Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “point source sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

On-line calibration of high-response pressure transducers during jet-engine testing

Current jet engine testing is concerned with the effect of inlet pressure and temperature distortions on engine performance and involves the use of numerous miniature pressure transducers. Despite recent improvements in the manufacture of miniature pressure transducers, they still exhibit sensitivity change and zero shift with temperature and time. To obtain meaningful data, a calibration system is needed to determine these changes. A system has been developed which provides for computer selection of appropriate reference pressures selected from nine different sources to provide a two- or three-point calibration. Calibrations are made on command, before and sometimes after each data point. A unique 'no leak' matrix valve design is used in the reference-pressure system. Zero-shift corrections are measured and the values are automatically inserted into the data reduction program.

Armentrout, E. C.↗

Infrared Astronomical Satellite /IRAS/ Scientific Data Analysis System

The Infrared Astronomical Satellite (IRAS), to be launched in 1982, is discussed. It will systematically survey the entire sky over a large percentage of the infrared spectrum, in the wavelength region of 8 to 120 microns, at sensitivities a hundred times greater than previously achieved from high-altitude observatories, aircraft, balloons or sounding rockets. The Scientific Data Analysis System (SDAS), an off-line data processing facility, is examined. Its primary function is to produce a catalog of inertially fixed infrared-emitting point sources (mainly stars and galaxies) observed during the IRAS survey. Details for source detection and confirmation are given. It is estimated that the catalog will contain approximately a million objects having a brightness of 10 amtowatts per square centimeter or greater; 125,000 SDAS detections, if spurious events of signal-to-noise ratios greater than 2.5 are included, will be made every day.

Duxbury, J. H.↗

Cryogenic telescope on the Infrared Astronomical Satellite (IRAS)

The Infrared Astronomical Satellite (IRAS) has completed an unbiased all-sky survey at wavelengths from 10 to 100 microns. The design and performance of the focal plane array is described with emphasis on in-orbit measurements of the sensitivity and stability. In the four broad spectral bands centered at 12, 25, 60, and 100 microns, the system noise equivalent flux density (NEFD) values are in Jy/(Square root of Hz), 0.03, 0.025, 0.046, and 0.21, respectively (Jansky = 10 to the -26th W/sq m/Hz). For point sources, a single scan at the survey rate of 3.8 arcmin/s yields limiting flux densities at the 3-sigma confidence level of 0.36, 0.30, 0.39, and 1.2 Jy. The dc stability of the junction field effect transistor (JFET) amplifiers and the excellent off-axis rejection of the telescope permit total flux measurements of extended infrared emission at levels below 6,000,000 Jy/sr. Response of the extrinsic silicon and germanium photo-detectors to ionizing radiation is described.

Low, F. J.↗

An experimental assessment of the imaging quality of the low energy gamma-ray telescope ZEBRA

One gamma-ray detection plane of the ZEBRA telescope, consisting of nine position sensitive scintillation crystal bars designed to operate over the spectral range 0.2 to 10 MeV, has been constructed in the laboratory. A series of experimental images has been generated using a scaled down flight pattern mask in conjunction with a diverging gamma-ray beam. Point and extended sources have been imaged in order to assess quantitatively the performance of the system.

Butler, R. C.↗

Solar flare gamma-ray and hard x ray imaging with the GRID-on-a-balloon

A primary scientific objective for solar flare research during the rapidly approaching maximum in solar activity is the imaging of gamma-ray and hard x ray sources of solar flare emissions. These goals will be pursued by the Gamma Ray Imaging Device (GRID) instrument, one of three instruments recently selected for NASA's Max '91 Solar Balloon Program. The GRID instrument is based on the technique of Fourier transform imaging and utilizes scanning modulation grid collimator optics to provide full-Sun imaging with 1.9-arcsecond resolution over the energy range from 20 to 700 keV at time resolutions from 0.1 to 2 s. The GRID telescope will employ 32 subcollimators, each composed of a matched pair of high-Z collimator grids separated by 5.2 meters and a phoswich scintillation spectrometer detector having no spatial resolution. The subcollimators and integrally-mounted fine aspect system are contained within a telescope canister which will be pointed to 0.1 degree accuracy and cyclically scanned to produce source modulation. The 32 subcollimators provide a uniform distribution of grid slit orientations and a logarithmic distribution of slit spacings corresponding to angular dimensions of 1.9 arcseconds to several arcminutes. The instrument is several orders of magnitude more sensitive than the HXIS instrument on the Solar Maximum Mission (SMM) and nearly 10 times more sensitive than any similar instrument scheduled to fly during the next solar maximum. The payload, designed for long-duration high-altitude balloon capability, is scheduled for its first science flight (8 to 14 days duration) from the Antarctic in January of 1992.

Orwig, Larry E.↗

Small-scale fluctuations of the X-ray background

Fluctuations of the diffuse X-ray background are investigated using the Einstein Observatory Deep Survey data. Small angular-scale variations of the numbers of counts in the energy range 0.8-3.5 keV in the central 32 x 32 sq arcmin of the IPC are analyzed by means of the two-point correlation function. It is shown that detector modulation contributes substantially to the observed fluctuations. Instrumental effects are estimated and subtracted from the raw observations. The residual fluctuations are used to estimate the log N-log S relation of the X-ray sources below the Einstein sensitivity limit. Taking into account numerous uncertainties involved in this analysis, it is shown that the amplitude of fluctuations observed in the Deep Survey data is consistent with a relatively small number of sources producing the X-ray background.

Soltan, A. M.↗

Chemical compositions of primitive solar system particles

Chemical studies of micrometeorites are of fundamental importance primarily because atmospheric entry selection effects (such as destruction of friable objects) are less significant than those for conventional meteorites. As a result, particles that have experienced very little postaccretional processing have a significant chance of surviving the Earth encounter and subsequent collection. Thus, chemical analyses of these relatively unaltered micrometeorites may lead to a better understanding of the compositions of the most primitive materials in the solar system and thereby constrain the conditions (physical and chemical) that existed in the early solar nebula. Micrometeorites have been collected from the stratosphere, polar ices, and ocean sediments, but the stratospheric collection is the best source for the most unaltered material because they are small and are not heated to their melting points. Despite the fact that the stratospheric micrometeorites have masses in the nanogram range, a variety of microanalytical techniques have been applied to bulk chemical analyses with part-per-million sensitivity. In some cases, multi-disciplinary studies (e.g., chemistry and mineralogy) have been performed on individual particles. The first-order conclusion is that the chondrite-like particles are chemically similar to carbonaceous chondrites but in detail are distinct from members of the conventional meteorite collection. The purpose of this paper is to provide an overview of the results to date and identify important areas for further study.

Sutton, Steve R.↗

Gamma Ray Source Localization for Time Projection Chamber Telescopes Using Convolutional Neural Networks

Diverse phenomena such as positron annihilation in the Milky Way, merging binary neutron stars, and dark matter can be better understood by studying their gamma ray emission. Despite their importance, MeV gamma rays have been poorly explored at sensitivities that would allow for deeper insight into the nature of the gamma emitting objects. In response, a liquid argon time projection chamber (TPC) gamma ray instrument concept called GammaTPC has been proposed and promises exploration of the entire sky with a large field of view, large effective area, and high polarization sensitivity. Optimizing the pointing capability of this instrument is crucial and can be accomplished by leveraging convolutional neural networks to reconstruct electron recoil paths from Compton scattering events within the detector. In this investigation, we develop a machine learning model architecture to accommodate a large data set of high fidelity simulated electron tracks and reconstruct paths. We create two model architectures: one to predict the electron recoil track origin and one for the initial scattering direction. We find that these models predict the true origin and direction with extremely high accuracy, thereby optimizing the observatory’s estimates of the sky location of gamma ray sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On-line calibration of high-response pressure transducers during jet-engine testing

Jet engine testing is reported concerned with the effect of inlet pressure and temperature distortions on engine performance and involves the use of numerous miniature pressure transducers. Despite recent improvements in the manufacture of miniature pressure transducers, they still exhibit sensitivity change and zero-shift with temperature and time. To obtain meaningful data, a calibration system is needed to determine these changes. A system has been developed which provides for computer selection of appropriate reference pressures selected from nine different sources to provide a two- or three-point calibration. Calibrations are made on command, before and sometimes after each data point. A unique no leak matrix valve design is used in the reference pressure system. Zero-shift corrections are measured and the values are automatically inserted into the data reduction program.

Armentrout, E. C.↗

XL-Calibur - a second-generation balloon-borne hard X-ray polarimetry mission

XL-Calibur is a hard X-ray (15-80 keV) polarimetry mission operating from a stabilised balloon-borne platform in the stratosphere. It builds on heritage from the X-Calibur mission, which observed the accreting neutron star GX 301−2 from Antarctica, between December 29th 2018 and January 1st 2019. The XL-Calibur design incorporates an X-ray mirror, which focusses X-rays onto a polarimeter comprising a beryllium rod surrounded by Cadmium Zinc Telluride (CZT) detectors. The polarimeter is housed in an anticoincidence shield to mitigate background from particles present in the stratosphere. The mirror and polarimeter-shield assembly are mounted at opposite ends of a12 m long lightweight truss, which is pointed with arcsecond precision by WASP – the Wallops Arc Second Pointer. TheXL-Calibur mission will achieve a substantially improved sensitivity over X-Caliburby using a larger effective area X-ray mirror, reducing background through thinner CZT detectors, and improved anticoincidence shielding. When observing a 1 Crab source for t(day) days, the Minimum Detectable Polarisation (at 99% confidence level) is∼2%·t−1/2day. The energy resolution at 40 keV is∼5.9 keV. The aim of this paper is to describe the design and performance of the XL-Calibur mission, as well as the foreseen science programme.

Q Abarr↗

Assessing the Altimetric Measurement from CYGNSS Data

The Cyclone Global Navigation Satellite System (CYGNSS) mission was designed to study hurricane intensification by measuring wind speeds in tropical cyclones. However, the delay-Doppler maps (DDM) that are produced can be used to estimate the sea surface height (SSH) at the specular reflection point on the ocean surface. Proofof-concept studies that DDMs are suitable to solve for SSH have been recently reported (Clarizia et al., 2016; Mashburn et al., 2018), based on data acquired by the demonstration satellite experiment Tech Demo Sat - 1 (TDS-1) carrying a GNSS-R receiver similar to the ones onboard CYGNSS. Although the precision of each 1sec averaged SSH is considerably lower than that of the existing satellite altimeters, by virtue of the dense coverage and frequent revisit time exhibited by the constellation of 8 microsats, the error may be smoothed down considerably by optimal interpolation (Li et al., 2016). Hence the CYGNSS dataset presents a potential opportunity to sample the tropical oceans, and investigate the sensitivity of the SSH measurements to mesoscale eddies. Our objective is to analyze the CYGNSS data and test a suite of retrieval algorithms, including that of Mashburn et al., 2018 to obtain SSH, to understand the error sources and possible corrections when available. Because of the limited antenna gain of the CYGNSS instrument, the power SNR for general wind conditions is expected to be too low to accurately track the reflection point contribution, resulting in altimetry errors of the order of several meters. Other significant error sources are the CYGNSS satellites orbit knowledge, the ionosphere, the troposphere, the mean sea surface and the tides; some of these errors can be reduced by using models. The corrected SSH data will be assimilated into the ROMS high-resolution ocean model to investigate their ability to reproduce mesoscale eddies in the tropical oceans.

Voronovich, Alexander↗

An Investigation into the Surface Skidding Response of PBX 9501 and PBX 9502

While polymer-bonded explosives, PBX, have reduced sensitivity to ignition from mechanical shock or heating compared to conventional explosives, the investigation of the mechanical ignition mechanisms for PBX remains vital to assessing the safety during machining and general handling. Under frictional heating, hot spot generation due to high melting point contaminants in the interface is a suspected source for increased probability of detonation. Here, to investigate such frictional heating, samples of PBX 9501 and PBX 9502 were impacted and skidded against a tangentially moving target and thermally imaged. Temporally resolved temperature and forces were simultaneously measured with and without 300 µm silica grit at the frictional interface. A trend of increasing temperature was observed as the speed and tangential force on the sample increased. Grit particles in the frictional interface were found to act as frictional heat concentration spots owing to the grit's protrusion from the surface and lesser susceptibility to melting compared to the PBX. The coefficient of friction between PBX 9501 and the skidding surface was observed to be largely constant for forces and speeds at the lower end of the test range. In contrast, at high tangential speeds, the coefficient was found to be significantly lower.

36 MATERIALS SCIENCE↗

Search for magnetically-induced signatures in the arrival directions of ultra-high-energy cosmic rays measured at the Pierre Auger Observatory

We search for signals of magnetically-induced effects in the arrival directions of ultra-high-energy cosmic rays detected at the Pierre Auger Observatory. We apply two different methods. One is a search for sets of events that show a correlation between their arrival direction and the inverse of their energy, which would be expected if they come from the same point-like source, they have the same electric charge and their deflection is relatively small and coherent. We refer to these sets of events as “multiplets”. The second method, called “thrust”, is a principal axis analysis aimed to detect the elongated patterns in a region of interest. We study the sensitivity of both methods using a benchmark simulation and we apply them to data in two different searches. The first search is done assuming as source candidates a list of nearby active galactic nuclei and starburst galaxies. The second is an all-sky blind search. We report the results and we find no statistically significant features. We discuss the compatibility of these results with the indications on the mass composition inferred from data of the Pierre Auger Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

Mapping of a Novel Zero-Liquid Discharge Desalination System Based on Humidification–Dehumidification onto the Field of Existing Desalination Technologies

It is well-established that increasing demands for fresh water are paving the way for desalination technologies. However, this correlates with an increase in brine production whose treatment and disposal can be complicated and expensive. This paper presents a thermodynamic model to bound the operation and development of a novel Humidification–Dehumidification-based system featuring Zero-Liquid Discharge and off-grid capabilities. The model employs conservation laws to find feasible state points to meet a baseline operation of 10 kg/h of product water separated from a hypersaline feed stream with 100 g/kg salt concentration. The system incurs in a 1039 kWh/m3 energy intensity that can be supplied completely by an electric source or in combination with heating steam. Follow-up sensitivity analysis highlights the robustness of the system in handling variations of 25% in product flowrate and 75% in feed salinity, practically without incurring any additional energy demands. The proposed system operating costs between 72 USD/m3 and 96 USD/m3 are comparable to those of existing brine disposal techniques. Furthermore, an operational map of existing desalination technologies suggests a niche characterized by high recovery rates and high feed salinities that are generally unfulfilled by conventional desalination methods. Overall, the proposed system shows potential for off-grid hypersaline brine treatment. This study sets the stage for future development of physics-based and data-driven predictive models as the proposed system iterates into a pilot plant deployment.

54 ENVIRONMENTAL SCIENCES↗

Impedance measurement using a two-microphone, random-excitation method

The feasibility of using a two-microphone, random-excitation technique for the measurement of acoustic impedance was studied. Equations were developed, including the effect of mean flow, which show that acoustic impedance is related to the pressure ratio and phase difference between two points in a duct carrying plane waves only. The impedances of a honeycomb ceramic specimen and a Helmholtz resonator were measured and compared with impedances obtained using the conventional standing-wave method. Agreement between the two methods was generally good. A sensitivity analysis was performed to pinpoint possible error sources and recommendations were made for future study. The two-microphone approach evaluated in this study appears to have some advantages over other impedance measuring techniques.

Seybert, A. F.↗

The AIRES Optical Design

AIRES (Airborne InfraRed Echelle Spectrometer) is the facility spectrometer for SOFIA (Stratospheric Observatory For Infrared Astronomy). AIRES is a long-slit (approximately 160 in) spectrometer designed to cover the 17 to 210-micron range with good sensitivity using three spectroscopic arrays. Initially, only the 30-130 micron, mid-wavelength array will be available. The instrument has a cryogenic K-mirror to perform field rotation and a slit-viewing camera (lambda < 28 microns, FOV = 160 in diameter) to image source morphology and verify telescope pointing. AIRES employs a large echelle grating to achieve a spectral resolving power (lambda/delta lambda) of approximately 1.0 x 10(exp 6)/lambda (sub mu), where lambda (sub mu) is the wavelength in microns. Hyperfine, Inc. has ruled and tested the AIRES' echelle; its wave-front error is 0.028 waves RMS (root mean square) at 10.6 microns. The instrument is housed in a liquid-helium cryostat which is constrained in diameter (approximately 1 m) and length (approximately 2 m) by the observatory. Hence, the length of the echelle (approximately 1.1 m) and the focal length of its collimator (approximately 5.2 m) severely drive the optical design and packaging. The final design uses diamond-turned aluminum optics and has up to 19 reflections inside the cryostat, depending on the optical path. This design was generated, optimized, and toleranced using Code V. The predicted performance is nearly diffraction-limited at 17 microns; the error budget is dominated by design residuals. Light loss due to slit rotation and slit curvature has been minimized. A thorough diffraction analysis with GLAD (G-Level Analysis Drawer) was used to size the mirrors and baffles; the internal light loss is shown to be a strong function of slit width.

Haas, Michael R.↗

Evaluation of Minimum Detectable Activities for Stack Sample Analyses

The Rad-NESHAP program takes samples at major point sources to track how much of select nuclides are being emitted out of the stack. Samples are taken at the site where the radiological operations are being performed. The samples are then sent to analytical laboratories for analysis to determine what nuclides exist in the sample. However, due to the sensitivity of the instruments, false positives are often reported. To reduce the number of false positives, the results reported from the analytical labs are compared to set detection limits. Anything below the set detection limit is considered part of the background while anything above the limit is considered a positive hit. Therefore, the detection limit must be set low enough that any false negatives do not result in a significant dose missed at the end of the year but high enough that there are not enough false positives to skew the annual dose being reported. All detection limits listed in this section for the analyses below were designed to meet the stated equivalent emissions rate and subsequent off-site doses. These minimum detectable activities (MDAs) were developed in the 1990s and documented in the memo cited for each analysis below. These limits and memos are all currently referenced in the Quality Assurance Project Plan (QAPP) for the Rad-NESHAP Compliance Task, which is being updated to a Project Implementation Plan (PIP) concurrently with this document. As part of this update process, the original MDAs defined in this section needed to be verified that they were still conservative and meet the off-site dose levels stated.

2019 MDA↗

Comments on measuring the overall and the depressed collector efficiency in TWT's and klystron amplifiers

Kosmahl and Ramins (1977), who reported results achieved with broadband, high-performance TWT's, augmented with multistage depressed collectors for higher overall efficiency, have pointed out the necessity for accurately measuring and correctly defining the various power terms involved. In view of the now wide-spread use of depressed collectors and reported results, the definitions of tube and collector efficiency are restated and comments are provided on the sensitivity of these terms to various sources of experimental and definitional errors in order to permit a uniform evaluation of collector performance.

Kosmahl, H. G.↗