Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “miniature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Implementation of Precursor and Neutral Loss Scans on a Miniature Ion Trap Mass Spectrometer and Performance Comparison to a Benchtop Linear Ion Trap

Implementation of orthogonal double resonance precursor and neutral loss scans on the Mini 12 miniature rectilinear ion trap mass spectrometer is described, and performance is compared to that of a commercial Thermo linear trap quadropole (LTQ) linear ion trap. The ac frequency scan version of the technique at constant rf voltage is used here because it is operationally much simpler to implement. Remarkably, the Mini 12 shows up to two orders of magnitude higher sensitivity compared to that of the LTQ. Resolution on the LTQ is better than unit at scan speeds of ~ 400 Th/s, whereas peak widths on the Mini 12, on average, range from 0.5 to 2.0 Th full width at half maximum and depend heavily on the precursor ion Mathieu q parameter as well as the pump down time that precedes the mass scan. Both sensitivity and resolution are maximized under higher pressure conditions (short pump down time) on the Mini 12. The effective mass range of the product ion ejection waveform was found to be 5.8 Th on the Mini 12 in the precursor ion scan mode vs. that of 3.9 Th on the LTQ. In the neutral loss scan mode, the product ion selectivity was between 8 and 11 Th on the Mini 12 and between 7 and 8 Th on the LTQ. The effects of nonlinear resonance lines on the Mini 12 were also explored. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nezha, a novel active miniature inverted-repeat transposable element in cyanobacteria

Miniature inverted-repeat transposable elements (MITEs) were first identified in plants and exerted extensive proliferations throughout eukaryotic and archaeal genomes. But very few MITEs have been characterized in bacteria. We identified a novel MITE, called Nezha, in cyanobacteria Anabaena variabilis ATCC 29413 and Nostoc sp. PCC 7120. Nezha, like most previously known MITEs in other organisms, is small in size, non-coding, carrying TIR and DR signals, and of potential to form a stable RNA secondary structure, and it tends to insert into A+T-rich regions. Recent transpositions of Nezha were observed in A. variabilis ATCC 29413 and Nostoc sp. PCC 7120, respectively. Nezha might have proliferated recently with aid from the transposase encoded by ISNpu3-like elements. A possible horizontal transfer event of Nezha from cyanobacteria to Polaromonas JS666 is also observed.

60 APPLIED LIFE SCIENCES↗

Operation characteristics of cylindrical miniature grooved heat pipe using aqueous CuO nanofluids

An experimental study was performed to investigate the operation characteristics of a cylindrical miniature grooved heat pipe using aqueous CuO nanofluid as the working fluid at some steady cooling conditions. The experiments were carried out under both the steady operation process and the unsteady startup process. The experiment results show that substituting the nanofluid for water as the working fluid can apparently improve the thermal performance of the heat pipe for steady operation. The total heat resistance and the maximum heat removal capacity of the heat pipe using nanofluids can maximally reduce by 50% and increase by 40% compared with that of the heat pipe using water, respectively. For unsteady startup process, substituting the nanofluid for water as the working fluid, cannot only improve the thermal performance, but also reduce significantly the startup time. (author)

42 ENGINEERING↗

Miniature bulge test and energy release rate in HIPed aluminum/aluminum interfacial fracture

We summarize the development of a technique of using miniature bulge test combined with three-dimensional digital image correlation (3D-DIC) for measuring energy release rate or fracture toughness of bimaterial interface of thin metal foils. Furthermore, the energy release rate associated with the HIPed aluminum/aluminum interfacial delamination is determined experimentally using the proposed technique. Detailed discussions of the schemes of preparing and conducting the bulge test, and computing various quantities required for the determination of the energy release rate are presented.

36 MATERIALS SCIENCE↗

Separate effects irradiation testing of miniature fuel specimens

We report that qualification of new nuclear fuels is necessary for their deployment and requires a thorough understanding of fuel behavior under irradiation. Traditionally, nuclear fuels have been qualified by performing exhaustive integral tests under a limited range of prototypic conditions designed for their specific reactor application. While some integral fuel testing is essential, basic data on behavior and property evolution under irradiation can be obtained from separate effects tests. These irradiations could offer reduced cost, reduced complexity, and in the case of accelerated testing, reduced time to achieve a given burnup. Furthermore, it may be desirable to design test irradiations capable of deconvoluting the myriad effects of burnup, temperature gradients, and other factors inherent to integral irradiation tests. Oak Ridge National Laboratory has developed an experimental capability to perform separate effects irradiation testing of miniature fuel specimens in the High Flux Isotope Reactor (HFIR): the “MiniFuel” irradiation vehicle. The small size (<4 mm 3 ) of the fuel specimens simplifies the design, analysis, and post-irradiation examination. By reducing the fuel mass, the total heat generated inside the experiment vehicle can be dominated by gamma heating in the structural materials instead of fission heating in the fuel. This essentially decouples the fuel temperature from the fission rate, allowing for highly accelerated testing (3X-18X the burnup rate of a typical light water reactor for 235 U enrichments varying from 0.22 wt% to 8 wt%) and an extremely flexible experiment design that can accommodate a wide range of fuel temperatures (~100 °C to >1200 °C), compositions, enrichments, and even geometries without requiring detailed analyses for each fuel variant. In conclusion, this paper summarizes the experiment design concept, evaluates potential applications for specific fuel forms, and briefly describes the first set of experiments on uranium nitride kernels that have been assembled and are currently being irradiated in the HFIR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Commissioning a Miniature Multileaf Collimator for Small Field Radiotherapy

The aim of this study was to determine dosimetric data for the Siemens ModuLeaf miniature multileaf collimator. Acquiring accurate data for small fields requires careful evaluation of different measurement techniques and dosimeters. Output factors were measured using several different detectors. Comparing these results demonstrated the relative under-response of the devices as the field size approaches the active area of the detector. Measurements obtained with a diamond detector, radiographic film, 0.125 cm{sup 3} cylindrical and advanced Markus ionization chambers agreed (within 0.7%) down to a field size of 2 x 2 cm. For smaller field sizes, only the diamond detector and the film agreed within their relative uncertainties. Head scatter factors were measured in brass and Perspex miniphantoms using the cylindrical chamber positioned at the isocenter, and in the Perspex miniphantom at extended distances. For field sizes of less than 3 x 3 cm, only the measurements with the brass miniphantom at the isocenter and the Perspex miniphantom at extended distances agreed (within 0.8%). The effect on the miniphantom measurements of using a low scatter support stand was also quantified. Beam profiles were measured using radiographic film. An unexpected artifact was found in these images because of increased backscatter from white lines inscribed and painted on the phantom. Percentage depth doses (PDDs) measured with and without the ModuLeaf attached agreed for all field sizes down to 3 x 3 cm. Below this field size, tissue maximum ratios (TMRs) were measured using an advanced Markus chamber. The 3 x 3 cm ModuLeaf TMR data agreed with the non-ModuLeaf PDD data within their relative uncertainties. This study investigated the use of several different measurement methods from which accurate dosimetric parameters can be obtained without the need to acquire specialist detectors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation-hard miniature optical engine with high bandwidth

Future silicon trackers will be operated in an intense radiation environment and require large volumes of data to be transmitted off detector. In addition, the optical modules must be of low mass in order to limit multiple scattering and nuclear interactions that would degrade the overall performance of the detector. Here, we present a miniature optical engine that satisfies these constraints. The optical engine consists of an ASIC driving a VCSEL (Vertical Cavity Surface Emitting Laser) array in an optical package. Two ASICs are designed to operate a 12-channel VCSEL array at 1.28 or 5.12 Gb/s per channel, which yields a total data rate of up to 60 Gb/s. The core transistors are fabricated in a 65 nm CMOS process which enhance the radiation-hardness. Each channel contains equalizer (CTLE) and clock-data recovery circuits (CDR) so that the ASIC can restore the highly distorted electrical signal after propagating through several meters of cables of small diameter. The equalizer, CDR, and VCSEL driver are configured via a digital I 2 C chip interface with triple redundant memory to mitigate single event upset (SEU) effects. The bias and modulation currents are controlled by a digital-to-analog converter (DAC). We present the design of the circuit together with the results of the simulations and preliminary measurements.

47 OTHER INSTRUMENTATION↗

A high-precision miniaturized rotating coil transducer for magnetic measurements

A miniaturized Printed Circuit Board (PCB) sensing coil, jointly developed by CERN and Fermilab for measuring the field of small-gap (less than 10 mm) accelerator magnets, is illustrated. A sensing coil array, with a scheme for compensating the main field when measuring the harmonic error components, hosted on a synthetic sapphire-based transducer, is presented. Key innovating features are (i) very-small size, both for the sensing coil array (thickness of 1.380 mm) and for the transducer (overall diameter of 7.350 mm), (ii) metrological performance, namely accuracy (more than five times better than state of the art), and 1-sigma repeatability (ten times better on harmonics with amplitude less than 100 ppm), and (iii) manufacturing technology of both the coil array (13 double layers aligned within 10 μm), and the sapphire support (concentricity, the most important uncertainty source for rotating coils, 3 μm of uncertainty, namely one order of magnitude better than fiberglass support). After stating the measurement problem, the design of the transducer and a case study of a two-layer PCB sensor array are also illustrated. Then, the prototyping and quality control of both the sensor and the transducer are discussed. Furthermore, the calibration and the results obtained with a prototype setup at Fermilab are presented. Finally, in the appendix, the theory of the rotating coil, the sensor geometry, and the harmonic compensation are briefly reviewed for the reader easiness.

06.20.fb/calibration↗

Miniaturized electroosmotic pump capable of generating pressures of more than 1200 bar

Here, the pressure output of a pump cannot be increased simply by connecting several of them in series. This barrier is eliminated with the micropump developed in this work. The pump is actually an assembly of a number of fundamental pump units connected in series. The maximum pressure output of this pump assembly is directly proportional to the number of serially connected pump units. Theoretically, one can always enhance the pressure output by adding more pump units in the assembly, but in reality the upper pressure is constrained by the microtees or microunions joining the pump components. With commercially available microtees and microunions, pressures of more than 1200 bar have been achieved. We have recently experimented using open capillaries to build this pump, but many capillaries have to be utilized in parallel to produce an adequate flow to drive HPLC separations. In this paper, we synthesize polymer monoliths inside 75 μm i.d. capillaries, use these monoliths to assemble miniaturized pumps, characterize the performance of these pumps, and employ these pumps for HPLC separations of intact proteins. By tuning the experimental parameters for monolith preparations, we obtain both negatively and positively charged submicrometer capillary channels conveniently. Each monolith in a 75 μm i.d. capillary is equivalent to several thousands of open capillaries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing Combustion Chemistry in a Miniature Shock Tube with Synchrotron VUV Photo Ionization Mass Spectrometry

Tunable synchrotron-sourced photoionization time-of-flight mass spectrometry (PI-TOF-MS) is an important technique in combustion chemistry, complementing lab-scale electron impact and laser photoionization studies for a wide variety of reactors, typically at low pressure. For high-temperature and high-pressure chemical kinetics studies, the shock tube is the reactor of choice. Extending the benefits of shock tube/TOF-MS research to include synchrotron sourced PI-TOF-MS required a radical reconception of the shock tube. An automated, miniature, high-repetition-rate shock tube was developed and can be used to study high-pressure reactive systems (T > 600 K, P < 100 bar) behind reflected shock waves. In this paper, we present results of a PI-TOF-MS study at the Advanced Light Source at Lawrence Berkeley National Laboratory. Dimethyl ether pyrolysis (2% CH3OCH3/Ar) was observed behind the reflected shock (1400 < T-5 < 1700 K, 3 < P-5 < 16 bar) with ionization energies between 10 and 13 eV. Individual experiments have extremely low signal levels. However, product species and radical intermediates are well-resolved when averaging over hundreds of shots, which is ordinarily impractical in conventional shock tube studies. The signal levels attained and data throughput rates with this technique are comparable to those with other synchrotron-based PI-TOF-MS reactors, and it is anticipated that this high pressure technique will greatly complement those lower pressure techniques.

Lynch, Patrick T.↗

Miniature optical planar camera based on a wide-angle metasurface doublet corrected for monochromatic aberrations

Optical metasurfaces are two-dimensional arrays of nano-scatterers that modify optical wavefronts at subwavelength spatial resolution. They are poised to revolutionize optics by enabling complex low-cost systems where multiple metasurfaces are lithographically stacked and integrated with electronics. For imaging applications, metasurface stacks can perform sophisticated image corrections and can be directly integrated with image sensors. Here we demonstrate this concept with a miniature flat camera integrating a monolithic metasurface lens doublet corrected for monochromatic aberrations, and an image sensor. The doublet lens, which acts as a fisheye photographic objective, has a small f-number of 0.9, an angle-of-view larger than 60° × 60°, and operates at 850 nm wavelength with 70% focusing efficiency. The camera exhibits nearly diffraction-limited image quality, which indicates the potential of this technology in the development of optical systems for microscopy, photography, and computer vision.

47 OTHER INSTRUMENTATION↗

Miniature fluorescence sensor for quantitative detection of brain tumour

Fluorescence-guided surgery has emerged as a vital tool for tumour resection procedures. As well as intraoperative tumour visualisation, 5-ALA-induced PpIX provides an avenue for quantitative tumour identification based on ratiometric fluorescence measurement. To this end, fluorescence imaging and fibre-based probes have enabled more precise demarcation between the cancerous and healthy tissues. These sensing approaches, which rely on collecting the fluorescence light from the tumour resection site and its “remote” spectral sensing, introduce challenges associated with optical losses. In this work, we demonstrate the viability of tumour detection at the resection site using a miniature fluorescence measurement system. Unlike the current bulky systems, which necessitate remote measurement, we have adopted a millimetre-sized spectral sensor chip for quantitative fluorescence measurements. A reliable measurement at the resection site requires a stable optical window between the tissue and the optoelectronic system. This is achieved using an antifouling diamond window, which provides stable optical transparency. The system achieved a sensitivity of 92.3% and specificity of 98.3% in detecting a surrogate tumour at a resolution of 1 × 1 mm 2 . In conclusion, as well as addressing losses associated with collecting and coupling fluorescence light in the current ‘remote’ sensing approaches, the small size of the system introduced in this work paves the way for its direct integration with the tumour resection tools with the aim of more accurate interoperative tumour identification.

59 BASIC BIOLOGICAL SCIENCES↗

Order of magnitude enhancement in x-ray yield at low pressure deuterium-krypton admixture operation in miniature plasma focus device

In a 200 J fast miniature plasma focus device about 17- and 10-fold increase in x-ray yield in spectral ranges of 0.9-1.6 keV and 3.2-7.7 keV, respectively, have been obtained with deuterium-krypton (D{sub 2}-Kr) admixture at operating pressures of {<=}0.4 mbar. In the pressure range of >0.4-1.4 mbar, about twofold magnification in average x-ray yield along with broadening of optimum pressure range in both spectral ranges were obtained for D{sub 2}-Kr admixtures. An order of magnitude enhancement in x-ray yields at low pressures for admixture operation will help in achieving high performance device efficiency for lithography and micromachining applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Order of magnitude enhancement in neutron emission with deuterium-krypton admixture operation in miniature plasma focus device

The effect of varied concentrations of deuterium-krypton (D{sub 2}-Kr) admixture on the neutron emission of a fast miniature plasma focus device was investigated. It was found that a judicious concentration of Kr in D{sub 2} can significantly enhance the neutron yield. The maximum average neutron yield of (1{+-}0.27)x10{sup 4} n/shot for pure D{sub 2} filling at 3 mbars was enhanced to (3.14{+-}0.4)x10{sup 5} n/shot with D{sub 2}+2% Kr admixture operation, which represents a >30-fold increase. More than an order of magnitude enhancement in the average neutron yield was observed over the broader operating range of 1-4 mbars for D{sub 2}+2% Kr and D{sub 2}+5% Kr admixtures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a compact electron ion coincidence analyzer using a coaxially symmetric mirror electron energy analyzer and a miniature polar-angle-resolved time-of-flight ion mass spectrometer with four concentric anodes

A compact electron ion coincidence (EICO) analyzer that uses a coaxially symmetric mirror electron energy analyzer and a miniature polar-angle-resolved time-of-flight ion mass spectrometer with four concentric anodes was developed for surface science and surface analysis. The apparatus is especially useful in the study of ion desorption stimulated by an Auger process because information on the mass, yield, desorption polar angle, and kinetic energy of ions can be obtained for the selected core-ionization-final-states or the selected Auger-final-states. The analyzer can be used also for analysis of the configuration of specific surface molecules because the desorption polar angles reflect the direction of surface bonds. The EICO analyzer was evaluated by measuring polar-angle-resolved-ion yield spectra and coincidence spectra of Auger-electron and polar-angle-resolved H{sup +} from condensed water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Development of a Miniature Neutron Generator for the Brachytherapy Treatment of Cancer

Brachytherapy refers to application of an irradiation source within a tumor. {sup 252}Cf needles used in brachytherapy have been successfully applied to treatment of some of the most virulent cancers but it is doubtful that it will be widely used because of difficulty in dealing with unwanted dose (source cannot be turned off) and in adhering to stringent NRC regulations that have been exacerbated in our post 911 environment. We have been working on the development of a miniature neutron generator with the reaction target placed at the end of a needle (tube) for brachytherapy applications. Orifice geometries are most amenable, e.g. rectum and cervix, but interstitial use is possible with microsurgery. This paper dicusses the results of a 30 watt DD neutron generator SBU project that demonstrates that sufficient hydrogen isotope current can be delivered down a small diameter needle required for a DT neutron treatment device, and, will summarize the progress of building a commercial device pursued by the All Russian Institute for Automatics (VNIIA) supported by the DOE's Industrial Proliferation Prevention Program (IPP). It is known that most of the fast neutron (FN) beam cancer treatment facilities have been closed down. It appears that the major limitation in the use of FN beams has been damage to healthy tissue, which is relatively insensitive to photons, but this problem is alleviated by brachytherapy. Moreover, recent clinical results indicate that fast neutrons in the boost mode are most highly effective in treating large, hypoxic, and rapidly repopulating diseases. It appears that early boost application of FN may halt angiogenesis (development and repair of tumor vascular system) and shrink the tumor resulting in lower hypoxia. The boost brachytherapy application of a small, low cost neutron generator holds promise of significant contribution to the treatment of cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two-dimensional particle-in-cell Monte Carlo simulation of a miniature inductively coupled plasma source

Two-dimensional axisymmetric particle-in-cell simulations with Monte Carlo collision calculations (PIC-MCC) have been conducted to investigate argon microplasma characteristics of a miniature inductively coupled plasma source with a 5-mm-diameter planar coil, where the radius and length are 5 mm and 6 mm, respectively. Coupling the rf-electromagnetic fields to the plasma is carried out based on a collisional model and a kinetic model. The former employs the cold-electron approximation and the latter incorporates warm-electron effects. The numerical analysis has been performed for pressures in the range 370-770 mTorr and at 450 MHz rf powers below 3.5 W, and then the PIC-MCC results are compared with available experimental data and fluid simulation results. The results show that a considerably thick sheath structure can be seen compared with the plasma reactor size and the electron energy distribution is non-Maxwellian over the entire plasma region. As a result, the distribution of the electron temperature is quite different from that obtained in the fluid model. The electron temperature as a function of rf power is in a reasonable agreement with experimental data. The pressure dependence of the plasma density shows different tendency between the collisional and kinetic model, implying noncollisional effects even at high pressures due to the high rf frequency, where the electron collision frequency is less than the rf driving frequency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The depolarization of Pb(Zr{sub 0.52}Ti{sub 0.48})O{sub 3} ferroelectrics by cylindrical radially expanding shock waves and its utilization for miniature pulsed power

The effects of depolarization of Pb(Zr{sub 0.52}Ti{sub 0.48})O{sub 3} (PZT 52/48) poled ferroelectrics by cylindrical radially expanding shock waves propagated along and across the polarization vector P{sub 0} were experimentally detected. Miniature (total volume 100 cm{sup 3}) autonomous generators based on these effects were capable of producing output voltage pulses with amplitudes up to 25 kV and output energies exceeding 1 J.

36 MATERIALS SCIENCE↗