Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outliers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

DeBoinR: Density Boxplots in R

DeBoinR (Density Boxplots in R) takes in a set of Probability Density Functions (PDFs), calculates outliers based on several notions of distance, and visualizes these outliers via functional boxplots. This code is written as a stand-along R package with the hopes of eventually submitting it to CRAN. The package is written in generality; it would be useful to any researching looking to analyze a general ensemble of PDFs.

Murph, Alexander↗

DISSIDE: Dynamic In Silico Sample Identification for Discrete Evaluation

DISSIDE uses novel unsupervised learning to select samples that best represent the strongest a priori discrete pattern in a given data set. It further removes major outliers and "noisy" samples that do not fit discrete patterns well or represent outliers in groups below a defined n value. It then estimates the fit and strength of the a priori discrete pattern using both unconstrained and constrained methods for raw and cleaned data

LeBrun, Erick↗

Assessing Prior Emergent Constraints on Surface Albedo Feedback in CMIP6

An emergent constraint (EC) is a popular model evaluation technique, which offers the potential to reduce intermodel variability in projections of climate change. Two examples have previously been laid out for future surface albedo feedbacks (SAF) stemming from loss of Northern Hemisphere (NH) snow cover (SAF snow ) and sea ice (SAF ice ). These processes also have a modern-day analog that occurs each year as snow and sea ice retreat from their seasonal maxima, which is strongly correlated with future SAF across an ensemble of climate models. The newly released CMIP6 ensemble offers the chance to test prior constraints through out-of-sample verification, an important examination of EC robustness. Here, we show that the SAF snow EC is equally strong in CMIP6 as it was in past generations, while the SAF ice EC is also shown to exist in CMIP6, but with different, slightly weaker characteristics. We find that the CMIP6 mean NH SAF exhibits a global feedback of 0.25 ± 0.05 W m -2 K -1 , or ~61% of the total global albedo feedback, largely in line with prior generations despite its increased climate sensitivity. Additionally, the NH SAF can be broken down into similar contributions from snow and sea ice over the twenty-first century in CMIP6. Crucially, intermodel variability in seasonal SAF snow and SAF ice is largely unchanged from CMIP5 because of poor outlier simulations of snow cover, surface albedo, and sea ice thickness. These outliers act to mask the noted improvement from many models when it comes to SAF ice , and to a lesser extent SAF snow .

58 GEOSCIENCES↗

Data from TropiRoot 1.0 database: tropical root characteristics across environments

TropiRoot 1.0 is a new tropical root database with root characteristics across environment gradients. It has data extracted from 104 new sources, resulting in more than 8000 rows of data (either species or community data). Most of the data in TropiRoot 1.0 includes root characteristics such as root biomass, morphology, root dynamics, mass fraction, architecture, anatomy, physiology and root chemistry. This initiative represents an approximately 30% increase in the currently available data for tropical roots in the Fine Root Ecology Database (FRED). TropiRoot 1.0, contains root characteristics from 25 different countries where seven are located in Asia, six in South America, five in Central America and the Caribbean, four in Africa, two in North America, and 1 in Oceania. Due to the volume of data, when ancillary data was available, including soil data, these data was either extracted and included in the database or their availability was recorded in an additional column. Multiple contributors checked the entries for outliers during the collation process to ensure data quality. For text-based observations, we examined all cells to ensure that their content relates to their specific categories. For numerical observations, we ordered each numerical value from least to greatest and plotted the values, checking apparent outliers against the data in their respective sources and correcting or removing incorrect or impossible values. Some data (soil and aboveground) have different columns for the same variable presented in different units, including originally published units, but root characteristics data had units converted to match the ones reported in FRED. By filling a gap from global databases, TropiRoot 1.0 expands our knowledge of otherwise so far underrepresented regions, and our ability to assess global trends. This advancement can be used to improve tropical forest representation in vegetation models.

54 ENVIRONMENTAL SCIENCES↗

COMPASS-FME Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) Experiment Level 2 Sensor Data v2-1

This is the version v2-1 Level 2 (L2) data release for COMPASS-FME environmental sensors located at our Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experimental site. This manipulative, ecosystem-scale TEMPEST experiment addresses the potential for freshwater and estuarine-water disturbance events to alter tree function, species composition, and ecosystem processes in a deciduous coastal forest in MD, USA. The experiment uses a large-unit (2000 m2), un-replicated experimental design, with three 50 m × 40 m plots serving as control, freshwater, and estuarine-water treatments. Level 2 (L2) data consist of sensor observations from the COMPASS-FME synoptic sites, TEMPEST, and DELUGE. Compared to the L1 data, these are more consistent (always 15-minute timestamps for the entire year); better QA/QC’d (out of bounds, out of service, and extreme outlier values are removed); and more complete, with a gap-filled time series available alongside the main observations, and additional derived (calculated) variables. L2 data are intended to be rapidly and easily usable in analyses and simulations. However, algorithmic outlier identification always carries the risk of removing valid data, and Level 1 data may be more suitable for analyses that focus on variability or extreme events. This dataset includes: - An overall dataset README file that describes the current version, gives citation and contact information, etc. - Site- and year-specific folders, each holding variable-specific Parquet (a high performance, space efficient format; see https://parquet.apache.org) data files for each site and plot in that year. - Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, detailed flood times, as well as a general description of the site. - Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are reported every 15 minutes. Please see v2-1 TEMPEST L2 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning. Data files are in Apache Parquet, a high performance, space efficient format for tabular data. These files can be read using R's `arrow` package (https://arrow.apache.org/docs/r/), with similar tools available in other languages. The TEMPEST flood events occurred on the following dates. They lasted for ~10 hours each day and delivered ~80,000 gallons to each plot; many data streams are available at 1 or 5 minute frequency during these periods. * Tests: Aug 25 (fresh plot) and Sep 9 (salt plot), 2021 * TEMPEST 1: June 22, 2022 * TEMPEST 2: June 6-7, 2023 * TEMPEST 3: June 11-13, 2024

EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC TEMPERATU↗

COMPASS-FME Synoptic Sites Level 2 Sensor Data v2-1

This is the version 2-1 Level 2 (L2) data release for COMPASS-FME environmental sensors located at our synoptic field sites. COMPASS-FME is studying sites in two distinct regions, the Chesapeake Bay and the Western Lake Erie Basin. We established the network at seven "synoptic" (observational) sites along the Chesapeake Bay and Lake Erie coastlines, collectively generating over three million observations per month, to track and comprehend environmental changes where land and water intersect. Additionally, the two regions provide an interesting contrast of saltwater and freshwater coasts that allow us to differentiate the impacts of inundation and coastal water chemistries in two nationally important coastal systems. Level 2 (L2) data consist of sensor observations from the COMPASS-FME synoptic sites, TEMPEST, and DELUGE. Compared to the L1 data, these are more consistent (always 15-minute timestamps for the entire year); better QA/QC’d (out of bounds, out of service, and extreme outlier values are removed); and more complete, with a gap-filled time series available alongside the main observations, and additional derived (calculated) variables. L2 data are intended to be rapidly and easily usable in analyses and simulations. However, algorithmic outlier identification always carries the risk of removing valid data, and Level 1 data may be more suitable for analyses that focus on variability or extreme events. This dataset includes: - An overall dataset README file that describes the current version, gives citation and contact information, etc. - Site- and year-specific folders, each holding variable-specific Parquet (a high performance, space efficient format; see https://parquet.apache.org) data files for each site and plot in that year. - Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, detailed flood times, as well as a general description of the site. - Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are reported every 15 minutes. Data files are in Apache Parquet, a high performance, space efficient format for tabular data. These files can be read using R's `arrow` package (https://arrow.apache.org/docs/r/), with similar tools available in other languages. Please see v2-1 L2 Sensor Package QStart.pdf for detailed information on data package structure, temporal coverage, and versioning.

EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC TEMPERATU↗

Method for automatic correction of offset drift in online sensors

Abstract Successful operation and optimization of water treatment systems hinge on the availability of high-quality online sensor measurements. Ideally, the available measurements should be simultaneously accurate (i.e., unbiased and precise), representative, voluminous, and timely. This remains a pain-point in current water infrastructures, forming a barrier to a wider adoption of advanced and autonomous control systems. While short-lived symptoms, such as outliers and spikes, can be detected or corrected with state-of-the-art tools for fault detection and identification, it is much more difficult to detect, diagnose, and correct the symptoms of slow faults, such as changes in offset or sensitivity due to drift. The time scale of drift is often longer than the time scales of the system dynamics of interest. Moreover, sensor drift has been shown to occur at the same time and with similar rates when sensors are exposed to the same conditions. This challenges data quality management strategies based on redundancy. In this contribution, we develop a new method, including both a hands-off sensor calibration mechanism and an information-seeking control architecture that can handle the unique challenge of simultaneous and similar drift in online sensors.

Chowdhury, Dhrubajit↗

OVIS 3.2 user's guide.

This document describes how to obtain, install, use, and enjoy a better life with OVIS version 3.2. The OVIS project targets scalable, real-time analysis of very large data sets. We characterize the behaviors of elements and aggregations of elements (e.g., across space and time) in data sets in order to detect meaningful conditions and anomalous behaviors. We are particularly interested in determining anomalous behaviors that can be used as advance indicators of significant events of which notification can be made or upon which action can be taken or invoked. The OVIS open source tool (BSD license) is available for download at ovis.ca.sandia.gov. While we intend for it to support a variety of application domains, the OVIS tool was initially developed for, and continues to be primarily tuned for, the investigation of High Performance Compute (HPC) cluster system health. In this application it is intended to be both a system administrator tool for monitoring and a system engineer tool for exploring the system state in depth. OVIS 3.2 provides a variety of statistical tools for examining the behavior of elements in a cluster (e.g., nodes, racks) and associated resources (e.g., storage appliances and network switches). It provides an interactive 3-D physical view in which the cluster elements can be colored by raw or derived element values (e.g., temperatures, memory errors). The visual display allows the user to easily determine abnormal or outlier behaviors. Additionally, it provides search capabilities for certain scheduler logs. The OVIS capabilities were designed to be highly interactive - for example, the job search may drive an analysis which in turn may drive the user generation of a derived value which would then be examined on the physical display. The OVIS project envisions the capabilities of its tools applied to compute cluster monitoring. In the future, integration with the scheduler or resource manager will be included in a release to enable intelligent resource utilization. For example, nodes that are deemed less healthy (i.e., nodes that exhibit outlier behavior with respect to some set of variables shown to be correlated with future failure) can be discovered and assigned to shorter duration or less important jobs. Further, HPC applications with fault-tolerant capabilities would respond to changes in resource health and other OVIS notifications as needed, rather than undertaking preventative measures (e.g. checkpointing) at regular intervals unnecessarily.

97 MATHEMATICS AND COMPUTING↗

DARHT Multi-intelligence Seismic and Acoustic Data Analysis

The purpose of this report is to document the analysis of seismic and acoustic data collected at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility at Los Alamos National Laboratory for robust, multi-intelligence decision making. The data utilized herein is obtained from two tri-axial seismic sensors and three acoustic sensors, resulting in a total of nine data channels. The goal of this analysis is to develop a generalized, automated framework to determine internal operations at DARHT using informative features extracted from measurements collected external of the facility. Our framework involves four components: (1) feature extraction, (2) data fusion, (3) classification, and finally (4) robustness analysis. Two approaches are taken for extracting features from the data. The first of these, generic feature extraction, involves extraction of statistical features from the nine data channels. The second approach, event detection, identifies specific events relevant to traffic entering and leaving the facility as well as explosive activities at DARHT and nearby explosive testing sites. Event detection is completed using a two stage method, first utilizing signatures in the frequency domain to identify outliers and second extracting short duration events of interest among these outliers by evaluating residuals of an autoregressive exogenous time series model. Features extracted from each data set are then fused to perform analysis with a multi-intelligence paradigm, where information from multiple data sets are combined to generate more information than available through analysis of each independently. The fused feature set is used to train a statistical classifier and predict the state of operations to inform a decision maker. We demonstrate this classification using both generic statistical features and event detection and provide a comparison of the two methods. Finally, the concept of decision robustness is presented through a preliminary analysis where uncertainty is added to the system through noise in the measurements.

58 GEOSCIENCES↗

TBASS: A Robust Adaptation of Bayesian Adaptive Spline Surfaces

The R package TBASS is an extension of the BASS package created by Francom and Sansó (2019). The package is used to fit a Bayesian multivariate adaptive spline to a dataset that either follows a Student’s t-distribution or has outliers. Much of the framework for TBASS is adapted from the concepts of Bayesian Multivariate Adaptive Regression Splines (BMARS), specifically the work done by Denison, Mallick, and Smith (1998). The spline function is fit using a Reversible-Jump Markov Chain Monte Carlo algorithm,. By including this more robust generalization, a dataset with outliers can be accurately fit using the BMARS model, without the possibility of overfitting or variance inflation.

97 MATHEMATICS AND COMPUTING↗

Performance Comparison of Circular and Spherical Error Probable Estimators

This report compares the performance of three Circular Error Probable (CEP) estimators: the Grubbs-Patnaik estimator, a new, non-iterative, radial-integration estimator, and a median estimator. It also compares the performance of two Spherical Error Probable (SEP) estimators. The performance of each estimator is assessed in terms of bias, uncertainty, robustness, and computational complexity. Robustness is evaluated with respect to outliers, variations in the underlying statistical distribution characterizing munition impact positions, and impact-position measurement errors. The performance assessments indicate the radial-integration and Grubbs-Patnaik estimators perform nearly identically providing the statistical distribution of impact-position coordinates is jointly normal with zero means. In that case, both estimators outperform the median estimator by about 2% relative to the true CEP in terms of estimator uncertainty. The bias performance of the radial-integration and median estimators is close to zero for jointly normal impacts, however, the Grubbs-Patnaik estimator can be significantly biased for jointly normal impacts with non-zero means. When the statistical distribution characterizing impact positions is known, but not jointly normal, the radial-integration estimator is superior. In this case, the median estimator also outperforms the Grubbs-Patnaik estimator but is not quite as good as the radial-integration estimator. If the statistical distribution characterizing impacts is unknown and not jointly normal, or if distribution parameters are difficult or impractical to estimate, or if test data is corrupted with outliers, then the median estimator dramatically outperforms the other estimators, especially in terms of estimation bias. Unexpectedly, measurement noise did not significantly degrade the performance of any of the estimators, except for cases with signal to noise ratios less than five. Although the Grubbs-Patnaik estimator has remained the gold standard for CEP estimation for over half a century, the performance assessments indicate the new, non-iterative, radial-integration estimator and the median estimator offer significant advantages and, in most practical real-world conditions, are superior estimators. These estimators are also useful for SEP estimation whereas the Grubbs-Patnaik estimator does not extend to three dimensions.

97 MATHEMATICS AND COMPUTING↗

Prediction of External Corrosion for Steel Cylinders--2007 Report

Depleted uranium hexafluoride (DUF{sub 6}) is stored in over 62,000 containment cylinders at the Paducah Gaseous Diffusion Plant (PGDP) in Paducah, Kentucky, and at the Portsmouth Gaseous Diffusion Plant (PORTS) in Portsmouth, Ohio. Over 4,800 of the cylinders at Portsmouth were recently moved there from the East Tennessee Technology Park (ETTP) in Oak Ridge, Tennessee. The cylinders range in age up to 56 years and come in various models, but most are 48-inch diameter 'thin-wall'(312.5 mil) and 'thick-wall' (625 mil) cylinders and 30-inch diameter '30A' (including '30B') cylinders with 1/2-inch (500 mil) walls. Most of the cylinders are carbon steel, and they are subject to corrosion. The United States Department of Energy (DOE) manages the cylinders to maintain them and the DUF{sub 6} they contain. Cylinder management requirements are specified in the System Requirements Document (LMES 1997a), and the activities to fulfill them are specified in the System Engineering Management Plan (LMES 1997b). This report documents activities that address DUF{sub 6} cylinder management requirements involving measuring and forecasting cylinder wall thicknesses. As part of these activities, ultrasonic thickness (UT) measurements are made on samples of cylinders. For each sampled cylinder, multiple measurements are made in an attempt to find, approximately, the minimum wall thickness. Some cylinders have a skirt, which is an extension of the cylinder wall to protect the head (end) and valve. The head/skirt interface crevice is thought to be particularly vulnerable to corrosion, and for some skirted cylinders, in addition to the main body UT measurements, a separate suite of measurements is also made at the head/skirt interface. The main-body and head/skirt minimum thickness data are used to fit models relating minimum thickness to cylinder age, nominal thicknesses, and cylinder functional groups defined in terms of plant site, storage yard, top or bottom row storage positions, etc. These models are then used to compute projections of numbers of cylinders expected to fail various minimum wall thickness criteria. The minimum wall thickness criteria are as follows. For thin-wall cylinders: 0 (breach), 62.5, and 250 mils. For thick-wall cylinders: 0, 62.5, and 500 mils. For 30A cylinders: 0, 62.5, and 100 mils. Each of these criteria triplets are based respectively on (1) loss of DUF{sub 6} (breaching), (2) safe handling and stacking operations, and (3) ANSI N14.1 standards for off-site transport and contents transfer. This report complements and extends previous editions of the cylinder corrosion report by Lyon (1995, 1996, 1997, 1998, 2000), by Schmoyer and Lyon (2001, 2002, 2003), and by Schmoyer (2004). These reports are based on UT data collected in FY03 and before. In this report UT data collected after FY03 but before FY07 is combined with the earlier data, and all of the UT data is inventoried chronologically and by the various functional groups. The UT data is then used to fit models of maximum pit depth and minimum wall thickness, statistical outliers are investigated, and the fitted models are used to extrapolate minimum thickness estimates into the future and in turn to compute projections of numbers of cylinders expected to fail various thickness criteria. A model evaluation is performed comparing UT measurements made after FY05 with model-fitted projections based only on data collected in FY05 and before. As in previous reports, the projections depend on the treatment of outliers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analyst Tools and Quality Control Software for the ARM Data System

Mission Research develops analyst tools and automated quality control software in order to assist the Atmospheric Radiation Measurement (ARM) Data Quality Office with their data inspection tasks. We have developed web-based data analysis and visualization tools such as the interactive plotting program NCVweb, various diagnostic plot browsers, and a datastream processing status application. These tools allow even novice ARM researchers to be productive with ARM data with only minimal effort. We also contribute to the ARM Data Quality Office by analyzing ARM data streams, developing new quality control metrics, new diagnostic plots, and integrating this information into DQ HandS - the Data Quality Health and Status web-based explorer. We have developed several ways to detect outliers in ARM data streams and have written software to run in an automated fashion to flag these outliers. We have also embarked on a system to comprehensively generate long time-series plots, frequency distributions, and other relevant statistics for scientific and engineering data in most high-level, publicly available ARM data streams. Furthermore, frequency distributions categorized by month or by season are made available to help define valid data ranges specific to those time domains. These statistics can be used to set limits that when checked, will improve upon the reporting of suspicious data and the early detection of instrument malfunction. The statistics and proposed limits are stored in a database for easy reporting, refining, and for use by other processes. Web-based applications to view the results are also available.

54 ENVIRONMENTAL SCIENCES↗

INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING CHARACTERIZATION FACILITY (WSCF)

Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-846 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (S&GRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a 'blind' sample to the laboratory. Feedback from the S&GRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 2008a). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated-carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more effectively remove inorganic chloride from the activated carbon adsorption tubes. With the TOX sample preparation equipment and TOX analyzers at WSCF, the nitrate wash recommended by EPA SW-846 method 9020B was found to be inadequate to remove inorganic chloride interference. Increasing the nitrate wash concentration from 10 grams per liter (g/L) to 100 g/L potassium nitrate and increasing the nitrate wash volume from 3 milliliters (mL) to 10 mL effectively removed the inorganic chloride up to at least 100 ppm chloride in the sample matrix. Excessive purging of the adsorption tubes during sample preparation was eliminated. These changes in sample preparation have been incorporated in the analytical procedure. The results using the revised sample preparation procedure show better agreement of TOX values both for replicate analyses of single samples and for the analysis of replicate samples acquired from the same groundwater well. Furthermore, less apparent column breakthrough now occurs with the revised procedure. One additional modification made to sample preparation was to discontinue the treatment of groundwater samples with sodium bisulfite. Sodium bisulfite is used to remove inorganic chlorine from the sample; inorganic chlorine is not expected to be a constituent in these groundwater samples. Several other factors were also investigated as possible sources of anomalous TOX results: (1) Instrument instability: examination of the history of results for TOX laboratory control samples and initial calibration verification standards indicate good long-term precision for the method and instrument. Determination of a method detection limit of 2.3 ppb in a deionized water matrix indicates the method and instrumentation have good stability and repeatability. (2) Non-linear instrument response: the instrument is shown to have good linear response from zero to 200 parts per billion (ppb) TOX. This concentration range encompasses the majority of samples received at WSCF for TOX analysis. (3) Improper sample preservation: ion-chromatographic analysis of several samples with anomalous TOX results revealed that the samples were properly preserved with sulfuric acid and not hydrochloric acid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING AND CHARACTERIZATION FACILITY

Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-S46 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (SGRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a ''blind'' sample to the laboratory. Feedback from the SGRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 200Sa). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more effectively remove inorganic chloride from the activated-carbon adsorption tubes. With the TOX sample preparation equipment and TOX analyzers at WSCF, the nitrate wash recommended by EPA SW-846 method 9020B was found to be inadequate to remove inorganic chloride interference. Increasing the nitrate wash concentration from 10 grams per liter (g/L) to 100 giL potassium nitrate and increasing the nitrate wash volume from 3 milliliters (mL) to 10 mL effectively removed the inorganic chloride up to at least 100 ppm chloride in the sample matrix. Excessive purging of the adsorption tubes during sample preparation was eliminated. These changes in sample preparation have been incorporated in the analytical procedure. The results using the revised sample preparation procedure show better agreement of TOX values both for replicate analyses of single samples and for the analysis of replicate samples acquired from the same groundwater well. Furthermore, less apparent adsorption tube breakthrough now occurs with the revised procedure. One additional modification made to sample preparation was to discontinue the treatment of groundwater samples with sodium bisulfite. Sodium bisulfite is used to remove inorganic chlorine from the sample; inorganic chlorine is not expected to be a constituent in these groundwater samples. Several other factors were also investigated as possible sources of anomalous TOX results: (1) Instrument instability: examination of the history of results for TOX laboratory control samples and initial calibration verification standards indicate good long-term precision for the method and instrument. Determination of a method detection limit of 2.3 ppb in a deionized water matrix indicates the method and instrumentation have good stability and repeatability. (2) Non-linear instrument response: the instrument is shown to have good linear response from zero to 200 parts per billion (ppb) TOX. This concentration range encompasses the majority of samples received at WSCF for TOX analysis. Linear response was checked using both non-volatile TOX species (trichlorophenol) and volatile TOX species. Average recoveries of the volatile TOX species ranged between 50% and 75%. (3) Improper sample preservation: ion-chromatographic analysis of several samples with anomalous TOX results revealed that the samples were properly preserved with sulfuric acid and not hydrochloric acid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Economic impacts of a hypothetical H1N1 pandemic : a cross-sectional analysis.

A NISAC study on the economic effects of a hypothetical H1N1 pandemic was done in order to assess the differential impacts at the state and industry levels given changes in absenteeism, mortality, and consumer spending rates. Part of the analysis was to determine if there were any direct relationships between pandemic impacts and gross domestic product (GDP) losses. Multiple regression analysis was used because it shows very clearly which predictors are significant in their impact on GDP. GDP impact data taken from the REMI PI+ (Regional Economic Models, Inc., Policy Insight +) model was used to serve as the response variable. NISAC economists selected the average absenteeism rate, mortality rate, and consumer spending categories as the predictor variables. Two outliers were found in the data: Nevada and Washington, DC. The analysis was done twice, with the outliers removed for the second analysis. The second set of regressions yielded a cleaner model, but for the purposes of this study, the analysts deemed it not as useful because particular interest was placed on determining the differential impacts to states. Hospitals and accommodation were found to be the most important predictors of percentage change in GDP among the consumer spending variables.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pattern Mining and Anomaly Detection based on the Power System Synchrophasor Measurements

Real-time monitoring of power system dynamics using phasor measurement units (PMUs) data improves situational awareness and system reliability and potentially can help prevent blackouts due to early anomaly detection. The study presented in the paper is based on the actual PMU measurements of the U.S. western interconnection system. Given the nonlinear and nonstationary PMUs data, we developed a robust anomaly detection framework. Wavelet-based multi-resolution analysis, combined with moving-window-based outlier detection and anomaly scoring, were deployed to identify potential PMU events. The candidate events were evaluated using spatiotemporal correlation analysis, and then classified for a better understanding of the event types. The results demonstrated successful anomaly detection and classification, compared with the recorded real-world events.

Ren, Huiying↗

Computer-Vision-Based Vibration Tracking Using a Digital Camera: A Sparse-Optical-Flow-Based Target Tracking Method

Computer-vision-based target tracking is a technology applied to a wide range of research areas, including structural vibration monitoring. However, current target tracking methods suffer from noise in digital image processing. In this paper, a new target tracking method based on the sparse optical flow technique is introduced for improving the accuracy in tracking the target, especially when the target has a large displacement. The proposed method utilizes the Oriented FAST and Rotated BRIEF (ORB) technique which is based on FAST (Features from Accelerated Segment Test), a feature detector, and BRIEF (Binary Robust Independent Elementary Features), a binary descriptor. ORB maintains a variety of keypoints and combines the multi-level strategy with an optical flow algorithm to search the keypoints with a large motion vector for tracking. Then, an outlier removal method based on Hamming distance and interquartile range (IQR) score is introduced to minimize the error. The proposed target tracking method is verified through a lab experiment—a three-story shear building structure subjected to various harmonic excitations. It is compared with existing sparse-optical-flow-based target tracking methods and target tracking methods based on three other types of techniques, i.e., feature matching, dense optical flow, and template matching. The results show that the performance of target tracking is greatly improved through the use of a multi-level strategy and the proposed outlier removal method. The proposed sparse-optical-flow-based target tracking method achieves the best accuracy compared to other existing target tracking methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗