Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system harmonics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

CHANDRA Observations of RX J1914.4+ 2456: Spin-up of a White Dwarf?

RX 51914.4+2456 is a candidate double-degenerate binary with a putative 1.756 mHz orbital frequency. In a previous timing study using archival ROSAT and ASCA data we reported evidence for an increase of the putative orbital frequency at a rate consistent with expectations for gravitational radiation from the system. Here we report the results of new Chandra timing observations which confirm the previous indications of spin-up of the X-ray frequency, and provide much tighter constraints on the frequency derivative, u. We obtained with Chandra a total of 75 ksec of exposure in two epochs separated in time by 10.3 months. The total time span of the archival ROSAT, ASCA and new Chandra data is now 10.2 years. This more than doubles the interval spanned by the ROSAT and ASCA data alone, providing much greater sensitivity to a frequency derivative. With the addition of the Chandra data an increasing frequency is unavoidable, and the mean i/ is 5.9f0.9 x 10-l' Hz s-'. Interestingly, power spectra of the longest Chandra pointing show evidence for a sideband structure to the 1.756 mHz frequency. The fundamental and first harmonic show evidence for upper sidebands with a frequency separation of E 0.5 mHz from their parent peaks. Additionally, the first and second harmonics show evidence for lower sidebands with approximately half the frequency separation of the upper sidebands. Similar sideband structure is a common feature of Intermediate Polars (Ips)-although it is usually observed in the optical-and suggests the presence of a longer period in the system, perhaps the previously unseen orbital period. If this is correct the sideband structure indicates an orbital period close to 1 hr, and the observed u likely represents the accretion-induced spin-up of a white dwarf. We discuss the implications of these findings for the nature of RX J1914.4+2456.

Strohmayer, Tod E.↗

IceCube: Demonstration of an 883 GHz Radiometer for Ice Cloud Remote Sensing

IceCube was a technology demonstration of an 883 GHz heterodyne radiometer on a 3U CubeSat for ice cloud characterization. The project was a collaboration between Goddard Space Flight Center, Virginia Diodes Inc., and Wallops Flight Facility. IceCube was launched to the International Space Station (ISS) in April 2017, and was deployed to the orbit in May 2017. The radiometer measured ice cloud emissions from an ISS orbit for over 15 months. IceCube generated the first 883 GHz cloud map over a large operation temperature range of (5 ºC—37 ºC). Cloud ice plays a major role in the cloud precipitation process and Earth’s energy budget. Ice clouds are used in global circulation models as tuning parameters to achieve model agreement with observation at the top of the atmosphere in the radiation budget and at the bottom for precipitation, however, due to a lack of accurate ice cloud measurements large uncertainties exist in these models. Submillimeter wave remote sensing is capable of addressing this issue by measuring cloud ice mass and microphysical properties in the middle-to-upper troposphere. This fills the sensitivity gap not covered by the visible/infrared and microwave sensors [1]. The goal of IceCube was to increase the TRL of a heterodyne 883 GHz radiometer (using commercial parts) from 5 to 7 by validating the performance in a relevant spaceflight environment. The design of the radiometer was driven by frequency of operation, bandwidth, calibration, available power, and thermal environment requirements. The design included a 15 mm aperture off-axis parabolic reflector with a Potter feed horn, an 883 GHz 2nd-harmonic mixer that is fed by a local oscillator chain with a 24.3 GHz dielectric resonator (MLA), followed by a 6 GHz bandwidth centered at 9 GHz intermediate frequency assembly (IFA), receiver interface card, and power distribution unit. The IFA included an internal noise diode calibration to separate the MLA performance from the rest of the system. For this the radiometer had four operational states: antenna, antenna + noise, reference, and reference + noise; each state’s duration was 10 ms. The total power dissipation of the instrument was 5.6 W. The spacecraft had spinning capabilities to provide a cold sky view for calibration. We present the instrument design, ground test results, challenges, and highlight some of the flight measurements.

N Ehsan↗

Comparison of Power System Current Sensors via Playback of Electrical Disturbances

The need to accurately measure high-frequency content in power system voltage and current phenomena is increasingly becoming more of a priority. As the amount of distributed energy resources (DER) and nonlinear loads penetrating the grid increases, so do challenges associated with traditional measurement and metering applications. In this paper, three commercially-available medium-voltage-level current sensors are characterized in terms of their harmonic amplitude and phase performance against reference signals that are “played back” through the sensors through the use of an arbitrary waveform generator. It is shown that none of the three sensors studied are able to faithfully replicate all of the input signals completely, though there are advantages and disadvantages to each in terms of noise, resonance, and induced phase drift. Additionally, the Goodness-of-Fit metric, typically used for PMU model validation, is used to generate side-by-side comparisons of sensor accuracy over a small window around the events under study.

Wilson, Aaron↗

Application of higher harmonic blade feathering for helicopter vibration reduction

Higher harmonic blade feathering for helicopter vibration reduction is considered. Recent wind tunnel tests confirmed the effectiveness of higher harmonic control in reducing articulated rotor vibratory hub loads. Several predictive analyses developed in support of the NASA program were shown to be capable of calculating single harmonic control inputs required to minimize a single 4P hub response. In addition, a multiple-input, multiple-output harmonic control predictive analysis was developed. All techniques developed thus far obtain a solution by extracting empirical transfer functions from sampled data. Algorithm data sampling and processing requirements are minimal to encourage adaptive control system application of such techniques in a flight environment.

Powers, R. W.↗

Preliminary results on noncollocated torque control of space robot actuators

In the Space Station era, more operations will be performed robotically in space in the areas of servicing, assembly, and experiment tending among others. These robots may have various sets of requirements for accuracy, speed, and force generation, but there will be design constraints such as size, mass, and power dissipation limits. For actuation, a leading motor candidate is a dc brushless type, and there are numerous potential drive trains each with its own advantages and disadvantages. This experiment uses a harmonic drive and addresses some inherent limitations, namely its backdriveability and low frequency structural resonances. These effects are controlled and diminished by instrumenting the actuator system with a torque transducer on the output shaft. This noncollocated loop is closed to ensure that the commanded torque is accurately delivered to the manipulator link. The actuator system is modelled and its essential parameters identified. The nonlinear model for simulations will include inertias, gearing, stiction, flexibility, and the effects of output load variations. A linear model is extracted and used for designing the noncollocated torque and position feedback loops. These loops are simulated with the structural frequency encountered in the testbed system. Simulation results are given for various commands in position. The use of torque feedback is demonstrated to yield superior performance in settling time and positioning accuracy. An experimental setup being finished consists of a bench mounted motor and harmonic drive actuator system. A torque transducer and two position encoders, each with sufficient resolution and bandwidth, will provide sensory information. Parameters of the physical system are being identified and matched to analytical predictions. Initial feedback control laws will be incorporated in the bench test equipment and various experiments run to validate the designs. The status of these experiments is given.

Tilley, Scott W.↗

Investigation of a Helicopter Individual Blade Control (IBC) System in Two Full-Scale Wind Tunnel Tests: Volume I

This report presents the data acquired during the testing of an individual blade control (IBC) system on a full-scale helicopter rotor in two test entries in the NASA Ames 40- by 80-Foot Wind Tunnel. The objective of these investigations was to evaluate the potential benefits of using IBC to improve rotor performance, reduce blade vortex interaction (BVI) noise, and alleviate helicopter vibrations. The wind tunnel tests were an international, collaborative effort between NASA, the U.S. Army Aeroflightdynamics Directorate, ZF Luftfahrttechnik GmbH, Eurocopter Deutschland GmbH, and the German Aerospace Laboratory (DLR). They were conducted as a task of the U.S./German Memorandum of Understanding (MOU) on Helicopter Aeromechanics. The IBC tests were performed using a full-scale BO-105 helicopter rotor mounted to the NASA/U.S. Army Rotor Test Apparatus (RTA). The first test, performed in 1993, was the first full-scale wind tunnel test to explore the effects of an IBC system on rotor vibration, noise, and performance. In this test, the pitch links of the rotor were replaced by servo-actuators. The servo-actuators and IBC control system were designed and manufactured by ZF Luftfahrttechnik GmbH. This control system allowed the pitch of each rotor blade to be changed independently of the other blades. The IBC inputs had large effects on the hub vibrations and BVI noise. However, the rotor hub moments were not retrimmed with each new IBC input. This resulted in an out-of-trim rotor configuration. The same IBC system was used in the second IBC test performed in 1994. This test more carefully investigated the potential of IBC to simultaneously reduce noise and vibration and also investigated the effect of IBC on rotor performance in high-speed-cruise flight. In the 1994 test, the hub moment and rotor thrust were readjusted to maintain rotor trim as the IBC inputs were applied. For this reason, the data taken from the second test are considered to be more accurate, except for some unique IBC input combinations not repeated in the second test. IBC controls that were evaluated were single-frequency inputs from 2/rev to 6/rev and multi-harmonic combinations of these frequencies to form pulses, wavelets, and doublets. Extensive data were acquired for each IBC data point. These data included rotor performance, average and time-varying hub loads, rotor blade bending loads, control system loads, inboard and outboard blade pitch motions, and BVI noise data. The rotor balance hub force and moment data included the mean values, half-peak-to-peak values, and sine/cosine harmonics up to the 20th rotor harmonic. The time history and averaged Fourier spectrum for each measurement are available electronically from NASA Ames Research Center. The data indicate that significant reduction in both BVI noise and hub vibration can be obtained using IBC. The 2/rev input produced the best single-frequency results. At a typical descent flight condition, 2/rev IBC combined with other IBC harmonics reduced the BVI noise up to 12 dB (85 percent) at some microphone locations. At the same time, this input could also reduce the dominant 4/rev vibratory hub loads by up to 75 percent. The data also show that performance improvements of up to 7 percent were obtained using 2/rev IBC at high-speed forward flight conditions. An analysis of the hydraulic power requirements for BVI noise suppression, vibration reduction, and rotor performance improvement is included in this report. This analysis shows that the power required by the IBC system is negligible at low-speed flight conditions, and that a net gain of 3 percent of rotor horsepower can be achieved at high-speed flight conditions.

Investigation↗

A theoretical study of the application of jet flap circulation control for reduction of rotor vibratory forces

The results of a study to investigate the theoretical potential of a jet-flap control system for reducing the vertical and horizontal non-cancelling helicopter rotor blade root shears are presented. A computer simulation describing the jet-flap control rotor system was developed to examine the reduction of each harmonic of the transmitted shears as a function of various rotor and jet parameters, rotor operating conditions and rotor configurations. The computer simulation of the air-loads included the influences of nonuniform inflow and blade elastic motions. (no hub motions were allowed.) The rotor trim and total rotor power (including jet compressor power) were also determined. It was found that all harmonics of the transmitted horizontal and vertical shears could be suppressed simultaneously using a single jet control.

Piziali, R. A.↗

The 1984 solar oscillation program of the Mount Wilson 60-foot tower

The instrumentation, data, and preliminary results from the summer, 1984, solar oscillation observing program which was carried out using the 60-foot tower telescope of the Mt. Wilson Observatory are described. This program was carried out with a dedicated solar oscillation observing system and obtained full-disk Dopplergrams every 40 seconds for up to 11 hours per day. Between June and September, 1984, observations were obtained with a Na magneto-optical filter on 90 different days. The data analysis has progressed to the point that spherical harmonic filter functions were employed to generate a few one-dimensional power spectra from a single day's observations.

Rhodes, E. J., Jr.↗

The 1984 solar oscillation program of the Mt. Wilson 60-foot tower

The instrumentation, data, and preliminary results from the summer, 1984, solar oscillation observing program which was carried out using the 60-foot tower telescope of the Mt. Wilson Observatory are described. This program was carried out with a dedicated solar oscillation observing system and obtained full-disk Dopplergrams every 40 seconds for up to 11 hours per day. Between June and September, 1984, observations were obtained with a Na magneto-optical filter on 90 different days. The data analysis has progressed to the point that spherical harmonic filter functions were employed to generate a few one-dimensional power spectra from a single day's observations.

Rhodes, Edward J., Jr.↗

WRATS Integrated Data Acquisition System

The Wing and Rotor Aeroelastic Test System (WRATS) data acquisition system (DAS) is a 64-channel data acquisition display and analysis system specifically designed for use with the WRATS 1/5-scale V-22 tiltrotor model of the Bell Osprey. It is the primary data acquisition system for experimental aeroelastic testing of the WRATS model for the purpose of characterizing the aeromechanical and aeroelastic stability of prototype tiltrotor configurations. The WRATS DAS was also used during aeroelastic testing of Bell Helicopter Textron s Quad-Tiltrotor (QTR) design concept, a test which received international attention. The LabVIEW-based design is portable and capable of powering and conditioning over 64 channels of dynamic data at sampling rates up to 1,000 Hz. The system includes a 60-second circular data archive, an integrated model swashplate excitation system, a moving block damping application for calculation of whirl flutter mode subcritical damping, a loads and safety monitor, a pilot-control console display, data analysis capabilities, and instrumentation calibration functions. Three networked computers running custom-designed LabVIEW software acquire data through National Instruments data acquisition hardware. The aeroelastic model (see figure) was tested with the DAS at two facilities at NASA Langley, the Transonic Dynamics Tunnel (TDT) and the Rotorcraft Hover Test Facility (RHTF). Because of the need for seamless transition between testing at these facilities, DAS is portable. The software is capable of harmonic analysis of periodic time history data, Fast Fourier Transform calculations, power spectral density calculations, and on-line calibration of test instrumentation. DAS has a circular buffer archive to ensure critical data is not lost in event of model failure/incident, as well as a sample-and-hold capability for phase-correct time history data.

Piatak, David J.↗

A Distributed Control Architecture for Cascaded H-Bridge Converter with Integrated Battery Energy Storage

Cascaded H-bridge topology has been used in grid-tied converters for battery energy storage system due to its modular structure. To fully utilize the converter’s modularity, this paper proposes a hierarchical distributed control architecture that consists of primary control, secondary control and battery state of charge (SOC) balancing control. Primary control ensures accurate current tracking while a distributed secondary control based on consensus algorithm is presented to regulate power sharing among modules and is proved to be stable theoretically. Here, a distributed SOC balancing control is further introduced to improve energy efficiency of battery energy storage system. Finally, the hierarchical distributed control strategy is implemented using hardware controllers and a software platform. Besides, a carrier phase shift control is also implemented to achieve multilevel output voltage and harmonic reduction. The experimental results demonstrate the performance of the proposed control scheme effectively.

25 ENERGY STORAGE↗

Goldstone radar observations of Mars: The 1986 opposition

Radar echoes from the planet Mars were obtained on 27 S-band (wavelength = 12.5 cm) and 2 X-band (wavelength = 3.5 cm) tracks using the Goldstone Solar System Radar. These observations took advantage of the favorable 1986 opposition since the Earth-Mars distance was 0.40 AU at opposition and radar echo strength is proportional to inverse-fourth-power of the distance to the target. The coverages of the Goldstone observations are summarized. The observations were conducted via the CW-spectra techniques described by Harmon et al. A continuous tone was transmitted at Mars and the radar echo was sampled to obtain a Doppler spread spectrum. Each received event was separated into polarized (opposite sense circular) and depolarized (same sense circular) periods. There was one successful ranging run which had a resolution of 2 microseconds. This should yield surface heights accurate to 300 meters.

Thompson, T. W.↗

Modeling the Functional Forms of Grid Disturbances

This report introduces a functional form that may be used to quantitatively predict the impacts of new grid tools and changing system qualities on the likelihoods, durations, and depths of various grid disturbances. Each disturbance scenario is modeled to have three component stages—avoidance, reactance and recovery, which together parametrically estimate one disturbance’s impacts. The modeled scenario is then placed and replicated within an analysis period to represent the likelihood or frequency of the scenario and its consequent impacts. Whereas analysts have struggled to define and apply metrics for grid resilience, the functional form introduced by this report shares units of measurement with accepted grid-status measures (e.g., numbers of customers currently experiencing a service outage). Furthermore, the integrated and averaged functional form over an analysis period provides a meaningful normalized performance metric (e.g., customer outage minutes per year) that is ultimately independent of the duration of the period of. The approach may be applied similarly regardless of the severity or frequency of the disturbances that are being analyzed. Because metrics can be chosen to be identical in both the hypothetical future and the actual historical past, the historical past eventually becomes the test of the future predictions, at least in a statistical sense. The authors originally developed this approach to facilitate analysis of the effects of transactive energy (TE) systems effects on electric power grid resilience. TE systems invite energy suppliers and consumers to actively collaborate toward the discovery of, and their responses to, the locational value of energy. The findings from this process are often embodied as energy prices, the dynamics of which indicate the locational value of energy and can further represent important grid service needs. While some academic papers claim to quantify the value of a specific TE system design toward grid resilience, the answer, in general, has been elusive. Not only do multiple and conflicting definitions of resilience and reliability exist, but countless TE systems are being invented. We conclude the following: (1) The ideal analysis should harmonize rather than differentiate resilience and reliability. Therefore, this report uses the more general term disturbance whenever the overloaded terms resilience and reliability can be avoided. (2) The effectiveness of TE systems must be mapped to underlying qualities of a TE system, thereby avoiding presumptions that every TE design offers similar advantages. The authors seek to evaluate the parametric effects of TE system qualities (e.g., spatial granularity, granularity of time steps, length of future prediction horizon) on avoiding, reacting to, and recovering from grid disturbances. Furthermore, any advantages (or disadvantages) must be fairly compared with the many alternative tools, systems, and strategies that might offer comparable benefits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sequence Impedance Modeling of Grid-Forming Inverters

Grid-forming control of inverter-based resources has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents the sequence impedance modeling of a grid-forming inverter to evaluate its small-signal stability properties. Droop control structure is implemented to control the inverter in grid-forming mode, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.

grid- following inverter↗

Sequence Impedance Modeling of Grid-Forming Inverters

Grid-forming control of inverter-based resources has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents the sequence impedance modeling of a grid-forming inverter to evaluate its small-signal stability properties. Droop control structure is implemented to control the inverter in grid-forming mode, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.

grid-following inverter↗

Sequence Impedance Modeling of Grid-Forming Converters: Preprint

Grid-forming control of inverter-based resources (IBRs) has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents sequence impedance modeling of grid-forming inverters to evaluate its small-signal stability properties. Droop based grid-forming control with full consideration of the multiloop structure is studied, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Quantum mechanical out-of-time-ordered-correlators for the anharmonic (quartic) oscillator

Out-of-time-ordered correlators (OTOCs) have been suggested as a means to study quantum chaotic behavior in various systems. In this work, I calculate OTOCs for the quantum mechanical anharmonic oscillator with quartic potential, which is classically integrable and has a Poisson-like energy-level distribution. For low temperature, OTOCs are periodic in time, similar to results for the harmonic oscillator and the particle in a box. For high temperature, OTOCs exhibit a rapid (but power-like) rise at early times, followed by saturation consistent with 2 < x 2 >T < p 2 > T at late times. At high temperature, the spectral form factor decreases at early times, bounces back and then reaches a plateau with strong fluctuations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stabilized Acoustic Levitation of Dense Materials Using a High-Powered Siren

Stabilized acoustic levitation and manipulation of dense (e.g., steel) objects of 1 cm diameter, using a high powered siren, was demonstrated in trials that investigated the harmonic content and spatial distribution of the acoustic field, as well as the effect of sample position and reflector geometries on the acoustic field. Although further optimization is possible, the most stable operation achieved is expected to be adequate for most containerless processing applications. Best stability was obtained with an open reflector system, using a flat lower reflector and a slightly concave upper one. Operation slightly below resonance enhances stability as this minimizes the second harmonic, which is suspected of being a particularly destabilizing influence.

Gammell, P. M.↗