Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Bit error rate measurement for evaluation of a fiber optic link

Digital fiber-optic data-link terminal modules are being developed in a number of laboratories, and often the modules take the form of black boxes without convenient access to internal signals. This paper discusses types of measurements which can be made using only the digital terminals of the link. Bit-error-rate (BER) vs signal-power data can, of course, provide a means for proving overall link performance, but it can also be used to determine certain internal parameters of the receiver. The theoretical dependence of the BER-vs-light-signal-power curve shape on receiver input-noise equivalent power and comparator slicing level is discussed. BER-vs-light-signal-power measurements obtained with an experimental link are presented and interpreted with the aid of the theoretical curves. The effects of other problems, such as hum or oscillation, on the BER data are mentioned. Sensitivity of the system BER to bit rate is also discussed, with application to determining system operating limits. Since BER measurements are simple to make and can easily be automated, they may prove to be a useful means for either laboratory evaluation or production-line acceptance testing of sealed terminal modules.

Bergman, L. A.↗

LIDAR Wind Speed Measurements of Evolving Wind Fields

Light Detection and Ranging (LIDAR) systems are able to measure the speed of incoming wind before it interacts with a wind turbine rotor. These preview wind measurements can be used in feedforward control systems that are designed to reduce turbine loads. However, the degree to which such preview-based control techniques can reduce loads by reacting to turbulence depends on how accurately the incoming wind field can be measured. Past studies have assumed the validity of physicist G.I. Taylor's 1938 frozen turbulence hypothesis, which implies that turbulence remains unchanged as it advects downwind at the mean wind speed. With Taylor's hypothesis applied, the only source of wind speed measurement error is distortion caused by the LIDAR. This study introduces wind evolution, characterized by the longitudinal coherence of the wind, to LIDAR measurement simulations using the National Renewable Energy Laboratory's (NREL's) 5-megawatt turbine model to create a more realistic measurement model. A simple model of wind evolution was applied to a frozen wind field that was used in previous studies to investigate the effects of varying the intensity of wind evolution. LIDAR measurements were also evaluated using a large eddy simulation (LES) of a stable boundary layer that was provided by the National Center for Atmospheric Research. The LIDAR measurement scenario investigated consists of a hub-mounted LIDAR that scans a circle of points upwind of the turbine in order to estimate the wind speed component in the mean wind direction. Different combinations of the preview distance that is located upwind of the rotor and the radius of the scan circle were analyzed. It was found that the dominant source of measurement error for short preview distances is the detection of transverse and vertical wind speeds from the line-of-sight LIDAR measurement. It was discovered in previous studies that, in the absence of wind evolution, the dominant source of error for large preview distances is the spatial averaging caused by the LIDAR's sampling volume. However, by introducing wind evolution, the dominant source of error for large preview distances was found to be the coherence loss caused by evolving turbulence. Different measurement geometries were compared using the bandwidth for which the measurement coherence remained above 0.5 and also the area under the measurement coherence curve. Results showed that, by increasing the intensity of wind evolution, the measurement coherence decreases. Using the coherence bandwidth metric, the optimal preview distance for a fixed-scan radius remained almost constant for low and moderate amounts of wind evolution. For the wind field with the simple wind evolution model introduced, the optimal preview distance for a scan radius of 75% blade span (47.25 meters) was found to be 80 meters. Using the LES wind field, the optimal preview distance was 65 meters. When comparing scan geometries using the area under the coherence curve, results showed that, as the intensity of wind evolution increases, the optimal preview distance decreases.

17 WIND ENERGY↗

Breast Patient Setup Error Assessment: Comparison of Electronic Portal Image Devices and Cone-Beam Computed Tomography Matching Results

Purpose: To quantify the differences in setup errors measured with the cone-beam computed tomography (CBCT) and electronic portal image devices (EPID) in breast cancer patients. Methods and Materials: Repeat CBCT scan were acquired for routine offline setup verification in 20 breast cancer patients. During the CBCT imaging fractions, EPID images of the treatment beams were recorded. Registrations of the bony anatomy for CBCT to planning CT and EPID to digitally reconstructed-radiographs (DRRs) were compared. In addition, similar measurements of an anthropomorphic thorax phantom were acquired. Bland-Altman and linear regression analysis were performed for clinical and phantom registrations. Systematic and random setup errors were quantified for CBCT and EPID-driven correction protocols in the EPID coordinate system (U, V), with V parallel to the cranial-caudal axis and U perpendicular to V and the central beam axis. Results: Bland-Altman analysis of clinical EPID and CBCT registrations yielded 4 to 6-mm limits of agreement, indicating that both methods were not compatible. The EPID-based setup errors were smaller than the CBCT-based setup errors. Phantom measurements showed that CBCT accurately measures setup error whereas EPID underestimates setup errors in the cranial-caudal direction. In the clinical measurements, the residual bony anatomy setup errors after offline CBCT-based corrections were {Sigma}{sub U} = 1.4 mm, {Sigma}{sub V} = 1.7 mm, and {sigma}{sub U} = 2.6 mm, {sigma}{sub V} = 3.1 mm. Residual setup errors of EPID driven corrections corrected for underestimation were estimated at {Sigma}{sub U} = 2.2mm, {Sigma}{sub V} = 3.3 mm, and {sigma}{sub U} = 2.9 mm, {sigma}{sub V} = 2.9 mm. Conclusion: EPID registration underestimated the actual bony anatomy setup error in breast cancer patients by 20% to 50%. Using CBCT decreased setup uncertainties significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SRF Cavity Testing Using a FPGA Self Excited Loop

This document provides a detailed description of procedures for very-high precision calibration and testing of superconducting RF cavities using digital Low-Level RF (LLRF) electronics based on Field Programmable Gate Arrays (FPGA). The use of a Self-Excited Loop with an innovative procedure for fast turn-on allows the measurement of the forward, reflected and transmitted power from a single port of the directional coupler in front of the cavity, thus eliminating certain measurement errors. Various procedures for measuring the quality factor as a function of cavity fields are described, including a single RF pulse technique. Errors are estimated for the measurements.

43 PARTICLE ACCELERATORS↗

Open Source Fault-tolerant Grid Frequency Measurement for Solar Inverters

The Discrete Fourier transform (DFT) based measurement algorithms are one of the most common measurement algorithms for grid parameter estimation such as rms, phase angle, frequency. Over the past few years, many DFT based algorithms have been developed to enhance its measurement accuracy under steady-state and/or dynamic grid conditions. For example, an adaptive band-pass filter utilizing exponential modulation filter has been proposed to reduce measurement errors at the presence of large frequency deviations. Measurement accuracy of different algorithms including FIR filter, extended Kalman filtering (EKF), and enhanced DFT method have been compared in detail under different grid conditions. Two artificial signals that have 90-degree phase difference were constructed by the Clarke transformation to address the frequency spectrum leakage of DFT. A multi-module approach was developed to enhance both steady-state and dynamic measurement accuracies, in which each module was developed to eliminate some specific errors. Besides DFT-based measurement algorithms, some signal model-based algorithms have been developed to further improve the accuracy under dynamic conditions. However, a key drawback of the state-of-the-art algorithms is that they cannot perform measurements accurately during system transient faults. In the Blue Cut Fire event, there was a phase angle jump of about 26 degrees in the voltage waveform during the transient fault. The phase angle jump fault will cause waveform discontinuity, and these algorithms will fail to provide reliable measurements during this period because they typically assume the waveform to be measured is continuous, no matter what method (DFT, PLL, EKF, FIR, or Taylor WLS) is used for estimation. In fact, the measurement errors during the system transient faults like phase-jump is not required in the IEEE Standard. As a result, although a measurement instrument can pass the strict IEEE Standard, it could still be the source of the problem in the future if we have similar system transient faults, which could happen again. Therefore, developing the fault-tolerant measurement technology is the key to solve the problem.

14 SOLAR ENERGY↗

Absolute flux density calibrations: Receiver saturation effects

The effect of receiver saturation was examined for a total power radiometer which uses an ambient load for calibration. Extension to other calibration schemes is indicated. The analysis shows that a monotonic receiver saturation characteristic could cause either positive or negative measurement errors, with polarity depending upon operating conditions. A realistic model of the receiver was made by using a linear-cubic voltage transfer characteristic. The evaluation of measurement error for this model provided a means for correcting radio source measurements.

Freiley, A. J.↗

Error Propagation in Microwave Soil Moisture and Vegetation Optical Depth Retrievals

Satellite soil moisture and vegetation optical depth (VOD; related to the total vegetation water mass per unit area) are increasingly being used to study water relations in the soil-plant continuum across the globe. However, soil moisture and VOD are typically jointly estimated, where errors in the optimization approach can cause compensation between both variables and confound such studies. It is thus critical to quantify how satellite microwave measurement errors propagate into soil moisture and VOD. Such a study is especially important for VOD given limited investigations of whether VOD reflects in-situ plant physiology. Furthermore, despite new approaches that constrain (or regularize) VOD dynamics to reduce soil moisture errors, there is limited study of whether regularization reduces VOD errors without obscuring true vegetation temporal dynamics. Here, we find that, across the globe, VOD is less robust to measurement error (more difficult for optimization methods to find the true solution) than soil moisture in their joint estimation. However, a moderate degree of regularization (via time-constrained VOD) reduces errors in VOD to a greater degree than soil moisture and reduces spurious soil moisture-VOD coupling. Furthermore, despite constraining VOD time dynamics, regularized VOD variations on sub-weekly scales are both closer to simulated true VOD time series and have global VOD post-rainfall responses with reduced error signatures compared to VOD retrievals without regularization. Ultimately, we recommend moderately regularized VOD for use in large scale studies of soil-plant water relations because it suppresses noise and spurious soil moisture-VOD coupling without removing the physical signal.

Vegetation optical depth↗

Information Theoretic Evaluation of Satellite Soil Moisture Retrievals

Microwave radiometry has a long legacy of providing estimates of remotely sensed near surfacesoil moisture measurements over continental and global scales. A consistent assessment of theerrors and uncertainties associated with these retrievals is important for their effective utilization in modeling, data assimilation and end-use application environments. This article presents an evaluationof soil moisture retrieval products from AMSR-E, ASCAT, SMOS, AMSR2 and SMAPinstruments using information theory-based metrics. These metrics rely on time series analysis ofsoil moisture retrievals for estimating the measurement error, level of randomness (entropy) andregularity (complexity) of the data. The results of the study indicate that the measurement errors inthe remote sensing retrievals are significantly larger than that of the ground soil moisture measurements.The SMAP retrievals, on the other hand, were found to have reduced errors (comparable to Preprint submitted to Remote Sensing of Environment October 1, 2017those of in-situ datasets), particularly over areas with moderate vegetation. The SMAP retrievals also demonstrate high information content relative to other retrieval products, with higher levelsof complexity and reduced entropy. Finally, a joint evaluation of the entropy and complexity ofremotely sensed soil moisture products indicates that the information content of the AMSR-E, ASCAT,SMOS and AMSR2 retrievals is low, whereas SMAP retrievals show better performance. The use of information theoretic assessments is effective in quantifying the required levels of improvements needed in the remote sensing soil moisture retrievals to enhance their utility and information content.

Information theory↗

SU-E-T-482: In Vivo Dosimetry of An Anthropomorphic Phantom by Using the RADPOS System for Proton Beam Therapy

Purpose: Delivered doses in an anthropomorphic phantom were evaluated by using the RADPOS system for proton beam therapy. Methods: The RADPOS in vivo dosimetry system combines an electromagnetic positioning sensor with MOSFET dosimetry, allowing simultaneous online measurements of dose and spatial position. Through the RADPOS system, dose evaluation points can be determined. In vivo proton dosimetry was evaluated by using the RADPOS system and anthropomorphic head and neck phantom. MOSFET doses measured at 3D positions obtained with the RADPOS were compared to the treatment plan values that were calculated by a simplified Monte Carlo (SMC) method. Although the MOSFET response depends strongly on the linear energy transfer (LET) of proton beam, the MOSFET responses to proton beams were corrected with the SMC. Here, the SMC calculated only dose deposition determined by the experimental depth–dose distribution and lateral displacement of protons due to both multiple scattering effect in materials and incident angle. As a Result, the SMC could quickly calculate accurate doses in even heterogeneities. Results: In vivo dosimetry by using the RADPOS, as well as the MOSFET doses agreed in comparison with calculations by the SMC in the range of −3.0% to 8.3%. Most measurement errors occurred because of the uncertainties of dose calculations due to the position error of 1 mm. Conclusion: We evaluated the delivered doses in the anthropomorphic phantom by using the RADPOS system for proton beam therapy. The MOSFET doses agreed in comparison with calculations by the SMC within the measurement error. Therefore, we could successfully control the uncertainties of the measurement positions by using the RADPOS system within 1 mm in in vivo proton dosimetry. We aim for the clinical application of in vivo proton dosimetry with this RADPOS system.

60 APPLIED LIFE SCIENCES↗

An Ultra-Precise System for Electrical Resistivity Tomography Measurements

The objective of this research was to determine the feasibility of building and operating an ERT system that will allow measurement precision that is an order of magnitude better than existing systems on the market today and in particular if this can be done without significantly greater manufacturing or operating costs than existing commercial systems. Under this proposal, we performed an estimation of measurement errors in galvanic resistivity data that arise as a consequence of the type of electrode material used to make the measurements. In our laboratory, measurement errors for both magnitude and induced polarization (IP) were estimated using the reciprocity of data from an array of electrodes as might be used for electrical resistance tomography using 14 different metals as well as one non-metal - carbon. In a second phase of this study, using archival data from two long-term ERT surveys, we examined long-term survivability of electrodes over periods of several years. The survey sites were: the Drift Scale Test at Yucca Mountain, Nevada (which was sponsored by the U. S. Department of Energy as part of the civilian radioactive waste management program), and a water infiltration test at a site adjacent to the New Mexico Institute of Mines and Technology in Socorro, New Mexico (sponsored by the Sandia/Tech vadose program). This enabled us to compare recent values with historical values and determine electrode performance over the long-term as well as the percentage of electrodes that have failed entirely. We have constructed a prototype receiver system, made modifications and revised the receiver design. The revised prototype uses a new 24 bit analog to digital converter from Linear Technologies with amplifier chips from Texas Instruments. The input impedance of the system will be increased from 107 Ohms to approximately 1010 Ohms. The input noise level of the system has been decreased to approximately 10 Nanovolts and system resolution to about 1 Nanovolt at the highest gain range of 125 to 1. The receiver also uses very high precision and high temperature stability components. The goal is to improve the accuracy to better than 0.1%. The system has more receiver channels, eight, to allow efficient data collection at lower base frequencies. We are also implementing a frequency-domain acquisition mode in addition to the time-domain acquisition mode used in the earlier systems. Initial field tests were started in the fall of 2008. We conducted tests on a number of types of cable commonly used for resistivity surveys. A series of different tests were designed to determine if the couplings were primarily resistive, capacitive, or inductive in nature and to ascertain that the response was due to the cable cross-talk and did not depend on the receiver electronics. The results show that the problem appears to be primarily capacitive in nature and does not appear to be due to problems in the receiver electronics. Thus a great deal of emphasis has been placed on finding appropriate cables as well as stable electrodes that have low contact impedance at the very low current flows observed at the receiver. One of the issues in survey design and data collection has been determining how long one must wait before using the same electrode as a transmitter and as a receiver. A series of tests was completed in the laboratory sand tank where four-electrode measurements were made using the same dipole transmitters and dipole receivers (the dipoles used adjacent electrodes). For each data series, a single set of normal measurements were collected with no reciprocals and electrodes were never reused as a receiver after being used as a transmitter. After waiting a specified length of time, the reciprocal measurements were collected using a schedule of measurements. The order of this second schedule was rearranged such that if this second set of measurements were performed without first using the normal schedule, no electrode would be used as a receiver after being used as a transmitter. For this study, we cannot conclude that increasing the wait time increased or decreased the reciprocal errors, only that there was not a dramatic change in results with different wait times. Another issue in ERT data collection is the potential for the transmitter as well as the receiver end of an ERT system to create problems with reciprocity readings. Existing ERT systems typically use a constant voltage source. For the transmitter dipole, a constant voltage source has low output impedance, whereas a constant current source has high output impedance. Therefore, we devised an experiment to determine if a constant current source transmitter might produce smaller errors than a constant voltage source. These preliminary results suggest there is little or no difference in either resistivity or chargeability reciprocal errors using a constant voltage or constant current dipole drive source.

47 OTHER INSTRUMENTATION↗

Optimum quantisers for a Gaussian input probability density and for the magnitude-error distortion measure

The parameters of non-uniform and uniform quantizers up to ten bits of quantization, optimum for a Gaussian input probability and for the magnitude-error distortion criterion are computed. Optimum quantizers must be understood as quantizers with minimum distortion. The numerical method used for the optimization converges relatively rapidly. The comparison between optimum non-uniform quantizers and optimum uniform quantizers is made.

Demaret, J. C.↗

PDE-constrained high-order mesh optimization

Here, we present a novel framework for PDE-constrained r-adaptivity of high-order meshes. The proposed method formulates mesh movement as an optimization problem, with an objective function defined as a convex combination of a mesh quality metric and a measure of the accuracy of the PDE solution obtained via finite element discretization. The proposed formulation achieves optimized, well-defined high-order meshes by integrating mesh quality control, PDE solution accuracy, and robust gradient regularization. We adopt the Target-Matrix Optimization Paradigm to control geometric properties across the mesh, independent of the PDE of interest. To incorporate the accuracy of the PDE solution, we introduce error measures that control the finite element discretization error. The implicit dependence of these error measures on the mesh nodal positions is accurately captured by adjoint sensitivity analysis. Additionally, a convolution-based gradient regularization strategy is used to ensure stable and effective adaptation of high-order meshes. We demonstrate that the proposed framework can improve mesh quality and reduce the error by up to 10 times for the solution of Poisson and linear elasto-static problems. The approach is general with respect to the dimensionality, the order of the mesh, the types of mesh elements, and can be applied to any PDE that admits well-defined adjoint operators.

Computer science↗

Lightning Radio Source Retrieval Using Advanced Lightning Direction Finder (ALDF) Networks

A linear algebraic solution is provided for the problem of retrieving the location and time of occurrence of lightning ground strikes from an Advanced Lightning Direction Finder (ALDF) network. The ALDF network measures field strength, magnetic bearing and arrival time of lightning radio emissions. Solutions for the plane (i.e., no Earth curvature) are provided that implement all of tile measurements mentioned above. Tests of the retrieval method are provided using computer-simulated data sets. We also introduce a quadratic planar solution that is useful when only three arrival time measurements are available. The algebra of the quadratic root results are examined in detail to clarify what portions of the analysis region lead to fundamental ambiguities in source location. Complex root results are shown to be associated with the presence of measurement errors when the lightning source lies near an outer sensor baseline of the ALDF network. In the absence of measurement errors, quadratic root degeneracy (no source location ambiguity) is shown to exist exactly on the outer sensor baselines for arbitrary non-collinear network geometries. The accuracy of the quadratic planar method is tested with computer generated data sets. The results are generally better than those obtained from the three station linear planar method when bearing errors are about 2 deg. We also note some of the advantages and disadvantages of these methods over the nonlinear method of chi(sup 2) minimization employed by the National Lightning Detection Network (NLDN) and discussed in Cummins et al.(1993, 1995, 1998).

Koshak, William J.↗

Novel Lightweight, Low-Cost Heliostat for Concentrating Solar Power (SBIR Phase I Final Report)

The overall goal of this Department of Energy (DOE) SBIR Phase I project was to demonstrate the feasibility of the L.Garde, Inc. heliostat mirror facet for use in concentrated solar power applications. Prior to this Phase I project, L.Garde, Inc. developed a design for a lightweight and low cost mirror facet and successfully fabricated small scale (0.667 m 2 ) with a mirror surface flatness of 0.7 mrad. Therefore, the focus of the Phase I effort was to (1) demonstrate scalability by fabricating larger size mirrors while retaining the same mirror surface flatness, (2) demonstrate the design can withstand operating environment conditions through field testing, and (3) perform cost analysis to show the heliostat mirror facet design can meet DoE goals of < 12 kg/m2 and <$30/m 2 . During the Phase I project, L.Garde successfully fabricated large area (1.395 m 2 ) heliostat mirror facets, with a mass per unit area of 8 kg/m 2 and a cost of $29.80/m 2 . Surface flatness measurements (using contact probe technique) were performed on the mirror surface and results showed a flatness of 0.68 mrad, which were in agreement with previously fabricated small scale mirror facets. Slope error measurements was also performed on the mirror surface and results showed a slope error of 0.77 mrad which also was in agreement with previously fabricated small scale mirror facets. One large area mirror facet was subjected to a three (3) month field test. Surface flatness and slope error measurements were performed on the mirror surface after the field test and results were 0.663 mrad and 0.58 mrad respectively. The large scale heliostat mirror facets were also subjected to accelerated aging. However, during this exposure we observed failure due to the breaking of the mirror facets. Further investigation into the source of the failure showed that the mirror component alone showed signs of degradation during the same accelerated aging test. We believe that moisture ingress is occurring when subjected to high humidity, leading to buildup of water with the layers of protective paints and resulting in mirror breakage when water expands in freezing conditions. In order to mitigate or eliminate this issue, a new weatherproofing strategy may be implemented or a new mirror component may be used that is able to survive accelerated aging conditions.

14 SOLAR ENERGY↗

Effect of turbulence-induced correlation on laser remote sensing errors

Using a 10.6-micron dual-laser differential-absorption laser remote sensing system, the short- and long-term temporal correlation of the returns from topographic targets and retroreflectors are measured in order to investigate the effect of atmospheric turbulence on laser remote sensing measurement errors. The results quantify the improvement obtained through use of a dual-laser system compared to that of a single-laser system and are in good agreement with those predicted by a theory which considers the effect of partial temporal correlation on the resultant measurement error.

Killinger, D. K.↗

Development of Readily Available & Robust High Heat Flux Gardon Gauges

Concentrated solar power (CSP) technologies deliver concentrated solar energy as a heat source to industrial processes, power generation cycles, and chemical cycles. CSP systems require accurate and reliable high flux measurements, and next generation CSP systems will require flux measurement up to 1000 W/cm2. Existing flux measurement devices do not comprehensively meet the flux rating, cycle life, cost, and lead-time needs of stakeholders, necessitating the development of an improved flux sensor. In this study, Sandia National Laboratories (SNL) partnered with Hukseflux Thermal Sensors to develop a low-cost, short lead-time, and robust flux sensor rated to 250 W/cm2. Three prototype circular foil gauge designs were assessed for performance at the National Solar Thermal Test Facility (NSTTF) at SNL. Each gauge design measured flux up to 250 W/cm2 with <5% measurement error. Following baseline error quantification, gauges were exposed to flux above 500 W/cm2 to assess gauge failure mechanisms. Gauges physically survived >500 W/cm2 flux exposure, but measurement error was found to increase after foil coatings reached 400 °C. The results of this study suggest that coating optical properties change at excessive temperatures and that foil coating temperature, rather than heat flux level, dictates the acceptable gauge measurement range.

McLaughlin, Luke (ORCID:0000000303711310)↗

Ground control points refresh for MODIS and VIIRS geolocation monitoring

The Control Point Matching (CPM) program and a set of over 1200 globally distributed ground control points (GCPs ) have been successfully used to develop more than 20 years of MODIS geolocation products. In this research, we refresh current GCP library with more than 2500 new GCPs using the latest Landsat 8 Collection 2 images. The refreshed GCPs are distributed from 56 S to 80 N latitude, with more than 2000 shoreline and 500 inland GCP chips. The size of these GCPs are extended from800*800 to 1400*1400 Landsat pixels and the CPM program correspondingly increase s t h e searching distance from 0.8 pixels to 2.5 pixels, which also extends the geolocation error measurement from +/-45 to the edge of scan at +/-55 degree in scan angle. This will allow the algorithm to catch geolocation errors that are larger than one MODIS pixel. The geolocation errors measured with the refreshed GCP library are comparable to the previous results, yet with 2-3more times of matched GCPs. The daytime Aqua ascending orbits and Terra descending orbits enable us to identify a few GCP outliers which might be due to the quality of the original Landsat images. Most importantly, the refreshed GCP library will include images from both Landsat band 4 to match with VIIRS I1, and Landsat band 6 to match with VIIRS I3. This will allow us to measure and correct on orbit band-to-band registration at both track and scan directions, which will help understanding and improving future JPSS mission’s prelaunch geometric performance.

VIIRS↗