Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “micro”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Applications of synchrotron-based micro-imaging techniques for the analysis of Cultural Heritage materials

The analysis of cultural Heritage objects is often technically challenging. When analyzing micro-fragments, the amount of matter is usually very tiny, hence requiring sensitive techniques. These samples, in particular painting fragments, may present multi-layered structures, with layer thickness of {approx}10 {mu}m. It leads to favor micro-imaging techniques, with a good lateral resolution (about one micrometer), that manage the discriminative study of each layer. Besides, samples are usually very complex in term of chemistry, as they are made of mineral and organic matters, amorphous and crystallized phases, major and minor elements. Accordingly, a multi-modal approach is generally essential to solve the chemical complexity of such hybrid materials. Different examples will be given, to illustrate the various possibilities of synchrotron-based micro-imaging techniques, such as micro X-ray diffraction, micro X-ray fluorescence, micro X-ray absorption spectroscopy and micro FTIR spectroscopy. Focus will be made on paintings, but the whole range of museum objects (going from soft matter like paper or wood to hard matter like metal and glass) will be also considered.

36 MATERIALS SCIENCE↗

Suppression of secondary electron yield by micro-porous array structure

We study secondary electron yield (SEY) suppression for metal materials using a roughened surface with a micro-porous array. First, we perform a Monte Carlo simulation of the electron trajectory in a single cylindrical well using a phenomenological model of secondary electron emission and the SEY suppression efficiency of a micro-porous array. The simulation results show that the SEY of a roughened surface is affected significantly by the aspect ratio of the micro-pores and the surface porosity of the metal plate. Then, to verify the simulation results, we produce a micro-porous array on metal plates using photolithography and measure their SEYs. We show that the micro-porous array structure can efficiently suppress the SEY of metal materials, and the measurements agree quantitatively with the corresponding simulation results. Finally, we derive an analytical formula to evaluate easily the SEY suppression efficiency of the Ag micro-porous array. In total, the micro-porous array proposed in this paper offers an alternative to SEY suppression in related areas such as multipactor effects in satellite payloads or electron cloud effects in accelerators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Growth and characterizations of GaN micro-rods on graphene films for flexible light emitting diodes

We report the growth of GaN micro-rods and coaxial quantum-well heterostructures on graphene films, together with structural and optical characterization, for applications in flexible optical devices. Graphene films were grown on Cu foil by means of chemical vapor deposition, and used as the substrates for the growth of the GaN micro-rods, which were subsequently transferred onto SiO{sub 2}/Si substrates. Highly Si-doped, n-type GaN micro-rods were grown on the graphene films using metal–organic chemical vapor deposition. The growth and vertical alignment of the GaN micro-rods, which is a critical factor for the fabrication of high-performance light-emitting diodes (LEDs), were characterized using electron microscopy and X-ray diffraction. The GaN micro-rods exhibited promising photoluminescence characteristics for optoelectronic device applications, including room-temperature stimulated emission. To fabricate flexible LEDs, In{sub x}Ga{sub 1–x}N/GaN multiple quantum wells and a p-type GaN layer were deposited coaxially on the GaN micro-rods, and transferred onto Ag-coated polymer substrates using lift-off. Ti/Au and Ni/Au metal layers were formed to provide electrical contacts to the n-type and p-type GaN regions, respectively. The micro-rod LEDs exhibited intense emission of visible light, even after transfer onto the flexible polymer substrate, and reliable operation was achieved following numerous cycles of mechanical deformation.

36 MATERIALS SCIENCE↗

Site-specific Pt Deposition and Etching on Electrically and Thermally Isolated SiO2 Micro-disk Surfaces

Electrically and thermally isolated surfaces are often crucial for improving the detection sensitivity of microelectronic sensors. The site specific in-situ growth of Pt nano-rods on thermally and electrically isolated micro-fabricated SiO2 disks using wet chemical etching and focused ion/electron dual-beam (FIB-SEM) is demonstrated in this work. Fabrication of an array of micro-cavities on top of micro-disk is also demonstrated. FIB source is also utilized to fabricate through-holes in the micro-disks. The nature of Ga Gaussian distribution in the Ga-implanted region using a FIB source can naturally create more conducting layer on the sidewalls of through-holes on the micro-disks. Some sensor design concepts based on micro-fabrication of SiO2 micro-disks utilizing thermally and electrically isolated surfaces are discussed from the viewpoint of applications in photonics and bio-sensing.

Saraf, Laxmikant V↗

Mini-beam collimator enables micro-crystallography experiments on standard beamlines.

The high-brilliance X-ray beams from undulator sources at third-generation synchrotron facilities are excellent tools for solving crystal structures of important and challenging biological macromolecules and complexes. However, many of the most important structural targets yield crystals that are too small or too inhomogeneous for a 'standard' beam from an undulator source, 25-50 {micro}m (FWHM) in the vertical and 50-100 {micro}m in the horizontal direction. Although many synchrotron facilities have microfocus beamlines for other applications, this capability for macromolecular crystallography was pioneered at ID-13 of the ESRF. The National Institute of General Medical Sciences and National Cancer Institute Collaborative Access Team (GM/CA-CAT) dual canted undulator beamlines at the APS deliver high-intensity focused beams with a minimum focal size of 20 {micro}m x 65 {micro}m at the sample position. To meet growing user demand for beams to study samples of 10 {micro}m or less, a 'mini-beam' apparatus was developed that conditions the focused beam to either 5 {micro}m or 10 {micro}m (FWHM) diameter with high intensity. The mini-beam has a symmetric Gaussian shape in both the horizontal and vertical directions, and reduces the vertical divergence of the focused beam by 25%. Significant reduction in background was achieved by implementation of both forward- and back-scatter guards. A unique triple-collimator apparatus, which has been in routine use on both undulator beamlines since February 2008, allows users to rapidly interchange the focused beam and conditioned mini-beams of two sizes with a single mouse click. The device and the beam are stable over many hours of routine operation. The rapid-exchange capability has greatly facilitated sample screening and resulted in several structures that could not have been obtained with the larger focused beam.

36 MATERIALS SCIENCE↗

High-resolution helical cone-beam micro-CT with theoretically-exact reconstruction from experimental data

Purpose: In this paper we show that optimization-based autofocus may be used to overcome the instabilities that have, until now, made high-resolution theoretically-exact tomographic reconstruction impractical. To our knowledge, this represents the first successful use of theoretically-exact reconstruction in helical micro computed tomography (micro-CT) imaging. We show that autofocus-corrected, theoretically-exact helical CT is a viable option for high-resolution micro-CT imaging at high cone-angles ({approx}50 deg.). The elevated cone-angle enables better utilization of the available X-ray flux and therefore shorter image acquisition time than conventional micro-CT systems. Methods: By using the theoretically-exact Katsevich 1PI inversion formula, we are not restricted to a low-cone-angle regime; we can in theory obtain artefact-free reconstructions from projection data acquired at arbitrary high cone-angles. However, this reconstruction method is sensitive to misalignments in the tomographic data, which result in geometric distortion and streaking artefacts. We use a parametric model to quantify the deviation between the actual acquisition trajectory and an ideal helix, and use an autofocus method to estimate the relevant parameters. We define optimal units for each parameter, and use these to ensure consistent alignment accuracy across different cone-angles and different magnification factors. The tomographic image is obtained from a set of virtual projections in which software correction for hardware misalignment has been applied. Results: We make significant modifications to the autofocus method that allow this method to be used in helical micro-CT reconstruction, and show that these developments enable theoretically-exact reconstruction from experimental data using the Katsevich 1PI (K1PI) inversion formula. We further demonstrate how autofocus-corrected, theoretically-exact helical CT reduces the image acquisition time by an order of magnitude compared to conventional circular scan micro-CT. Conclusions: Autofocus-corrected, theoretically-exact cone-beam reconstruction is a viable option for reducing acquisition time in high-resolution micro-CT imaging. It also opens up the possibility of efficiently imaging long objects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Micro Combined Heat and Power Device

U.S. buildings account for approximately 40% of total U.S. energy consumption and 75% of electricity use, emphasizing the need for efficient, resilient, and secure energy solutions. Micro-combined heat and power (micro-CHP) systems provide an effective approach by simultaneously generating electricity and recovering waste heat for thermal use. However, current commercial micro-CHPs face challenges in achieving higher efficiency, lower emissions, and reduced cost. To address these limitations, a novel micro-CHP prototype powered by a unique opposed-piston four-stroke (OP4S) engine was developed. The OP4S features a simplified, low-cost design with reduced heat losses and dual-piston operation that enables higher thermal efficiency. Experimental results demonstrated up to 35.2% AC electrical efficiency under lean combustion, surpassing the best-performing ICE-based micro-CHPs reported publicly. In addition, the micro-CHP enables a total CHP efficiency exceeding 93%. The prototype operates reliably for over 600 hours, providing flexible and efficient thermal and electrical outputs. This novel OP4S-based micro-CHP offers a resilient, low-cost, and energy-efficient solution suitable for residential, light commercial, and remote community applications across diverse climate zones.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Productive Use of Energy in African Micro-Grids: Technical and Business Considerations

Demand for electricity from small industry and businesses, which is defined as the productive use of energy (PUE), is a key success factor for micro-grids. Because of the typically low energy usage of residential customers, without linkage to and support for these energy users, micro-grids are likely to struggle to reach the critical revenue needed for financial viability. This report is a resource entrepreneurs and developers can use to understand the technical and business model challenges related to PUE in smaller micro-grids. It focuses on small agricultural processing, and small industrial and commercial loads. This report examines best practices for promoting PUE and the business models used by developers. It starts with background information and a literature review followed by a discussion of key enterprise considerations for productive use (PU) including: value chain and business case analysis, enterprise development and training, appliance financing, and developers running PU businesses. Unlike many other reports on PUE, this report is based on application specific data. The report is also unique in that it provides actual customer demographics and load profiles. This report considers PUE from both business and technical perspectives, and it considers the interests of both the micro-grid operators and the microenterprises and entrepreneurs they serve. It looks at the service levels required by different PUs and the technical characteristics and challenges of different types of PU equipment. The report also includes examples of business cases for some of the most important PU opportunities, including milling, ice making, carpentry, egg incubation, and water treatment. This report is a resource that entrepreneurs, governments, and non-governmental organizations can use to help design programs to meet their individual goals of PUE in micro-grids and economic development in rural Africa. It can also be used by developers, engineers, and other organizations designing micro-grids to inform their technical and business decisions and to improve system design, reduce risk, and increase success with adding PU loads to both new and existing micro-grids.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MicroED for rapid and comprehensive characterization of the unknown small molecule composition of crude plant and soil extracts

This project implemented at PNNL a method introduced recently for de novo structure elucidation of small organic molecules: Micro-Electron Diffraction (henceforth microED). Micro-ED is an alternative to X-ray diffraction (XRD) or Nuclear Magnetic Resonance (NMR) for atomic-resolution structure elucidation of small organic or biological molecules, and it can succeed in solving structures when these well-established methods fail. In particular, microED offers the possibility of determining structures from far smaller quantities of material than would be required for NMR or even XRD, or from substances that fail to form crystals suitable (i.e., large enough) for X-ray crystallography, because microED requires only microcrystalline samples: in principle, a single crystal with ca. 100 nm dimensions would be suitable. MicroED is performed typically with standard electron microscopy (EM) instrumentation. The substantial potential of microED has drawn significant attention and examples of its use to solve difficult structure elucidation problems where X-ray or NMR methods failed has been described recently.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rechargeable Micro-Batteries

The quest for efficient power sources for small sensors has led to a growing interest in rechargeable micro-batteries, offering the potential to harness energy from various sources for extended periods. This project delves into a multifaceted project aimed at enhancing the performance and viability of rechargeable micro-batteries in this context. The Pacific Northwest National Laboratory (PNNL) has leveraged its expertise in primary micro-battery development, evolving into a software-driven approach for designing cylindrical micro-batteries. This project addresses the cycle life issue through innovative cell design, electrode optimization, and electrolyte refinement. A case study of the MB1842 rechargeable micro-battery demonstrates the promising outcomes of these advancements, showcasing a capacity of 0.32 mAh at ~1C (0.35 mA) and remarkable cycle performance, extending the cycle life to 510-570 cycles at 80% end-of-life (EOL), 710-760 cycles at 70% EOL and 840-940 cycles at 60% EOL, thereby ensuring a service life of 10 years for these rechargeable micro-batteries. This endeavor represents a significant stride towards unlocking the full potential of rechargeable micro-batteries, paving the way for their widespread application in small sensor technologies. The outcome from this project also successfully supports the award of a new project: 80621 - Self-Powered Modular Acoustic Telemetry System with Sensing.

25 ENERGY STORAGE↗

The MICRO-BOSS scheduling system: Current status and future efforts

In this paper, a micro-opportunistic approach to factory scheduling was described that closely monitors the evolution of bottlenecks during the construction of the schedule and continuously redirects search towards the bottleneck that appears to be most critical. This approach differs from earlier opportunistic approaches, as it does not require scheduling large resource subproblems or large job subproblems before revising the current scheduling strategy. This micro-opportunistic approach was implemented in the context of the MICRO-BOSS factory scheduling system. A study comparing MICRO-BOSS against a macro-opportunistic scheduler suggests that the additional flexibility of the micro-opportunistic approach to scheduling generally yields important reductions in both tardiness and inventory. Current research efforts include: adaptation of MICRO-BOSS to deal with sequence-dependent setups and development of micro-opportunistic reactive scheduling techniques that will enable the system to patch the schedule in the presence of contingencies such as machine breakdowns, raw materials arriving late, job cancellations, etc.

Sadeh, Norman M.↗

Micro-Pressure Sensors for Future Mars Missions

The joint research interchange effort was directed at the following principal areas: u further development of NASA-Ames' Mars Micro-meteorology mission concept as a viable NASA space mission especially with regard to the science and instrument specifications u interaction with the flight team from NASA's New Millennium 'Deep-Space 2' (DS-2) mission with regard to selection and design of micro-pressure sensors for Mars u further development of micro-pressure sensors suitable for Mars The research work undertaken in the course of the Joint Research Interchange should be placed in the context of an ongoing planetary exploration objective to characterize the climate system on Mars. In particular, a network of small probes globally-distributed on the surface of the planet has often been cited as the only way to address this particular science goal. A team from NASA Ames has proposed such a mission called the Micrometeorology mission, or 'Micro-met' for short. Surface pressure data are all that are required, in principle, to calculate the Martian atmospheric circulation, provided that simultaneous orbital measurements of the atmosphere are also obtained. Consequently, in the proposed Micro-met mission a large number of landers would measure barometric pressure at various locations around Mars, each equipped with a micro-pressure sensor. Much of the time on the JRI was therefore spent working with the engineers and scientists concerned with Micro-met to develop this particular mission concept into a more realistic proposition.

Catling, David C.↗

A Mars Micro-Meteorological Station Mission

The Mars Micro-Meteorological Station (Micro-Met) Mission is designed to provide the global surface pressure measurements required to help characterize the martian general circulation and climate system. Measurements of surface pressure distributed both spatially and temporally, coupled with simultaneous measurements from orbit, will enable the determination of the general circulation, structure and driving factors of the martian atmosphere as well as the seasonal CO2 cycle. The influence of these atmospheric factors will in turn provide insight into the overall martian climate system. With the science objective defined as the long term (at least one Mars year) globally distributed measurement of surface atmospheric pressure, a straightforward, near term and low cost network mission has been designed. The Micro-Met mission utilizes a unique silicon micro-machined pressure sensor coupled with a robust and lightweight surface station to deliver to Mars 16 Micro-Met stations via a Med-Lite launch vehicle. The battery powered Micro-Met surface stations are designed to autonomously measure, record and transmit the science data via a UHF relay satellite. Entry, descent and landing is provided by an aeroshell with a new lightweight ceramic thermal protection system, a parachute and an impact absorbing structure. The robust lander is capable of surviving the landing loads imposed by the high altitude landing sites required in a global network. By trading the ability to make many measurements at a single site for the ability to make a single measurement at several sites, the Micro-Met mission design satisfies the requirement for truly global meteorological science.

Merrihew, Steven C.↗

Source Term Model for Steady Micro Jets in a Navier-Stokes Computer Code

A source term model for steady micro jets was implemented into a non-proprietary Navier-Stokes computer code, OVERFLOW. The source term models the mass flow and momentum created by a steady blowing micro jet. The model is obtained by adding the momentum and mass flow created by the jet to the Navier-Stokes equations. The model was tested by comparing with data from numerical simulations of a single, steady micro jet on a flat plate in two and three dimensions. The source term model predicted the velocity distribution well compared to the two-dimensional plate using a steady mass flow boundary condition, which was used to simulate a steady micro jet. The model was also compared to two three-dimensional flat plate cases using a steady mass flow boundary condition to simulate a steady micro jet. The three-dimensional comparison included a case with a grid generated to capture the circular shape of the jet and a case without a grid generated for the micro jet. The case without the jet grid mimics the application of the source term. The source term model compared well with both of the three-dimensional cases. Comparisons of velocity distribution were made before and after the jet and Mach and vorticity contours were examined. The source term model allows a researcher to quickly investigate different locations of individual or several steady micro jets. The researcher is able to conduct a preliminary investigation with minimal grid generation and computational time.

Waithe, Kenrick A.↗

Active Fail-Safe Micro-Array Flow Control for Advanced Embedded Propulsion Systems

The primary objective of this research effort was to develop and analytically demonstrate enhanced first generation active "fail-safe" hybrid flow-control techniques to simultaneously manage the boundary layer on the vehicle fore-body and to control the secondary flow generated within modern serpentine or embedded inlet S-duct configurations. The enhanced first-generation technique focused on both micro-vanes and micro-ramps highly-integrated with micro -jets to provide nonlinear augmentation for the "strength' or effectiveness of highly-integrated flow control systems. The study focused on the micro -jet mass flow ratio (Wjet/Waip) range from 0.10 to 0.30 percent and jet total pressure ratios (Pjet/Po) from 1.0 to 3.0. The engine bleed airflow range under study represents about a 10 fold decrease in micro -jet airflow than previously required. Therefore, by pre-conditioning, or injecting a very small amount of high-pressure jet flow into the vortex generated by the micro-vane and/or micro-ramp, active flow control is achieved and substantial augmentation of the controlling flow is realized.

Anderson, Bernhard H.↗

Navigating Team Dynamics: Automated Detection of Micro-Behaviors Between Team Members Through Longitudinal Interaction Data

The success in future long term space exploration missions will depend on the cooperation, coordination, and mutual understanding among the crew members. Micro-behaviors are momentary, subtle linguistic and paralinguistic indicators of thinking and feeling toward another member of the team (Cortina et al., 2001; Smith & Griffiths, 2022) that can significantly impact team dynamics and influence the overall team performance (Paromita & Chaspari, 2024). Due to their interactive nature, micro-behaviors have a sender (i.e., the team member expressing the micro-behavior) and a target (the team member impacted by the micro-behavior). Detection of these behaviors can assist in avoiding possible conflict among crew members and promoting the overall team success. Our prior research focused on an initial proof of concept of machine learning (ML) models and natural language processing (NLP) techniques that were used for automatically detect micro-behaviors among crew members of the US National Aeronautics and Space Administration’s (NASA) Human Exploration Research Analog (HERA) Campaigns 4 and 5 missions (Paromita et al., 2023). Results underscored the importance of incorporating contextual information in the ML models in the form of sentiment analysis, type of task, and dyadic interaction among team members. Here, we expand the scope of our prior work in two ways. First, we assess ML/NLP methods on new behavioral annotations coded using an adapted version of Smith & Griffins (2022) theoretical framework in terms of Violation (i.e., presence of valenced behavior, uplifting/positive or discouraging/negative), Intensity (i.e., force of behavior in terms of how uplifting or discouraging is the behavior), and Intent (i.e., motive of the behavior in terms of whether it was deliberate or unintentional). Second, we expand the design of the ML model to preserve information about the role of each team member within the occurrence of the micro-behavior (in contrast to the previous model that only considered the sender and the target without determining the team member role). This allows to consider all team members' contributions in the conversation and model long-term dependencies in the dialogue. Our experiments for this study are conducted on data from 5 teams of the NASA HERA C4 (NASA grant NNX16AQ48G (PI: Bell)). Conversations were extracted from the 1.5 hour Team Interaction Battery (TIB) task that occurred 5 times in-mission per crew. This resulted in a total of 13,058 conversational turns (i.e., 17.8% uplifting, 3.3% discouraging, 75.76% neutral, 3.14% nulls). Our findings with the revised behavioral coding and ML/NLP models indicate a 43.66% macro F1-score (i.e., 38.29% precision (P), 50.8% recall (R)) for a dialog state-tracking model that includes information from the sender only, and a 40.9% F1-score (i.e., 38.7% P, 43.36% R) for the same model that includes information from both the sender and the target of the micro-behavior. These are significantly higher compared to simple random forest models that classify behaviors strictly based on speech content and do not consider iterative team dynamics, achieving a 36.07% F1-score (i.e., 39.04% R, 33.53% P). Our findings demonstrate potential ways to leverage large conversational datasets to better capture complex team dynamics. We will discuss future directions including proposed models that can incorporate additional mission days and tasks beyond the TIB for objectively quantifying team behavior at high temporal resolution in space exploration missions.

Projna Paromita↗

Process and Material Design for Micro-Encapsulated Ionic Liquids in Post-Combustion CO 2 Capture

Aprotic Heterocyclic Anion (AHA) Ionic Liquids (ILs) have been identified as promising new solvents for post-combustion carbon capture due to their high CO 2 uptake and the high tenability 1,2 of their binding energy with CO 2 . Some of these compounds change phase (solid to liquid) on absorption of CO 2 ; these Phase Change ILs (PCILs)3 offer the additional advantage that part of the heat needed to desorb the CO2 from the absorbent is provided by the heat of fusion as the PCIL solidifies upon release of CO 2 . However, the relatively high viscosity of AHA ILs and the occurrence of a phase change in PCILs present challenges for conventional absorption equipment. To overcome these challenges we are pursuing the use of new technology to micro-encapsulate the AHA ILs and PCILs. Our partners at Lawrence Livermore National Laboratory have successfully demonstrated this technology in the application of post-combustion carbon capture with sodium and potassium carbonate solutions,4 and have recently shown the feasibility of micro-encapsulation of an AHA IL for carbon capture.5 The large effective surface area and high CO 2 permeability of the micro-capsules is expected to offset the drawback of the high IL viscosity and to provide for a more efficient and cost-effective mass transfer operation involving AHA ILs and PCILs. These opportunities, however, present us with both process and materials design questions. For example, what is the target CO 2 absorption strength (enthalpy of chemical absorption) for the tunable AHA IL? What is the target for micro-capsule diameter in order to obtain a high mass transfer rate and good fluidization performance? What are the appropriate temperatures and pressures for the absorber and stripper? In order to address these and other questions, we have developed a rate-based model of a post-combustion CO 2 capture process using micro-encapsulated ILs. As a performance baseline, we have also developed a rate-based model of a standard packed bed absorber using an un-encapsulated AHA IL absorbent. Using such models we can determine optimal CO 2 capture performance and investigate the sensitivity of the optimum with respect to the key thermo-physical and transport properties of the IL (e.g., CO 2 binding energy, viscosity, etc.) and the micro-capsules (e.g. diameter, CO 2 permeability, etc.). Results of these process and material design studies will be presented, and the performance of this novel micro-encapsulation technology will be assessed.

20 FOSSIL-FUELED POWER PLANTS↗

Residential Home Decarbonization Using Advanced Micro-CHP

An efficient micro-combined heat and power (CHP) prototype was developed to provide heat and electricity for single-family homes and light commercial buildings. The unit can be installed independently at the point of energy consumption. Consequently, it enables cost-effectively and flexibly matching heat and electrical loads, simplifying distribution and installation processes, and recovering and storing waste heat as hot water. The analyzed results show that the micro-CHP using natural gas as fuel achieves 10.68%–32.80% CO2 reduction in the selected five home applications. The potential effect of H2 on decarbonization of these home was also evaluated, finding that the micro-CHP using a blended fuel with H2 and natural gas can further reduce CO2 emissions. However, the 50% CO2 reduction in the micro-CHP requires at least 70%–90% of H2 in the blend with natural gas. Overall, the micro-CHP technology demonstrates a solid potential to accelerate micro-CHP adoption in residential and light commercial markets, thereby promoting broader micro-CHP acceptance and use in the future for building decarbonization.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗