Molecular outgassing measurements for an element of the Shuttle thermal protection system
Molecular outgassing studies were conducted on a thermal-protection material recently developed for the Shuttle Orbiter. Molecular outgassing rates as low as 10 to the minus 11th g/sq cm/sec, condensation coefficients, and molecular desorption rates were measured in four separate experiments using cryogenically and thermoelectrically cooled quartz crystal microbalances. Although the initial outgassing rates are high, they decreased to values in the 10 to the minus 10th g/sq cm/sec range in a reasonable period of time. Outgassing rates do not increase after entry heating although the condensation coefficients at various microbalance collection-surface temperatures become somewhat larger.