Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “parametric analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

MCP-enabled agentic AI workflow for building energy modelling: framework and use cases

Traditional building energy modelling workflows remain labor-intensive and error-prone, requiring specialized expertise that limits broader adoption. This paper introduces a novel Model Context Protocol (MCP)-enabled framework that connects AI assistants to EnergyPlus through MCP, a standardized interface for tool invocation and context management. Two complementary integration paradigms are presented and compared: conversational integration, where users interact through natural language while an AI assistant orchestrates MCP tools on demand, and agentic workflow integration, where specialized agents coordinate autonomously to complete multi-step tasks. Using an experimental testbed for residential buildings, the end-to-end workflows are demonstrated. The conversational approach reduced typical inspection and modification tasks from 1-2 h to under 15 min, while maintaining full transparency through visible tool invocations. The agentic approach automated parametric analysis. These demonstrations establish MCP as a foundational layer for AI-assisted building energy modelling, enabling natural language interactions with simulation tools while preserving professional oversight and decision-making authority.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of geometry and operational parameters on the dehumidification performance of a desiccant coated heat exchanger

Solid desiccant dehumidification systems are an alternative to vapor-compression-based air dehumidification systems. They use solid desiccant materials to adsorb air moisture in space cooling. DCHE can integrate the cooling component in the heat exchanger to achieve higher dehumidification capacity. Comprehensive numeric modeling would be necessary to assist in the design and operation of the DCHE under development to achieve maximum performance. Here, we provide the details of a heat and mass transfer model developed for this purpose. The model aims to cover a gap in existing models by independently modeling heat transfer on the solid desiccant, fin, and tube. The model results were compared with an experimental reference for validation. The air outlet humidity and temperature results for dehumidification and regeneration showed a deviation lower than 15% from the experiment. The validated model was used to perform a parametric study for a series of design and operating conditions. The parametric analysis showed that an increase of 25% in desiccant layer thickness and thermal contact resistance between solid elements reduces moisture removal by 9.1% and 1%, respectively. These results indicate the need to independently model the desiccant layer.

42 ENGINEERING↗

Edge localized mode characteristics and divertor heat flux during stationary and transient phase for CFETR hybrid scenario

The study of edge localized mode (ELM) behavior, stationary heat flux and transient heat flux during the ELM crash phase is performed for a China Fusion Engineering Test Reactor (CFETR) 1 GW hybrid mode operation scenario ($R$ = 7.2 m, ${B_{\text{T}}}$ = 6.5 T, ${I_{\text{p}}}$ = 13.78 MA). Modeling and simulation start with a scenario obtained by multi-code integrated modeling on the one modeling framework for integrated tasks framework. Linear stability and nonlinear simulations of ELM dynamics are carried out using the BOUT++ six-field reduced magnetohydrodynamic module, which show a much smaller ELM energy loss (Δ ELM ~ 0.13%) compared to that of a Type-I ELM. Parametric analysis of the weak linear growth rate and small ELM energy loss characteristics shed light on physics corresponding to a grassy ELM regime for CFETR 1 GW hybrid scenario. The transient heat flux on the divertor target during this small ELM phase is investigated using BOUT++. Here we found that upstream radial transport in the scrape-off-layer (SOL) induced by small ELMs is weak, which keeps it in the drift-dominated region. However, the heat flux width is still broadened to ${\lambda _{\text{q}}}$ = 4.64 mm by the increase of separatrix temperature during ELM nonlinear evolution. The impact of transient peak heat load and ELM energy fluence on tungsten melting and net erosion rate of divertor target is evaluated for the first-time using physics-based transport that connects the pedestal with the SOL. Energy fluence caused by a single ELM pulse is below the tungsten melting limit, while tungsten erosion would exceed the material requirements. We conclude that external mitigation methods, such as divertor detachment and advanced divertor geometry are likely needed for the steady state operation of CFETR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced critical axial tensile strain limit of CORC ® wires: FEM and analytical modeling

Abstract Conductor on Round Core (CORC ® ) cables and wires are composed of spiraled high-temperature superconducting (HTS) rare-earth barium copper oxide (REBCO) tapes, wound in multiple layers, and can carry very high currents in background magnetic fields of more than 20 T. They combine isotropic flexibility and high resilience to electromagnetic and thermal loads. The brittle nature of HTS tapes limits the maximum allowable axial tensile strain in superconducting cables. An intrinsic tensile strain above about 0.45% will introduce cracks in the REBCO layer of straight HTS tapes resulting in irreversible damage. The helical fashion at which the REBCO tapes are wound around the central core allows tapes to experience only a fraction of the total axial tensile strain applied to the CORC ® wire. As a result, the critical strain limit of CORC ® wires can be increased by a factor of more than 10 that of REBCO tapes. Finite element (FE) and analytical models are developed to predict the performance of CORC ® wires under axial tensile strain. A parametric analysis is carried out by varying the winding angle, the Poisson’s ratio of the CORC ® wire core, the core diameter, and the tape width. The results show that a small variation in winding angle can have a significant impact on the cable’s axial tensile strain tolerance. While the radial contraction of the helically wound tapes in a CORC ® wire under axial tensile strain depends on its winding angle, it is mostly driven by the Poisson’s ratio of the central core, affecting the tape strain state and thus its performance. Contact pressure from multiple layers within the CORC ® wire also affects the CORC ® wire performance. The FE model can be used to optimize the cable design for specific application conditions, resulting in an irreversible strain limit of CORC ® cables and wires as high as 7%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Isotopic discrepancy in microscopic fusion of 16 O + 40,48 Ca

We present a detailed comparison of fusion in 16 O + 40,48 Ca within a fully microscopic time-dependent Hartree-Fock framework over sub-, near-, and above-barrier energies. While 16 O + 40 Ca fusion cross sections are reproduced within the available experimental energy range, calculations for the neutron-rich 16 O + 48 Ca system systematically overestimate the measured near-barrier cross sections. The discrepancy persists across the tested energy density functionals, indicating that it is not tied to a particular parametrization. Analysis of the dynamical interaction potentials reveals an outward shift and softening of the barrier region at the lowest collision energies. These results are then compared to a frozen density description where the barrier modifications are absent and the predicted cross sections are brought closer to experiment. Here, this demonstrates that the observed discrepancy is closely linked to dynamical surface rearrangement and isovector effects, and highlights the sensitivity of low-energy fusion to both the structure and dynamics of neutron-rich nuclei. This suggests that limitations in the isovector sector of conventional Skyrme EDFs in describing the structure of 48 Ca, as highlighted by CREX, are also manifested in the fusion dynamics of the 16 O + 48 Ca system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calculation of Nuclear Reactor Cooling Tower Performance With Limited Data Streams

Monitoring of cooling tower performance in a nuclear reactor facility is necessary to ensure safe operation; however, instrumentation for measuring performance characteristics can be difficult to install and may malfunction or break down over long duration experiments. This paper describes employing a thermodynamic approach to quantify cooling tower performance, the Merkel model, which requires only five parameters, namely, inlet water temperature, outlet water temperature, liquid mass flowrate, gas mass flowrate, and wet bulb temperature. Using this model, a general method to determine cooling tower operation for a nuclear reactor was developed in situations when neither the outlet water temperature nor gas mass flowrate are available, the former being a critical piece of information to bound the Merkel integral. Furthermore, when multiple cooling tower cells are used in parallel (as would be in the case of large-scale cooling operations), only the average outlet temperature of the cooling system is used as feedback for fan speed control, increasing the difficulty of obtaining the outlet water temperature for each cell. To address these shortcomings, this paper describes a method to obtain individual cell outlet water temperatures for mechanical forced-air cooling towers via parametric analysis and optimization. In this method, the outlet water temperature for an individual cooling tower cell is acquired as a function of the liquid-to-gas ratio (L/G). Leveraging the tight tolerance on the average outlet water temperature, an error function is generated to describe the deviation of the parameterized L/G to the highly controlled average outlet temperature. The method was able to determine the gas flowrate at rated conditions to be within 3.9% from that obtained from the manufacturer’s specification, while the average error for the four individual cooling cell outlet water temperatures were 1.6 °C, -0.5 °C, -1.0 °C, and 0.3 °C.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

URBANopt™ District Energy Systems HVAC Measures (DES_HVAC) [SWR-21-30]

DES_HVAC is a repository of a Parametric Analysis Tool (PAT) project and for scripts related to modeling of different HVAC systems for buildings in a district served by a district thermal energy system. The Measures directory contains the new measures developed to extract data from the simulations. Update these measures and not the measures in the Test Suite measures directory. PAT should be used to update the measures in the Test Suite project. The Test directory contains a PAT project for testing the functionality of the measures. The PAT project is named HVAC_Test and can be opened in PAT > 3.x.

Allen, Amy↗

OperonSEQer: A set of machine-learning algorithms with threshold voting for detection of operon pairs using short-read RNA-sequencing data

Operon prediction in prokaryotes is critical not only for understanding the regulation of endogenous gene expression, but also for exogenous targeting of genes using newly developed tools such as CRISPR-based gene modulation. A number of methods have used transcriptomics data to predict operons, based on the premise that contiguous genes in an operon will be expressed at similar levels. While promising results have been observed using these methods, most of them do not address uncertainty caused by technical variability between experiments, which is especially relevant when the amount of data available is small. In addition, many existing methods do not provide the flexibility to determine the stringency with which genes should be evaluated for being in an operon pair. We present OperonSEQer, a set of machine learning algorithms that uses the statistic and p-value from a non-parametric analysis of variance test (Kruskal-Wallis) to determine the likelihood that two adjacent genes are expressed from the same RNA molecule. We implement a voting system to allow users to choose the stringency of operon calls depending on whether your priority is high recall or high specificity. In addition, we provide the code so that users can retrain the algorithm and re-establish hyperparameters based on any data they choose, allowing for this method to be expanded as additional data is generated. We show that our approach detects operon pairs that are missed by current methods by comparing our predictions to publicly available long-read sequencing data. OperonSEQer therefore improves on existing methods in terms of accuracy, flexibility, and adaptability.

59 BASIC BIOLOGICAL SCIENCES↗

When Do Efficiency and Demand Flexibility Go Hand-in-hand?

Utilities have been experimenting with integrated demand side management (IDSM) programs since the 2000s. The potential benefits of improved program cost-effectiveness and customer engagement from combining energy efficiency (EE), demand flexibility (DF), and other distributed energy resources into an integrated customer offering have been recognized although there are several known regulatory and program administrative challenges. In addition, as buildings adopt EE measures, the baseline load profile change generally reduces the potential load that can be shed or shifted. This has been a significant technical barrier for customers and program implementers. However, it is a myth that EE always reduces DF. Load change from EE can be time-varying. Therefore, whether EE improves or reduces DF should be evaluated on an individual measure basis accounting for weather dependencies and interactions. For IDSM program design purpose, it is useful to understand how common EE features influence DF and the underlying building physics. In this paper, we use parametric simulations of a prototype medium office building to evaluate how various EE features influence DF, measured by a “demand decrease intensity” (W/ft2) metric. These EE features cover envelope characteristics, internal loads, and airside HVAC system. The parametric analysis shows that some efficient HVAC control measures will increase DF but not the traditional building envelope, lighting, and ventilation-related efficiency measures. These findings contribute to the technical basis for achieving enhanced energy benefits by packaging appropriate HVAC control measures in IDSM program design. Program developers should further validate these results in targeted pilot projects.

Yu, Lili↗

A Pilot-Scale Evaluation of Natural Gas-Based Foam at Elevated Pressure and Temperature Conditions

Abstract Nitrogen (N2) and Carbon Dioxide (CO2) foams have been used as hydraulic fracturing fluids for several decades to reduce water usage and minimize damage in water-sensitive reservoirs. These foam treatments require gases to be liquefied and transported to site. An alternative approach would be to use natural gas (NG) that is readily available from nearby wells, pipelines, and processing facilities as the internal, gaseous phase to create a NG-based foam. Hydraulic fracturing with NG foam is a relatively inexpensive option, makes use of an abundant and often wasted resource, and may even provide production benefits in certain reservoirs. As part of an ongoing development project sponsored by the Department of Energy (DOE), the surface process to create NG foam is being developed and the properties of NG foam are being explored. This paper presents recent results from a rigorous pilot-scale demonstration of NG foam over a range of operating scenarios relevant to surface and bottomhole conditions with a variety of base-fluid mixtures. The Pilot-scale Foam Test Facility (PFTF) used in these investigations is first described. The PFTF is capable of generating foamed fluids at pressures up to 7,500 psig and at temperatures in excess of 300°F. Then, results from several investigations aimed at proving NG foam at conditions relevant to the field are presented. NG foam was characterized using rheology measurements and flow visualization techniques. Experiments were performed to investigate the texture and stability of NG foam generated by two different mixing methods: one using a custom designed tee to match mixing velocities in the field where the gas phase is jetted into the aqueous stream, and another to ensure comprehensive mixing for laboratory analysis. Parametric studies were conducted to explore the effects of flow rate, foam quality, and temperature on the stability of NG foam. Moreover, different fluid preparations were used to investigate the effect of base fluid and additive concentrations on the stability of NG foams. Additional laboratory studies that investigated foam stability with produced water and multicomponent NG mixtures are also reported. The NG foams explored in these investigations exhibited typical, shear-thinning behavior observed in rheological studies of N2- and CO2-based foams. The measured viscosity and observed stability indicate that NG foams are well suited for fracturing applications. Like other foams, NG foam exhibits sensitivity to operating temperature characterized by a decrease in apparent viscosity as temperature increases. Rapid foam breakdown was observed at significantly elevated temperatures exceeding 290°F. In addition to fluid characterization, these investigations also yielded several key lessons that should be applied to future field demonstrations of NG foam.

Beck, Griffin↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Powdermet CRADA for VELOCITI Voucher (CRADA Final Report)

NLR shall develop a model of an electric thermal energy storage (ETES) system in the System Advisor Model (SAM) framework that uses a salt and particle slurry developed by PowderMet as the thermal energy storage medium. The ETES shall consist of a recuperated sCO 2 Brayton cycle using 2-tank indirect thermal energy storage and an electric heater for heat input. The salt slurry uses chloride salt and operates at a maximum temperature of 500-720°C. The ETES uses dry air cooling. The salt slurry will be modeled as a sensible heat storage medium and as a latent heat storage medium. NLR will use the model to do parametric analysis of the factors affecting the performance (ex., round trip efficiency) of the ETES system. NLR will work with PowderMet to estimate the costs of system components and total system costs, with the levelized cost of electricity (LCOE) as the primary cost metric.

14 SOLAR ENERGY↗

Study of hydrogen slush-hydrogen gel utilization

Study of hydrogen slush-hydrogen gel utilization is presented in two volume publication. The first volume contains the physical and thermal property data for hydrogen used in the study. In the second volume, details of the technical effort are presented including parametric analysis of effects on vehicle systems.

Keller, C. W.↗