Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance improvement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

The Origin of Improved Performance in Boron‐Alloyed Silicon Nanoparticle‐Based Anodes for Lithium‐Ion Batteries

Stabilizing the solid electrolyte interphase (SEI) remains a key challenge for silicon‐based lithium‐ion battery anodes. Alloying silicon with secondary elements like boron has emerged as a promising strategy to improve the cycle life of silicon anodes, yet the underlying mechanism remains unclear. To address this knowledge gap, how boron concentration influences battery performance is systematically investigated. These results show a near‐monotonic increase in cycle lifetime with higher boron content, with boron‐rich electrodes significantly outperforming pure silicon. Additionally, silicon‐boron alloy anodes exhibit nearly three times longer calendar life than pure silicon. Through detailed mechanistic analysis, alternative contributing factors are systematically ruled out, and it is proposed that improved passivation arises from a strong permanent dipole at the nanoparticle surface. This dipole, formed by undercoordinated and highly Lewis acidic boron, creates a static, ion‐dense layer that stabilizes the electrochemical interface, reducing parasitic electrolyte decomposition and enhancing long‐term stability. These findings suggest that, within the SEI framework, the electric double layer is an important consideration in surface passivation. This insight provides an underexplored parameter space for optimizing silicon anodes in next‐generation lithium‐ion batteries.

25 ENERGY STORAGE↗

Estimation of Crop Gross Primary Production (GPP): Do Scaled (MODIS) Vegetation Indices Improve Performance? - 2

Satellite remote sensing estimates of Gross Primary Production (GPP) have routinely been made using spectral Vegetation Indices (VIs) over the past two decades. The Normalized Difference Vegetation Index (NDVI), the Enhanced Vegetation Index (EVI), the green band Wide Dynamic Range Vegetation Index (WDRVIgreen), and the green band Chlorophyll Index (CIgreen) have been employed to estimate GPP under the assumption that GPP is proportional to the product of VI and photosynthetically active radiation (PAR) (where VI is one of four VIs: NDVI, EVI, WDRVIgreen, or CIgreen). However, the empirical regressions between VI*PAR and GPP measured locally at flux towers do not pass through the origin (i.e., the zero X-Y value for regressions). Therefore they are somewhat difficult to interpret and apply. This study investigates (1) what are the scaling factors and offsets (i.e., regression slopes and intercepts) between the fraction of PAR absorbed by chlorophyll of a canopy (fAPARchl) and the VIs, and (2) whether the scaled VIs developed in (1) can eliminate the deficiency and improve the accuracy of GPP estimates. Three AmeriFlux maize and soybean fields were selected for this study, two of which are irrigated and one is rainfed. The four VIs and fAPARchl of the fields were computed with the MODerate resolution Imaging Spectroradiometer (MODIS) satellite images. The GPP estimation performance for the scaled VIs was compared to results obtained with the original VIs and evaluated with standard statistics: the coefficient of determination (R2), the root mean square error (RMSE), and the coefficient of variation (CV). Overall, the scaled EVI obtained the best performance. The performance of the scaled NDVI, EVI and WDRVIgreen was improved across sites, crop types and soil/background wetness conditions. The scaled CIgreen did not improve results, compared to the original CIgreen. The scaled green band indices (WDRVIgreen, CIgreen) did not exhibit superior performance to either the scaled EVI or NDVI in estimating crop daily GPP at these agricultural fields. The scaled VIs are more physiologically meaningful than original un-scaled VIs, but scaling factors and offsets may vary across crop types and surface conditions.

Vegetation Index↗

Improved performance of silicon nitride-based high temperature ceramics

Recent progress in the production of Si3N4 based ceramics is reviewed: (1) high temperature strength and toughness of hot pressed Si3N4 were improved by using high purity powder and a stabilized ZrO2 additive, (2) impact resistance of hot pressed Si3N4 was increased by the use of a crushable energy absorbing layer, (3) the oxidation resistance and strength of reaction sintered Si3N4 were increased by impregnating reaction sintered silicon nitride with solutions that oxidize to Al2O3 or ZrO2, (4) beta prime SiA1ON compositions and sintering aids were developed for improved oxidation resistance or improved high temperature strength.

Ashbrook, R. L.↗

Enabling off-highway diesel engine downsizing and performance improvement using electrically assisted turbocharging

Internal combustion engine (ICE) downsizing through various turbocharging configurations is generally known by the powertrain design community as an effective means to reduce frictional losses, increase waste heat recovery, and improve fuel efficiency while increasing engine power density. However, often is the case that turbocharging strategies, including variable geometry turbochargers, and regulated two-stage turbochargers, incur the performance tradeoff between transient response and fuel economy (pumping losses) at high engine speeds. For off-highway vehicles having particularly transient and high-powered duty cycles, efforts to improve this tradeoff and increase operational flexibility have turned to evaluating various electrified air system architectures. In this study, a 4.5 L diesel-ICE configured with an electrically driven compressor (eBooster ® ) is placed in series with a conventional turbocharger and integrated into a 48 V mild-hybrid powertrain architecture. The objective of this powertrain configuration is to enable engine downsizing by 34%, replacing the current 6.8 L ICE platform with the hybridized 4.5 L ICE concept. The commercial 1-D simulation software GT-SUITE is used for powertrain system development and system optimization. Development and validation of the GT-SUITE model and air system controls is concurrently supported through experimental data collection. The simulation model development includes using machine learning methods for optimizing exhaust gas dilution, injection timing, and eBooster ® power to improve steady-state and transient brake-specific fuel consumption while minimizing criteria pollutant emissions. It was found that total specific fluid consumption over the standardized non-road transient engine duty cycle could be reduced by 18% over the current 6.8 L engine by using an optimized eBoosted 4.5 L engine. The hybridized 4.5 L engine concept concurrently showed sufficient transient response capability and nearly an order of magnitude reduction in duty cycle total soot production.

25 ENERGY STORAGE↗

Performance Improvements to the Prototype Design of the AGU

The existing design for the Magnet Structure of the prototype multi-segment AGU (Adaptive- Gap Undulator) has undergone analysis (see TN #298). To optimize performance, after review of said analysis, certain design modifications are proposed herein. A primary constraint of this proposed design is to use the existing fabricated parts from initial assembly SR-ID-SAGU-4300 with three pairs of feed-throughs spaced along the platen length of a single segment, but with foresight for the eventual multi-segment prototype. Measurements of the center segment are to be conducted on the frame and gap-drive system of the NSLS X9 MGU with its single driven axis. The eventual multi-segment prototype will also use the sister devices (X13, X27) for simultaneous measurement of both central and outboard segments at various segment gaps. Criteria effecting IVU performance like Gap Tolerance, Taper Error, and the critical Planarity of pole plane as in Figure 1 are used to evaluate the design. The error in planarity to be minimized is the deviation of vertical displacement (Y direction) with Platen length (beam Z direction).

36 MATERIALS SCIENCE↗

Electrolyte additive to improve performance of MCMB LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2} Li-ion cell.

The electrolyte additive, 3,9-divinyl-2,4,8,10-tetraoxaspiro[5,5] undecane (TOS), was investigated as a means to improve the life of mesocarbon microbead (MCMB)/Li1.1[Ni1/3Co1/3Mn1/3]0.9O2 (NCM) cells for high-power applications. With the addition of an appropriate amount of TOS (no more than 1 wt%) to MCMB/NCM cells, the capacity retention was significantly improved at 55 C compared with cells containing pristine electrolyte. Aging tests at 55 C indicated that the capacity retention of the negative electrode had benefited as a result of the formation of a stable passivation film at the surface of the carbon electrode due to TOS reduction. Electrochemical impedance spectroscopy showed that a TOS addition of more than 0.5 wt% increased the cell interfacial impedance. Differential scanning calorimetry showed that the thermal stability of lithiated MCMB was also improved with the TOS addition.

36 MATERIALS SCIENCE↗

Overcoats for the Improved Performance of PdCr High Temperature Thin Film Strain Gages

Overcoat protection schemes for thin film devices have typically focused on inhibiting the growth of native oxides formed on the sensor surface, rather than on improving the passivating nature of these native oxides. Here, thin sputtered Cr overcoats and heat treatments in varying oxygen partial pressures enhanced the passivating nature of native Cr203 films formed on PdCr thin film strain gages. Results of strain tests using sensors protected using this approach are presented and the implications are discussed. PdCr gages with sputtered Cr overcoats withstood 12,000 dynamic strain cycles of 1100 micro-epsilon during 100 hours of testing at a temperature of 1000 C in air. Gage factors of 1.3 with drift rates as low as 0.1 Omega/hr were achieved for devices having a nominal resistance of approximately 100 Omega's. TCR's ranging from +550 ppm/C to +798 ppm/C were realized depending on the overcoat and thermal history. Possible mechanisms for an anomaly in the electrical characteristics of these films at 800 C and improvements in stability due to the use of overcoats are presented.

Gregory, Otto J.↗

Improved Performance of All‐Polymer Solar Cells Enabled by Naphthodiperylenetetraimide‐Based Polymer Acceptor

A new polymer acceptor, naphthodiperylenetetraimide‐vinylene (NDP‐V), featuring a backbone of altenating naphthodiperylenetetraimide and vinylene units is designed and applied in all‐polymer solar cells (all‐PSCs). With this polymer acceptor, a new record power‐conversion efficiencies (PCE) of 8.59% has been achieved for all‐PSCs. The design principle of NDP‐V is to reduce the conformational disorder in the backbone of a previously developed high‐performance acceptor, PDI‐V, a perylenediimide‐vinylene polymer. The chemical modifications result in favorable changes to the molecular packing behaviors of the acceptor and improved morphology of the donor–acceptor (PTB7‐Th:NDP‐V) blend, which is evidenced by the enhanced hole and electron transport abilities of the active layer. Moreover, the stronger absorption of NDP‐V in the shorter‐wavelength range offers a better complement to the donor. All these factors contribute to a short‐circuit current density ( J sc ) of 17.07 mA cm −2 . With a fill factor (FF) of 0.67, an average PCE of 8.48% is obtained, representing the highest value thus far reported for all‐PSCs.

Guo, Yikun↗

2025 Advances in NekRS: Supporting improved performance for nuclear applications

This report presents several 2025 advancements in NekRS, a high-fidelity spectral element CFD code developed at Argonne National Laboratory to support the NEAMS thermal-hydraulics program. The forthcoming v25 release consolidates several of these advances, adding new features for portability across heterogeneous GPU architectures, real-time in situ visualization, improved turbulence modeling, and conjugate heat transfer coupling. Over the past year, NekRS has demonstrated strong scalability and performance on DOE’s leading exascale platforms, including Aurora and Frontier, confirming its readiness for some of the largest and most complex simulations attempted to date. These achievements provide a powerful new platform for high-fidelity data generation, which in turn supports the development and validation of advanced closure models critical for reactor safety and design. Significant algorithmic innovations have also been introduced. A new global runtime h-refinement capability simplifies workflows by reducing mesh preparation burdens and enabling coarse-to-fine restarts. Building on this, a novel multigrid strategy was implemented to accelerate pressure and transport solves at scale, addressing long-standing bottlenecks in exascale CFD. Together, these developments improve both the efficiency and accessibility of high-fidelity simulations for reactor-relevant problems. Collectively, these enhancements represent a major step forward in simulation technology, positioning NekRS as a cornerstone of NEAMS efforts to enable accurate, efficient, and scalable high-fidelity analysis of advanced nuclear systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Studying Wind Loading on CSP Collectors to Improve Performance and Reliability

Electricity generation through Concentrating Solar-thermal Power (CSP) adds the advantage of thermal energy storage and heat production. CSP collector costs constitute nearly one-third of total plant costs. Managing wind loading, especially dynamic wind loading caused by the turbulent wind flow, is a significant design challenge. Traditional collector designs rely on wind tunnel experiments and numerical simulations, which do not fully capture dynamic effects. Here, we provide an overview of NREL's activities on wind loading on CSP collectors, aiming to improve their reliability and cost-efficiency. We present insights from field measurements at operational parabolic trough and power-tower CSP plants. Over two years, we measured turbulent wind fields and resulting structural loads in a parabolic trough plant, revealing wind, turbulence, and collector field interactions. Similar measurements are ongoing at the Crescent Dunes heliostat field. These campaigns show how atmospheric turbulence, wind direction, and collector orientation affect dynamic wind loading. Upwind collector structures can generate turbulent structures, causing fluctuating loads at downstream collectors, impacting fatigue lifetime and optical efficiency. Preliminary results indicate that interior collectors experience higher turning moments than those at the edges, suggesting higher drive wear. At Crescent Dunes, we use instrumented heliostats at the field's edge and interior to study the translation of turbulent wind to dynamic structural loads. The campaign is still ongoing, and we will present first findings. Another focus of our work is tying the experimental wind loading findings to optical performance of the collectors, using simulation tools. For example, we derive torsional errors of the parabolic troughs - the angular offset from the sun position along a collector row. This error is impacted by wind-induced mirror deformations. Future work will focus on continuing the measurement efforts and combining them with computational fluid dynamic simulations. By providing detailed field measurements and validated models, our efforts aim to enhance understanding of wind loading on CSP collectors, improving their structural integrity and optical performance.

CSP↗

Building America Case Study: Advanced Controls Improve Performance of Combination Space and Water Heating Systems, Minneapolis, Minnesota

The combined space and water heating systems (combi) uses a high efficiency direct vent burner that eliminates safety issues associated with natural draft appliances. Past research with these systems shows that utilizing condensing water heaters or boilers with hydronic air handlers can provide both space and water heating with efficiencies of 90% or greater. Improved controls have the potential to reduce some of this complexity and boost the measured performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Report of improved performance in Talbot–Lau phase-contrast computed tomography

Purpose: Many expectations have been raised since the use of conventional x-ray tubes on grating-based x-ray phase-contrast imaging. Despite a reported increase in contrast-to-noise ratio (CNR) in many publications, there is doubt on whether phase-contrast computed tomography (CT) is advantageous in clinical CT scanners in vivo. The aim of this paper is to contribute to this discussion by analyzing the performance of a phase-contrast CT laboratory setup. Methods: A phase-contrast CT performance analysis was done. Projection images of a phantom were recorded, and image slices were reconstructed using standard filtered back projection methods. The resulting image slices were analyzed by determining the CNRs in the attenuation and phase image. These results were compared to analytically calculated expectations according to the already published phase-contrast CT performance analysis by Raupach and Flohr [Med. Phys. 39, 4761–4774 (2012)]. There, a severe mistake was found leading to wrong predictions of the performance of phase-contrast CT. The error was corrected and with the new formulae, the experimentally obtained results matched the analytical calculations. Results: The squared ratios of the phase-contrast CNR and the attenuation CNR obtained in the authors’ experiment are five- to ten-fold higher than predicted by Raupach and Flohr [Med. Phys. 39, 4761–4774 (2012)]. The effective lateral spatial coherence length deduced outnumbers the already optimistic assumption of Raupach and Flohr [Med. Phys. 39, 4761–4774 (2012)] by a factor of 3. Conclusions: The authors’ results indicate that the assumptions made in former performance analyses are pessimistic. The break-even point, when phase-contrast CT outperforms attenuation CT, is within reach even with realistic, nonperfect gratings. Further improvements to state-of-the-art clinical CT scanners, like increasing the spatial resolution, could change the balance in favor of phase-contrast computed tomography even more. This could be done by, e.g., quantum-counting pixel detectors with four-fold smaller pixel pitches.

60 APPLIED LIFE SCIENCES↗

Predicted roles of defects on band offsets and energetics at CIGS (Cu(In,Ga)Se 2 /CdS) solar cell interfaces and implications for improving performance

The laboratory performance of CIGS (Cu(In,Ga)Se 2 ) based solar cells (20.8% efficiency) makes them promising candidate photovoltaic devices. However, there remains little understanding of how defects at the CIGS/CdS interface affect the band offsets and interfacial energies, and hence the performance of manufactured devices. To determine these relationships, we use density functional theory with the B3PW91 hybrid functional that we validate to provide very accurate descriptions of the band gaps and band offsets. This confirms the weak dependence of band offsets on surface orientation observed experimentally. We predict that the conduction band offset (CBO) of perfect CuInSe2/CdS interface is large, 0.79 eV, which would dramatically degrade performance. Moreover we show that band gap widening induced by Ga adjusts only the valence band offset, and we find that Cd impurities do not significantly affect the CBO. Thus we show that Cu vacancies at the interface play the key role in enabling the tunability of CBO. We predict that Na further improves the CBO through electrostatically elevating the valence levels to decrease the CBO, explaining the observed essential role of Na for high performance. Moreover we find that K leads to a dramatic decrease in the CBO to 0.05 eV, much better than Na. We suggest that the efficiency of CIGS devices might be improved substantially by tuning the ratio of Na to K, with the improved phase stability of Na balancing phase instability from K. All these defects reduce interfacial stability slightly, but not significantly.

36 MATERIALS SCIENCE↗

Performance Improvement of LTS Undulators for Synchrotron Light Sources

The joint expertise of ANL and FNAL has led to the production of $\text{Nb}_{3}\text{Sn}$ undulator magnets in operation in the ANL Advanced Photon Source (APS). These magnets showed performance reproducibility close to the short sample limit, and a design field increase of 20% at 820 A. However, the long training did not allow obtaining the expected 50% increase of the on-axis magnetic field with respect to the ∼1 T produced at 450 A current in the ANL NbTi undulator. To address this, 10-pole long undulator prototypes were fabricated, and CTD-101K was replaced as impregnation material with TELENE, an organic olefin-based thermosetting dicyclopentadiene resin produced by RIMTEC Corporation, Japan. Training and magnet retraining after a thermal cycle were nearly eliminated, with only a couple of quenches needed before reaching short sample limit at over 1,100 A. TELENE will enable operation of $\text{Nb}_{3}\text{Sn}$ undulators much closer to their short sample limit, expanding the energy range and brightness intensity of light sources. TELENE is Co-60 gamma radiation resistant up to 7–8 MGy, and therefore already applicable to impregnate planar, helical and universal devices operating in lower radiation environments than high energy colliders.

43 PARTICLE ACCELERATORS↗

Hydrogen depolarized carbon dioxide concentrator performance improvements and cell pair structural tests

The investigations and testing associated with the CO2 removal efficiency and voltage degradation of a hydrogen depolarized carbon oxide concentrator are reported. Also discussed is the vibration testing of a water vapor electrolysis cell pair. Performance testing of various HDC cell pairs with Cs2CO3 electrolyte provided sufficient parametric and endurance data to size a six man space station prototype CO2 removal system as having 36 HDC cell pairs, and to verify a life capability exceeding six moths. Testing also demonstrated that tetramethylammonium carbonate is an acceptable HDC electrolyte for operating over the relative humidity range of 30 to 90 percent and over a temperature range of 50 to 80 F.

Huddleston, J. D.↗

Performance improvement of an extraction Lambertson septum magnet in the SNS accumulator ring

The SNS ring Extraction Lambertson Septum magnet contains a strong skew quadrupole term, which has been identified as the source of causing a beam profile distortion on the target. We have performed 3D computer simulations to study the magnetic field quality in the magnet. The skew quad term is computed with different methods in simulations and is compared to measurement data. The origin of the large skew quad term is thoroughly investigated. The remedy for minimizing the skew quad term by modifying the magnet is proposed. Particle tracking is performed to verify the beam profile evolution through the existing and modified septum. The magnetic interference to the septum performance from an adjacent quadrupole is also assessed.

43 PARTICLE ACCELERATORS↗