Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phasor measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

226 records · Page 13

Intensity Modulated Fiber Optic Sensor: A Novel Grid Measurement Unit

This paper presents a novel approach to physical displacement-based power grid measuring via an Intensity Modulated Fiber Optic Sensor (IMFOS). An IMFOS utilizes one fiber to transmit the intensity modulation light from its Electro-Optic controller to a fiber optic probe. The power grid voltage and current can induce physical displacements in transducers via the piezoelectric effect and the Lorentz law, respectively, which then result in a distance change between the optical probe and the reflective surface of the transducers. In parallel, multiple fibers are used to collect the reflective light for electro-optic conversion. Furthermore, a National Instruments-based characterization platform is set up for performance evaluation. Here, the testing result demonstrates that the IMFOS is immune to the inherent DC and low-frequency saturation issues prevalent in conventional potential and current transformers. Finally, the IMFOS is implemented in a Universal Grid Analyzer to illustrate its applicability for phasor estimation in actual power grids.

42 ENGINEERING↗

Extended Frequency Divider for Bus Frequency Estimation Considering Virtual Inertia from DFIGs

Accurate estimation of local bus frequency is important for effectively controlling both synchronous and nonsynchronous generators. As the power grid evolves to accommodate essential reliability services such as virtual inertia from nonsynchronous generators, conventional techniques to estimate frequency face challenges. This paper proposes a new frequency estimation method that can effectively include the inertia contributions from double-fed wind generators (DFIGs). This is achieved through the proposed extended frequency divider formula (FDF) to include the contributions of DFIGs via Thevenin equivalents. The proposed extended FDF does not suffer from numerical issues as compared to existing phasor angle derivative-based approaches. Moreover, the knowledge of the rotor speeds of the synchronous machine and DFIGs as well as of the network admittance matrix allows estimating the frequencies of all buses in the grid, thereby significantly improving system situational awareness with a limited number of measurements. Numerical results on the IEEE 39-bus power system with DFIGs show that the proposed method achieves more accurate bus frequency estimations than the original FDF formula and other approaches based on the numerical derivation of the bus voltage phase angles.

double-fed induction generator↗

Impedance Analysis and PHIL Demonstration of Reactive Power Oscillations in a Wind Power Plant Using a 4-MW Wind Turbine

This paper presents impedance-based analysis, mitigation, and power-hardware-in-the-loop (PHIL) demonstration of reactive power oscillations in a wind power plant using a 4-MW Type III wind turbine drivetrain. Because such low-frequency oscillations result from interactions among slower control loops of wind turbines regulating phasor quantities—active and reactive power output of the wind turbine and the magnitude of voltages at the point of interconnection (POI)—a new type of admittance is defined in terms of phasor quantities for their analysis. The so-called power-domain admittance of a wind turbine is defined as the transfer function from the frequency and magnitude of voltages at the POI to the active and reactive power output of the turbine. The power-domain admittance responses of the 4-MW wind turbine are measured using a 7-MVA grid simulator to identify the source of the reactive power oscillations. Power-domain impedance analysis and PHIL experiments are performed to explain how a resonant mode manifests as turbine-to-turbine and plant-to-grid reactive power oscillations. It is discovered that weaker grids exhibiting high inductive impedance mitigate oscillations in the reactive power output of wind power plants; however, a higher grid impedance does not help in damping turbine-to-turbine reactive power oscillations. This paper presents a simple droop-based solution to eliminate both turbine-to-turbine and plant-to-grid reactive power oscillations.

17 WIND ENERGY↗

Development and experimental test of an analytical model of the orifice pulse tube refrigerator

An analytical model for the orifice pulse tube is developed, in which the system is described in terms of average enthalpy flow with such simplifying assumptions as an ideal gas and sinusoidal pressure variation. Phasor analysis is used to represent temperature, pressure, and mass-flow rate waves in vector form. The model predictions, namely, that the refrigeration power of a pulse-tube refrigerator is proportional to the average pressure, the pulse frequency, the mass-flow ratio, and the square of the dynamic pressure ratio, were verified by experimental measurements. It was found that, as a result of the simplifying assumptions, the magnitudes of the refrigeration power predicted by the model were between three and five times greater than experimental values.

Storch, Peter J.↗

Suppressing interfering scattered signals in swept-frequency radar measurements by using frequency domain Wiener filtering

A novel approach to the reduction of scattered, interfering signals that corrupt measurements of the signal backscattered from radar targets of interest is being developed. It is being explored with sphere measurements in an indoor microwave radar range. This method is based on the concept of Wiener filtering (which minimizes the difference between the signal plus noise and the desired signal in the time domain). In contrast to the traditional Wiener filter, in which the time domain error between two sequences are minimized, the approach reported uses the frequency domain phasor amplitudes of a swept frequency signal. It minimizes the difference (least-mean-square-magnitude) between the signal-plus-noise and the signal complex phasors, across the entire spectrum.

Weissman, David E.↗

Enhanced Tensor Completion Based Approaches for State Estimation in Distribution Systems

Grid state estimation is essential for effective control and management of distribution systems. While weighted least squares has been the conventional method for state estimation, sparsity-aware methods have become popular due to their superior performance with limited data. Matrix completion and compressed sensing-based state estimation approaches exploit the underlying smoothness in the state variables. However, classic matrix completion methods do not take into account the temporal correlation of system states. Compressed sensing methods, on the other hand, require an appropriate choice of sparsifying basis that may not be easy to identify. This paper proposes a blocktensor completion based framework which uses an alternative approach to estimate voltage phasor, power injections and branch currents. This approach utilizes the temporal correlation of the system states in a tensor trace-norm minimization formulation with power flow equations as constraints. Herein, feature scaling is introduced in the problem formulation to benefit from the improved sensitivity of the tensor trace norm to the matrix columns in the scaled unfoldings of the tensor. Weighted tensor norm is utilized to exploit the structures of the different unfoldings of the state measurement tensor to improve the voltage estimation. The estimation accuracy is further improved by alternatively estimating the tensor columns and increasing the available data at each stage in the tensor completion process. The proposed methods are evaluated on the IEEE-33, 37 test systems and a 100- node test system. The proposed methods are shown to provide significant performance gains relative to the classic matrix and tensor completion based approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detection of Stealthy False Data Injection Attacks in Unobservable Distribution Networks

In this paper, a composite scheme is proposed for detecting stealthy data manipulation attacks on distribution system which is unobservable with standard least squares based state estimators. This technique has three stages where the process of data imputation, voltage phasor estimation and the bad data detection are carried out in a systematic manner. The proposed approach is then integrated with moving target defense strategies which perturbs the network parameters to reveal stealthy false data injection attacks. The proposed approach is tested is validated on a three-phase, unbalanced 37-node distribution system and its results are presented. It is shown that the proposed approach has the ability to accurately detect the presence of FDI attacks using limited measurements (i.e., the test system is unobservable).

Rajasekaran, James K.↗

Optical properties of Mo and amorphous MoOx, and application to antireflection coatings for metals

To form antireflection (AR) coatings to hide metal architecture in display technologies, we deposited thin films of metal Mo and oxide MoOx by sputtering targets of various compositions using pure Ar sputter gas. The optical constants [n,k] of these samples were measured by the direct numerical solution of reflectance and transmittance at each wavelength point measured. We find that 50 nm films are uniform in the growth direction, but for thicker 100 nm samples, evidence exists for nonuniform growth, where the top 20 nm appears to be metal rich. From these [n,k], negative Tauc bandgap energies show these oxides are semi-metals. We then identified the specific composition (x) that optimizes the AR response for a host of metals (Al, Cu, Ag, Au). Finally, two methods were used to understand why these MoOx materials function well as AR media, including (i) using phasor rays and (ii) developing a universal expression for the AR condition that applies to both dielectric and metal substrates. In (i), we find two characteristics for AR of metals: (a) its optical thickness should be roughly π3, not the π2 for dielectrics, since for MoOx, their [r^ij,t^ij] Fresnel phases differ from the usual [180°, 0°] of dielectrics; and (b) the medium incorporates a k-dominant strategy whose function is to absorb the energy that is reflected at the AR/metal interface. In (ii), the universal AR condition is found to be r^01+r^12z^=0. For dielectrics, this reduces to the well-known nAR=nairnsub condition. However, for metals, a concise analytic expression is lacking since this expression is highly nonlinear but is easily solved by numerical methods.

Tsu, David V. (ORCID:0000000295903418)↗

Influence of Control and Limiter Schemes on Sequence-Domain Fault Models of Grid-Forming Inverter-Interfaced Distributed Generators

Unlike synchronous generators, the fault response of grid-forming (GFM) inverter-interfaced distributed generators (IIDGs) is notably governed by the selection of control and current limiting strategies rather than inherent physical traits. While recent research has focused on the sequence domain fault model of GFM IIDGs, a research gap exists in elucidating the influence of control and current limiting schemes on this model's characteristics. This article aims to fill this void by examining how different control and current limiting schemes influence the positive and negative sequence impedances in the phasor-domain fault model of GFM IIDGs. This investigation encompasses droop-based, virtual synchronous machine-based, and virtual oscillator-based reference generation controls alongside rotating and stationary reference-frame-based voltage controls. Furthermore, saturation-based, latching-based, circular and virtual impedance-based current limiting schemes are analyzed. To achieve this goal, a thorough numerical simulation study is conducted. Findings indicate that outer reference generation controls exhibit minimal impact. Conversely, the choice of voltage control and various current limiting schemes emerge as the predominant factors shaping the sequence models of GFM IIDGs. These analyses and results are instrumental in devising reliable protection strategies within inverter-based grids, as a comprehensive understanding of electrical elements in the sequence domain is imperative for effective protective measures.

current limiters↗

Data for "In vitro and in vivo NIR Fluorescence Lifetime Imaging with a time-gated SPAD camera"

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo. Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

2DG↗