 to 800 MeV was obtained for a 60-cm-long copper target at 90° with respect to the beam axis. Finally our obtained spectrum was consistent with that deduced employing the conventional unfolding technique as well as that obtained in a 40-GeV/c thin-target experiment.

120-GeV proton↗

Tl 2 LiYCl 6 : Large Diameter, High Performing Dual Mode Scintillator

Tl 2 LiYCl 6 :Ce (TLYC) is a recently discovered dual mode gamma-ray and neutron scintillator. So far small crystals of this composition have been studied, but for practical applications with affordable price, large-scale crystals are required. In this work, we present successful efforts to grow crack-free single crystals with sizes up to $\varnothing$1" × 5.5". A variety of experimental techniques were employed to investigate the scintillation properties. A $\varnothing$1" × 1.2" TLYC cylinder has a light yield of 25,000 ph/MeV, and its energy resolution is better than 4% at 662 keV. The gamma equivalent energy (GEE) produced by thermal neutron is 1.89 MeVee, along with a neutron induced light yield of 47,000 ph/n. Pulse shape discrimination (PSD) between gamma-rays and neutrons has been successfully shown with a current Figure-of-Merit (FOM) of 2.4. This paper explores the crystal growth, scintillation properties, and potential applications of TLYC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron Emission Profile And Neutron Spectrum Measurements At JET: Status And Plans

In large tokamak devices, such as JET, TFTR, JT-60U and ITER, a neutron emission profile monitor is considered as one of the principal diagnostic tools, firstly in providing information to characterize the fusion source in terms of its location, shape, intensity and secondly in developing an understanding of fast ion physics in tokamak plasmas. The JET neutron profile monitor is one of the most advanced such instruments currently operating. It enables 2-D imaging of the non-circular plasma neutron source through a tomographic deconvolution of line-integrated measurements. Historically it was usually assumed that the fusion neutron source is a function of the magnetic flux surfaces (MFS), but recent JET results have clearly demonstrated the influence of non-uniform fast particle populations on the neutron emission profile.Neutron energy spectroscopy also carries valuable information about fast ion behaviour and the fusion and nuclear reactions taking place in the plasma. Spectrum measurements of neutrons will be particularly important for the up-coming JET experiments with a Be wall. The neutron spectroscopy capabilities at JET were recently enhanced by several instruments: a new time-of-flight spectrometer optimized for high count rates (TOFOR), compact neutron spectrometers based on organic scintillator (NE213) and an upgrade of the Magnetic Proton Recoil system (MPRu). In recent JET campaigns, a prototype digital pulse shape discriminator (DPSD) has been successfully tested on one central chord of the JET neutron profile monitor and spectral information has also been obtained. Neutron spectrometry results obtained during the last JET experimental campaigns illustrate the measurement capabilities and indicate their potential use on ITER. Several projects are in progress to further develop such diagnostic capabilities and these are briefly summarized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent Developments in Fast Neutron Detection and Multiplicity Counting with Liquid Scintillator

For many years, LLNL researchers have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of the techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, thermal neutron detectors (mainly {sup 3}He) were used, taking advantage of the high thermal neutron interaction cross sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics that respond over 1000 times faster (ns versus tens of {mu}s) than thermal neutron detectors. Fast neutron detection offers considerable advantages since the inherent ns production timescales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of {sup 3}He-based counters measuring correlated pairs in modest (kg) samples of plutonium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the GERDA Phase II upgrade

The GERDA experiment is designed to search for neutrinoless double beta (0νββ) decay of {sup 76}Ge. In Phase I of the experiment a background index of 10{sup −2} cts/(keV·kg·yr) was reached. A lower limit on the half-life of the 0νββ decay of {sup 76}Ge was set to 2.1·10{sup 25} yr (at 90% C.L.). The aim of Phase II is to reach a sensitivity of the half-life of about 10{sup 26} yr. To increase the exposure thirty new Broad Energy Germanium (BEGe) detectors have been produced. These detectors are distinct for their improved energy resolution and enhanced pulse shape discrimination of signal from background events. Further background reduction will be reached by a light instrumentation to read out argon scintillation light. In April 2015 the light instrumentation together with eight BEGe detectors has been successfully deployed in the GERDA cryostat. In a commissioning run it was shown that two of the major background components, external γ-rays from {sup 214}Bi and {sup 208}Tl decays, were suppressed up to two orders of magnitude. We are confident to reach a background index of 10{sup −3} cts/(keV·kg·yr) which is the design goal for GERDA Phase II.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗