Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “module temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Resolving ECRH deposition broadening due to edge turbulence in DIII-D

Microwave heat pulse propagation experiments have demonstrated a correlation between millimeter-scale turbulence and deposition profile broadening of electron cyclotron (EC) waves on the DIII-D tokamak. In a set of discharges in DIII-D, a variation in edge density fluctuations on the mm-scale is associated with 40%–150% broader deposition profiles, expressed in terms of normalized minor radius, as compared with equilibrium ray tracing. The 1D power profile is determined from transport analysis of the electron temperature response to EC power modulation using perturbative analysis with a square wave power modulation at 20–70 Hz, producing a series of Fourier harmonics that are fit collectively to resolve transport. Fitting an integrated heat flux expressed in the Fourier basis of the modulation to diffusive, convective, and coupled transport terms in a linear model can resolve the broadened EC deposition width from the power perturbation to resolve a broadening in each case. The best fit degree of beam broadening observed scales approximately linearly with the Doppler backscattering measured fluctuation level in the steep gradient region. Quantifying the effect of edge fluctuation broadening on EC current drive power needs of future devices will require 3D full-wave codes that can be validated on the current generation of machines. These DIII-D experiments provide a quantitative measure of fluctuation effects and a dataset to benchmark full-wave simulations that can model and eventually predict nonlinear effects neglected by 1D equilibrium beam and ray tracing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron kinetics in a positive column of AC discharges in a dynamic regime

Abstract We have performed hybrid kinetic-fluid simulations of a positive column in alternating current (AC) argon discharges over a range of driving frequencies f and gas pressure p for the conditions when the spatial nonlocality of the electron energy distribution function (EEDF) is substantial. Our simulations confirmed that the most efficient conditions of plasma maintenance are observed in the dynamic regime when time modulations of mean electron energy (temperature) are substantial. The minimal values of the root mean square electric field and the electron temperature have been observed at f/p values of about 3 kHz Torr −1 in a tube of radius R = 1 cm. The ionization rate and plasma density reached maximal values under these conditions. The numerical solution of a kinetic equation allowed accounting for the kinetic effects associated with spatial and temporal nonlocality of the EEDF. Using the kinetic energy of electrons as an independent variable, we solved an anisotropic tensor diffusion equation in phase space. We clarified the role of different flux components during electron diffusion in phase space over surfaces of constant total energy. We have shown that the kinetic theory uncovers a more exciting and rich physics than the classical ambipolar diffusion (Schottky) model. Non-monotonic radial distributions of excitation rates, metastable densities, and plasma density have been observed in our simulations at pR > 6 Torr cm. The predicted off-axis plasma density peak in the dynamic regime has never been observed in experiments so far. We hope our results stimulate further experimental studies of the AC positive column. The kinetic analysis could help uncover new physics even for such a well-known plasma object as a positive column in noble gases.

Physics↗

Order-parameter evolution in the Fulde-Ferrell-Larkin-Ovchinnikov phase

Here, we report on the temperature dependence of the spatially modulated spin-polarization amplitude ΔK spin , which is a hallmark of the superconducting Fulde-Ferrell-Larkin-Ovchinnikov (FFLO) state. For that, we use 13 C nuclear magnetic resonance (NMR) spectroscopy performed on the organic conductor β" -(ET) 2 SF 5 CH 2 CF 2 SO 3 . From a comparison of our experimental results to a comprehensive modeling of the 13 C NMR spectra, we determine the evolution of ΔK spin upon condensation of the FFLO state. Further, the modeling of the spectra in the superconducting phase allows to quantify the decrease of the average spin susceptibility, stemming from the spin-singlet coupling of the superconducting electron pairs in the FFLO state of β" -(ET) 2 SF 5 CH 2 CF 2 SO 3 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multiscale Electrothermal Design of a Modular Multilevel Converter for Grid-Tied Applications

As a key feature of modular multilevel converters (MMCs), a large number of semiconductor devices are employed in the converter and distributed over a stack of submodules. Each submodule has a strict temperature limit that imposes constraints on the operating range of the converter. Different loading conditions/losses in the submodules lead to unavoidable temperature variations inside the MMC, which consequently affect the system-level performance and reliability. This paper is focused on the electrothermal analysis and design of a medium-voltage silicon carbide (SiC)-based MMC system, from submodule power semiconductors to the overall MMC system integration of multiple submodules. Loss calculations are performed to estimate the cooling requirements and aid thermal design at different levels. The performance of forced-air cooling approach is analyzed within a numerical modeling framework. Maximum temperature of the SiC power modules is predicted using numerical tools. Thermal design of the MMC cabinet with various arrangement of air inlet(s) and outlet(s) is investigated and compared from a cooling performance perspective.

CFD↗

The QBO–MJO Connection: A Possible Role for the SST and ENSO

We examine the hypothesis that the observed connection between the stratospheric quasi-biennial oscillation (QBO) and the strength of the Madden–Julian oscillation (MJO) is modulated by the sea surface temperature (SST)—for example, by El Niño–Southern Oscillation (ENSO). A composite analysis shows that, globally, La Niña SSTs are remarkably similar to those that occur during the easterly phase of the QBO. A maximum covariance analysis suggests that MJO power and SST are strongly linked on both the ENSO time scale and the QBO time scale. We analyze simulations with a modified configuration of version 2 of the Community Earth System Model, with a high top and fine vertical resolution. The model is able to simulate ENSO, the QBO, and the MJO. The ocean-coupled version of the model simulates the QBO, ENSO, and MJO, but does not simulate the observed QBO–MJO connection. When driven with prescribed observed SST anomalies based on composites for QBO east and QBO west (QBOE and QBOW), however, the same atmospheric model produces a modest enhancement of MJO power during QBOE relative to QBOW, as observed. We explore the possibility that the SST anomalies are forced by the QBO itself. Indeed, composite Hovmöller diagrams based on observations show the propagation of QBO zonal wind anomalies all the way from the upper stratosphere to the surface. Also, subsurface ocean temperature composites reveal a similarity between the western Pacific and Indian Ocean subsurface signal between La Niña and QBOE.

54 ENVIRONMENTAL SCIENCES↗

Integrated Heat Exchanger-Phase Change Material Thermal Energy Storage System

The purpose of this study is to experimentally investigate the thermal performance of an innovative thermal energy storage (TES) system that combines the advantages of the phase-change material (PCM)/graphite foam latent heat TES medium developed at Argonne National Laboratory (Argonne) and the internally supported plate-fin (ISPE) cell architecture heat transfer fluid (HTF) flow channels developed at Brayton Energy (Brayton). Several essential tasks were accomplished: (1) Thermal property characterization. Thermal properties of the graphite foam were characterized, providing necessary data for experimental result analysis and numerical simulation. (2) Design and optimization of lab-scale test module. Based on Brayton’s full-scale heat exchanger (HX)-TES system, the experimental test module was designed, optimized, and fabricated. (3) Thermal performance testing and data analysis. Five cycle tests were successfully conducted—including one with approximately 3.5 psig of pressure applied to the diaphragms—to investigate the thermal performance of the experimental test module for charging and discharging. Temperature profiles were generated for each charging test and discharging test as a function of time. The temperature profiles clearly show three TES stages: sensible heat (temperature increase), latent heat (melting), and sensible heat (temperature increase) for the charging process. Similarly, the temperature profiles clearly show three thermal energy release stages: sensible heat (temperature decrease), latent heat (solidification), and sensible heat (temperature decrease). Melting and solidification of the PCM generally occurred in relatively narrow temperature ranges, indicated by the flattened temperature regions in the temperature profiles. These phase changes ranged approximately 3°C for melting and 3.5°C for solidification. The charging and discharging temperature profiles were similar for similar experimental parameter tests whether or not pressure was applied to the diaphragm to eliminate the gap between the HX surface and the TES subsystem. This indicates that the effect of a small gap between the HX surface and the TES subsystem is insignificant for charging and discharging. (4) Comparison of experimental data and simulation results. We compared the experimental data to the numerical simulation results. Numerical simulations were conducted by using the ANSYS FLUENT 2019 R3 commercial computational fluid dynamics software. The predicted phase-change times agreed reasonably well with those from the experimental data. In most cases, the estimated time differences between the relative phase changes were within 16%. The predicted start and end times for the charging process agreed well with those from the experimental data. However, the simulation results showed earlier start and end times than the experimental data for the discharging process. Overall, the experimental data and its comparison with the simulation predictions verified the technical viability of the integrated ISPF HX-PCM/graphite foam latent-heat TES system.

25 ENERGY STORAGE↗

Novel Modular Residential CCHP for Space Conditioning and Water Heating

This presentation will first describe the design of a novel modular residential cold-climate heat pump for both space conditioning and water heating that can be coupled with thermal energy storage (TES) to maximize system efficiency and load flexibility. Among some of the novel operating modes of the proposed design include: 1) simultaneous outdoor coil defrost while still providing space heating or water heating; 2) simultaneous water heating and space cooling 3) using the TES as the heat source during cold climate operation to improve efficiency and 4) compressorless charging of the TES module during days with high temperature swings between night and day. Then, initial simulation results will be presented describing system performance in key operating modes in climate region 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar Thermal Energy Planner (STEP 1): A New Decision Support Tool for Solar Industrial Process Heat Applications

Solar thermal technologies are a promising technology to supply low-cost thermal energy to industrial processes, but there are often significant barriers to entry to industrial owners considering these technologies for their energy demands. To overcome this barrier and convey economic value to customers, NREL and Sandia National Laboratories developed Solar Thermal Energy Planner (STEP 1), a new web-based decision support tool for solar industrial process heat systems. At SolarPACES 2024, the STEP 1 tool was still under development; progress, methodologies, and a preliminary case study was presented. With the STEP 1 tool launch in May 2025, in this work, the initial version of the full public tool will be presented with demonstrations of its capabilities using a few case studies. First, the user's process heat needs such as location, process media (e.g., steam, air), process temperature, land availability, electricity and fuel costs, among other parameters. STEP 1 features a mapping interface that allows users to draw land and roof boundaries. The process media and temperature inform technology selection criteria modules that determine the appropriate solar thermal collection technologies, as well as congruent heat transfer media (e.g., hot water, oil, salt). Once the solar thermal technology selected, its nominal thermal production for the given site is characterized using NREL's System Advisor Model (SAM). Then, a modified version of NREL's REopt optimal sizing and dispatch optimization tool determines cost-optimal sizing. Within minutes, the user receives the results of the technoeconomics analysis, including the size and performance of the cost-optimal solar-plus-storage system. The cost of the system is compared to business-as-usual (e.g., an existing, standalone natural gas boiler). Users can download key results to store for sensitivity analyses. Examples of flat plate collector, parabolic trough, and molten salt tower applications with and without PV hybridization for different industrial facility types are presented in this work. The STEP 1 tool aims to reduce barriers to the adoption of solar heating solutions stemming from a lack of familiarity and technical background with solar system design options and costs among industry stakeholders.

14 SOLAR ENERGY↗

High Voltage High Power Traction Inverter Thermal Management

This project develops thermal management solutions for various 530-kW inverter topologies being developed by Oak Ridge National Laboratory (ORNL). The thermal management solutions will provide high thermal performance and be designed to keep inverter components (e.g., power modules, capacitors) within allowable operating temperatures to help meet the project objectives. Steady-state and transient thermal models of the inverter and cooling system will be created and used to predict component temperatures under various drive cycle conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Asteroid Measurements at Millimeter Wavelengths with the South Pole Telescope

Abstract We present the first measurements of asteroids in millimeter wavelength data from the South Pole Telescope (SPT), which is used primarily to study the cosmic microwave background (CMB). We analyze maps of two ∼270 deg2 sky regions near the ecliptic plane, each observed with the SPTpol camera ∼100 times over 1 month. We subtract the mean of all maps of a given field, removing static sky signal, and then average the mean-subtracted maps at known asteroid locations. We detect three asteroids—(324) Bamberga, (13) Egeria, and (22) Kalliope—with signal-to-noise ratios (S/N) of 11.2, 10.4, and 6.1, respectively, at 2.0 mm (150 GHz); we also detect (324) Bamberga with an S/N of 4.1 at 3.2 mm (95 GHz). We place constraints on these asteroids’ effective emissivities, brightness temperatures, and light-curve modulation amplitude. Our flux density measurements of (324) Bamberga and (13) Egeria roughly agree with predictions, while our measurements of (22) Kalliope suggest lower flux, corresponding to effective emissivities of 0.64 ± 0.11 at 2.0 and < 0.47 at 3.2 mm. We predict the asteroids detectable in other SPT data sets and find good agreement with detections of (772) Tanete and (1093) Freda in recent data from the SPT-3G camera, which has ∼10× the mapping speed of SPTpol. This work is the first focused analysis of asteroids in data from CMB surveys, and it demonstrates we can repurpose historic and future data sets for asteroid studies. Future SPT measurements can help constrain the distribution of surface properties over a larger asteroid population.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of Irradiation-induced Microstructural Defects on Thermal Transport in Single Crystal Thorium Dioxide

Microstructural defects formed as a result of fission fragment damage are known to drastically alter thermal conductivity, a fuel property that governs the efficiency of a nuclear reactor. A fundamental understanding of radiation-induced effects on thermal transport is critical for the development of advanced fuels. Ion-irradiation has widely been used to simulate the effects of neutron-irradiation by seeding atomic-to-nanoscale defects of controllable size and density. In this work, we investigate the influence of microstructural defects, induced by ion-irradiation, on the thermal properties of single crystal thorium dioxide samples grown using the hydrothermal technique. The samples were irradiated using 2 MeV protons at room temperature. A laser-based modulated thermoreflectance technique was used to measure the thermal diffusivity and conductivity within the damaged ThO2 region. The experimentally measured thermal properties were compared with Boltzmann Transport Equation predictions, to determine the impact of various defect types on the thermal properties of ThO2.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of the DC bus link capacitors and power transistor modules in the qualification testing of PV inverters

To achieve useful, fair, and cost-effective design qualification and type approval testing for PV inverters, two procedures were developed and demonstrated to evaluate the bus link capacitors and power transistor—and where applicable, its module—for long-term reliability. We evaluate the inverter under simulated use conditions with heat run tests to find the highest operating temperatures reached by these components. The procedures are demonstrated in this study with a 4-kVA class string inverter. The maximum temperature of the DC bus link capacitors was determined to be 76.4°C when the ambient temperature was at the inverter's maximum rated temperature of 60°C with derating occurring. On the other hand, the power transistor module's maximum temperature using the heat sink temperature as the index, 92.6°C, occurred in an ambient of 40.8°C when derating was not occurring. The conditions found for upper temperatures exhibited by these components are, respectively, proposed for implementation in the dry heat and thermal cycling tests in the IEC 62093 “Power conversion equipment for photovoltaic systems – Design qualification testing” international standard draft so that the levels applied in the tests are in proportion to those experienced in the field. Finally as a result, fairer evaluation of inverter reliability is realized.

14 SOLAR ENERGY↗

Understanding and Overcoming Water-induced Interfacial Degradation in Si Modules (Final Technical Report)

Moisture ingress is an established issue for photovoltaic module durability. Durability studies probing moisture effects typically evaluate performance losses at the module level, attributing global power losses to the overall humidity condition of the test environment while leaving local module behavior unknown. This project successfully develops an in situ short-wave infrared probe of moisture content in PV modules with demonstrated detection limits better than 100 ppm in EVA-encapsulated Al-BSF and PERC architectures (66 µg/cm3) and applicability across the range of terrestrial conditions. Combining this optical moisture quantification method (water reflectometry detection, WaRD) with peel testing of interfaces, biased photoluminescence imaging of performance, and first principles computation, we correlate module moisture content and cell performance over the course of accelerated damp heat tests. By performing multi-level humidity and thermal accelerated testing over thousands of hours (0, 65 and 85% RH and 25, 65, and 85°C), we are able to attribute effects of individual environmental stresses and the dependence on module architecture. Using first-principles computational chemistry, we find that the decomposition of EVA to acetic acid (Norrish II) is thermodynamically preferred over a pathway to acetaldehyde (Norrish I), elucidating the underlying chemistry of encapsulant degradation. We also find it is likely that water segregates to the stable interfaces of the cell, especially the SiNx/EVA interface. We find that moisture is strongly correlated with reduction in adhesion at the interfaces of the cells, particularly at Ag fingers. We show uniquely that the peel strength required to delaminate the encapsulant from the front of the cell depends not only on the exposure to a high heat and humid environment, but also to the moisture content during the mechanical testing, indicating an important interaction between when mechanical stresses are faced in terms of the moisture content of the module and its durability. We find that the background sheet resistance (that is, the sheet resistance rise not attributable to finger interruptions or cracks) is substantially higher in the backsheet mini-modules vs glass-glass packages when humidity and temperature are faced. This increase in power loss due to the background resistance increase over time in damp heat in glass-backsheet modules resulted in ~3-4% larger decrease in relative PCE compared to glass-glass modules. In glass-backsheet modules, the effect of the moisture dose alone is comparable or greater than that of the combined temperature and water term, suggesting that glass-backsheet modules are overall more susceptible to moisture induced performance loss. Finally, we show that thin film PV modules are amenable to WaRD measurement, based on the ability to detect moisture in POE encapsulants or in the cell stack itself. The ease of WaRD measurement and its few requirements on the bill of materials should enable broad applicability of this technique for studying the effects of moisture in PV.

14 SOLAR ENERGY↗

Semiclassical theory of bipolaronic superconductivity in a bond-modulated electron-phonon model

We analyze the transition temperature T c of bipolaronic superconductivity in a bond Su-Schrieffer-Heeger (bond-SSH) model—also known as a bond Peierls model—where the electron hoppings are modulated by bond phonons. Using a semiclassical instanton approximation justifiable in the adiabatic limit of slow phonons, we find that the bipolaron mass is only weakly enhanced, in contrast to the typical large mass enhancement found in standard (Holstein) electron-phonon models. Specifically, in the strong coupling limit, the bipolarons can freely slide within a degenerate manifold rather than become self-trapped. A gas of these bipolarons can undergo a superfluid transition at a critical temperature for which we obtain an upper bound. We find that this bound is exponentially larger than that in the Holstein model. In conclusion, our study provides an analytical understanding of the mechanism behind the high-T c bipolaronic superconductivity numerically observed in [Phys. Rev. X 13, 011010 (2023)].

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Silicon wafer fracture stress for tracking sensors in particle physics experiments

For the construction of the ATLAS Inner Tracker strip detector, silicon strip sensor modules are glued directly onto carbon fibre support structures using a soft silicone gel. During tests at temperatures below -35°C, several of the sensors were found to crack due to a mismatch in coefficients of thermal expansion between polyimide circuit boards with copper metal layers (glued onto the sensor) and the silicon sensor itself. While module assembly procedures were developed to minimise variations between modules, cold tests showed a wide range of temperatures at which supposedly comparable modules failed. The observed variance (fracture temperatures between -35°C and -70°C) for supposedly comparable modules suggests an undetected variation between modules suspected to be intrinsic to the silicon wafer itself. Therefore, a test programme was developed to investigate the fracture stress of representative sensor wafer cutoffs. This paper presents results for the fracture stress of silicon sensors used in detector modules.

Detector design and construction technologies and ↗

Screening Metal Halide Perovskite Solar Modules for Premature Field Failures

Developing metal halide perovskite (MHP) photovoltaic (PV) devices into reliable large-area solar modules could accelerate global solar energy deployment. Many MHP devices are susceptible to degradation under light and elevated temperature (LT). Published research on LT testing is limited at the module level, and LT testing has not yet been developed for qualification testing of commercial PV products. This report assesses whether results of LT testing at moderately elevated temperatures correlate with those of field-tested modules from the same batch. Six batches of samples from four manufacturers are assessed. It is shown that modules with a robust package that can maintain over 80% of their peak efficiency during LT testing at 55 °C for 100 h are more likely to retain over 80% of their peak efficiency during outdoor operation for 10 weeks. This finding is a step towards developing a validated test protocol that could be incorporated into a qualification standard for the commercialization of MHP PV technologies.

14 SOLAR ENERGY↗

Thermal Stress Reduction in Power Switching Devices Using Distributed Loss PWM Concept for Current Source Inverters

A new modulation scheme is proposed for current source inverters (CSIs) that reduces the variation and peak junction temperature in the CSIs' power devices. The distributed loss pulse-width modulation (DLM) concept is introduced and applied to traditional space vector modulation methods to develop modified modulation schemes that reduce the thermal stress on power devices. The device junction temperatures resulting from conventional and DLM schemes are compared. Simulation and experimental results confirm that the proposed DLM concept reduces thermal stress on the devices while maintaining the same high output current waveform quality compared to traditional CSI modulation schemes. The CSI power device lifetime (i.e., the number of cycles to failure) are estimated using the simulation and experimental results. The proposed DLM significantly increases the device lifetime (by 5 to 6 times) by reducing the junction temperature variation compared to the conventional modulations.

42 ENGINEERING↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗