Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mixture analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Development of Methods for In-line Monitoring of Yield Stress During the Transfer of Radioactive Waste - 20435

Radioactive waste slurries at the Savannah River Site (SRS) and Hanford often behave as non-Newtonian fluids with a yield stress. The yield stress increases the size of equipment needed to transport or mix these slurries and can increase the risk of process upsets. This property is often measured by collection of samples and transportation to a laboratory, which can increase the risk of personnel exposure and even change the rheology. In addition, slurry rheology has been observed to change with time. Real-time in-line monitoring (RTIM) of rheological properties of slurries can have substantial benefits to critical processes which are currently in operation or will be part of future plans in Department of Energy (DOE) complex processes. The need for an appropriate RTIM technology that can potentially minimize or eliminate numerous sampling operations was recently identified. This research at Florida International University focuses on addressing the need for a reliable RTIM technology at US Department of Energy sites. The objective of this work is to investigate and develop appropriate and reliable technologies that can perform accurate and easy measurements of yield stress with minimal changes to the flow conditions at US Department of Energy sites. Use of ultrasound in longitudinal and shear modes was considered as a method for monitoring of yield stress variations with no disturbance to the flow. Measurement of shear wave velocity (in shear mode) and monitoring of sound velocity variations with start of flow from rest (longitudinal mode) are the underlying principles. Measurement of pressure loss and liquid rise (due to static differential pressure) during flow of slurries were two other methods that were considered and investigated. In addition, analysis of stability depth of a penetrometer in slurry medium (penetrometer method) revealed a potential suitability. This paper presents efforts associated with investigation of different methods mentioned earlier for kaolin-water mixtures at different concentrations. Theoretical analysis showed that all methods under investigation were capable of monitoring yield stress in a desirable range of 0 to 70 pascal. A bench scale test setup was constructed for investigation of pressure loss and liquid rise methods. Simulants at different concentrations were created for initial testing campaigns. For ultrasonic testing, effects of yield stress on sound propagation speed in longitudinal and shear modes were investigated for simulants placed inside PVC pipes. Parameters such as simulant concentration and pipe diameter were varied to find optimal values. It was found that spacing (or medium thickness) of 1/8 inch or less was necessary to observe echoes with sufficient strength. In addition, a significant effect of yield stress on sound propagation velocity was observed. For the liquid rise method, kaolin-water simulant at 1.17 specific gravity was pumped through a 1/4 inch pipe and liquid height was measured in a vertical riser branching off a three-way connection. Static gauge pressure was varied within [0.3 to 1.1] psi range by increase of pumping pressure and flow. Results showed consistent yield stress data within 10% deviation from values reported by a rheometer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy deposition in a gaseous mixture

Existing models in planetary aeronomy involve a variety of possible gaseous mixtures subjected to charged particle bombardment. In the present paper, a phenomenological approach to electron degradation in such mixtures is proposed to facilitate analysis of such problems. Existing parameterized yield spectra for a variety of gases, computed by a discrete energy bin method, are used as a basis for constructing a parameterized composite yield spectrum for an arbitrary mixture. The approach proposed is an improvement over the continuous slow-down approximation in that discreteness is taken into account phenomenologically. The advantages are in the ease of application to aeronomical problems involving variable mixtures.

Peterson, L. R.↗

Time and wavelength domain algorithms for chemical analysis by laser radar

Laser-induced fluorescence (LIF) is a promising technique for laser radar applications. Laser radar using LIF has already been applied to algae blooms and oil slicks. Laser radar using LIF has great potential for remote chemical analysis because LIF spectra are extremely sensitive to chemical composition. However, most samples in the real world contain mixtures of fluorescing components, not merely individual components. Multicomponent analysis of laser radar returns from mixtures is often difficult because LIF spectra from solids and liquids are very broad and devoid of line structure. Therefore, algorithms for interpreting LIF spectra from laser radar returns must be able to analyze spectra that overlap in multicomponent systems. This paper analyzes the possibility of using factor analysis-rank annihilation (FARA) to analyze emission-time matrices (ETM) from laser radar returns instead of excitation-emission matrices (EEM). The authors here define ETM as matrices where the rows (or columns) are emission spectra at fixed times and the columns (or rows) are temporal profiles for fixed emission wavelengths. Laser radar usually uses pulsed lasers for ranging purposes, which are suitable for measuring temporal profiles. Laser radar targets are hard instead of diffuse; that is, a definite surface emits the fluorescence instead of an extended volume. A hard target would not broaden the temporal profiles as would a diffuse target. Both fluorescence lifetimes and emission spectra are sensitive to chemical composition. Therefore, temporal profiles can be used instead of excitation spectra in FARA analysis of laser radar returns. The resulting laser radar returns would be ETM instead of EEM.

Rosen, David L.↗

Bioactivity Profiling of Chemical Mixtures for Hazard Characterization

Abstract The assessment and regulation of chemical toxicity to protect human health and the environment are done one chemical at a time and seldom at environmentally relevant concentrations. However, chemicals are found in the environment as mixtures, and their toxicity is largely unknown. Understanding the hazard posed by chemicals within the mixture is critical to enforce protective measures. Here, we demonstrate the application of bioactivity profiling of environmental water samples using the sentinel and ecotoxicology model species Daphnia to reveal the biomolecular response induced by exposure to real-world mixtures. We exposed a Daphnia strain to 30 sampled waters of the Chaobai River and measured the gene expression response profiles. Using a multiblock correlation analysis, we establish correlations between chemical mixtures identified in 30 water samples with gene expression patterns induced by these chemical mixtures. We identified 80 metabolic pathways putatively activated by mixtures of inorganic ions, heavy metals, polycyclic aromatic hydrocarbons, industrial chemicals, and a set of biocides, pesticides, and pharmacologically active substances. Our data-driven approach discovered both known bioactivity signatures with previously described modes of action and new pathways linked to undiscovered potential hazards. This study demonstrates the feasibility of reducing the complexity of real-world mixture toxicity to characterize the biomolecular effects of a defined number of chemical components based on gene expression monitoring of the sentinel species Daphnia.

Engineering↗

The Investigation of Chlorate and Perchlorate/Saponite Mixtures as a Possible Source of Oxygen and Chlorine Detected by the Sample Analysis at Mars (SAM) Instrument in Gale Crater

The Sample Analysis at Mars (SAM) instrument on board the Curiosity Rover has detected O2 and HCl gas releases from all analyzed Gale Crater sediments, which are attributed to the presence of perchlorates and/or chlorates in martian sediment. Previous SAM analog laboratory analyses found that most pure perchlorates and chlorates release O2 and HCl at different temperatures than those observed in the SAM data. Subsequent studies examined the effects of perchlorate and chlorate mixtures with Gale Crater analog iron phases, which are known to catalyze oxychlorine decomposition. Several mixtures produced O2 releases at similar temperatures as Gale Crater materials, but most of these mixtures did not produce significant HCl releases comparable to those detected by the SAM instrument. In order to better explain the Gale Crater HCl releases, perchlorates and chlorates were mixed with Gale Crater analog saponite, which is found at abundances from 8 to 20 wt % in the John Klein and Cumberland drill samples. Mixtures of chlorates or perchlorates with calcium-saponite or ferrian-saponite were heated to 1000 deg C in a Labsys EVO differential scanning calorimeter/mass spectrometer configured to operate similarly to the SAM oven/quadrupole mass spectrometer system. Our results demonstrate that all chlorate and perchlorate mixtures produce significant HCl releases below 1000 deg C as well as depressed oxygen peak release temperatures when mixed with saponite. The type of saponite (calcium or ferrian saponite) did not affect the evolved gas results significantly. Saponite/Mg-perchlorate mixtures produced two HCl releases similar to the Cumberland drilled sample. Mg-chlorate mixed with saponite produced HCl releases similar to the Big Sky drilled sample in an eolian sandstone. A mixture of Ca-perchlorate and saponite produced HCl and oxygen releases similar to the Buckskin mudstone drilled sample and the Gobabeb 2 eolian dune material. Ca-chlorate mixed with saponite produced both HCl and oxygen releases within the same range as the Rock-nest windblown deposit, the Greenhorn eolian sandstone, and the John Klein drilled mudstone. Overall, mixtures of perchlorates or chlorates with saponite provide the first explanation for the high temperature HCl releases in addition to the oxygen releases observed in Gale Crater materials.

Clark, J.↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

A chemical analysis of soil-water mixtures and the first microscopic images of martian soil will be among the results to be returned by the Mars Environmental Compatibility Assessment (MECA) payload on the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's primary goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. As a survey of soil properties, the MECA data set will also be rich in information relevant to basic geology, paleoclimate, and exobiology. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases. Cyclic voltammetry will address oxidants, and anodic stripping voltammetry will probe potentially hazardous trace metals. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in a controlled illumination environment to image dust and soil particles from millimeters to nanometers in size. Careful selection of substrates and an abrasion tool allows experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. Mounted on the end of the robot arm, MECA's electrometer consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultra-violet- light-induced ions and a low-voltage break-down threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. In addition, the electrostatic environment is key to transport of dust and, consequently, martian meteorology. MECA will also observe natural dust accumulation on engineering materials. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the inter-action between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. Dust accumulation as a function of conductivity, magnetic field strength, and other parameters will be explored. The MECA instruments described above will assess potential hazards that the Martian soil might present to human explorers and their equipment. In addition, MECA will provide information on the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation. Additional information is contained in the original extended abstract.

Hecht, M. H.↗

The Investigation of Magnesium Perchlorate/Iron Phase-mineral Mixtures as a Possible Source of Oxygen and Chlorine Detected by the Sample Analysis at Mars (SAM) Instrument in Gale Crater, Mars

The Sample Analysis at Mars (SAM) instrument onboard the Curiosity rover detect-ed O2 and HCl gas releases from the Rocknest (RN) eolian bedform and the John Klein (JK) and Cumber-land (CB) drill hole materials in Gale Crater (Fig. 1) [1,2]. Chlorinated hydrocarbons have also been detect-ed by the SAM quadrupole mass spectrometer (QMS) and gas chromatography/mass spectrometer (GCMS) [1,2,3,4]. These detections along with the detection of perchlorate (ClO4(-)) by the Mars Phoenix Lander's Wet Chemistry Laboratory (WCL) [5] suggesting perchlo-rate is a possible candidate for evolved O2 and chlorine species. Laboratory thermal analysis of individual per-chlorates has yet to provide an unequivocal tempera-ture match to the SAM O2 and HCl release data [1,2]. Catalytic reactions of Fe phases in the Gale Crater ma-terial with perchlorates can potentially reduce the de-composition temperatures of these otherwise pure per-chlorate/chlorate phases [e.g., 6,7]. Iron mineralogy found in the Rocknest materials when mixed with Ca-perchlorate was found to cause O2 release temperatures to be closer match to the SAM O2 release data and enhance HCl gas releases. Exact matches to the SAM data has unfortnunately not been achieved with Ca-perchlorate-Fe-phase mixtures [8]. The effects of Fe-phases on magnesium perchlorate thermal decomposi-tion release of O2 and HCl have not been evaluated and may provide improved matches to the SAM O2 and HCl release data. This work will evaluate the thermal decomposition of magnesium perchlorate mixed with fayalite/magnetite phase and a Mauna Kea palagonite (HWMK 919). The objectives are to 1) summarize O2 and HCl releases from the Gale Crater materials, and 2) evaluate the O2 and HCl releases from the Mg-perchlorate + Fe phase mixtures to determine if Mg-perchlorate mixed with Fe-phases can explain the Gale Crater O2 and HCl releases.

Sutter, B.↗

Modification of conventional peak shapes to accurately represent spectral asymmetry: High-Resolution X-ray photoelectron spectra of [C 4 C 1 Pyrr][NTf 2 ] and [C 8 C 1 Im][NTf 2 ] ionic liquids

X-ray photoelectron spectroscopy (XPS) is one of the most widely used techniques for surface characterization. Analysis of XPS data is challenging and requires the analyst to fit the data with synthetic line shapes to reach physically meaningful interpretations. Experimental spectral envelopes, however, are complex and display asymmetric features that are often ignored or attributed to additional chemical components. The high-resolution XPS spectra of [C 4 C 1 Pyrr][NTf 2 ] and [C 8 C 1 Im][NTf 2 ] all exhibit a degree of asymmetry which is systematically observed at the higher binding energy side of photoemission envelopes. Here, we present the development of a refined fitting procedure for XPS spectra of these ionic liquid-based systems which include (a) Shirley background offset necessary to account for the insulator-like region and (b) spectral asymmetry in C 1s and N 1s regions. Further, Shirley and trapezoid components are applied to compensate for inelastic scattering taking place during electron transitions as high as 7.8 eV above the start of the fitting region in C 1s high-resolution spectrum. To demonstrate the fitness of this model, we present an analysis of a 2:1 mixture of [C 4 C 1 Pyrr][NTf 2 ]: [C 8 C 1 Im][NTf 2 ].

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Utilizing metal cation reactions with carbonyl sulfide to remove isobaric interferences in tandem inductively coupled plasma mass spectrometry analyses

Carbonyl sulfide (OCS) was used as a reaction gas to investigate gas phase metal (M + ) ion-molecule reactions using the Agilent 8900 inductively coupled plasma tandem mass spectrometer (ICP-MS/MS) to yield insight on how this gas may be used to remove isobaric interferences in analytical measurements. The experimental work was paired with density functional theory (DFT) calculations of the reaction enthalpy to predict whether M + will react with OCS. A multi-element standard containing 46 elements ranging from 9 to 208 u was analyzed in the presence and absence of OCS. When a reaction was observed, the dominant product was the sulfide (MS + ). Oxide products were also observed for many M + but formation was less efficient with OCS than previously observed with other reaction gases. This is likely due to the weaker OC-S bond that makes MS + formation more favorable. Increasing the flow rate from 0.1 to 0.2 mL/min (corresponding to a change in reaction gas pressure from 0.35 to 0.53 Pa (2.6 to 4.0 mTorr)) generally resulted in greater MS + production, including the secondary product MS 2 + for a few cations. The early lanthanide series ions (La + , Ce + , Pr + and Nd + ) produced greater quantities of MO + at the higher pressure, although MS + products were still the dominant product. The DFT-predicted reaction enthalpies were consistent with the observed sulfide formation, with an accuracy >90%; however, model predictions were less accurate for the minor and higher order products (< 77% for MO + ). Finally, the work presented here continues a systematic study of ion-molecule reactions in ICP-MS/MS to understand and develop new and novel ways to analyze complex mixtures with minimal pre-analysis treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tracking atomic structure evolution during directed electron beam induced Si-atom motion in graphene via deep machine learning

Using electron beam manipulation, we enable deterministic motion of individual Si atoms in graphene along predefined trajectories. Structural evolution during the dopant motion was explored, providing information on changes of the Si atom neighborhood during atomic motion and providing statistical information of possible defect configurations. The combination of a Gaussian mixture model and principal component analysis applied to the deep learning-processed experimental data allowed disentangling of the atomic distortions for two different graphene sublattices. This approach demonstrates the potential of e-beam manipulation to create defect libraries of multiple realizations of the same defect and explore the potential of symmetry breaking physics. The rapid image analytics enabled via a deep learning network further empowers instrumentation for e-beam controlled atom-by-atom fabrication. Here, the analysis described in the paper can be reproduced via an interactive Jupyter notebook at https://git.io/JJ3Bx.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flow-based likelihoods for non-Gaussian inference

We investigate the use of data-driven likelihoods to bypass a key assumption made in many scientific analyses, which is that the true likelihood of the data is Gaussian. In particular, we suggest using the optimization targets of flow-based generative models, a class of models that can capture complex distributions by transforming a simple base distribution through layers of nonlinearities. We call these flow-based likelihoods (FBL). We analyze the accuracy and precision of the reconstructed likelihoods on mock Gaussian data, and show that simply gauging the quality of samples drawn from the trained model is not a sufficient indicator that the true likelihood has been learned. We nevertheless demonstrate that the likelihood can be reconstructed to a precision equal to that of sampling error due to a finite sample size. We then apply FBLs to mock weak lensing convergence power spectra, a cosmological observable that is significantly non-Gaussian (NG). We find that the FBL captures the NG signatures in the data extremely well, while other commonly used data-driven likelihoods, such as Gaussian mixture models and independent component analysis, fail to do so. This suggests that works that have found small posterior shifts in NG data with data-driven likelihoods such as these could be underestimating the impact of non-Gaussianity in parameter constraints. By introducing a suite of tests that can capture different levels of NG in the data, we show that the success or failure of traditional data-driven likelihoods can be tied back to the structure of the NG in the data. Here, unlike other methods, the flexibility of the FBL makes it successful at tackling different types of NG simultaneously. Because of this, and consequently their likely applicability across datasets and domains, we encourage their use for inference when sufficient mock data are available for training.

79 ASTRONOMY AND ASTROPHYSICS↗

A study for hypergolic vapor sensor development

The use of an electrochemical technique for MMH and N02 measurement was investigated. Specific MMH and N02 electrochemical sensors were developed. Experimental techniques for preparation, handling, and analysis of hydrazine's vapor mixtures at ppb and ppm levels were developed. Two approaches to N02 instrument design were evaluated including specific adsorption and specific electrochemical reduction. Two approaches to hydrazines monitoring were evaluated including catalytic conversion to N0 with subsequent N0 detection and direct specific electrochemical oxidation. Two engineering prototype MMH/N02 monitors were designed and constructed.

Stetter, J. R.↗

Theoretical and experimental separation dynamics in capillary zone electrophoresis

The mathematical model of Bier et al. (1983) is used in a computer aided analysis of the conditions in capillary zone electrophoresis (ZE) under which sample zones migrate noninteractively with the carrier electrolyte. The monitoring of sample zones with a capillary analyzer that features both on-line conductivity and UV detection at the end of the separation trough is discussed. Data from a ZE analysis of a 5-component mixture are presented, and it is noted that all five components can be monitored via their conductivity change if enough sample is present. It is suggested from the results that the concentration ratio of background buffer to sample should be a minimum of 100:1 to effectively apply the plate concept to ZE.

Thormann, Wolfgang↗