Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “medium voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Enabling thermal efficiency improvement and waste heat recovery using liquid air harnessed from offshore renewable energy sources

A novel approach using decoupled processes to harness offshore renewable energy, from marine hydrokinetics, ocean waves, wind, and solar to produce liquid air, is presented here. Offshore renewables interconnection using submarine medium- and high-voltage direct current technologies are used to produce liquid air that can be transported to end-use locations using repurposed liquefied natural gas tankers. Two important possibilities arise from using the proposed technology. The first possibility allows the integration with conventional thermal cycles to improve efficiency. This approach can be used to leverage efficiencies of thermal systems that have already reached a plateau in the maximum achievable efficiency via design and operation optimization. The second possibility is related to the incorporation of low temperature cycles to recover waste heat from other thermal processes. This is important considering that waste heat accounts for more than 60% of the consumed energy in the United States. A detailed technical description of the complete cycle from cryogen generation to end-use of energy is provided. Estimation of efficiency enhancement for thermal plants using liquid air including waste heat recovery is presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oil-impregnated densified wood veneer with high electrical insulation enabled by nanosized oil channels

Growing energy demands and renewable integration are stressing the aging power grid infrastructure. Lignocellulosic oil-impregnated paper is widely used in power transformers but suffers from critical limitations, such as low dielectric strength, mechanical strength, and thermal conductivity, causing premature transformer failures. Here, we demonstrate a superior electrically insulating oil-impregnated paper design using the naturally anisotropic structure of densified wood veneer to achieve nanosized channels of oil that efficiently disrupt electrical breakdown pathways. The developed oil-impregnated densified wood (ODW) creates aligned cellulose fibers with 166 ± 87–nanometer oil nanochannels, achieving record dielectric strength of 105 kilovolts per millimeter. The structure also delivers a mechanical strength of up to 384 megapascals and a thermal conductivity of 0.33 watts per meter per kelvin, enabling enhanced longevity upon thermal aging tests. The ODW could replace conventional transformer insulation to enhance power transformer performance and improve lifetime. Moreover, its anisotropic oil-filled nanochannel design offers a general strategy for hybrid dielectrics in medium- and high-voltage applications.

36 MATERIALS SCIENCE↗

Study of dielectric breakdown in liquid xenon with XeBrA: The xenon breakdown apparatus

Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding 1 m, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment. The Xenon Breakdown Apparatus (XeBrA) is a 5-l, high voltage test chamber built to investigate the contributing factors to electrical breakdown in noble liquids. Here, in this work, we present the main findings after conducting scans over stressed electrode areas, surface finish, pressure, and high voltage ramp speed in the medium of liquid xenon. Area scaling and surface finish were observed to be the dominant factors affecting breakdown, whereas no significant changes were observed with varying pressure or ramp speed. A general rise in both the anode current and photon rate was observed in the last 30 s, leading up to a breakdown, with a marked increase in the last couple of seconds. In addition, the position of breakdowns was reconstructed with a system of high-speed cameras and a moderate correlation with the Fowler–Nordheim field emission model was found. Tentative evidence for bubble nucleation being the originating mechanism of breakdown in the liquid was also observed. We deem the results presented in this work to be of particular interest for the design of future, large TPCs, and practical recommendations are provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electrical, optical, and magnetic properties of amorphous yttrium iron oxide thin films and consequences for non-local resistance measurements

We present magnetic characterization, charge resistivity, and optical photoluminescence measurements on amorphous yttrium iron oxide thin films ( ⁠a-Y–Fe–O), with supporting comparisons to amorphous germanium (⁠ a-Ge) films. We measured magnetic properties with both SQUID magnetometry and polarized neutron reflectometry. These results not only confirm that a-Y–Fe–O is a disordered magnetic material with strong predominantly antiferromagnetic exchange interactions and a high degree of frustration, but also that it is best understood electrically as a disordered semiconductor. As with amorphous germanium, a-Y–Fe–O obeys expectations for variable-range hopping through localized electron states over a wide range of temperature. We also clarify the consequences of charge transport through such a semiconducting medium for non-local voltage measurements intended to probe spin transport in nominally insulating magnetic materials. We further compare non-local resistance measurements made with “quasi-dc” automated current reversal to ac measurements made with a lock-in amplifier. These show that the “quasi-dc” measurement has an effective ac current excitation with frequency up to approximately 22 Hz, and that this effective ac excitation can cause artifacts in these measurements including incorrect sign of the non-local resistance. Here, this comprehensive investigation of non-local resistance measurements in a-Y–Fe–O shows no evidence of spin transport on micrometer length scales, which is contrary to our original work, and in line with more recent investigations by other groups.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New Modulation and Impact of Transformer Leakage Inductance on Current-Source Solid-State Transformer

This article presents a novel modulation scheme for device voltage stress mitigation and comprehensive analysis of the impact of transformer leakage inductance in a current-source solid-state transformer (SST). Different from dual active bridge (DAB) SST, the operation of the current-source SST is similar to that of a flyback converter. The device bridge on only one side of the transformer is active to store energy into or release energy from the magnetizing inductance which acts as a current-source dc link. Such flyback operation with reverse-blocking switches can lead to additional device voltage stress and incomplete zero-voltage switching (ZVS) on the current-source soft-switching solid-state transformer (S4T) under conventional modulation. A new modulation scheme is proposed to address this issue. Moreover, different from the DAB, the leakage inductance of the medium-frequency transformer (MFT) in the S4T is a parasitic element similar to that in a matrix SST and can cause additional device voltage stress. Though the resonant capacitors, originally added to achieve ZVS, can absorb and recycle the leakage energy in the S4T, these capacitors need to be increased with larger leakage inductances to limit the voltage stress. However, large resonant capacitors can result in more lost duty cycles and reduced efficiency. The impact of such leakage inductance on device voltage stress is analyzed comprehensively, which is critical to guide future research and design of the S4T. Experimental results from S4T prototypes for DC-DC, multiport AC-DC, and AC-AC conversion with 1:1 and 4:1 MFT comprehensively verify the proposed concepts. Lastly, a case study of a three-phase AC-AC S4T over a power range from 1 kVA to 100 kVA each module reveals that the MFT leakage inductance should be less than 1% of the magnetizing inductance for safe operation.

14 SOLAR ENERGY↗

Underwater plasma breakdown characteristics with respect to highly pressurized drilling applications

Deep earth drilling is a key technique to extract oil, gas, and geothermal heat from the earth. Many complex energy focusing methods have been explored as an alternative approach to reach these resources but most of them require high energy. However, by utilizing short time span liquid plasma discharges, energy focusing can be achieved within traditional drilling systems. These discharges induce a rapid expansion process and a resulting shockwave. It is believed that this focused energy will lower the required cutting force to progress through the rock. Lowering the required cutting force will allow for lower drill bit wear, quicker rate of penetration, and an overall cost savings of the project. Plasma breakdown characteristics at drilling relevant pressures, ranging from 1 to 350 atm, were studied. A resistance–capacitance circuit with an air gapped spark switch was utilized to generate pulsed plasma between the pressurized electrodes. It was found that the required breakdown voltage increases as the pressure increases. It was also found that a plasma channel formation and an associated breakdown may or may not occur between the electrodes at different pressures due to variation in required breakdown voltages. Breakdown time-lag in the dielectric medium (tap water, 780 μS cm –1 ) increased as the pressure was increased, which indicated a higher voltage drop at higher pressures (>100 atm). The plasma generated cavitation bubble with an associated shockwave occurred as pressures were increased. However, the bubble radius and the bubble duration decreased as the pressure was increased. The plasma generated shockwave speeds fall within the expected speed of sound in water. Lastly, preliminary rock cracking tests were performed on granite at high pressures (340 and 272 atm) and it was found that plasma is able to create cracks in the rock.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System and method for acoustic to electronic transduction

According to various embodiments, a system for acoustic to electronic transduction is disclosed. The system includes a transducing medium configured to convert a received acoustic signal into a transduced electronic signal when a voltage is applied. The system further includes a high-pass filter coupled to the transducing medium, the high-pass filter configured to isolate the transduced signal from the applied voltage.

Carlsson, Johan A.↗

Tritiated Sulfur Hexafluoride Disposition Strategies

Tritium (T 2 ) is a radioactive isotope of hydrogen that is produced in nuclear fission reactions and is often used in nuclear fusion reactions and accelerator-based applications for medical isotope production. As a hydrogen isotope, tritium can readily bind to hydroxyl radicals (OH), forming tritiated water (HTO or T 2 0), and to carbon atoms. Tritium decays to helium-3 ( 3 He) via beta-decay with max decay energy of 18.6 keV. While it is not an external radiation hazard, it can be an internal radiation hazard if tritium is inhaled, ingested, or absorbed through the skin. In applications where tritium is handled, tritium confinement is performed using different barriers to minimize releases to the environment. For gaseous (elemental), liquid (oxide), and metal (hydride) tritium, process piping and components provide the primary confinement function. Secondary tritium confinement is typically provided by inert (i.e. non-flammable gases such as nitrogen, argon, or helium) gloveboxes which are connected to a tritium stripper system. Primary tritium confinement barriers typically produce low volumes of high tritium concentrations of tritiated methane from carbon in steels or organic materials along with tritiated water/tritium oxide (e.g. HTO) and tritiated ammonia from reactions with oxygen and nitrogen. Tritium escaping primary confinement into secondary confinement atmospheres (e.g. gloveboxes) produce higher volumes of lower activity contamination than found in process piping. Tritium contamination also occurs by leaks or tritium permeation/diffusion through confinement materials. Tritium from inside primary confinement barriers will diffuse or leak out of the primary confinement barrier and usually into the air, if the system is inside an air hood or ventilated hot cell, or into the secondary confinement (e.g. glovebox) atmosphere which is either exhausted or stripped based on the function of the secondary confinement (glovebox) system. Accelerator based processes for medical isotope production represent an atypical tritium contamination challenge. In medical isotope production, deuterium supply gas is ionized and accelerated to a tritium gas target to produce neutrons that are then used to produce the medical isotopes through additional nuclear fission reactions. To create large voltage differentials for accelerator operations, an electrical insulation medium is needed to prevent or rapidly quench electric discharges. A common electrical insulation medium utilized in accelerator applications is sulfur hexafluoride (SF 6 ) gas. SF 6 has a high dielectric strength and allows for the construction of smaller accelerator systems compared to other electrical insulation mediums such as air or dry nitrogen. Due to tritium permeation/diffusion through accelerator process and confinement materials, there is the possibility that tritium can contaminate the electrical insulation medium of the accelerator. Tritium contaminated SF 6 creates a material without any obvious processes for managing the contamination, reuse, or disposal of the used SF 6 . This document will discuss possible management strategies for tritium contaminated SF 6 for accelerator-based processes for Molybdenum-99 (Mo-99) production.

07 ISOTOPE AND RADIATION SOURCES↗

Full Concentration Gradient-Tailored Li-Rich Layered Oxides for High-Energy Lithium-Ion Batteries

Lithium-rich layered oxides (LLOs) are prospective cathode materials for next-generation lithium-ion batteries (LIBs), but severe voltage decay and energy attenuation with cycling still hinder their practical applications. In this study, a series of full concentration gradient-tailored agglomerated-sphere LLOs are designed with linearly decreasing Mn and linearly increasing Ni and Co from the particle center to the surface. The gradient-tailored LLOs exhibit noticeably reduced voltage decay, enhanced rate performance, improved cycle stability, and thermal stability. Without any material modifications or electrolyte optimizations, the gradient-tailored LLO with medium-slope shows the best electrochemical performance, with a very low average voltage decay of 0.8 mV per cycle as well as a capacity retention of 88.4% within 200 cycles at 200 mA g –1 . These excellent findings are due to spinel structure suppression, electrochemical stress optimization, and Jahn-Teller effect inhibition. Further investigation shows that the gradient-tailored LLO reduces the thermal release percentage by as much as about 41% when the battery is charged to 4.4 V. This study provides an effective method to suppress the voltage decay of LLOs for further practical utilization in LIBs and also puts forward a bulk-structure design strategy to prepare better electrode materials for different rechargeable batteries.

36 MATERIALS SCIENCE↗

A Medium-/Low-Voltage Joint State Estimator Through Linear Uncertainty Propagation

Traditionally, distribution system state estimations (DSSE) are challenged by the lack of measurements at both primary and secondary sides of the system. The widely available cable television (CATV) voltage sensors installed in low-voltage (LV) networks bring opportunities to achieve higher quality DSSE covering a broader area of the distribution network. This study proposes a medium-/low-voltage (MV/LV) joint distribution system state estimation approach using the untapped CATV measurements. It aims at addressing the need for system situational awareness at the grid edge while improving the estimation accuracy at both the primary and secondary sides compared to its disjointed counterpart. Linearized measurement functions and boundary condition uncertainty propagation rules are derived to ensure the computational efficiency and accuracy of the joint state estimator. Numerical experiments are conducted on an IEEE test feeder to demonstrate the efficacy of the proposed method and the value of CATV measurements.

joint state estimation↗

Giant piezoelectricity in fluoropolymer fiber mats achieved by corona poling in water

Polymer piezoelectrics hold great potential for energy harvesting and wearable electronics. Efforts have been dedicated to enhancing piezoelectric coefficients and thermostability for several decades, but most of these have not been successful. In this report, we demonstrate a straightforward way to achieve high piezoelectric coefficients and output voltages while maintaining high thermostability at temperatures over 110 °C. Poly(vinylidene fluoride-co-trifluoroethylene) [P(VDF-TrFE)] 80/20 mol.% nanofiber mats (made by electrospinning) with extremely high crystallinity and Curie temperatures were obtained via a two-step annealing process, from which large ferroelectric domains were formed in extended-chain crystals. After corona poling using water, which is a high dielectric constant medium, giant piezoelectricity (apparent d 33 = 1045 ± 20 pC/N) and high output voltages (29.9 ± 0.5 V) were achieved. It is found that the dimensional effect induced significant polarization changes, which is the key requirement for piezoelectricity. Our finding in this work paves a way to further improve high-performance polymer piezoelectrics.

36 MATERIALS SCIENCE↗

Conservation Voltage Reduction (CVR) via Two-Timescale Control in Unbalanced Power Distribution Systems

Voltage control devices are employed in power distribution systems to reduce the power consumption by operating the system closer to the lower acceptable voltage limits; this technique is called conservation voltage reduction (CVR). The different modes of operation for system’s legacy devices (with binary control) and new devices (e.g. smart inverters with continuous control) coupled with variable photovoltaic (PV) generation results in voltage fluctuations which makes it challenging to achieve CVR objective. This paper presents a two-timescale control of feeder’s voltage control devices to achieve CVR that includes (1)a centralized controller operating in a slower time-scale to coordinate voltage control devices across the feeder and (2) local controllers operating in a faster timescale to mitigate voltage fluctuations due to PV variability. The centralized controller utilizes a three-phase optimal power flow model to obtain the decision variables for both legacy devices and smart inverters. The local controllers operate smart inverters to minimize voltage fluctuations and restore nodal voltages to their reference values by adjusting the reactive power support. The proposed approach is validated using the IEEE-123 bus (medium-size) and R3-12.47-2 (large-size) feeders. It is demonstrated that the proposed approach is effective in achieving the CVR objective for unbalanced distribution systems.

optimal control, distributed generation, fluctuati↗

Accessing a high‐voltage nonaqueous hybrid flow battery with a sodium‐methylphenothiazine chemistry and a sodium‐ion solid electrolyte

Abstract The development of redox flow batteries (RFBs) with nonaqueous electrolytes offers the possibility of accessing a high cell‐operation voltage (no restrain of hydrogen evolution and oxygen evolution potentials) and a low operation temperature (can be operated below the freezing point of water). Therefore, nonaqueous RFBs have recently garnered increasing attention. However, the cross‐mixing of liquid electrode/electrolyte materials has been plaguing the progress of the nonaqueous RFBs. Herein, we present a crossover‐free, high voltage nonaqueous hybrid flow battery (HFB) with a novel sodium‐methylphenothiazine (MPT) chemistry and a single‐ion solid‐electrolyte separator. The Na‐MPT redox couple delivers a high voltage of ~2.6 V when the cell was operated at a medium current density. A NASICON‐type solid electrolyte membrane (Na 3 Zr 2 Si 2 PO 12 ) could circumvent the crossover of the liquids between the positive and negative electrodes, and meanwhile could maintain a single‐ion (Na + ‐ion) conduction between the two electrodes to sustain the electrochemical reactions. Under such an electrochemical mechanism, the nonaqueous Na‐MPT HFB shows remarkable cycling performance.

Yu, Xingwen↗

LAMP Technical Readiness Evaluation Report

An internal preliminary evaluation of Critical Technology Elements (CTEs) for the LANSCE Modernization Project (LAMP) was completed in 2023. This included determining corresponding Technical Readiness Levels (TRLs) for all subsystems using the criteria of DOE G 413.3-4A, Technical Readiness Assessment Guide. This revised report includes a summary of the recent design modifications required to meet the project Key Performance Requirements (KPPs), some of which may reduce technical risk to the project. These recent design modifications include: • Further optimization of the low-energy and medium-energy beam transport regions (LEBT and MEBT, respectively), including relocation of various functional elements (ie choppers, kickers, and bunchers). • An additional H - ion source to separate ion-source function based on beam delivery requirements. • A high-repetition-rate pulsed kicker magnet to select/merge the two H ion beams into a common low-energy beam transport. • Modification and further optimization to a more conventional RFQ design. Performance of the RFQ has been optimized to deliver the required three types of beams while meeting the project KPPs. • The addition of a second chopper in the medium-energy beam transport (MEBT) line to reduce the required pulser voltages. The scope of the evaluation was limited to the project Work Breakdown Structure (WBS) elements as defined for the RFQ Injector and Drift Tube Linac (DTL) systems only. Integration of Instrumentation and Controls (I&C) and Safety Systems was not considered, although specific technologies as related to the RFQ and DTL systems were included. Other elements of the project such as Shielding, System Design, Technical Management, and additional facility integration needed to enable off-line testing and pre-installation commissioning were also not evaluated. Each technical subsystem element was evaluated for technical readiness, however, not all were found to meet the criteria for a CTE. Three subsystem elements were determined to meet the CTE criteria. Their associated TRLs are summarized in the table below. These subsystem elements of the project have the lowest technical readiness due to either being new, novel or modified, requiring additional R&D before being capable of meeting the project Key Performance Parameters (KPPs) and subsystem requirements, or present technology exists but has not yet been demonstrated in a relevant environment. All other subsystems were determined to have a TRL of 8, indicating that actual operating systems exist having similar performance requirements as needed for LAMP. Details of the technical readiness evaluation for each subsystem is given in the following sections of this report.

43 PARTICLE ACCELERATORS↗

LAMP Technical Readiness Evaluation Report: LAMP-ENG-RPT-003 (Revision 2)

An internal preliminary evaluation of Critical Technology Elements (CTEs) for the LANSCE Modernization Project (LAMP) was completed in 2023. This included determining corresponding Technical Readiness Levels (TRLs) for all subsystems using the criteria of DOE G 413.3-4A, Technical Readiness Assessment Guide. This revised report includes a summary of the recent design modifications required to meet the project Key Performance Requirements (KPPs), some of which may reduce technical risks to the project. These recent design modifications are based on the LAMP Conceptual Design which is the design evaluated in this document and include: • Further optimization of the low-energy and medium-energy beam transport regions (LEBT and MEBT, respectively), including relocation of various functional elements (i.e. choppers, kickers, and bunchers). • An additional 100-keV H - ion source to separate ion-source function based on beam delivery requirements. • A high-repetition-rate pulsed kicker magnet to select/merge the two H - ion beams into a common low-energy beam transport. • Modification and further optimization to a more conventional 3-MeV Radio Frequency Quadrupole (RFQ) design. Performance of the RFQ has been optimized to deliver the required three types of beams while meeting the project Key Performance Parameters (KPPs). • The addition of a second chopper in the medium-energy beam transport (MEBT) line to reduce the required pulser voltages.

43 PARTICLE ACCELERATORS↗

Radio frequency and DC high voltage breakdown of high pressure helium, argon, and xenon

Motivated by the possibility of guiding daughter ions from double beta decay events to single-ion sensors for barium tagging, the NEXT collaboration is developing a program of R&D to test radio frequency (RF) carpets for ion transport in high pressure xenon gas. This would require carpet functionality in regimes at higher pressures than have been previously reported, implying correspondingly larger electrode voltages than in existing systems. This mode of operation appears plausible for contemporary RF-carpet geometries due to the higher predicted breakdown strength of high pressure xenon relative to low pressure helium, the working medium in most existing RF carpet devices. In this paper we present the first measurements of the high voltage dielectric strength of xenon gas at high pressure and at the relevant RF frequencies for ion transport (in the 10 MHz range), as well as new DC and RF measurements of the dielectric strengths of high pressure argon and helium gases at small gap sizes. We find breakdown voltages that are compatible with stable RF carpet operation given the gas, pressure, voltage, materials and geometry of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reports from the Frontier: Understanding Voltage Losses in Anion Exchange Membrane Water Electrolyzers

With the growth of renewable energy sources, hydrogen is attracting significant attention worldwide as an effective medium for energy storage. “Green hydrogen” is currently produced primarily by water electrolysis in which water is split into hydrogen and oxygen using power from low-carbon energy sources such as wind, solar, and nuclear. Among the low temperature water electrolysis technologies, anion exchange membrane water electrolyzers (AEMWEs) have recently emerged as a promising competitor to traditional alkaline water electrolyzers (AWEs) and proton exchange membrane electrolyzers (PEMELs) due to their potential stack cost reduction in various cell components. In conclusion, favorable aspects of AEMWEs include the use of PGM-free electrocatalysts as well as low-cost membranes, bipolar plates (BPs), and porous transport layers while offering high voltage efficiency and durability.

08 HYDROGEN↗