Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “occupancy modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Full-Scale Crash Test of an MD-500 Helicopter

A full-scale crash test was successfully conducted in March 2010 of an MD-500 helicopter at NASA Langley Research Center s Landing and Impact Research Facility. The reasons for conducting this test were threefold: 1 To generate data to be used with finite element computer modeling efforts, 2 To study the crashworthiness features typically associated with a small representative helicopter, and 3 To compare aircraft response to data collected from a previously conducted MD-500 crash test, which included an externally deployable energy absorbing (DEA) concept. Instrumentation on the airframe included accelerometers on various structural components of the airframe; and strain gages on keel beams, skid gear and portions of the skin. Three Anthropomorphic Test Devices and a specialized Human Surrogate Torso Model were also onboard to collect occupant loads for evaluation with common injury risk criteria. This paper presents background and results from this crash test conducted without the DEA concept. These results showed accelerations of approximately 30 to 50 g on the airframe at various locations, little energy attenuation through the airframe, and moderate to high probability of occupant injury for a variety of injury criteria.

Littell, Justin↗

Passenger Aggregation Network with Very Efficient Listing (PANVEL) Ridesharing Model for Urban Air Mobility

This paper introduces a ridesharing model useful for examining the role of ridesharing in advancing Urban Air Mobility (UAM) operations. Although the success of UAM will likely require a host of new technologies in aircraft design, airspace management, autonomy, and more, operational innovations like ridesharing may also be key, especially to lower operating costs and attract a broader market. The ridesharing algorithm introduced, termed the Passenger Aggregation Network with Very Efficient Listing (PANVEL) model, estimates trip numbers and passenger occupancy aboard particular aircraft within a UAM network in a metropolitan area. This algorithm is applied within a transportation computational framework to determine the impact of ridesharing on mode choice, passenger travel patterns, and transportation costs. The algorithm aggregates passengers traveling between identical origin-destination pairs, factoring in individual-specific metrics, such as value of time and alternative mode options, to generate high load factors on UAM aircraft. The computational framework simulates passenger mode-choice selections using an effective-cost approach to determine the number of ridesharing UAM-preferred trips, and results with ridesharing are representative of a rough upper bound on UAM ridership potential for a given metro area. A case study in the Cleveland metro area is presented to demonstrate the algorithm and assess ridesharing potential.

advanced air mobility↗

Passenger Aggregation Network with Very Efficient Listing (PANVEL) Ridesharing Model for Urban Air Mobility

This presentation introduces a ridesharing model useful for examining the role of ridesharing in advancing Urban Air Mobility (UAM) operations. Although the success of UAM will likely require a host of new technologies in aircraft design, airspace management, autonomy, and more, operational innovations like ridesharing may also be key, especially to lower operating costs and attract a broader market. The ridesharing algorithm introduced, termed the Passenger Aggregation Network with Very Efficient Listing (PANVEL) model, estimates trip numbers and passenger occupancy aboard particular aircraft within a UAM network in a metropolitan area. This algorithm is applied within a transportation computational framework to determine the impact of ridesharing on mode choice, passenger travel patterns, and transportation costs. The algorithm aggregates passengers traveling between identical origin-destination pairs, factoring in individual-specific metrics, such as value of time and alternative mode options, to generate high load factors on UAM aircraft. The computational framework simulates passenger mode-choice selections using an effective-cost approach to determine the number of ridesharing UAM-preferred trips, and results with ridesharing are representative of a rough upper bound on UAM ridership potential for a given metro area. A case study in the Cleveland metro area is presented to demonstrate the algorithm and assess ridesharing potential.

advanced air mobility↗

The 3D clustering of Lyman Alpha Emitters measured with DESI

We present a clustering analysis of Lyman-$α$ emitters (LAEs) using spectroscopic observations from the Dark Energy Spectroscopic Instrument (DESI) of candidates selected from the Blanco/DECam Intermediate-Band Imaging Survey (IBIS). We measure the two-point correlation function and the power spectrum, including cross-correlations with DESI quasars. Using both analytical and halo occupation distribution (HOD) simulation-based modeling, we find a linear bias of $b \sim 2.31$--$2.62$ for LAEs over the redshift range $2.26 < z < 3.41$. The analytical modeling also provides constraints on the strength of radiative transfer effects, while the HOD analysis characterizes the LAE-halo connection across multiple models. Finally, we quantify the magnitude of non-perturbative clustering effects such as Fingers of God in the LAE population, providing essential input for the accurate modeling of LAE-based cosmological analyses in forthcoming high-redshift surveys such as DESI-II.

Ebina, H. [UC, Berkeley; LBL, Berkeley] (ORCID:000↗

Measurement of the $\textit{B}(\textit{E}2 ↑)$ strengths of 36 Ca and 38 Ca

In this work, the $B(E2, 0^+_1 → 2^+_1)$ strengths of 36 Ca and 38 Ca are measured to be 131(20) $e^2\text{fm}^4$ and 101(11) $e^2\text{fm}^4$, respectively. The $\textit{B}(\textit{E}2)$ value for 36 Ca required a measurement of the p/γ branching ratio because the 2 + state is proton unbound. This branching ratio is $B_p$=0.087(8). These $\textit{B}(\textit{E}2)$ and branching-ratio values can be reproduced in the shell-model with the ZMB2 interaction, an interaction that predicts the $\textit{Z} = 20 \textit{sd}$-shell closure is incomplete with large proton pf-shell occupancies in the ground state. These occupancies are at odds with other shell-model and energy-density-functional calculations of 36 Ca. New data are used to provide an update on constraints of the density dependence of the symmetry energy through mirror charge-radii differences as well as to help reduce uncertainties of the astrophysical important 35 K(p,γ) reaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multimodal sensor fusion framework for residential building occupancy detection

For several years now, smart building energy systems have been a research area of intensive activity. In light of the increasing need for sustainable buildings and energy systems, this trend motivates an increasing need for a solution to reduce carbon dioxide emissions and improve energy efficiency. This work proposes a high-performing and transferable occupancy detection framework that combines sensor data from different data modalities, including time series environmental data (temperature, humidity, and illuminance), image data, and acoustic energy data using ensemble method. To draw out the best prediction performance in each modality, the proposed framework was developed, including various models that were designed to learn the occupancy patterns reflected in the physical data streams. To tackle the time series environmental data, we designed two variants of an occupancy detection spatiotemporal pattern network (Occ-STPN) that performs both feature level and decision level fusion, respectively. We also propose a new metric; the fading memory mean square error (FMMSE), that provides a fair evaluation and penalization of delayed occupancy predictions. Multiple open-sourced datasets, including the Electricity Consumption and Occupancy and the University of California, Irvine's (UCI) building occupancy detection dataset, along with our own real data collected from six different houses, were used to validate the algorithms' performance. The experimental results presented herein break down the performance for each sensing modality, and a detailed analysis of the performance is also discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Generating traffic-based building occupancy schedules in Chattanooga, Tennessee from a grid of traffic sensors

Building occupancy significantly impacts energy use, timing for demand impacts, and is a significant source of uncertainty in building energy models. There are relatively few sources that define building occupancy schedules and number of occupants per building or space type. More importantly, these sources define traditional schedules that are likely not to reflect the true occupancy of a given building. We construct traffic-based occupancy schedules which are more responsive to changes in mobility patterns, and which can realistically estimate occupant arrivals, departures, and counts in individual buildings.

Berres, Andy↗

Hierarchical Model-Free Transactive Control of Building Loads to Support Grid Services

Residential buildings consume 4.4 quads of electricity annually, approximately 37% of the total electricity consumption in the United States. This represents a vast resource that can be used for demand management and other ancillary services. This project aims to develop a robust, scalable hierarchical transactional control mechanism incorporating elements of model-free control (MFC) and game theory to harness buildings to provide ancillary services to the grid. This approach is being taken to address the challenges of incorporating traditional transactional control schemes into existing buildings. The challenges include small individual building sizes requiring aggregation of many buildings, unpredictable energy usage that makes model identification difficult, and satisfying the sensitive occupant comfort constraints. In the proposed approach, by separating the control mechanism into two layers above and below the load aggregator, MFC can be used below the aggregator to modulate flexible building loads in response to pricing signals with guaranteed performance. This allows the burden of identifying an accurate model of the system to be shifted to the above-aggregator layer, where fluctuations in individual building usage have less impact on predicted building system behavior. Game theory concepts can then be used to determine pricing curves and control signals among regional aggregators. Managing this control in a game-theoretic approach will allow us to build in financial incentives that increase customer engagement. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable on small, embedded devices. In a broader sense, developing a strategy capable of effectively incorporating residential and small commercial buildings will allow greater throughput of existing and emerging grid services in addition to future transactive energy grid management methods. Using MFC within a hierarchical control architecture will allow the shifting of existing forecasting challenges to an aggregate level, where dynamics are slower and more predictable. This will enable a smooth interface between the grid services requests of utilities and the reliable control required by participating buildings. MFC, which supports distributed control architecture, permits a scalable solution that can be deployed to neighborhood-size systems as well as individual buildings. This project focuses on three objectives: (1) developing the mathematical framework, algorithm toolkit, and software toolset of the two-layer transactive control testbed; (2) developing a scalable solution for application over many residential and small-size commercial buildings with sparse distributed communication; and (3) field testing and implementation on hardware of the control strategies developed in the previous two objectives. The research and development activities are focused and designed to be impactful within the relevant 2025 targets timeframe. An open-source control framework for exploiting variability and dispatchability of building loads will be delivered as the outcome of the project. This capability enables greater participation of loads in electricity markets and ancillary services that are both useful for the utility and financially beneficial for building owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Determination of Site Occupancy in the M–Pd–Zn (M = Cu, Ag, and Au) γ-Brass Phase by CALculation of PHAse Diagrams Modeling and Rietveld Refinement

The Pd–Zn γ-brass phase provides exciting opportunities for synthesizing site-isolated catalysts with precisely controlled Pd active site ensembles. Introducing a third metallic element into the γ-brass lattice further perturbs the catalytic active site ensembles. Here, in this work, we introduce coinage metallic elements M (M = Cu, Ag, and Au) into the Pd–Zn γ-brass phase and investigate the site occupation factors of each element in the γ-brass lattice. The CALculation of PHAse Diagrams (CALPHAD) modeling approach supported by energetics predicted by the density functional theory and X-ray and neutron diffraction with Rietveld refinement were used to identify the SOF on each Wyckoff site for various M amounts alloyed into the Pd–Zn γ-brass phase. The present analysis unveils the strong preference for Pd occupying the outer tetrahedral (OT) site in the γ-brass lattice, while the coinage metallic elements tend to substitute for Zn on the octahedral (OH) site. The determination of site occupancy in the bulk M–Pd–Zn γ-brass phase provides opportunities to investigate and tailor potential catalytically active site ensembles in the γ-brass phase materials.

36 MATERIALS SCIENCE↗

A Coupled Probabilistic Wake Vortex and Aircraft Response Prediction Model

Wake vortex spacing standards along with weather and runway occupancy time, restrict terminal area throughput and impose major constraints on the overall capacity and efficiency of the National Airspace System (NAS). For more than two decades, the National Aeronautics and Space Administration (NASA) has been conducting research on characterizing wake vortex behavior in order to develop fast-time wake transport and decay prediction models. It is expected that the models can be used in the systems level design of advanced air traffic management (ATM) concepts that safely increase the capacity of the NAS. It is also envisioned that at a later stage of maturity, these models could potentially be used operationally, in groundbased spacing and scheduling systems as well as on the flight deck.

Gloudemans, Thijs↗

Galaxy assembly bias and large-scale distribution: a comparison between IllustrisTNG and a semi-analytic model

In this work, we compare large scale structure observables for stellar mass selected samples at z = 0, as predicted by two galaxy models, the hydrodynamical simulation IllustrisTNG and the Santa-Cruz semi-analytic model (SC-SAM). Although both models have been independently calibrated to match observations, rather than each other, we find good agreement between the two models for two-point clustering and galaxy assembly bias signatures. The models also show a qualitatively similar response of occupancy and clustering to secondary halo parameters other than mass, such as formation history and concentration, although with some quantitative differences. Thus, our results demonstrate that the galaxy–halo relationships in SC-SAM and TNG are quite similar to first order. However, we also find areas in which the models differ. For example, we note a strong correlation between halo gas content and environment in TNG, which is lacking in the SC-SAM, as well as differences in the occupancy predictions for low-mass haloes. Moreover, we show that higher order statistics, such as cumulants of the density field, help us to accurately describe the galaxy distribution and discriminate between models that show degenerate behaviour for two-point statistics. Our results suggest that SAMs are a promising cost-effective and intuitive method for generating mock catalogues for next generation cosmological surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of Impact Energy Attenuators and Composite Material Designs of a UAM VTOL Concept Vehicle

The development of Vertical Take-off and Landing (VTOL) vehicles for the Urban Air Mobility (UAM) markets presents a need for light weight vehicle structures with effective occupant protection capabilities. The National Aeronautics and Space Administration (NASA) has been working to fill that need, recently developing a cadre of concept vehicles to help characterize UAM design feasibility. This paper describes a study, using these concept vehicles, to evaluate the use of advanced composite structure and energy attenuating designs in the UAM vehicle design space. A finite element model (FEM) of a single passenger quadrotor concept vehicle was developed in LS-Dyna® and simulated under nominal and off-nominal vertical impact conditions. A variety of energy attenuating design mechanisms were implemented within this model to quantify their effectiveness in improving occupant safety. The use of carbon composites in both the energy attenuation mechanisms and vehicle structure was evaluated. The results of this study found significant reduction in occupant injury risk with the implementation of energy absorbing composite crush tubes and landing gear within the vehicle design. Additionally the use of a carbon fiber as a structural material was found to provide significant weight reduction while maintaining similar occupant loads to that predicted with an aluminum structure. This work provides a preliminary evaluation of design mechanisms and materials that may be used to optimize occupant protection capabilities within the UAM market.

Putnam, Jacob↗

HVAC control fine-grained occupancy pattern estimation

A thermal state of a plurality of zones of the building is updated according to a building thermal model and information received from temperature sensors of the building. Predicted occupant counts for an upcoming plurality of time slots for each of the plurality of zones are updated using actual occupancy counts for each of the plurality of zones. A misprediction type distribution for the upcoming plurality of time slots for each of the plurality of zones is updated, the misprediction type distribution indicating misprediction for true negatives, false positives, false negatives, and true positives. A total misprediction cost expectation is updated according to the predicted occupant counts and the misprediction type distribution. HVAC power for each of the plurality of zones is determined to optimize occupant thermal comfort weighted according to the predicted occupant counts while minimizing the total misprediction cost expectation. HVAC operation is controlled per the HVAC power.

Lin, Shan↗

Occupational safety considerations with hydrazine fuels

A simple pharmacokinetic model and a specially designed dermal vapor exposure chamber which provides respiratory protection were used to determine the rate of penetration of hydrazine and 1,1-dimethylhydrazine (UDMH) vapor through the skin of rats. Parameters for the pharmacokinetic model were determined from intravenous and inhalation exposure data. The model was then used to estimate the skin permeation coefficient for hydrazine or UDMH vapor from the dermal-vapor exposure data. This analysis indicates that UDMH vapor has a relatively high permeability through skin (0.7 cm/hr), a value somewhat higher than was obtained for hydrazine by the same procedure (0.09 cm/hr). Based on these skin permeability results, a skin-only vapor exposure limit giving protection equivalent to the inhalation Threshold Limit Value (TLV) could be calculated. The current TLV's for UDMH and hydrazine are 0.5 and 0.1 ppm, respectively. The corresponding skin-only TLV equivalents, for personnel wearing respiratory protection, are 32 ppm for UDMH and 48 ppm for hydrazine. Should the proposed lowering to the TLV's for these compounds to 0.01 ppm be adopted, the equivalent skin-only TLV's would become 0.64 ppm for UDMH and 4.8 for hydrazine.

Clewell, H. J.↗

An Open-Source Framework for Characterizing Urban Energy Models: Integrating Top-Down and Bottom-Up Methods to Predict Residential Buildings Characteristics: Preprint

Bottom-up urban energy models are crucial for understanding current energy use patterns and informing design strategies. However, accurately characterizing these models to represent different communities remains a challenge due to the extensive data needed for simulating existing energy use behavior. This data includes information related to human activities and building characteristics, all of which correlate with socioeconomic factors. To overcome this challenge, we developed an automated framework that utilizes both top-down and bottom-up data, to predict unknown building and occupant characteristics that are needed for more accurate and equitable modeling and analytics. Our framework, integrated into the URBANopt district energy modeling platform, uses statistical data models from ResStock. URBANopt models co-located buildings and neighborhoods. At this scale there are data gaps in building characteristic data, such as materials, insulation, occupancy, income, and energy usage of the buildings. To address this data gap, we use ResStock data, representative at the census tract scale, and develop machine-learning and deeplearning techniques to disaggregate it to individual buildings. By mapping unique occupant, building and economic properties to URBANopt energy models, we gain detailed insights into the variability of building energy use across different neighborhoods. This insight helps deploy technologies for co-located buildings and supports targeted upgrades for communities with unique economic and demographic characteristics, ensuring energy equity. Accurate characterization of energy models allows us to develop equitable strategies tailored to diverse neighborhoods, whether underserved or affluent. Our automated framework streamlines energy modeling and provides a reliable tool for building energy characterization.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

NMF-Based Anomaly Detection in CMS 2D Tracking Occupancy Histograms

The CMS experiment relies on Data Quality Monitoring (DQM) to ensure that recorded collision data are suitable for physics analysis. During LHC Run 3, each run contains many lumisections and tracking monitoring elements, making offline inspection challenging, especially for localized detector effects that may appear only for short periods of time. This poster presents an unsupervised machine-learning approach to identify anomalous lumisections in CMS tracking occupancy histograms using Non-Negative Matrix Factorization (NMF). The workflow uses offline CMS DQMIO tracking histograms retrieved with the CMS DIALS API and organized as two-dimensional occupancy maps for each lumisection. After selecting stable lumisections, the occupancy maps are normalized and arranged into a non-negative data matrix. The NMF model learns a compact set of basis patterns describing normal tracking occupancy. Each lumisection is then reconstructed from these learned components, and the reconstruction error is used as an anomaly score. Large residuals indicate occupancy patterns that deviate from normal detector behavior and are flagged for further inspection. This NMF-based approach provides a fast and interpretable way to flag lumisections whose tracking occupancy patterns differ from normal detector behavior. Preliminary studies show sensitivity to known tracking anomalies, and ongoing work is focused on validating the method across additional Run 3 Pixel and Strip detector issues.

Rodríguez Ramos, Iliomar [Puerto Rico U., Mayaguez↗

Machine learning-enhanced hybrid modeling approach for better identification of a building thermal network model and improved prediction

The gray-box modeling approach, which uses a semi-physical thermal network model, has been widely used in building prediction applications, such as model predictive control (MPC). However, unmeasured disturbances, such as occupants, lighting, and in/exfiltration loads, make it challenging to apply this approach to practical buildings. In this word, we propose a hybrid modeling approach that integrates the gray-box model with a model for unmeasured disturbance. After reviewing several system identification approaches, we systematically designed the unmeasured disturbance model with a model selection process based on statistical tests to make it robust. We generated data based on the building model calibrated by real operational data and then trained the hybrid model for two different weather conditions. The hybrid model approach demonstrates an RMSE reduction of approximately 0.2–0.9 °C and 0.3–2 °C on 1-day ahead temperature prediction compared to the Conventional approach for mild (Berkeley, CA) and cold (Chicago, IL) climates, respectively. In addition, this approach was applied to experimental data obtained from the laboratory building to be used for the MPC application, showing superior prediction performances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wattile: Probabilistic Deep Learning-based Forecasting of Building Energy Consumption [SWR-20-94]

Accurate energy forecasting is becoming critical due to many reasons: i ) optimal distributed energy resources operations and dispatch, ii) fault detection and diagnostics, and iii) meeting operational energy efficiency targets. Wattile uses deep learning (DL) for the building's short-term load forecasting application. Two specific types of neural networks called, Long Short Term Memory (LSTM) and Sequence-to-Sequence (S2S) models are used to make predictions. Forecasting models are trained using online historical weather and occupancy indicator data streams from the Intelligent Campus Program's data acquisition systems at the National Renewable Energy Laboratory (NREL) for main meters and sub-meters of multiple building types. These models use probabilistic methods to provide quantile-based forecasts in addition to nominal conditional median predictions of electricity consumption.

Frank, Stephen↗