Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “monochromators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A survey of quality measures for gray-scale image compression

Although a variety of techniques are available today for gray-scale image compression, a complete evaluation of these techniques cannot be made as there is no single reliable objective criterion for measuring the error in compressed images. The traditional subjective criteria are burdensome, and usually inaccurate or inconsistent. On the other hand, being the most common objective criterion, the mean square error (MSE) does not have a good correlation with the viewer's response. It is now understood that in order to have a reliable quality measure, a representative model of the complex human visual system is required. In this paper, we survey and give a classification of the criteria for the evaluation of monochrome image quality.

Eskicioglu, Ahmet M.↗

Functional test and calibration plan for the Lightning Imaging Sensor

The Lightning Imaging Sensor (LIS) wide field-of-view solid-state camera can measure the global distribution of lightning from LEO, through the use of a narrowband interference filter to detect the neutral O band at 777.4 nm. Prelaunch testing and calibration of the LIS has required three separate laboratory systems; absolute radiometric calibration of the sensor will be furnished over the whole spectral range by a high resolution monochromator and motorized gimbals.

Bergstrom, James W.↗

The SSABLE system - Automated archive, catalog, browse and distribution of satellite data in near-real time

Historically, locating and browsing satellite data has been a cumbersome and expensive process. This has impeded the efficient and effective use of satellite data in the geosciences. SSABLE is a new interactive tool for the archive, browse, order, and distribution of satellite date based upon X Window, high bandwidth networks, and digital image rendering techniques. SSABLE provides for automatically constructing relational database queries to archived image datasets based on time, data, geographical location, and other selection criteria. SSABLE also provides a visual representation of the selected archived data for viewing on the user's X terminal. SSABLE is a near real-time system; for example, data are added to SSABLE's database within 10 min after capture. SSABLE is network and machine independent; it will run identically on any machine which satisfies the following three requirements: 1) has a bitmapped display (monochrome or greater); 2) is running the X Window system; and 3) is on a network directly reachable by the SSABLE system. SSABLE has been evaluated at over 100 international sites. Network response time in the United States and Canada varies between 4 and 7 s for browse image updates; reported transmission times to Europe and Australia typically are 20-25 s.

Simpson, James J.↗

Absorption coefficients for water vapor at 193 nm from 300 to 1073 K

Measurements of the water absorption coefficient at 193 nm from 300 to 1073 K are reported. The measurements were made using broadband VUV radiation and a monochromator-based detection system. The water vapor was generated by a saturator and metered into a flowing, 99 cm absorption cell via a water vapor mass flow meter. The 193 nm absorption coefficient measurements are compared to room temperature and high temperature shock tube measurements with good agreement. The absorption can be parameterized by a nu3 vibrational mode reaction coordinate and the thermal population of the nu3 mode.

Kessler, W. J.↗

In-simulator assessment of trade-offs arising from mixture of color cuing and monocular, binoptic, and stereopsis cuing information

The use of monochrome Helmet Mounted Display (HMD) systems is becoming prevalent in today's complex flight mission environment. These HMD systems can provide stereopsis cueing as an almost natural byproduct for binocular helmet systems of an additional image generation source is provided. The addition of color cueing capability is much more difficult. The application of stereopsis cueing to advanced HMD and heads-down flight display concepts has demonstrated gains in pilot situation awareness and improved task performance. To provide stereopsis, binocular HMD systems must trade some of the total field-of-view (FOV) available from their two monocular fields to obtain a partial overlap region. The visual field then provides a mixture of cues, with monocular regions on both peripheries, and, in the overlapped center, a binoptic (the same image to both eyes) or, if lateral disparity is introduced to produce two images, a stereo region. The goal of this research was to assess the trade-offs arising from the mixture of color cueing and monocular, biocular, and stereopsis cueing information in peripheral monitoring displays as encountered in HMD systems. The accompanying effect of stereopsis cueing in the foveal display of tracking information was also assessed.

Williams, Steven P.↗

Fiber Optic Switch For Broadband Emission Spectroscopy

Many high-temperature processes comprise large-scale phenomena. Studying spatial and temporal correlations of physical processes between several locations within characteristic scales provides desired information on macroscopic physical processes. Achieved with emission spectroscopy by use of multiple optical fibers. Simultaneous coupling of light from these fibers into single available spectrometer and/or monochromator not accomplished without added expense of two-dimensional array and increased complexity of calibration. Quasi-simultaneous coupling, while maintaining optimum alignment and maximum throughput of broadband emission, achieved by use of fiber optic multiscanner. Instrument used successfully in study of frozen-flow losses internal to flow of plasma inside nozzle of arc jet. Instrument includes two hollow disks of different sizes and stepping motor.

De Groot, Wim↗

Investigation of the feasibility of optical diagnostic measurements at the exit of the SSME

Under Contract NAS8-36861 sponsored by NASA Marshall Space Flight Center, the United Technologies Research Center is conducting an investigation of the feasibility of remote optical diagnostics to measure temperature, species concentration and velocity at the exit of the Space Shuttle Main Engine (SSME). This is a two phase study consisting of a conceptual design phase followed by a laboratory experimental investigation. The first task of the conceptual design studies is to screen and evaluate the techniques which can be used for the measurements. The second task is to select the most promising technique or techniques, if as expected, more than one type of measurement must be used to measure all the flow variables of interest. The third task is to examine in detail analytically the capabilities and limitations of the selected technique(s). The results of this study are described in the section of this report entitled Conceptual Design Investigations. The conceptual design studies identified spontaneous Raman scattering and photodissociative flow-tagging for measurements respectively of gas temperature and major species concentration and for velocity. These techniques and others that were considered are described in the section describing the conceptual design. The objective of the second phase of investigations was to investigate experimentally the techniques identified in the first phase. The first task of the experimental feasibility study is to design and assemble laboratory scale experimental apparatus to evaluate the best approaches for SSME exit optical diagnostics for temperature, species concentrations and velocity, as selected in the Phase I conceptual design study. The second task is to evaluate performance, investigate limitations, and establish actual diagnostic capabilities, accuracies and precision for the selected optical systems. The third task is to evaluate design requirements and system trade-offs of conceptual instruments. Spontaneous Raman scattering excited by a KrF excimer laser pulse was investigated for SSME exit plane temperature and major species concentration measurements. The relative concentrations of molecular hydrogen and water vapor would be determined by measuring the integrated Q-branch scattering signals through narrow bandpass filters in front of photomultipliers. The temperature would be determined by comparing the signal from a single hydrogen rotational Raman line to the total hydrogen Q-branch signal. The rotational Raman line would be isolated by a monochromator and detected with a PMT.

Shirley, John A.↗

First results from a laboratory facility for measurement of emission spectra under simulated planetary conditions

We have developed a laboratory spectroscopic facility for the measurement of emission spectra under simulated planetary conditions. Spectral measurements are made from 6 to 13 microns with a scanning grating monochromator equipped with a HgCdTl detector. An environment chamber in service in Hawaii for several years in which we can control the temperature from 77 K to 500 K, the pressure from 10(exp -5) torr to two atmospheres, has been equipped with a 77 K or 273 K cold shield. The shield serves to minimize light reflected off the sample and to aid in development of thermal gradients for obtaining spectra under conditions simulating the thermal environment of airless bodies. Samples are placed in small cups on a temperature controlled substrate allowing measurements of emission due to heating from below by the substrate, or from illumination from a solar simulation source.

Lucey, Paul G.↗

Arc electrode interaction study

The project consisted of two parts: (1) the cathode interaction studies which were a continuation of previous work and had the objective of increasing our understanding of the microscopic phenomena controlling cathode erosion in arc jet thrusters, and (2) the studies of the anode attachment in arc jet thrusters. The cathode interaction studies consisted of (1) a continuation of some modeling work in which the previously derived model for the cathode heating was applied to some specific gases and electrode materials, and (2) experimental work in which various diagnostics was applied to the cathode. The specific diagnostics used were observation of the cathode tip during arcing using a Laser Strobe Video system in conjunction with a tele-microscope, a monochromator with an optical multichannel analyzer for the determination of the cathode temperature distribution, and various ex situ materials analysis methods. The emphasis of our effort was shifted to the cathode materials analysis because a parallel project was in place during the second half of 1993 with a visiting scientist pursuing arc electrode materials studies. As a consequence, the diagnostic investigations of the arc in front of the cathode had to be postponed to the first half of 1994, and we are presently preparing these measurements. The results of last year's study showed some unexpected effects influencing the cathode erosion behavior, such as increased erosion away from the cathode tip, and our understanding of these effects should improve our ability to control cathode erosion. The arc jet anode attachment studies concentrated on diagnostics of the instabilities in subsonic anode attachment arc jet thrusters, and were supplemental measurements to work which was performed by one of the authors who spent the summer as an intern at NASA Lewis Research Center. A summary of the results obtained during the internship are included because they formed an integral part of the study. Two tasks for 1994, the diagnostics of the anode closure phenomenon, and the use of arc jet thrusters for the deposition of c-BN, are being prepared.

Zhou, X.↗

State-of-the-art for large area high resolution gray scale and full color AC plasma flat panel displays

A development status evaluation is presented for gas plasma display technology, noting how tradeoffs among the parameters of size, resolution, speed, portability, color, and image quality can yield cost-effective solutions for medical imaging, CAD, teleconferencing, multimedia, and both civil and military applications. Attention is given to plasma-based large-area displays' suitability for radar, sonar, and IR, due to their lack of EM susceptibility. Both monochrome and color displays are available.

Stoller, Ray A.↗

Non-intrusive measurements in a rocket engine combustor

In recent years analytical tools to characterize combustor flow have been developed in order to support design. To facilitate anchoring of combustion related physical models and the CFD codes in which they are incorporated, considerable development and application of non-intrusive combustion diagnostic capabilities has occurred. Raman spectroscopy can be used to simultaneously detect all polyatomic molecules present in significant concentrations and to determine gas temperature. This is because all molecules possess a distinct temperature dependent Raman spectrum. A multi-point diagnostic system for non-intrusive temperature and species profiling in rocket engines has been developed at Rocketdyne. In the present effort, the system has been undergoing validation for application to rocket engine component testing. A 4 inch diameter windowed combustor with a coaxial gas-gas injector was chosen for this series of validation experiments. Initially an excimer-pumped tunable dye laser and later a solid state Nd-Yag laser served as excitation sources. The Raman signal was dispersed by a monochromator and detected by a gated, intensified Charged Coupled Device (CCD) array. Experiments were carried out prior to each series of hot fire tests to ensure that the Raman signal detected was due to a spontaneous rather than a stimulated Raman emission process. Over sixty hot fire tests were conducted during the first series of tests with the excimer/dye laser. All hot fire testing was at a mixture ratio of 0.5 and chamber pressures of approximately 100 and approximately 300 psia. The Raman spectra of hydrogen, water vapor and oxygen recorded during single element hot fire tests were reduced and analyzed. A significant achievement was the attainment of single shot Raman spectra in cold flow tests. Unfortunately, the single shot signal-to-noise ratio deteriorated to an unacceptable level during the hot fire testing. Attempts to obtain temperature data from the hydrogen Q1-branch profiles obtained in hot fire tests suggest that potentially complicating factors may render the approach of averaging data on the photodiode array invalid. A second series of hot fire tests was conducted with a 4 element coaxial injector using the Nd-Yag laser. A very compact and portable diagnostics set up was assembled for ease of alignment, relocation and flexibility. Measurements were made at several regions in the chamber in order to map concentration profiles. High spatial resolution and improved signal to noise characteristics were demonstrated.

Farhangi, S.↗

High Accuracy In-Flight Wavelength Calibration of Imaging Spectrometry Data

Accurate wavelength calibration of imaging spectrometer data is essential if proper atmospheric transmission corrections are to be made to obtain apparent surface reflectance. Accuracies of 0.1 nm are necessary for a 10 nm-sampling instrument in order to match the slopes of the deep atmospheric water vapor features that dominate the 0.7-2.3 micrometer regions. The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is calibrated in the laboratory to determine the wavelength position and full-width-half-maximum (FWHM) response for each of the 224 channels. The accuracies are limited by the quality of the monochromator used as a source. The accuracies vary from plus or minus to plus or minus 1.5 nm depending on the wavelength region, in general decreasing with increasing wavelength. Green et al. make corrections to the wavelength calibrations by using the known positions of 14 atmospheric absorption features throughout the 0.4-2.5 micrometer wavelength region. These features, having varying width and intensity, were matched to the MODTRAN model with a non-linear least squares fitting algorithm. A complete calibration was developed for all 224 channels by interpolation. Instrument calibration cannot be assumed to be stable to 0.1 nm over a flight season given the rigors of thermal cycling and launch and landing loads. The upcoming sensor HYDICE will require a means for in-flight spectral calibration of each scene because the calibration is both temperature and pressure sensitive. In addition, any sensor using a two-dimensional array has the potential for systematic wavelength shifts as a function of cross-track position, commonly called 'smile'. Therefore, a rapid means for calibrating complete images will be required. The following describes a method for determining instrument wavelength calibration using atmospheric absorption features that is efficient enough to be used for entire images on workstations. This study shows the effect of the surface reflectance on the calibration accuracy and the calibration history for the AVIRIS B spectrometer over the 1992 flight season.

Goetz, Alexander F. H.↗

Low-light video observations of frequent luminous structures in the stratosphere above thunderstorms

A new series of video measurements were made of the phenomenon provisionally termed the cloud-to-stratosphere (CS) event, an electrical discharge extending to great heights above thunderstorm tops. This new series of measurements were accomplished by properly positioning a sensor, the Xybion model ISS 225 low-light monochrome imaging system with a C-mount fl.8 manual zoom lens, and training it on the appropriate portion of the sky above a distant thunderstorm complex mean Fort Collins, Colorado. The resulting images are currently undergoing intensive analysis. Some tentative conclusions are given. Cloud-to-stratosphere events occur far more frequently than previously suspected and are perhaps a ubiquitous aspect of many larger convective systems. Cloud-to-stratosphere events are also of substantial horizontal extent, on the order of tens of kilometers in some cases.

Lyons, Walter A.↗

Wavelength-resolved emission spectroscopy of the alkoxy and alkylthio radicals in a supersonic jet

Wavelength-resolved emission spectra of methoxy (CH3O) and methylthio (CH3S) radicals have been obtained in a supersonic jet environment with a resolution of 0.3 nm by dispersing the total laser-induced fluorescence with a 0.6 m monochromator. A detailed analysis of the single vibronic level dispersed fluorescence spectra yields the following vibrational frequencies for CH3O in the X(2)E state; nu(sub 1 double prime) = 2953/cm, nu(sub 2 double prime) = 1375/cm, nu(sub 3 double prime) = 1062/cm, nu(sub 4 double prime) = 2869/cm, nu(sub 5 double prime) = 1528/cm and nu(sub 6 double prime) = 688/cm. A similar analysis of the wavelength-resolved emission spectra of CH3S provides the following ground state vibrational frequencies: nu(sub 2 double prime) = 1329/cm, nu(sub 3 double prime) = 739/cm and nu(sub 6 double prime) = 601/cm. An experimental uncertainty of 20/cm is estimated for the assigned frequencies.

Misra, Prabhakar↗

SSME propellant path leak detection

Initial research established that the occurrence of a leak in the powerhead of the Space Shuttle Main Engine (SSME) is accompanied by a sudden, but sustained, change in intensity in a given region of an image. Based upon this, temporal processing of video images on a frame-by-frame basis has been used to detect leaks within a given field of view. The leak detection algorithm developed in this study consists of a digital highpass filter cascaded with a moving average filter applied at each point in the image field. The absolute value of the output is then averaged over the full frame to produce a single time-varying mean value estimate that is indicative of the intensity and extent of a leak. Recent work has included the processing of an extensive amount of data obtained from NASA MSFC to verify the performance of the leak detection system. Further research is being conducted on applying the leak detection algorithm to anomaly detection in the SSME exhaust by means of three channel color processing as opposed to single channel monochrome processing in the case of the leak detection system.

Smith, L. M.↗

Xenon lighting adjusted to plant requirements

Xenon lamps are available as low and high power lamps with relatively high efficiency and a relatively long lifetime up to several thousand hours. Different construction types of short-arc and long-arc lamps permit a good adaptation to various applications in projection and illumination techniques without substantial changes of the spectral quality. Hence, the xenon lamp was the best choice for professional technical purposes where high power at simultaneously good spectral quality of the light was required. However, technical development does not stand still. Between the luminous efficacy of xenon lamps of 25-50 lm/W and the theoretical limit for 'white light' of 250 lm/W is still much room for improvement. The present development mainly favors other lamp types, like metal halide lamps and fluorescent lamps for commercial lighting purposes. The enclosed sections deal with some of the properties of xenon lamps relevant to plant illumination; particularly the spectral aspects, the temporal characteristics of the emission, and finally the economy of xenon lamps will be addressed. Due to radiation exceeding the natural global radiation in both the ultraviolet (UV) and the infrared (IR) regions, filter techniques have to be included into the discussion referring to the requirements of plant illumination. Most of the presented results were obtained by investigations in the GSF phytotron or in the closed Phytocell chambers of the University of Erlangen. As our experiences are restricted to area plant illumination rather than spot lights our discussion will concentrate on low pressure long-arc xenon lamps which are commonly used for such plant illuminations. As the spectral properties of short-arc lamps do not differ much from those of long-arc lamps most of our conclusions will be valid for high pressure xenon lamps too. These lamps often serve as light sources for small sun simulators and for monochromators which are used for action spectroscopy of plant responses.

Koefferlein, M.↗

Thermodynamic measurements in a high pressure hydrogen-oxygen flame using Raman scattering from a broadband excimer laser

Raman scattering is an inelastic molecular scattering process in which incident radiation is reemitted at a fixed change in frequency. Raman spectroscopy can be used to measure the number density and temperature of the irradiated species. The strength of the Raman signal is inversely proportional to the wavelength raised to the fourth power. Consequently, high signal to noise ratios are obtained by using ultraviolet (UV) excitation sources. Using UV sources for Raman Spectroscopy in flames is complicated by the fact that some of the primary constituents in hydrogen-oxygen combustion absorb and reemit light in the UV and these fluorescence processes interfere with the Raman signals. This problem has been handled in atmospheric pressure flames in some instances by using a narrowband tunable excimer laser as a source. This allows for detuning from absorption transitions and the elimination of interfering fluorescence signals at the Raman wavelengths. This approach works well in the atmospheric pressure flame; however, it has two important disadvantages. First, injection-locked narrowband tunable excimer lasers are very expensive. More importantly, however, is the fact that at the high pressures characteristic of rocket engine combustion chambers, the absorption transitions are broadened making it difficult to tune to a spectral location at which substantial absorption would not occur. The approach taken in this work is to separate the Raman signal from the fluorescence background by taking advantage of the fact that Raman signal has nonisotropic polarization characteristics while the fluorescence signals are unpolarized. Specifically, for scattering at right angles to the excitation beam path, the Raman signal is completely polarized. The Raman signal is separated from the fluorescence background by collecting both horizontally and vertically polarized signals separately. One of the polarizations has both the Raman signal and the fluorescence background while the other has only the fluorescence signal. The Raman scatter is the difference between the signals. By choosing an appropriate optical setup, both signals can be obtained simultaneously with the same monochromator; hence, time resolved measurements are possible using this approach.

Hartfield, Roy, Jr.↗

Laser-Induced Incandescence Calibration via Gravimetric Sampling

Various beam imaging and/or sheet forming optics delivered light at 1064 nm from a pulsed Nd:YAG laser for use either as a beam of 3 mm radius or as a laser sheet. Imaging measurements were performed with a grated intensified array camera equipped with an ultraviolet f4.5 lens and a 40 mm extension tube. Point measurements were performed using an ultraviolet 250 mm focal length lens to collect and focus the laser induced incandescence (LII) signal into a 1 meter long quartz optical fiber which directed the LII signal to a 1/4 meter monochromator. An aperture preceding the lens restricted the signal collection region to 1 cm along the laser beam at the center of the gravimetric chimney. Signals from the PMT were processed by a boxcar integrator whereas the images were captured digitally using a frame-grabber with 16 MByte of on-board memory. Both 'point' and planar measurements were made with detector gates of 250 ns to minimize possible morphology bias in collection of the LII signal. Additionally, the imaging measurements were performed with broadband spectral collection of the LII signal to maximize the signal and again minimize any potential effects of morphology dependent heating and/or cooling rates. Digital delay generators controlled the firing of he laser, detector gates and data acquisition. Neutral density filters were used for both sets of measurements to maintain signal levels within linear dynamic ranges of the detectors, the range being determined prior to experiments.

VanderWal, R. L.↗