LANL studies of ESD spark energy discharge through September 2019

Two concentric-sphere apparatuses were used to measure the energies deposited by electric sparks through air to calibrated loads. Both sets of spheres had clean, uninsulated metal surfaces. The 127-mm diameter pair of spheres had a gap of 10 mm and a capacitance of 52 pF. The maximum energy stored on these spheres was 12 mJ and the maximum energy delivered to the 50-mΩ load was 11 µJ, with or without inductance. This load energy amounted to 0.09% of the available input energy; the remainder of the input energy was expended in forming the spark. The second set of spheres was 330 mm in diameter with a gap of 14 mm and a capacitance of 240 pF. The maximum energy stored on these spheres was 71 mJ and the maximum energy delivered to the 50-mΩ load was 150 µJ without added inductance. This load energy was 0.27% of the input energy; again, the remainder of the input energy was expended in forming the spark. The inclusion of 250 nH and 500 nH inductances in the discharge path of the smaller spheres caused the current discharges to resonate, but had little effect on the maximum energies deposited in the loads. At the time of writing, inductances had not yet been added to the larger spheres. The magnitudes of the observed spark discharges were stochastic, so more than 1200 tests were required to develop the statistical bounds of the spark behavior, i.e., to estimate the worst case (highest likely) energy depositions in the loads. The action integrals of the current discharges $∫ i^2dt$ were found to be approximately independent of the load resistances for loads of less than ~1 Ω. Hence the energy deposition scaled with resistance as 207 µJ/Ω and 2.93 mJ/Ω for the two apparatuses.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The WTP LAB stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the ANSI/HPS N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the DV of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The maximum 6 DV value from the scale model testing determines the maximum conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be = 20°. Second, the velocity uniformity at the full-scale stack must be = 20% COV. Finally, the velocity uniformity results for the actual and scale model stacks must agree within 5% COV. In general, these criteria were met through the full-scale stack tests at the LAB facility. Some specific items for each scale model and full-scale stack comparison should be noted in assessing the validity of the verification tests. The LB-C2 scale model stacks were performed with single fan operations at then-minimum flow conditions. These conditions resulted in DV values that were too low to meet the DV range criterion, and therefore are unable to be used in qualifying single fan operations on the full-scale stack. However, the single fan operations demonstrated COV values for velocity uniformity as well as flow angles that were comparable to the dual-fan operations at high flows. Overall, the test conditions and test results were within the range of acceptable values based on current design flow rates. Single fan operations are expected to only occur infrequently for maintenance needs and is therefore not a planned operating condition at this time. The LB-S1 scale model stacks were performed at three fan combinations, and in each combination, at least one test was performed at the then-minimum flow conditions as well as at then-maximum flow conditions. While the then-minimum flow conditions result in a DV range that is lower than the verification test DV value, and therefore does not meet the criterion, these tests are un-necessary for the verification test acceptance. The normal and maximum flow conditions from the scale model stack tests meet the DV range criterion, and the velocity uniformity test results compare favorably with the full-scale stack results. The LB-S2 scale model stacks were performed at nominally the same maximum flow condition; however, the 6 DV value for Fan A operation was slightly lower than the full-scale stack test DV. The COV values from the scale model stacks were comparable between the Fan A and Fan B results, and the overall test conditions are within the range of acceptable values. The stack verification is therefore considered acceptable for both Fan A and Fan B operations. The verification tests were performed at flows that were appreciably higher than the design conditions, and further elevated flow rates would be beyond the range of acceptable DV. Based on these stack verification test results, the three LAB filtered exhaust stacks meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the scale model test reports (Glissmeyer, Flaherty, and Piepel (2001), Glissmeyer and Geeting (2013)) may require additional tests and additional analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of the moderators in the STS preliminary design

This report details the results for an optimization of the dimensions of the moderators in the preliminary design of the Spallation Neutron Source Second Target Station (STS). This study uses the optimization algorithms of Dakota and an unstructured mesh model for the moderators in MCNP. More details on the unstructured mesh model and the automated mesh generation can be found in [3]. Parallel to this effort, the same moderator geometries have been optimized using a constructive solid geometry (CSG) MCNP model. More details on this model and its results can be found in [4]. Three optimal designs are selected for each moderator: one that is optimized for maximum peak brightness, one for maximum time-integrated brightness, and one for a combination of peak and time-integrated brightness. The backbone of the optimization work flow is provided by Dakota. For each set of design parameters requested by Dakota, a new solid geometry is automatically built in Creo and SpaceClaim, and subsequently exported to Attila4MC to generate an unstructured mesh geometry for MCNP. After the MCNP calculation is finished, the objective function (e.g., brightness metric) is returned to Dakota. After the new design has been evaluated, a result-file is written, and Dakota proposes the next set of design parameters to be evaluated. The loop continues until a specified convergence criterion has been met. The design parameters of the cylindrical (upper) moderator include the hydrogen radius, the premoderator thickness (top, bottom, radial), the beryllium radius and the horizontal position of the moderator. The crucial design choice is the hydrogen radius. A radius of 62 mm is shown to provide the maximum time-integrated brightness. The maximum peak brightness occurs with a radius of 40 mm. A combined (middle) design, which balances peak and time-integrated brightnesses, is obtained with a hydrogen radius of 50 mm. The premoderator thicknesses and the beryllium radius are slightly larger in the design optimized for time-integrated brightness than in the design optimized for peak brightness. The sensitivity to these two parameters is relatively small close to the optimal configurations. The hydrogen vessel and vacuum vessel wall thicknesses are dependent on the radius of the liquid hydrogen due to structural integrity requirements. The increased wall thicknesses for larger vessels significantly penalize the time-integrated brightness, with the maximum obtainable value reduced by more than 10% relative to earlier studies which used fixed vessel wall thicknesses. The impact of the variable wall thicknesses is much less for the peak brightness and combined brightness designs. The design parameters of the tube (lower) moderator selected for the optimization are the tube length, the annular premoderator thickness, the beryllium radius and the horizontal position of the moderator. The tube length is the crucial parameter and is chosen large (210 mm) and small (125 mm) in the designs optimized for time-integrated and peak brightness respectively. A combined optimal design has a tube length of 170 mm. The premoderator thickness and the beryllium radius are chosen larger in the design optimized for time-integrated brightness.

42 ENGINEERING↗

Shallow- and deep-convection characteristics in the greater Houston, Texas, area using cell tracking methodology

The convective lifecycle, from initiation to maturity and dissipation, is driven by a combination of kinematic, thermodynamic, microphysical, and radiative processes that are strongly coupled and variable in time and space. Weather radars have been traditionally used to provide various convective-cloud characteristics. Here, we analyzed climatological convective-cell radar characteristics to obtain and assess the diurnal cycles of three convective-cell types – shallow, modest deep, and vigorous deep convective cells – that formed in the greater Houston area, using the National Weather Service radar from Houston, Texas, and a multi-cell identification and tracking algorithm. The examined dataset spans 4 years (2018–2021) and covers the warm-season months (June to September) in those years. The analysis showed clear diurnal cycles in cell initiation (CI) consistent with the sea breeze circulation and showed diurnal and normalized lifetime relationships in cell evolution parameters (e.g., maximum reflectivity, echo-top height, Geostationary Operational Environmental Satellite-16 (GOES-16) channel 13 brightness temperature, and the height of maximum reflectivity). The cell evolution is well represented by relationships between (1) the height and value of the maximum radar reflectivity, (2) the minimum GOES-16 channel 13 brightness temperature and the maximum vertically integrated liquid, (3) the maximum reflectivity and columnar-average reflectivity, and (4) the echo-top ascent rate and cell lifetime. The relationships presented herein help to identify the cell lifecycle stages such as early shallow convection, vigorous vertical development, anvil development, and convective core dissipation. GOES-16 Aerosol Optical Depth values are also used as a proxy for cell initiation aerosol concentrations to investigate any potential relationships between initiation location and aerosol concentration. Overall, no significant relationships between initiation location and aerosol concentration were found for the three cell types investigated, but there are some minor differences in the pre-CI aerosol optical depth for vigorous deep convective cells.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity Effects of High Temperature Overhead Conductors to Line Rating Variables

For traditional overhead transmission lines, the maximum allowable conductor operating temperature on ASCR, AAC, or AAAC lines for determining the static line ratings can be quite low, typically well under 100 C. At these low temperatures, the primary driver for determining static line ratings are assumptions made about the wind speed and direction and the ambient temperature. Assumptions for solar loading and emitted thermal radiation, driven by line emissivity and absorptivity, are secondary factors, and only provide small changes to the static ratings. However, when considering newer high temperature conductors such as ACSS, ACCR, ZTACIR, and ACCC® the maximum allowable conductor temperatures can be significantly higher, up to 250° C. This higher temperature shifts the importance of the emissivity assumptions of the overhead transmission line, due to the nature of the T4 dependence of the radiative heat loss compared to the T1 dependence of the convective heat loss, as well as shifting the dependency on local wind conditions. Typical assumptions in the United States for the emissivity/absorptivity of overhead transmission lines in determining the static ratings are to use a value of 0.5 for both parameters or set a value in the range of 0.7 to 0.9. Recent experimental tests at EPRI have shown that higher emissivity aging assumptions may not be valid in some regions of the US, and that actual values may be much lower (0.25-0.45) than older studies have predicted (0.8-0.9). Here, the assumptions of different US Regional Transmission Operators (RTOs) and different utilities within RTOs are examined for the static ratings for traditional lower operating temperatures up to 100° C as well as with the higher maximum temperature conductors associated with newer conductor designs at 250° C. The sensitivity of the static ratings is examined at both lower and higher temperature conductors with respect to overhead line emissivity and absorptivity, wind speed, wind direction, and solar loading, and ambient temperature. It is shown that the effects of the conductor absorptivity, solar flux and ambient temperature on the static rating are increased when the transmission line has a lower maximum conductor temperature. The effects of the conductor emissivity, wind direction and wind speed have increased effects on the static rating when the transmission line has a higher maximum conductor temperature. In addition, example weather data is used to calculate the conductor temperature with different line emissivity and absorptivity assumptions. This shows the effect of assumptions made for emissivity only has a minor impact for low temperature lines, but for high temperature transmission lines can cause a 150-200° C temperature swing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Success Using A Granular-Activated Carbon Filtration Swab to Rehabilitate Westbay{sup R} Multi-level Groundwater Monitoring Wells at the INL - 20544

In November 2015, tetrachloroethylene (PCE) was discovered in groundwater samples collected from a Westbay{sup R} multi-level groundwater monitoring well at the Idaho National Laboratory (INL).a Subsequent investigation determined that PCE was not present in the groundwater. The detected PCE was instead due to inadvertent contamination of the internal tubing fluid in the Westbay well-monitoring system, which is isolated from the surrounding groundwater. Further investigation showed that three of the 11 Westbay wells at the INL contained PCE-contaminated tubing fluid at concentrations above the U.S. Environmental Protection Agency's maximum contaminant level for drinking water (5 μg/L). Loose sediment at the bottom of some Westbay wells was also found to contain PCE; the three wells were then identified for rehabilitation as part of the INL well maintenance program. The unique construction of the Westbay wells - i.e., the small diameter (5.72 cm [2.25 in.]) and the depths of the tubing fluid ranging from 144.8 to 419 m (475 to 1,376 ft) below ground surface - posed unique challenges to the rehabilitation. Because the tubing fluid provides structural integrity, the fluid cannot be removed and then replaced without damaging the integrity of the Westbay well. Additionally, the small diameter of the systems and the associated depths limit the availability of equipment that can be used for the rehabilitation. After an evaluation of potential methods, it was determined that the use of an in-well, custom-fabricated, granular-activated-carbon filtration swab deployed via a wire line would provide the safest and most cost-effective method for rehabilitation. Westbay well rehabilitation started at well MIDDLE-2051 in late June 2018 and paused in December 2018 for the season. The PCE concentration in the tubing fluid at MIDDLE-2051 was initially reduced to a maximum concentration of 3.81 μg/L from a maximum of 642 μg/L, while the concentration of PCE in the sediment had been reduced from 5,360 to 2,270 μg/kg. Sampling was performed at MIDDLE-2051 again in August 2019, and the tubing fluid increased to a maximum concentration of 45.4 μg/L, while the concentration in the sediment decreased further to 1,890 μg/kg due to desorption of PCE from the sediment to the tubing fluid. Rehabilitation resumed at well MIDDLE-2050A in late August 2019, and the PCE concentration in the tubing fluid had been reduced to a maximum concentration of 19.0 μg/L. Although the method has been shown to be time-consuming, it has proven to be effective and safe for personnel performing the work and to the integrity of the well. Future sample data results at all wells will help determine an estimated completion of the rehabilitation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electric-vehicle battery second-life and recycling pathways: How economics depend on chemistry, processing, and application

We assess the economics of repurposing and recycling electric vehicle (EV) batteries by estimating the maximum acquisition price repurposers and recyclers could pay for used EV packs across cathode chemistries, first-life conditions, second-life applications, and recycling processes. We develop a novel open-source process-based cost model of a UL-1974-certified repurposing facility and leverage battery degradation models to estimate the maximum acquisition price repurposers could pay for used EV batteries while producing second-life battery energy storage systems with life-adjusted costs equivalent to new systems. We compare these maximum price estimates to maximum prices for recyclers based on cost and revenue estimates from the EverBatt model. We find that repurposing is more economical than recycling for lithium iron phosphate (LFP) batteries, due to their relatively long life and low value materials; recycling is generally more economical than repurposing for lithium nickel cobalt aluminum oxide (NCA) batteries, due to their shorter life and higher value materials; and the economics for lithium nickel manganese cobalt oxide (NMC) batteries depend more heavily on first life retirement conditions and second life application intensity. These results suggest an overall strategy: reuse LFP, recycle NCA, and sort NMC into recycling or repurposing pathways based on state of health and second-life application.

25 ENERGY STORAGE↗

An energy model of droplet impingement on an inclined wall under isothermal and non-isothermal environments

The observation of spray-wall interaction is of great importance to understand the dynamics that occur during fuel impingement onto the chamber wall or piston surfaces in internal combustion engines. It is found that the maximum spreading length of an impinged droplet can provide a quantitative estimation of heat transfer and energy transformation for spray-wall interaction. Furthermore, it influences the air-fuel mixing and hydrocarbon and particle emissions at combusting conditions. In this paper, an analytical model of different droplet-wall impingement conditions is developed in terms of βm (dimensionless maximum spreading length, the ratio of maximum spreading length to initial droplet diameter) to understand the detailed impinging dynamic process. These conditions are grouped as: a single diesel droplet impinging on the wall with different inclined angles (α); cold wall - heated droplet and heated wall - cold droplet impingement when inclined angle of the wall is 0°, respectively. The analytical model is built up based on the energy conservation that considers kinetic energy, gravitation energy, and surface energy before impingement, as well as viscous dissipation, gravitation energy, adhesion energy, deformation energy, and heat energy after impingement. The experimental work of diesel droplet impinging on an inclined wall is performed at a certain range of the Weber number (We of 33 to 420) with various inclined angles (α of 0° to 45°), while for inclined angle is 0°, droplet and wall temperature are varied from 25°C to 150°C to study the effects of the inclined angle and temperature on the temporal evolution of the post-impingement characteristics (i.e. droplet spreading length, dynamic contact angle). The analytical model is validated and evaluated at the aforementioned experimental operating points. The validated model can be employed to predict maximum spreading length of the droplet impinged on the wall. It is further utilized to determine the transition from capillary regime to kinetic regime, then to viscous regime at different inclined angle of the wall.

42 ENGINEERING↗

Impacts of climate change on future hurricane induced rainfall and flooding in a coastal watershed: A case study on Hurricane Harvey

The warming climate is likely to increase hurricane-associated extreme rainfall and lead to sea-level rise (SLR). Thus, how the floods induced by intense hurricanes respond to these potential changes is of great concern. This study investigates the future warmer climate impacts on hurricane-induced extreme rainfall, and—more importantly—the subsequent compound flooding at the watershed scale (from an event-based analysis perspective). To this goal, a modeling framework is designed based on the Distributed Hydrology Soil Vegetation Model (DHSVM), the Two-Dimensional fvand the Regional Community Earth System Model (R-CESM). The framework was applied to Hurricane Harvey (2017) at the Clear Creek watershed (a coastal watershed in the southern Houston) as a case study. The results show that the projected maximum rainfall totals over the watershed would be exacerbated by 17.7 % and 49.7 % in the 2050s and 2090s (respectively) under Representative Concentration Pathway 8.5 (RCP 8.5). This means a 16.1 % increase in Harvey rainfall over the watershed per degree Celsius increase in Mean Surface Temperature over the Gulf of Mexico region (18°~31° N, 77°~98° W). Meanwhile, the increases in maximum inundation extent would be 11.0 % (2050s) and 19.5 % (2090s). Furthermore, considerable increases in maximum inundation depth and duration in regions along the middle and downstream of Clear Creek (and also those around Clear Lake) are expected. The projected SLR will have little effect on the maximum inundation depth and extent if storm surge changes are not taken into account; meanwhile, it will influence the inundation duration at downstream locations. In conclusion, this modeling framework can be also applied at other coastal watersheds to evaluate the projected climate change impacts on the compound flooding induced by extreme climate events.

54 ENVIRONMENTAL SCIENCES↗

Void swelling of conventional and composition engineered HT9 alloys after high-dose self-ion irradiation

Ferritic/martensitic (F/M) steels are being considered as potential structural materials for next generation nuclear reactors, and variants of the alloy HT9 are some of the most promising candidates. In this study, two conventional and two composition engineered HT9 alloys were irradiated using 3.5 MeV Fe 2+ up to 600 peak displacement-per-atom (dpa) at 450 °C. Void swelling and microstructure evolution were characterized for each alloy and compared. The two conventional HT9 alloys (INL and ACO3) showed similar void swelling behavior due to their similar elemental composition and processing conditions. The INL HT9 exhibited a maximum of 2.4% swelling and the ACO3 HT9 showed a maximum of 2.8% swelling at 342 and 393 average local dpa, respectively. On the other hand, the two-composition engineered HT9 alloys with varying N contents (10 ppm for low N and 440 ppm for high N) showed disparate swelling behavior. The low N HT9 exhibited a maximum of 4.6% swelling, while the high N HT9 showed a maximum of 0.7% swelling at 342 average local dpa. Changes in the N content also affected Ni/Si rich G-phase formation. The low N HT9 showed a larger size and lower density of G-phase precipitates compared with the high N HT9 after 600 peak dpa irradiation. This study compares the void swelling behavior of the ion irradiated four current HT9 alloys to extremely high doses, with the void swelling data from neutron irradiated HT9 alloys. Furthermore, the comparison lends critical insights into how well these current alloys can withstand high neutron fluxes in future reactors, especially since the low N and high N HT9 alloys have never been exposed to such high doses before.

36 MATERIALS SCIENCE↗

Optimization of the Second Target Station cold source moderators using an automated workflow

The Second Target Station (STS) at the US Department of Energy’s Oak Ridge National Laboratory is designed to become the world’s highest peak-brightness spallation source of cold neutrons. Successful completion of the STS, which is currently in the preliminary design phase, will provide transformative new capabilities to examine novel materials for future technologies. At STS, neutrons will be generated by spallation reactions in a solid tungsten target. They will be moderated and thermalized in two cold (20 K) para-hydrogen moderators. Careful optimization of these moderators is essential to the project’s success. To find optimal moderator designs, an advanced optimization workflow integrates high-fidelity neutronics calculations using the Monte Carlo N-Particle (MCNP) transport code MCNP6.2 with state-of-the-art optimization algorithms in the Dakota optimization toolkit. For each design iteration, a parametrized solid CAD geometry is generated in Creo and automatically converted into an unstructured mesh geometry by Attila 4MC for the neutronics calculation with MCNP. Iterations repeat until optimal designs are found. Herein this paper presents the results of a sensitivity and optimization study for the cylindrical and tube moderators. Both moderators can be optimized for maximum peak brightness, maximum time-integrated brightness, or any combination between these extremes. Maximum peak brightness is achieved by using smaller optimal dimensions of the moderators, whereas maximum time-integrated brightness is achieved by using larger dimensions. A Pareto front details the designs that optimally balance both brightness metrics. The Pareto front can be found in only 40–110 iterations with 4–5 design parameters when using the efficient global and Pareto-set optimization algorithms in Dakota. Additionally, important engineering constraints can be taken into account, such as the coupling between the cylindrical moderator radius and aluminum vessel wall thicknesses required to ensure structural integrity of the vessels. This interaction has a significant impact on the resulting optimal designs. Our new, highly efficient, fully automated optimization workflow will be used to optimize additional STS components in the future and can be adopted for design and optimization studies at other experimental neutron and accelerator facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of Casting Parameters and Impurity Concentrations on As-Cast U–10Mo

This work investigates the effects of casting parameter changes on as-cast uranium-10 wt% molybdenum alloys on a 1-2kg scale. A commercial tilt-pour vacuum induction melting system was utilized to study the effects of casting atmosphere, total heating time, hold time at maximum temperature, mold temperature, and crucible type on the as-cast microstructure of U-10Mo. Ten thin plates (5.08 mm thick) and four thick plates (25.4 mm and 63.5 mm thick) were cast and analyzed for carbon, oxygen, hydrogen, and nitrogen impurities. Additionally, molybdenum content and primary dendrite length (PDL) of the microstructure was quantified. A statistical evaluation was performed to identify key carbon and oxygen relationships with operating parameters, impurities, and primary dendrite length. Additional factors investigated include: crucible material, time at maximum temperature, total heating time, and pour temperature. Zirconia crucibles reduced carbon content on average by 35%. Additionally, there was a significant statistical association between carbon and oxygen content, between oxygen content and maximum temperature hold time, between mold temperature and PDL, and between PDL, maximum temperature hold time and mold temperature.

Huber, Zachary F.↗

Design and full core fuel performance assessment of high burnup cores for 4-loop PWRs

Increasing the fuel discharge burnup of current light water reactors (LWRs) promises reductions in fuel cycle and/or operations costs. By assuming a constant core power density, the economic gain is enabled by better fuel utilization and/or an increased capacity factor. In this effort to investigate greater than 62 MWd/kgU maximum rod average burnup for 110+ kW/l core power density, two core designs have been developed for a standard 17x17, 193 fuel assemblies pressurized water reactor (PWR). The levelized unit cost methodology is employed to evaluate fuel cycle, operation and maintenance, and capital cost impacts and to examine the economic viability of both core design pathways. Core design and optimization are performed using the commercial STUDSVIK code package. Fuel performance analysis is realized in full core configuration via auditing FRAPCON4.1, FAST1.2, and the high-fidelity code BISON. To provide a realistic assessment, the core design process takes into consideration best practices in current PWR core design. It features acceptable performance in terms of various core design constraints on maximum allowable peaking and boron concentration. Gadolinia (Gd2O3) is used as a burnable poison with a maximum of 9 wt% concentration while feeding 89 or 77 fuel assemblies in a 3-batch refueling scheme. Full core fuel performance simulation, which allows for characterization of relevant fuel temperatures, plenum pressures, stresses, and strains, is performed with respect to two bounding burnup levels. Such performance is potentially licensable for the 18-month high burnup core (<68 MWd/kgU peak pin), while it is more challenging for the 24-month high burnup core design pathway (<75 MWd/kgU peak pin). Maximum rod plenum pressure is identified as the most limiting fuel performance parameter. Here, while the scope of the present study focuses on the steady-state plus overpower conditions, the acceptability of the new discharge burnup has to be further assessed by considering uncertainties and impacts under accident scenarios in the future.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploring topography-based methods for downscaling subgrid precipitation for use in Earth System Models

Topography exerts major control on land surface processes. To improve representation of topographic impacts on land surface processes, a new topography-based subgrid structure has been introduced to the Energy Exascale Earth System Model to represent the subgrid heterogeneity of surface elevation. To take advantage of the new subgrid structure for improving land surface modeling, this study explores four variations of topography-based methods for downscaling grid precipitation to the corresponding subgrids. In the first three methods, the deviation of the subgrid precipitation from the grid’s is equal to the grid precipitation multiplied by the ratio of the elevation difference between the subgrid and grid mean to a specified elevation equals to the grid elevation, the difference between the maximum and minimum subgrid elevation, and the maximum subgrid elevation, respectively. The second method limits the ratio to 0.5 to avoid extreme values on mountains and the third method accounts for the slope effect. The fourth method is similar to the third method except that the Froude Number is used to limit the numerator in a blocking regime of the ambient flow. The downscaled precipitation is evaluated using the PRISM precipitation data over the U.S. using statistical metrics. Results show that by accounting for topographic slope besides elevation, the third and fourth methods show clear advantages over the first and second methods. Furthermore, introducing the Froude Number in the fourth method improves downscaling skill and shows consistent advantages over the third method in areas with larger subgrid heterogeneity across different grids sizes.

Tesfa, Teklu K.↗

Revisiting the Definition of Rapid Intensification of Tropical Cyclones by Clustering the Initial Intensity and Inner‐Core Size

Abstract Rapid intensification (RI) of tropical cyclones (TCs) provides a great challenge in operational forecasting and contributes significantly to the development of major TCs. RI is commonly defined as an increase in the maximum sustained surface wind speed of at least a certain threshold within 24 hr. The most widely used threshold is 30 kt (15.4 m/s), which was determined statistically. Here we propose a new definition for RI by objectively clustering TCs using the intensification rate, initial intensity, and radius of the maximum wind speed (RMW). A group of 770 samples is separated at a threshold of 45 kt (23.2 m/s). The threshold is 40 kt (20.6 m/s) for the western North Atlantic, where TC size measurements are more reliable. Monte Carlo experiments demonstrate that the proposed threshold is robust even considering the uncertainty in RMW of as high as 30 km. We show that, when a TC undergoes RI, its maximum wind speed is approximately 60 ± 15 kt (30.9 ± 7.7 m/s) and the RMW is 45 ± 20 km. The new threshold outperforms the conventional threshold of 30 kt/24 hr in describing the bimodal distribution of lifetime maximum intensity and explaining the annual count of Category 5 TCs. This new definition provides a more physically based threshold and describes a more reliable representation of extreme events. Although more comparisons are needed for operational application, it is likely to be desirable for case‐based process studies and could provide a more valuable metric for TC intensification classification and research.

Li, Yi↗

Updraft Width Modulates Ambient Atmospheric Controls on Convective Cloud Depth

Abstract The depth of convective clouds affects vertical transport of atmospheric constituents, influencing downstream weather and climate. Atmospheric controls on the maximum depth reached by moist convection are investigated with radar‐tracked convective cells tagged with sounding‐derived atmospheric parameters from a field campaign in central Argentina. Regression analyses show that narrow (<12‐km diameter) and wide (>16‐km diameter) cell depths respond to disparate factors, where cell areas are defined using composite reflectivity signatures. Undiluted lifted parcel indices including convective available potential energy (CAPE) and level of neutral buoyancy (LNB) are top predictors of wide cell maximum depth while mid‐tropospheric relative humidity is the top predictor of narrow cell maximum depth. Because narrow cells are more numerous than wide cells, the overall outcome of the full cell population does not strongly correlate with CAPE and LNB conditions. Tracked cells and atmospheric conditions in a simulation with 3‐km grid spacing covering the field campaign produce similar results to those observed. Narrow cells that are relatively deep have a cooler and moister mid‐troposphere with weaker free tropospheric subsidence, while relatively deep wide cells have much warmer and moister lower tropospheric conditions. These atmospheric differences are present 1 hr before cell initiation at both a fixed observing site and variable cell initiation locations. Simulated narrow cell maximum equivalent potential temperature decreases with height at a rate similar to the ambient vertical gradient, causing these cells to fall short of their LNB and supporting the view that entrainment‐driven dilution is a dominant control on their depth.

54 ENVIRONMENTAL SCIENCES↗

Interfacial water asymmetry at ideal electrochemical interfaces

Controlling electrochemical reactivity requires a detailed understanding of the charging behavior and thermodynamics of the electrochemical interface. Experiments can independently probe the overall charge response of the electrochemical double layer by capacitance measurements and the thermodynamics of the inner layer with potential of maximum entropy measurements. Relating these properties by computational modeling of the electrochemical interface has so far been challenging due to the low accuracy of classical molecular dynamics (MD) for capacitance and the limited time and length scales of ab initio MD. Here, we combine large ensembles of long-time-scale classical MD simulations with charge response from electronic density functional theory to predict the potential-dependent capacitance of a family of ideal aqueous electrochemical interfaces with different peak capacitances. We show that while the potential of maximum capacitance varies, this entire family exhibits an electrode charge of maximum capacitance (CMC) between -2.9 and -2.2 μC/cm 2 , regardless of the details in the electronic response. Simulated heating of the same interfaces reveals that the entropy peaks at a charge of maximum entropy (CME) of -5.1 ± 0.6 μC/cm 2 , in agreement with experimental findings for metallic electrodes. The CME and CMC both indicate asymmetric response of interfacial water that is stronger for negatively charged electrodes, while the difference between CME and CMC illustrates the richness in behavior of even the ideal electrochemical interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-linear MHD modelling of edge localized modes suppression by resonant magnetic perturbations in ITER

Edge localized modes (ELMs) suppression by resonant magnetic perturbations (RMPs) was studied with the non-linear magneto-hydro-dynamic (MHD) code JOREK for the ITER H-mode scenarios at 15 MA, 12.5 MA, 10 MA/5.3 T. In this study, the main aim was to demonstrate that ELMs can be suppressed by RMPs while the divertor 3D footprints of heat and particle fluxes remain within divertor material limits. The unstable peeling–ballooning modes responsible for ELMs without RMPs were modelled first for each scenario using numerically accessible parameters for ITER. Then the stabilization of ELMs by RMPs was modelled with the same parameters. RMP spectra, optimized by the linear MHD MARS-F code, with main toroidal harmonics N = 2, N = 3, N = 4 have been used as boundary conditions of the computational domain of JOREK, including realistic RMP coils, main plasma, scrape off layer (SOL) divertor and realistic first wall. The model includes all relevant plasma flows: toroidal rotation, two fluid diamagnetic effects and neoclassical poloidal friction. With RMPs, the main toroidal harmonic and the non-linearly coupled harmonics remain dominant at the plasma edge, producing saturated modes and a continuous MHD turbulent transport thereby avoiding ELM crashes in all scenarios considered here. The threshold for ELM suppression was found at a maximum RMP coils current of 45 kAt–60 kAt compared to the coils maximum capability of 90 kAt. In the high beta poloidal steady-state 10 MA/5.3 T scenario, a rotating QH-mode without ELMs was observed even without RMPs. In this scenario with RMPs N = 3, N = 4 at 20 kAt maximum current in RMP coils, similar QH-mode behaviour was observed however with dominant edge harmonic corresponding to the main toroidal number of RMPs. The present MHD modelling was limited in time by few tens of ms after RMPs were switched on until the magnetic energy of the modes saturates. As a consequence the thermal energy was still evolving on this time scale, far from the ITER confinement time scale and hence only the form of 3D footprints on the divertor targets can be indicated within this set-up. Also note, that the divertor physics was missing in this model, so realistic values of fluxes are out of reach in this modelling. However the stationary 3D divertor and particle fluxes could be simply extrapolated from these results to the stationary situation considering that a large power fraction should be radiated in the core and SOL and only about 50 MW power is going to the divertor, which is an arbitrary, but reasonable number used here. The 3D footprints with RMPs show the characteristic splitting with the main RMP toroidal symmetry. The maximum radial extension of the footprints typically was ~20 cm in inner divertor and ~40 cm in outer divertor with stationary heat fluxes decreasing further out from the initial strike point from ~5 MW m ₋2 to ~1 MW m ₋2 assuming a total power in the divertor and walls is 50 MW. The heat fluxes remain within the divertor target and baffle areas, however with rather small margin in the outer divertor which could be an issue for the first wall especially in transient regimes when part of the plasma thermal energy is released due to switching on the RMP coils. This fact should be considered when RMPs are applied with a more favorable application before or soon after the L–H transition, although optimization is required to avoid increasing the L–H power threshold with RMPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗