Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “picosecond”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Patterned anodes with sub-millimeter spatial resolution for large-area MCP-based photodetector systems

Micro-channel-plate-based photo-detectors are unique in being capable of covering very large areas such as those required in elementary particle and nuclear physics, while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, and time resolutions of 30 psec–50 psec for single photons. In such systems the electronic channel count is a major cost driver. Incorporating a capacitively-coupled anode allows the use of external pickup electrodes with patterns of individual channels optimized for occupancy, rate, and time/space resolution. The signal pickup antenna can be economically implemented as a printed circuit card with a 2-dimensional array of pads for high-occupancy/high-rate applications such as in particle colliders and medical imaging, or a 1-dimensional array of strips for a lower channel count in low-occupancy/low-rate applications such as large neutrino detectors. In this paper we present pad patterns that enhance signal-sharing between pads to lower the channel count per unit area in large-area systems by factors up to 4, while maintaining spatial resolutions of approximately 100 to 200 μ m for charged particles and 400 to 1000 μ m for single photons. Patterns that use multiple signal layers in the signal-pickup board can lower the channel count even further, moving the scaling behavior in the number of pads versus total area from quadratic to linear.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Field-Enhanced Conduction-Cooled Superconducting Cavity for High-Repetition-Rate Ultrafast Electron Bunch Generation

High-repetition-rate sources of bright electron bunches have a wide range of applications. They can directly be employed as probes in electron-scattering setups, or serve as a backbone for the generation of radiation over a broad range of the electromagnetic spectrum. This paper describes the development of a compact sub-Mega-electronvolt (sub-MeV) electron-source setup capable of operating at MHz repetition rates and forming sub-picosecond electron bunches with transverse emittance below 20 nm. The setup relies on a conduction-cooled superconducting single-cell resonator with its geometry altered to enhance the field at the surface of the emitter. The system is designed to accommodate cooling using a 2 W pulse-tube cryogen-free cryocooler operated at 4.2 K. Although we focus on the case of a photoemitted electron bunch, the scheme could be adapted to other emission mechanisms.

43 PARTICLE ACCELERATORS↗

Gamma-ray spectroscopy using angular distribution of Compton scattering

We present a novel method to perform gamma-ray spectroscopy suitable for extreme pileup situations, wherein traditional pulse-height spectroscopy is infeasible or impractical. One example of such application is spectral characterization of intense laser-based radiation sources that employ laser wakefield acceleration, in which a large number of photons can be produced in a well-collimated beam on a picosecond or shorter timescale. The method relies on the angularly-resolved calorimetric measurement of Compton scattering. The probability for a photon to undergo Compton scattering into a given solid angle is a function of its energy and is described by the Klein–Nishina formula. By first Compton scattering the incident beam and then measuring the total energies deposited in multiple detectors placed at various scattering angles, the incident beam energy spectrum can be reconstructed without resolving the individual events in detectors. Here, we compare the performance of an maximum likelihood expectation maximization algorithm with that of an artificial neural network to measure the energy spectrum of a beam of monoenergetic gamma rays from 137Cs decay. We demonstrate that the method can be used to reconstruct the characteristic inverse Compton scattering spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffused trenches for high fill-factor Low-Gain Avalanche Diodes

Low-Gain Avalanche Diodes (LGADs) are a class of silicon detectors that have been specifically designed for the fast detection of minimum ionizing particles (mips) in High-Energy Physics experiments. While they provide timing resolution on the order of a few tens of picoseconds, they cannot achieve high spatial resolution due to the intrinsic characteristics of their structures. Thus, active R&D is on-going to develop detectors based on LGADs to improve their spatial resolution while maintaining the timing performance of the LGADs. Such devices are, for example, AC-coupled LGADs and Deep-Junction LGADs. Another device option is the Trench-Isolated LGAD (TI LGAD), where trenches etched at the periphery of the pixels isolate them while providing a high fill-factor. Here, in this paper, we present a variation of this latter approach, demonstrating its feasibility by means of 2-dimensional TCAD simulations.

47 OTHER INSTRUMENTATION↗

New method for level-lifetime measurements with thick scintillators

Level lifetimes provide key insight into the structure of atomic nuclei and serve as stringent tests of theoretical descriptions. Though several methods for determining level lifetimes exist for both reaction measurements and decay studies, here the focus is on techniques involving the direct measurement of time differences between population and subsequent depopulation of excited states. The techniques presented herein are broadly applicable across multiple timing ranges, but the approach is specifically described for the βγ timing method. A multi-step, amplitude-dependent time walk correction was employed to address the data analysis complications that arise from using thick scintillators for electron detection. Further, additional corrections for the depth of the interaction must also be performed when the parent isotope has been implanted into the detector. Techniques are presented for performing these time walk and depth of interaction corrections. Subsequently, a new Monte Carlo method utilizing measured detector responses obtained from the data, coupled with chi-square minimization, is presented for extracting excited state lifetimes ≳ 100 picoseconds. The framework of this Monte Carlo method is developed for the decay of a state in 68 Zn with a known 1.6 ps half life, which is considered prompt given the detection sensitivity of the technique, and then benchmarked using two other excited states in neutron-rich Ni isotopes with 120(34) ps and 1.05(3) ns half lives. Using this new method which takes into account the thick scintillator used, these same half lives were measured to be 135(10) ps and 1.04(24) ns, respectively. The overall good agreement demonstrates the validity of the technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a precise-timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and a Micromegas amplifying structure, targeting a time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a time resolution below σ = 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B 4 C), is pursued. Results from prototypes equipped with DLC and B 4 C photocathodes exhibited a time resolution of σ ≈ 32 ps and σ ≈ 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-assisted embedding of all-glass optical fiber sensors into bulk ceramics for high-temperature applications

We develop a laser-assisted sensor embedding process to embed all-glass optical fiber sensors into bulk ceramics for high-temperature applications. A specially designed two-step microchannel was fabricated on an Al 2 O 3 substrate for sensor embedment using a picosecond (ps) laser. An optical fiber Intrinsic Fabry-Perot Interferometer (IFPI) sensor was embedded at the bottom of the microchannel and covered by Al 2 O 3 slurry which was subsequently sintered by a CO 2 laser. The sensor spectrum was in-situ monitored during the laser sintering process to ensure the survival of the sensor and optimize the laser sintering parameters. By testing in furnace through high temperature, the embedded optical fiber shows improved stability after CO 2 laser sealing, resulting in the linear temperature response of the embedded optical fiber IFPI sensor. To improve the embedded IFPI sensor for thermal strain measurement, a dummy fiber was co-embedded with the sensing fiber to improve the mechanical bonding between the sensing fiber and the ceramic substrate so that the thermal strain of the ceramic substrate can apply on the sensing fiber. The response sensitivity, measurement repeatability and high-temperature long-term stability of the embedded optical fiber IFPI sensor were evaluated in this work.

47 OTHER INSTRUMENTATION↗

Radiolytic degradation of n -dodecane: Insights from time resolved pulsed electron radiolysis using aromatic scavengers

This study uses time-resolved picosecond pulsed electron radiolysis and transient absorbance spectroscopy to investigate early radiolytic processes in n-dodecane, a prototypical organic solvent for reprocessing used nuclear fuel (UNF). The primary radical cation, solvated electron, and excited states in neat n-dodecane are formed and consumed on timescales that are difficult to observe directly. Aromatic solutes, biphenyl and benzophenone, were utilized as scavengers to convert these short-lived species into longer-lived, optically detectable transient products to serve as indirect probes of the fraction of the initial n-dodecane radiolytic products that can be intercepted before undergoing ultrafast decay or competing reactions. The transient absorbance spectra of these scavengers and their radiolytic products were analyzed. Results indicate that while biphenyl and benzophenone effectively capture several radiolytic species, they do not fully scavenge all n-dodecane excited states, suggesting potential inefficiencies or additional side reactions. This study provides insight into the formation and accessibility of radiation-induced excited states and charge carriers in n-dodecane, which play a key role in the degradation of solvent extraction systems used in UNF reprocessing.

58 GEOSCIENCES↗

Stroboscopic ultrafast imaging using RF strip-lines in a commercial transmission electron microscope

The development of ultrafast electron microscopy (UEM), specifically stroboscopic imaging, has brought the study of structural dynamics to a new level by overcoming the spatial limitations of ultrafast spectroscopy and the temporal restrictions of traditional TEM simultaneously. Combining the concepts governing both techniques has enabled direct visualization of dynamics with spatiotemporal resolutions in the picosecond-nanometer regime. Here, in this study, we push the limits of imaging using a pulsed electron beam via RF induced transverse deflection based on the newly developed 200 keV frequency-tunable strip-line pulser. We demonstrate 0.2 nm spatial resolution at high magnifications and elucidation of Lorentz imaging using the phase-microscopy method. We also present beam coherence measurements and expand our study using the breathing modes of a silicon interdigitated comb under RF excitation which achieves improved temporal synchronization between the electron pulse-train and electric field. A new RF holder has also been developed with impedance matching to the RF signal to minimize transmission power loss to samples and its performance is compared with a conventional sample holder.

47 OTHER INSTRUMENTATION↗

Proton deflectometry of a capacitor coil target along two axes

A developing application of laser-driven currents is the generation of magnetic fields of picosecond–nanosecond duration with magnitudes exceeding $B=10~\text{T}$. Single-loop and helical coil targets can direct laser-driven discharge currents along wires to generate spatially uniform, quasi-static magnetic fields on the millimetre scale. Here, we present proton deflectometry across two axes of a single-loop coil ranging from 1 to 2 mm in diameter. Comparison with proton tracking simulations shows that measured magnetic fields are the result of kiloampere currents in the coil and electric charges distributed around the coil target. Using this dual-axis platform for proton deflectometry, robust measurements can be made of the evolution of magnetic fields in a capacitor coil target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulse-length dependence of the laser-induced damage behavior of a fused-silica antireflective metasurface

A broadband, antireflective metasurface optic on a silica substrate is subjected to laser-induced damage-threshold measurements to quantify its performance under exposure to high-intensity/fluence laser pulses in the near-infrared at four pulse durations, ranging from 20 fs to 1.4 ns. The performance of the metasurface is benchmarked against that obtained from an equivalent bare fused-silica substrate that did not receive reactive-ion-etching metasurface treatment. Results showed that the damage threshold of the antireflective metasurface was always lower than the input-surface damage threshold of the untreated substrate. The damage initiations with nanosecond and picosecond pulses resulted in localized modification and removal of the nanostructures, whereas the onset of laser-induced modification with 20-fs pulses in a vacuum environment manifested as changes in the optical and electronic properties without significant material removal. The broader goal of this work is to develop a preliminary understanding of the laser-induced failure mechanisms of silica-based metasurface optics.

antireflection↗

Suppression and enhancement of electromagnetic pulses from laser–target interactions by strong magnetic fields

Laser–target interactions generate intense electromagnetic pulses (EMPs) that can interfere with measurements and damage equipment. In this paper we show that applying a magnetic field to nanosecond pulse laser–target interactions decreases the magnitude of EMPs. We demonstrate this effect in two experiments with different geometries (spherical versus planar), laser intensities ( ∼10 13 versus ∼10 15 W/cm 2 ) and applied field strength (12 versus 0.1 T) that both observed suppression of EMPs in approximately the 1 GHz band (by factors of 0.65× and 0.32×, respectively). We then observe the opposite effect at high intensities with a picosecond pulse: for planar experiments with laser intensities of approximately 10 19 W/cm 2 and magnetic fields of 6–10 T, the magnitude of EMPs is increased by a factor of 1.75×. These results provide a benchmark for models of EMP generation, but suggest that magnetic fields are not a viable solution for mitigating EMPs in the high-intensity laser facilities where they are most damaging.

electromagnetic pulse↗

Evaluation of Nanostructured β-Mn 2 V 2 O 7 Thin Films as Photoanodes for Photoelectrochemical Water Oxidation

β-Mn 2 V 2 O 7 (β-MVO) was recently reported to be a promising candidate for photoelectrochemical (PEC) water splitting, with a suitable band gap and band edge positions and reasonable stability and photoactivity in preliminary tests in alkaline solution. Here, we present an in-depth evaluation of the PEC performance and stability of phase-pure nanostructured β-Mn 2 V 2 O 7 films made by calcination of a spin-cast molecular ink. We show that β-Mn 2 V 2 O 7 dissolves in pure water, corrodes in aqueous electrolytes at pH 7 and 9, and converts to amorphous manganese (hydr)oxides within minutes at pH 13. Our β-Mn 2 V 2 O 7 films yielded only miniscule photocurrents (~uA cm -2 ) for the oxidation of iodide, sulfite, or water and the reduction of iodate or water in borate- and phosphate-buffered electrolytes at pH 7 and 9, the oxidation of [Fe(CN) 6 ] 4- or water at pH 13, and the oxidation of bromide in acetonitrile, regardless of film calcination temperature and time, film thickness, and illumination geometry. Minimal photoactivity was observed even in electrolytes in which film degradation was insignificant over the duration of the PEC tests. Ultrafast transient absorption spectroscopy shows that the poor photoactivity is likely the result of fast hole trapping and recombination at the MVO surface that leaves few free charge carriers beyond the picosecond time scale. Given its poor charge transport/extraction and chemical stability, native nanostructured β-Mn 2 V 2 O 7 is ineffective for solar water splitting and future research on this material should focus on the development of superior syntheses and film morphologies, MVO alloys, heterostructures, and surface coatings to alleviate recombination and boost operational stability. This work underscores the importance of careful follow-up studies of materials identified as "hits" in combinatorial materials discovery campaigns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excited-State Dynamics and Nonlinear Optical Properties of Hyperpolarizable Chromophores Based on Conjugated Bis(terpyridyl)Ru(II) and Palladium and Platinum Porphyrinic Components: Impact of Heavy Metals upon Supermolecular Electro-Optic Properties

A new series of strongly coupled oscillators based upon (porphinato)Pd, (porphinato)Pt, and bis(terpyridyl)-ruthenium(II) building blocks is described. These RuPPd, RuPPt, RuPPdRu, and RuPPtRu chromophores feature bis- (terpyridyl)Ru(II) moieties connected to the (porphinato)metal unit via an ethyne linker that bridges the 4!-terpyridyl and porphyrin macrocycle meso-carbon positions. Pump–probe transient optical data demonstrate sub-picosecond excited singlet-to-triplet-state relaxation. The relaxed lowest-energy triplet (T 1 ) excited states of these chromophores feature absorption manifolds that span the 800–1200 nm spectral region, microsecond triplet-state lifetimes, and large absorptive extinction coefficients [ε(T 1 → T n ) > 4 × 10 4 M –1 cm –1 ]. Dynamic hyperpolarizability (β λ ) values were determined from hyper-Rayleigh light scattering (HRS) measurements carried out at several incident irradiation wavelengths over the 800–1500 nm spectral region. Relative to benchmark RuPZn and RuPZnRu chromophores which showed large βHRS values over the 1200–1600 nm range, RuPPd, RuPPt, RuPPdRu, and RuPPtRu displayed large βHRS values over the 850–1200 nm region. Generalized Thomas–Kuhn sum (TKS) rules and experimental hyperpolarizability values were utilized to determine excited state-to-excited state transition dipole terms from experimental electronic absorption data and thus assessed frequency-dependent β λ values, including two- and three-level contributions for both β zzz and β xzx tensor components to the RuPPd, RuPPt, RuPPdRu, and RuPPtRu hyperpolarizability spectra. Furthermore, these analyses qualitatively rationalize how the βzzz and βxzx tensor elements influence the observed irradiation wavelength-dependent hyperpolarizability magnitudes. The TKS analysis suggests that supermolecules related to RuPPd, RuPPt, RuPPdRu, and RuPPtRu will likely feature intricate dependences of experimentally determined βHRS values as a function of irradiation wavelength that derive from substantial singlet–triplet mixing, and complex interactions among multiple different β tensor components that modulate the long wavelength regime of the nonlinear optical response.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long-Lived Photoluminescence of Molecular Group 14 Compounds through Thermally Activated Delayed Fluorescence

Photoluminescent molecules exploiting the sizable spin-orbit coupling constants of main group metals and metalloids to access long-lived triplet excited states are relatively rare compared to phosphorescent transition metal complexes. Here we report the synthesis of three air- and moisture-stable group 14 compounds E( Me PDP Ph ) 2 , where E = Si, Ge, or Sn and [ Me PDP Ph] 2- is the doubly deprotonated form of 2,6-bis(5- methyl-3-phenyl-1H-pyrrol-2-yl)pyridine. In solution, all three molecules exhibit exceptionally long-lived triplet excited states with lifetimes in the millisecond range and show highly efficient photoluminescence (Φ ≤ 0.49) due to competing prompt fluorescence and thermally activated delayed fluorescence at and around room temperature. Temperature-dependent steady-state emission spectra and photoluminescent lifetime measurements provided conclusive evidence for the two distinct emission pathways. Picosecond transient absorption spectroscopy allowed further analysis of the intersystem crossing (ISC) between singlet and triplet manifolds (τ ISC = 0.25-3.1 ns) and confirmed the expected trend of increased ISC rates for the heavier elements in otherwise isostructural compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transient Radiation-Induced Berkelium(III) and Californium(III) Redox Chemistry in Aqueous Solution

Despite the significant impact of radiation-induced redox reactions on the accessibility and lifetimes of actinide oxidation states, fundamental knowledge of aqueous actinide metal ion radiation chemistry is limited, especially for the late actinides. A quantitative understanding of these intrinsic radiation-induced processes is essential for investigating the fundamental properties of these actinides. We present here a picosecond electron pulse reaction kinetics study into the radiation-induced redox chemistry of trivalent berkelium (Bk(III)) and californium (Cf(III)) ions in acidic aqueous solutions at ambient temperature. New, and first of a kind, second-order rate coefficients are reported for the transient radical-induced reduction of Bk(III) and Cf(III) by the hydrated electron (eaq−) and hydrogen atom (H•), demonstrating significant reactivity (up to 1011M-1s-1) indicative of a preference of these metals to adopt divalent states. Additionally, we reportthe first-ever second-order rate coefficients for the transient radical-induced oxidation of these elements by reaction with hydroxyl (•OH) and nitrate (NO3•) radicals, which also exhibited fast reactivity (ca. 108 M-1s-1). Transient Cf(II), Cf(IV), and Bk(IV) absorption spectra are also reported. Overall, the presented data highlight the existence of rich, complex, intrinsic late actinide radiation-induced redox chemistry that has the potential to influence the findings of other areas of actinide science.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗