Some applications of the gas laser as a source of light for the testing of optical systems.
Lateral shearing interferometer with gas-laser light source for testing large optical systems
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Lateral shearing interferometer with gas-laser light source for testing large optical systems
Modified Al-dielectric-Al Fabry-Perot interference filter for isolating Hg 1849 angstrom emission line from Hg 2536 angstrom line
Compact unit operates much faster than conventional piezoelectric scanners. High voltage creates electric field in Pockels cell, changing refractive properties. Cell changes optical path length between mirrors without mechanically moving anything in gap. High voltage varied rapidly to scan interferometer. Voltage applied longitudinally or transversely, depending on type of Pockels cell. New electro-optic scanner scans given range in one-millionth time of piezoelectric scanner - tens to hundreds of nanoseconds per interferometer order. Also reducing size of interferometer.
The James Webb Space Telescope (JWST) Optical Telescope Element (OTE) and Integrated Science Instrument Module (ISIM) completed element level integration and test programs and were integrated to the next level of assembly called OTE/ISIM (OTIS) at Goddard Space Flight Center (GSFC) in Greenbelt, Maryland in 2016. Before shipping the OTIS to Johnson Space Center (JSC) for optical test at cryogenic temperature a series of vibration and acoustic tests were performed. To help ensure that the OTIS was ready to be shipped to JSC an optical center of curvature (CoC) test was performed to measure changes in the mirror's optical performance to verify that the telescope's primary mirror was not adversely impacted by the environmental testing and help us in understanding potential anomalies identified during the JSC tests. The primary is a 6.5 meter diameter mirror consisting of 18 individual hexagonal segments. Each segment is an off-axis asphere. There are a total of three prescriptions repeated six times each. As part of the CoC test each segment was individually measured using a high-speed interferometer (HSI) designed and built specifically for this test. This interferometer is capable of characterizing both static and dynamic characteristics of the mirrors. The latter capability was used, with the aid of a vibration stinger applying a low-level input force, to measure the dynamic characteristic changes of the PM backplane structure. This paper describes the CoC test setup and both static and dynamic test results.
An electronic optical laser interferometer capable of resolving depth differences of as low as 30 A and planar displacements of 6000 A was constructed to examine surface profiles of bearing surfaces without physical contact. Topological chemical reactivity was determined by applying a drop of dilute alcoholic hydrochloric acid and measuring the profile of the solid surface before and after application of this probe. Scuffed bearing surfaces reacted much faster than virgin ones but that bearing surfaces exposed to lubricants containing an organic chloride reacted much more slowly. The reactivity of stainless steel plates, heated in a nitrogen atmosphere to different temperatures, were examined later at ambient temperature. The change of surface contour as a result of the probe reaction followed Arrhenius-type relation with respect to heat treatment temperature. The contact area of the plate of a ball/plate sliding elastohydrodynamic contact run on trimethylopropane triheptanoate with or without additives was optically profiled periodically. As scuffing was approached, the change of profile within the contact region changed much more rapidly by the acid probe and assumed a constant high value after scuffing. A nonetching metallurgical phase was found in the scuff mark, which was apparently responsible for the high reactivity.
In this paper we will describe recent advances in the development of optical systems for future space infrared telescope and interferometer applications which will operate at very low or cryogenic temperatures (T less then or equal to 77K) with emphasis on beryllium and silicon carbide optics.
Stepping method permits higher amplitude modulation of secondary mirror of Fourier interferometer. Amplitude of mirror motion is limited only by available voltage drive on error-correcting actuator. Closed-loop controller provides servo error voltage linearly proportional to offset from proper null position. Bidirectional counter serves to count number of reference laser fringes offset from null position.
A dichromated gelatin off-axis Fresnel zone plate was designed, fabricated, and used in a new type of interferometer for optical metrology. This single hologram optical element combines the functions of a beam splitter, beam diverger, and aberrated null lens. Data presented show the successful application for an interferometric test of an f/6, 200-mm diam parabolic mirror.
An electronic optical laser interferometer capable of resolving depth differences of as low as 30 A and planar displacements of 6000 A was constructed for the examination of surface profiles of bearing surfaces without physical contact. This instrument was used to determine topological chemical reactivity by applying a drop of dilute alcoholic hydrochloric acid and measuring the profile of the solid surface before and after application of this probe. It was found that scuffed bearing surfaces reacted much faster than virgin ones but that bearing surfaces exposed to lubricants containing an organic chloride reacted much more slowly. In a separate series of experiments, a number of stainless steel plates were heated in a nitrogen atmosphere to different temperatures and their reactivity examined later at ambient temperature. The change of surface contour as a result of the probe reaction was found to follow an Arrhenius-type relation with respect to heat treatment temperature. This result could have implications on the scuffing mechanism.
Remote displacement measurement is demonstrated using a Fabry-Perot cavity with a multimode optical fiber link. The sensing cavity modulates, as a function of its length, the spectrum of a light-emitting diode (LED). The light returns via the fiber and is analyzed by a tunable reference cavity. A closed-loop control causes the reference cavity to track the sensing cavity length within 2 x 10 to the -12th m. Displacement range is 2 x 10 to the -6th m. The reference cavity length is measured interferometrically, using a laser, to obtain the sensing cavity length. Advantages of this sensing technique include compatibility with multimode fiber-optic components, high immunity to optical losses, and large dynamic range.
The conference presents papers on the history of the search for extraterrestrial life, the scientific rationale and methods used in the search for other planetary systems, the detection of distant planets with the Space Telescope, planetary searches using optical astrometric interferometers, and infrared spectral identification of complex organic molecules in interstellar grains. Also considered are universal protein ancestors from hydrogen cyanide and water, astronomical sources of polarized light and their role in determining molecular chirality on earth, the universal diagrams and life in the universe, the precambrian evolution of terrestrial life and a thermodynamic approach to the occurrance and appearance of galactic life forms. Papers are also presented on the Ohio Seti program, lunar reflections of terrestrial radio leakage, the multichannel spectrum analyzer, software implementation of detection algorithms for the MCSA, the Serendip II design, galactic colonization and competition in a young galactic disk, implications of ancient and future migrations, extraterrestrial intelligence, the ineviability and the possible structures of supercivilizations, planetary, interplanetary and interstellar organic matter, and universal aspects of biological evolution.
The acousto-ultrasonic method has proven to be a most interesting technique for nondestructive evaluation of the mechanical properties of a variety of materials. Use of the technique or a modification thereof, has led to correlation of the associated stress wave factor with mechanical properties of both metals and composite materials. The method is applied to the nondestructive evaluation of selected fiber reinforced structural composites. For the first time, conventional piezoelectric transducers were replaced with laser beam ultrasonic generators and detectors. This modification permitted true non-contact acousto-ultrasonic measurements to be made, which yielded new information about the basic mechanisms involved as well as proved the feasibility of making such non-contact measurements on terrestrial and space structures and heat engine components. A state-of-the-art laser based acousto-ultrasonic system, incorporating a compact pulsed laser and a fiber-optic heterodyne interferometer, was delivered to the NASA Lewis Research Center.
A new spectrometer design is presented in which the angular dispersion with respect to wave number is nearly constant. The spectrometer is a type of grism, a series combination of grating and prism, in which the constant parts of the dispersion terms add to one another but the slopes of the dispersions tend to cancel one another. A systematic method is presented for optimizing the grating and prism parameters. A cross-dispersion technique is presented, eliminating overlapping grating orders. A design example is given for the visible region from 0.45 to 0.80 micron with essentially constant wave-number dispersion and a peak transmission of approximately 95 percent. This grism is well suited for measuring channeled spectra as generated by an optical stellar interferometer.
A compact, portable fiber-optic heterodyne interferometer designed to detect out-of-plane motion on surfaces is described. The interferometer provides a linear output for displacements over a broad frequency range and can be used for ultrasonic, acoustic emission, and acousto-ultrasonic (AU) testing. The interferometer in conjunction with a compact pulsed Nd:YAG laser represents a noncontact testing system. This system was tested to determine its usefulness for the AU technique. The results obtained show that replacement of conventional piezoelectric transducers (PZT) with a laser generation/detection system make it possible to carry out noncontact AU measurements. The waveforms recorded were 5 MHZ PZT-generated ultrasound propagating through an aluminum block, detection of the acoustic emission event, and laser AU waveforms from graphite-epoxy laminates and a filament-wound composite.
POINTS is a space-based optical astrometric interferometer capable of measuring the angular separation of two stars about 90 degrees apart with 5-microarcsec nominal accuracy . During the intended ten-year mission, a repeated survey of a few hundred targets over the whole sky, including a few bright quasars, establish a 'rigid' reference grid with 0.5 microarcsec position uncertainties. At that level, the grid is free of regional biases and tied to the extra-Galactic frame that is the present best candidate for an inertial frame. POINTS will also determine parallaxes and annual proper motions at about the same level. Further, the planetary ephemeris frame is tied through stellar aberration to the grid at about 300 microarcsec. Additional targets of interest, to a limiting magnitude of greater than 20, are observed relative to the grid, yielding determinations with uncertainties depending on the observing schedule. Measurement at the microarcsec/year level of the apparent relative velocities of quasars that are widely separated on the sky severely test the assumption of cosmological quasar distances and may also constrain models of the early universe.
The Space Interferometry Mission is an optical stellar interferometer with a 10 meter baseline capable of micro-arcsecond accuracy astrometry.
Explore the source record for details and available documents.
Explore the source record for details and available documents.