Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “parameter studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Axion monodromy inflation with multi-natural modulations

We study parameter space in the axion monodromy inflation corrected by dynamically generated terms involving with the axion. The potential has the linear term with multiple sinusoidal functions, which play a role in generating modulations. We show that this potential leads both to a large tensor-to-scalar ratio r{sub T} ∼ 0.16 and to a large negative running of spectral index α{sub s} ∼ - (0.02 -0.03), ameliorating the tension between the result of the PLANCK and that of the BICEP2. To realize these results, a small hierarchy among dynamical scales is required whereas the decay constants in sinusoidal functions remain sub-Planckian in this model. We discuss also reheating process after the inflation in a bottom-up approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Unified superfluid dark sector

We present a novel theory of a unified dark sector, where late-time cosmic acceleration emerges from the dark matter superfluid framework. The system is described by a superfluid mixture consisting of two distinguishable states with a small energy gap, such as the ground state and an excited state of dark matter. Given their contact in the superfluid, interaction between those states can happen, converting one state into the other. This long range interaction within the superfluid couples the two superfluid phonon species through a cosine potential motivated by Josephson/Rabi interactions. As a consequence of this potential, a new dynamics of late-time accelerated expansion emerges in this system, without the need of dark energy, coming from a universe containing only this two-state DM superfluid. Because the superfluid species are non-relativistic, their sound speeds remain suitably small throughout the evolution. We calculate the expansion history and growth of linear perturbations, and compare the results to ΛCDM cosmology. For the fiducial parameters studied here, the predicted expansion and growth function are close to those of ΛCDM, but the difference in the predicted growth rate is significant at late times. The present theory nicely complements the recent proposal of dark matter superfluidity to explain the empirical success of MOdified Newtonian Dynamics (MOND) on galactic scales, thus offering a unified framework for dark matter, dark energy, and MOND phenomenology.

79 ASTRONOMY AND ASTROPHYSICS↗

Vacuum energy density measured from cosmological data

Within the ΛCDM cosmological model, the absolute value of Einstein's cosmological constant Λ, sometimes expressed as the gravitating mass-energy density ρΛ of the physical vacuum, is a fundamental constant of nature, whose accurate measurement plays a central role in testing some proposed theories of quantum gravity. Several combinations of currently public cosmological data and an assumed flat ΛCDM cosmological model are used here to make a joint Bayesian inference on the combination of conventional parameters Ω Λ h 2 that corresponds to the absolute physical density ρΛ. In physical units, we obtain ρ Λ = (60.3 ± 1.3)× 10 -31 g/cm 3 , the most accurate constraint to date, with an absolute calibration of cosmological measurements based on CMB temperature. Significantly different values are obtained with calibrations that use a local distance scale, mainly connected to systematic differences in the value of the Hubble constant. Furthermore, it is suggested that future comprehensive cosmological parameter studies assuming the ΛCDM model include constraints on the vacuum density.

79 ASTRONOMY AND ASTROPHYSICS↗

MAGNETIC BRAKING FORMULATION FOR SUN-LIKE STARS: DEPENDENCE ON DIPOLE FIELD STRENGTH AND ROTATION RATE

We use two-dimensional axisymmetric magnetohydrodynamic simulations to compute steady-state solutions for solar-like stellar winds from rotating stars with dipolar magnetic fields. Our parameter study includes 50 simulations covering a wide range of relative magnetic field strengths and rotation rates, extending from the slow- and approaching the fast-magnetic-rotator regimes. Using the simulations to compute the angular momentum loss, we derive a semi-analytic formulation for the external torque on the star that fits all of the simulations to a precision of a few percent. This formula provides a simple method for computing the magnetic braking of Sun-like stars due to magnetized stellar winds, which properly includes the dependence on the strength of the magnetic field, mass loss rate, stellar radius, surface gravity, and spin rate, and which is valid for both slow and fast rotators.

79 ASTRONOMY AND ASTROPHYSICS↗

Uncertainties in νp-process nucleosynthesis from Monte Carlo variation of reaction rates

ABSTRACT It has been suggested that a νp-process can occur when hot, dense, and proton-rich matter is expanding within a strong flux of antineutrinos. In such an environment, proton-rich nuclides can be produced in sequences of proton captures and (n, p) reactions, where the free neutrons are created in situ by $\overline{\nu }_\mathrm{e}+\mathrm{p} {\rightarrow} \mathrm{n}+\mathrm{e}^+$ reactions. The detailed hydrodynamic evolution determines where the nucleosynthesis path turns off from N = Z line and how far up the nuclear chart it runs. In this work, the uncertainties on the final isotopic abundances stemming from uncertainties in the nuclear reaction rates were investigated in a large-scale Monte Carlo approach, simultaneously varying more than 10 000 reactions. A large range of model conditions was investigated because a definitive astrophysical site for the νp-process has not yet been identified. The present parameter study provides, for each model, identification of the key nuclear reactions dominating the uncertainty for a given nuclide abundance. As all rates appearing in the νp-process involve unstable nuclei, and thus only theoretical rates are available, the final abundance uncertainties are larger than those for nucleosynthesis processes closer to stability. Nevertheless, most uncertainties remain below a factor of 3 in trajectories with robust nucleosynthesis. More extreme conditions allow production of heavier nuclides but show larger uncertainties because of the accumulation of the uncertainties in many rates and because the termination of nucleosynthesis is not at equilibrium conditions. It is also found that the solar ratio of the abundances of 92Mo and 94Mo could be reproduced within uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Respiratory triggered 4D cone-beam computed tomography: A novel method to reduce imaging dose

Purpose: A novel method called respiratory triggered 4D cone-beam computed tomography (RT 4D CBCT) is described whereby imaging dose can be reduced without degrading image quality. RT 4D CBCT utilizes a respiratory signal to trigger projections such that only a single projection is assigned to a given respiratory bin for each breathing cycle. In contrast, commercial 4D CBCT does not actively use the respiratory signal to minimize image dose. Methods: To compare RT 4D CBCT with conventional 4D CBCT, 3600 CBCT projections of a thorax phantom were gathered and reconstructed to generate a ground truth CBCT dataset. Simulation pairs of conventional 4D CBCT acquisitions and RT 4D CBCT acquisitions were developed assuming a sinusoidal respiratory signal which governs the selection of projections from the pool of 3600 original projections. The RT 4D CBCT acquisition triggers a single projection when the respiratory signal enters a desired acquisition bin; the conventional acquisition does not use a respiratory trigger and projections are acquired at a constant frequency. Acquisition parameters studied were breathing period, acquisition time, and imager frequency. The performance of RT 4D CBCT using phase based and displacement based sorting was also studied. Image quality was quantified by calculating difference images of the test dataset from the ground truth dataset. Imaging dose was calculated by counting projections. Results: Using phase based sorting RT 4D CBCT results in 47% less imaging dose on average compared to conventional 4D CBCT. Image quality differences were less than 4% at worst. Using displacement based sorting RT 4D CBCT results in 57% less imaging dose on average, than conventional 4D CBCT methods; however, image quality was 26% worse with RT 4D CBCT. Conclusions: Simulation studies have shown that RT 4D CBCT reduces imaging dose while maintaining comparable image quality for phase based 4D CBCT; image quality is degraded for displacement based RT 4D CBCT in its current implementation.

60 APPLIED LIFE SCIENCES↗

SU-E-I-85: Exploring the 18F-Fluorodeoxyglucose PET Characteristics in Staging of Esophageal Squamous Cell Carcinoma

Purpose: The aim of this study was to explore the characteristics derived from 18F-fluorodeoxyglucose (18F-FDG) PET image and assess its capacity in staging of esophageal squamous cell carcinoma (ESCC). Methods: 26 patients with newly diagnosed ESCC who underwent 18F-FDG PET scan were included in this study. Different image-derived indices including the standardized uptake value (SUV), gross tumor length, texture features and shape feature were considered. Taken the histopathologic examination as the gold standard, the extracted capacities of indices in staging of ESCC were assessed by Kruskal-Wallis test and Mann-Whitney test. Specificity and sensitivity for each of the studied parameters were derived using receiver-operating characteristic curves. Results: 18F-FDG SUVmax and SUVmean showed statistically significant capability in AJCC and TNM stages. Texture features such as ENT and CORR were significant factors for N stages(p=0.040, p=0.029). Both FDG PET Longitudinal length and shape feature Eccentricity (EC) (p≤0.010) provided powerful stratification in the primary ESCC AJCC and TNM stages than SUV and texture features. Receiver-operating-characteristic curve analysis showed that tumor textural analysis can capability M stages with higher sensitivity than SUV measurement but lower in T and N stages. Conclusion: The 18F-FDG image-derived characteristics of SUV, textural features and shape feature allow for good stratification AJCC and TNM stage in ESCC patients.

60 APPLIED LIFE SCIENCES↗

SU-E-T-372: Dosimetric Comparison of Craniospinal Irradiation Using Different Tomotherapy Techniques

Purpose: TomoHDA can treat with fixed jaws, dynamic jaws, and fixed gantry using either 3DCRT or IMRT. This study compares PTV coverage, OAR sparing, and beam-on-time (BOT) among these techniques for craniospinal irradiation (CSI). Methods: This study includes ten CSI patients treated to 23.4 Gy/13 fractions with Hi-Art 3.0 unit (HT-IMRT fixed 5 cm jaw). New plans were regenerated with 5 cm jaw for TomoHDA Hi-Art 5.0 using dynamic jaw (HD-IMRT), TomoDirect-IMRT (TD-IMRT), and Helical Tomotherapy 3DCRT (HT-3DCRT using 5 cm and 2.5 cm jaws with various pitches). Studied parameters include PTV mean dose, D95 (dose covering 95% of PTV), Paddick's conformity index (CI) and homogeneity index (HI – standard deviation of PTV dose/average PTV dose), BOT, and average OAR doses. Results: PTV coverage from these techniques were comparable (p>0.05). The main differences were in OAR sparing; HDIMRT reduced more OAR doses for lenses, bladder and rectum compared to HT-IMRT. For the sparing of visceral organs: liver, lung, heart, and kidneys, the three IMRT techniques gave comparable results. HD-IMRT gave best heart sparing; HT-IMRT best kidney sparing. Liver and lung doses were best reduced by TD-IMRT. All three IMRT techniques gave comparable BOT. OARs sparing was achieved for jaw size of 2.5 cm. HI was also improved but with doubling of BOT. Increasing the pitch number from 0.2 to 0.43 produced no significant improvement in OAR sparing but CI and HI did improve. Conclusion: HT-3DCRT, HT-IMRT, HD-IMRT or TD-IMRT techniques give comparable PTV coverage but the three IMRT plans better spared OARs compared with 3DCRT plans. Dynamic jaw plan is superior to fixed jaw plan to spare more OAR doses at field edge. TD-IMRT cannot reduce BOT for CSI patient but for sparing certain OAR, TD-IMRT may be used to avoid the beam going through the structures of interest.

60 APPLIED LIFE SCIENCES↗

Hyperons in neutron star matter within relativistic mean-field models

Since the discovery of neutron stars with masses around 2M{sub ⊙} the composition of matter in the central part of these massive stars has been intensively discussed. Within this paper we will (re)investigate the question of the appearance of hyperons. To that end we will perform parameter study within relativistic mean field models. We will show that it is possible to obtain high mass neutron stars with a substantial amount of hyperons and a spinodal instability at the onset of hyperons. The results depend strongly on the interaction in the hyperon-hyperon channels, on which only very little information is available from terrestrial experiments up to now.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electrochemical-mechanical coupling in composite planar structures that integrate flow channels and ion-conducting membranes

Ceramic oxygen-transport membranes, such as the doped perovskite La 0.6 Sr 0.4 Co 0.8 Fe 0.2 O 3-δ (LSCF6482) considered in the present paper, are effective in applications such as air separation. The present paper considers a planar configuration that is composed of a thin (order tens of microns) ion-transport membrane, a relatively thick (order millimeter) porous-ceramic support structure, and millimeter-scale oxygen-collection flow channels. The lattice-scale strain associated with charged defects (oxygen vacancies and small polarons) within ion-transport membranes causes macroscopic stress that could distort or damage the assembly. The modeling approach is based on an extended twodimensional Nernst–Planck–Poisson (NPP) formulation that is developed and applied to evaluate the effects of chemically induced stress within a planar oxygen-separation assembly. The computational model predicts two-dimensional distributions of steady-state defect concentrations, electrostatic potentials, and stress. Parameter studies consider the effects of support-membrane dimensions, materials mechanical properties, and operating conditions. Although the stress is found to have a negligible influence on the defect transport, the defect transport is found to significantly affect the stress distributions. Such results can play important roles in the design and development of planar ion-transport membranes and their support structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DAKOTA Design Analysis Kit for Optimization and Terascale

The DAKOTA (Design Analysis Kit for Optimization and Terascale Applications) toolkit provides a flexible and extensible interface between simulation codes (computational models) and iterative analysis methods. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the DAKOTA toolkit provides a flexible and extensible problem-solving environment for design and analysis of computational models on high performance computers.A user provides a set of DAKOTA commands in an input file and launches DAKOTA. DAKOTA invokes instances of the computational models, collects their results, and performs systems analyses. DAKOTA contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quantification with sampling, reliability, polynomial chaos, stochastic collocation, and epistemic methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as hybrid optimization, surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. Services for parallel computing, simulation interfacing, approximation modeling, fault tolerance, restart, and graphics are also included.

SciDAC↗

Management of tritium European Spallation Source

The European Spallation Source (ESS) will produce tritium via spallation and activation processes during operational activities. Within the location of ESS facility in Lund, Sweden site it is mandatory to demonstrate that the management strategy of the produced tritium ensures the compliance with the country regulation criteria. The aim of this paper is to give an overview of the different aspects of the tritium management in ESS facility. Besides the design parameter study of the helium coolant purification system of the target the consequences of the tritium releasing into the environment were also analyzed. Calculations show that the annual release of tritium during the normal operations represents a small fraction from the estimated total dose. However, more refined calculations of migration of activated-groundwater should be performed for higher hydraulic conductivities, with the availability of the results on soil examinations. With the assumption of 100% release of tritium to the atmosphere during the occurring of the extreme accidents, it was found as well that the total dose complies with the constraint. (authors)

43 PARTICLE ACCELERATORS↗

One dimensional temperature measurements by resonantly ionized photoemission thermometry of molecular nitrogen

This paper presents an extensive parameter study of a non-intrusive and non-seeded laser diagnostic method for measuring one dimensional (1D) rotational temperature of molecular nitrogen (N 2 ) at 165 - 450 K. Compared to previous efforts using molecular oxygen, here resonantly ionized and photoelectron induced fluorescence of molecular nitrogen for thermometry (N 2 RIPT) was demonstrated. The RIPT signal is generated by directly probing various rotational levels within the rovibrational absorption band of N 2 , corresponding to the 3-photon transition of N 2 ( X 1 Σ g + , v =0→ b 1 Π u , v ′ =6) near 285 nm, without involving collisional effects of molecular oxygen and nitrogen. The photoionized N 2 produces strong first negative band of N 2 + ( B 2 Σ u + − X 2 Σ g + ) near 390 nm, 420 nm, and 425 nm. Boltzmann analyses of various discrete fluorescence emission lines yield rotational temperatures of molecular nitrogen. By empirically choosing multiple rotational levels within the absorption band, non-scanning thermometry can be accurately achieved for molecular nitrogen. It is demonstrated that the N 2 RIPT technique can measure 1D temperature profile up to ∼5 cm in length within a pure N 2 environment. Multiple wavelengths are thoroughly analyzed and listed that are accurate for RIPT for various temperature ranges.

McCord, Walker (ORCID:0000000179747550)↗

On the 3D printability of one-part moisture-curable polyurethanes via direct ink writing (DIW)

Direct ink writing (DIW) is an ambient temperature additive manufacturing (AM) method that accommodates many possible ink materials. Here, in this work, we demonstrate using a moisture-curable commercially available polyurethane (PU) sealant as an alternative ink for DIW. We discussed the fundamentals of PU chemistry and determined the best 3D printing parameters. Studies on rheological, thermogravimetric, spectroscopic characterization, and initial finite element analyses (FEA) showed properties expected from a performance sealant with high elongation and low modulus of a 3D-printed object. This affirms the flexibility of the DIW technique as an accessible AM method amenable for future materials development from commercial model formulations.

36 MATERIALS SCIENCE↗

Beam formation in the alternative JLEIC ion complex

The proposed alternative design approach for the JLab-EIC (JLEIC) ion complex uses a more compact linac and pre-booster, and consolidates the electron storage ring (ering) as a large booster for the ions. Following a parameter study showing the feasibility of this design approach, we have adapted the e-ring lattice by adding RF sections to accelerate ion beams. In this study, we focus on the transverse beam formation for protons and lead ions from the ion source to collision point including the linac, pre-booster, e-ring and collider ring. Effects such as stripping injection, space charge, intra-beam scattering and beam cooling determine the total charge accumulated in each ring and the final luminosity of the collider.

Mustapha, Brahim↗

Enhancing the CDF's B physics program with a faster data acquisition system.

The physics program of Run II at the Tevatron includes precision electroweak measurements such as the determination of the top quark and W boson masses; bottom and charm physics including the determination of the B{sub s} and D{sup 0} mixing parameters; studies of the strong interaction; and searches for the Higgs particle, supersymmetric particles, hidden space-time dimensions and quark substructure. All of these measurements benefit from a high-resolution tracking detector. Most of them rely heavily on the efficient identification of heavy flavored B hadrons by detection of displaced secondary vertices, and are enhanced by the capability to trigger on tracks not coming from the primary vertex. This is uniquely provided by CDF's finely-segmented silicon detectors surrounding the interaction region. Thus CDF experiment's physics potential critically depends on the performance of its silicon detectors. The CDF silicon detectors were designed to operate up to 2-3 fb{sup -1} of accumulated pji collisions, with an upgrade planned thereafter. However, the upgrade project was canceled in 2003 and Run II has been extended through 2011, with an expected total delivered integrated luminosity of 12 fb{sup -1} or more. Several preventive measures were taken to keep the original detector operational and maintain its performance. The most important of these are the decrease in the operating temperature of the detector, which reduces the impact of radiation exposure, and measures to minimize damage due to integrated radiation dose, thermal cycles, and wire bond resonance conditions. Despite these measures the detectors operating conditions continue to change with issues arising from radiation damage to the sensors, aging infrastructure and electronics. These, together with the basic challenges posed by the inaccessibility of the detector volume and large number (about 750 thousand) of readout channels, make the silicon detector operations the single most complex and high priority job in the CDF experiment.

43 PARTICLE ACCELERATORS↗

Analysis of Femtosecond Timing Noise and Stability in Microwave Components

To probe chemical dynamics, X-ray pump-probe experiments trigger a change in a sample with an optical laser pulse, followed by an X-ray probe. At the Linac Coherent Light Source, LCLS, timing differences between the optical pulse and x-ray probe have been observed with an accuracy as low as 50 femtoseconds. This sets a lower bound on the number of frames one can arrange over a time scale to recreate a 'movie' of the chemical reaction. The timing system is based on phase measurements from signals corresponding to the two laser pulses; these measurements are done by using a double-balanced mixer for detection. To increase the accuracy of the system, this paper studies parameters affecting phase detection systems based on mixers, such as signal input power, noise levels, temperature drift, and the effect these parameters have on components such as the mixers, splitters, amplifiers, and phase shifters. Noise data taken with a spectrum analyzer show that splitters based on ferrite cores perform with less noise than strip-line splitters. The data also shows that noise in specific mixers does not correspond with the changes in sensitivity per input power level. Temperature drift is seen to exist on a scale between 1 and 27 fs/{sup o}C for all of the components tested. Results show that any components using more metallic conductor tend to exhibit more noise as well as more temperature drift. The scale of these effects is large enough that specific care should be given when choosing components and designing the housing of high precision microwave mixing systems for use in detection systems such as the LCLS. With these improvements, the timing accuracy can be improved to lower than currently possible.

43 PARTICLE ACCELERATORS↗